• Title/Summary/Keyword: Fire Cause

Search Result 825, Processing Time 0.03 seconds

Pathological Mechanistic Study of Conducting Fire Back to Its Origin (인화귀원(引火歸原)의 병기론 연구)

  • Chough, Won-Joon;Kim, Yeong-Mok
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.21 no.4
    • /
    • pp.795-802
    • /
    • 2007
  • The fire not to back to its origin(火不歸原) is said that source yang(元陽) of sea of qi(氣海) rises because fire(火) of lower energizer(下焦) can't return to its origin. Successive medical men regarded the cause of it as yang deficiency(陽虛) or yin deficiency(陰虛) generally, but Jangseoksun(張錫純) presented eight kinds of cause, they are syndrome of upcast yang(戴陽證), deficiency of qi(氣虛), yin deficiency, yin and yang deficiency(陰陽虛), thoroughfare qi ascending counterflow(衝氣上衝), heart fire(心火), yang deficiency with cold fluid retention(寒飮) in middle energizer(中焦寒飮), yang deficiency with sunken cold locked in(沈寒錮冷). The method of conducting fire back to its origin may be the treatment of fire not to back to its origin as an interpretation of the phrase in a broad sense, but it is limited to yang deficiency with sunken cold locked in besides syndrome of upcast yang as the treatment based on pathological conditions. By this standpoint Eunsuryong(殷壽龍) used conducting fire back to its origin to remove hidden cold(伏寒) and make rising false fire(假火) settle. The meaning of conducting fire back to its origin is not just raise yang qi(陽氣) but break sunken cold locked in by using the drugs like Buja(附子), Yukgye(肉桂). Jakyak(芍藥) can concentrate yang qi on the life gate(命門) by converging it, Sukjihwang(熟地黃) can supply yin essence(陰精) and check the intense nature of tonifing yang(補陽) drugs. So if we want to use the method of conducting fire back to its origin, we should confirm the symptoms of sunken cold locked in and yang deficiency not to misdiagnose yin deficiency.

Identification of Problems and Improvement Measures of Fire Observer Operation in Domestic Manufacturing Industry (국내 제조업 화재감시자 운영의 문제 확인 및 개선방안)

  • Kyung Min Kim;Yongyoon Suh;Jong Bin Lee;Seong Rok Chang
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.6
    • /
    • pp.26-35
    • /
    • 2023
  • Sparks cause most fire and explosion accidents in the manufacturing industry during hot work, which ignites surrounding combustible materials. Such incidents lead to high casualties due to suffocation from toxic gases and lack of evacuation. Therefore, the government recently enacted and revised 'The Occupational Safety and Health Act' to prevent fires and explosions at work sites, incorporating legal standards for fire observers, which are important in preventing accidents and the spread of fire during hot work. However, there are notable shortcomings in conducting professional cause analysis of these accidents and in aligning them with advanced foreign legal standards. Additionally, there is a lack of literature review reflecting the manufacturing industry characteristics. Despite the recent enactment and revision of legal standards, gathering sufficient opinions and professional reviews remains insufficient. To address these gaps, interviews were conducted with safety and health workers, analyzing recent fire and explosion causes in domestic manufacturing industries, and reviewing both domestic and international legal standards. Conclusively, proposed improvement measures were centered on the professionalization of fire observer education, enhancing their roles and authority realistically, and improving fire observer placement and operation standards. Consequently, additional 'Occupational Safety and Health Act' standards are necessary for fire observer education and defining the government's role. Second, precise legal standards outlining the role and authority of fire observers are required. Third tailored fire observer arrangements and management standards appropriate for varying work characteristics and company sizes are required. This study emphasizes the importance of supplementing relevant legal standards to prevent fire accidents in the manufacturing industry.

Experimental Studies on the Burning Forms of Flammable Liquids (인화성액체의 연소 형태에 관한 실험적 연구)

  • Choi, Seung-Bok;Choi, Don-Mook
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2010.04a
    • /
    • pp.247-251
    • /
    • 2010
  • The victims of fire are increasing steadily. Fires have been occurred by arson, spontaneous combustion and various causes. As a result of that, the damages of fire got out of hand. Especially, the fires of flammable liquids are can be spreaded easily because of high calorific value and fire loads. These rapid fire spread cause the huge losses of both life and property and the malfunction of extinguishing systems. In these studies, we examined the spread pattern of surface fire on the water surface by the reappearance experiment.

  • PDF

Development of H/W and S/W for Detecting Electrical Fire Precursor Signal on Electrical Wirings (배선에서 전기화재 전조신호 검출을 위한 H/W 및 S/W 구축)

  • Kim, Sung-Chul;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.3
    • /
    • pp.13-18
    • /
    • 2009
  • This paper is purposed to develop DAQ H/W, S/W and DB which can be used in developing electrical fire alarm system or in analyzing electrical fire cause, by detecting and monitoring precursor signals which have high possibility leading to electrical fire on electrical distribution wires. In this paper, developed was DAQ H/W adopting the C8051FXXX CPU which can analyze the measurement signals of current and voltage in electrical distribution wires, other CPU was investigated in view of the best digital sampling rate on the basis of previous researches for electrical fire alarm system. Also, the S/W which can interface with DAQ H/W's communication protocol and can be applied for electrical fire causes analysis, are embodied by LabVIEW. The combined DAQ H/W and S/W could analyze efficiently normal as well as abnormal electrical signals such as RMS value, instantaneous value of current and voltage, frequency signals etc, on the electrical wires. Also, DB system was constructed for recording various analysis results for precursor signals including voltage and current signals. The results by simulator and experiment showed that the suggested scheme with DAQ H/W, S/W and DB in this paper has high usability.

A Study on the Risk Management Information System of the Underground Space - focused on Fire Growth Risk Assessment System- (지하공간의 위험관리정보시스템에 관한 연구 -화재확산평가시스템 중심으로-)

  • 박종근;노삼규
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.49-58
    • /
    • 2002
  • A large number of accidents at an underground place have been happening, including the gas explosion under construction of subway; the fires of underground utility and underground shopping malls, and other explosion, at home and abroad recently. These accidents make the function of a city ineffective due to the paralyses of electricity and communications net as well as the loss of property and cause people to feel unsecured with accompaniment of a heavy of toll of lives. This research will show evaluation methods of a numerical value of expected average loss space of combustion with the use of probability in order to present potential risk of combustion growth that underground space might cause, and how designer decides a system that enables us to compare and evaluate relatively the effectiveness of measures for preventing burning by calculating the expansion route and the damage size of burning in case of fire.

Analysis of Fire Accidents on Power Line for DC Electric Traction Vehicles (전기철도 전원계통에서의 화재 사고사례 분석)

  • Song, Jae-Yong;Cho, Young-Jin;Kim, Jin-Pyo;Park, Nam-Kyu;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.241-247
    • /
    • 2008
  • This paper describes a cause of fire accidents on power system for DC electric traction vehicles. We investigated fire scene of power line for DC electric traction vehicles. From analysis results, the cause of fire on power line turned out line to ground fault between a feeder of electric power services(pantagraph) and DC electric traction vehicle roof. Fire accidents of DC electric traction vehicles be assumed that electric sparks had been produced between the pantagraph and the power line conductor by repetitively making contact and separation, maybe if some material like branches get in between connecting rod it make progress line to ground fault. ZnO arresters are widely used to protect DC electric traction vehicles against overvoltages caused by lightning or switching surges. However, the arresters are deteriorated by commercial frequency overvoltages and/or lightning one. Deteriorated arresters could lead power failures, such as line to ground fault by a thermal runaway resulting from the increases in leakage current even in a nominal power system voltage. The power failures, such as line to ground fault would be causative of the fire accidents.

  • PDF

A Study to Prevent the Forest Fire in Forest Facilities and Forests (산림과 산림시설물의 산불 피해 예방에 관한 고찰)

  • Park, Kyong-Jin;Kim, Hye-ree;Lee, Bong-Woo;Park, Shin-young
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.2_2
    • /
    • pp.301-306
    • /
    • 2020
  • In this study, analyzed national forest fire statistics by cause, year, region, and damage scale based on the National Fire Data System. as a result, the main cause of forest fires was the most frequent human error. forest fires occurred in areas with high population density. and it was confirmed that the Widest area of forest damage was Gang-Won province, which is rich in forestry resources. by season, it occurred a lot in spring because of the warm temperature and strong wind and low humidity. such disasters directly damage forest facilities such as house and cultural properties as well as destruction of natural resources. therefore in this study, made a suggestion plan for prevention from forest fire with forest fire prevention comprehensive plan of MFOA.

Criminal Legal Study of Fire Investigation (화재감식의 형사법적 연구)

  • Kong, Ha-Sung;Kim, Su-Youl
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.1-9
    • /
    • 2010
  • In a side of criminal law, fire investigation, as general people fully can understand and prosecution is possible until deciding its cause and suspect, scientific researching method should be studied deeply. This paper proposes an establishment of fire investigation act and its sub-laws, constitution of joint commission for fire investigation, modernization of fire investigation equipments, substantiality of professional education for fire investigation and subjugation of departmentalism as a method to maintain and supplement an institution of fire investigation in Korea.

ASSESSMENT ON NUMERICAL ANALYSIS OF THERMAL FLOW INDUCED BY FIRE (화재시 열유동장의 수치해석에 대한 평가 연구)

  • Kim, J.Y.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.156-160
    • /
    • 2011
  • As building becomes larger, taller and more complex due to industrialization and urbanization, it tends to be vulnerable to fire and establishment of effective measures for fire safety is demanded. Especially the fact that the smoke hinders evacuation and fire-fighting activities as well as becomes the major cause of life casualty emphasizes the importance of smoke control system. To design and operate the smoke control system success folly, it is necessary to analyze and predict precisely the thermoflow induced by fire in building. The unsteady three-dimensional analysis of thermoflow induced by fire with diverse variables such as building structure, fire conditions and smoke control facilities can be effectively carried out with numerical method In this study, using the FDS(Fire Dynamics Simulation) program that spreads widely as the analysis tool for thermoflow of fire, the analysis of thermoflow in partition of building induced by fire and comparison with the experimental results for assessment of numerical analysis are presented.

  • PDF

A Case Analysis of Intentional Car Explosion (고의에 의한 승용차폭발 사례의 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.119-127
    • /
    • 2017
  • This study analyzed the cause of car explosion that occurred in the riverside park. The car carrying a male driver and a female passenger was parked in the park and explosion occurred inside the car. After the explosion, the driver and the passenger got burned. When they went to the hospital by the 119 Rescue Service, they stated that the car was sprayed with thinner before they had a quarrel and the explosion occurred during their quarrel. However, after several days, they changed their statement. They said that gasoline in the plastic bottle was poured and ran into the cigarette lighter. They tried to pull the cigarette lighter but pushed it by mistake. Then explosion occurred. Because only the explosion by mistake could receive car insurance, whether the cause of explosion was intentional or not became an issue. The car exploded was carefully investigated and analyzed. The statement of the driver and passenger was analyzed in the aspect of fire science. As a result, it was demonstrated that this car explosion occurred by driver's intention.