• Title/Summary/Keyword: Fire Board

Search Result 217, Processing Time 0.026 seconds

A Study on Risk Analysis by Type of Ceiling Material Based on Fire Theory (화재이론에 기초한 천장재 종류별 위험성 분석에 관한 연구)

  • Kim, HyeWon;Kim, YunSeong;Lee, ByeongHeun;Jin, SeungHyeon;Koo, InHyuk;Kwon, YoungJin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.116-117
    • /
    • 2021
  • In general, when a building fire occurs, the heat flow rises by buoyancy, which affects the temperature rise of the ceiling. In addition, when the ceiling ignites, the fire spreads rapidly due to horizontal spread and radiant heat. According to the fire investigation, most of the large fires have a common characteristic that the fire spreads to the ceiling and causes many casualties. Therefore, it is considered that it is necessary to review the fire risk of ceiling materials used in buildings to prevent the spread of fire to the ceiling. Therefore, in this study, combustion characteristics such as the amount of heat released and ignition time of each SMC, DMC, and gypsum board were checked using a Cone Calorimeter, and the ignition temperature was calculated by substituting them into the fire theory. As a result, the ignition temperature of SMC was 449K, that of DMC was 1492K, and that of gypsum board was 677K.

  • PDF

A Study on the Fire Resistance Performance of Wood Framed Lightweight Wall which Including a Middle Lintel (중인방을 포함한 목골조 경량벽체의 내화성능에 관한 연구)

  • Yeo, In-Hwan;Cho, Bum-Yean;Min, Byung-Yeol;Yoon, Myung-O
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.91-98
    • /
    • 2011
  • This study is about fire resistance performance of wood framed lightweight wall including a middle lintel as a traditional wall form in Korea. The target wall is non-loadbearing system which constructed with $38{\times}89$ mm ($2"{\times}4"$) wood frame and fireproof gypsum board covering, including a middle lintel made of $150{\times}150$ mm section glue-laminated timber. As a test results, all specimens have showed fire resistant performance over 90 minutes and tests were maintained until flame occuring on Specimen-l, 2, 3 at 91 min, 97 min and 98 min respectively. Fire resistance of the heat side gypsum board was 45 minutes and charring rate of middle lintel was equivalant with that of usual timber. The wood stud inside wall system showed relatively quick combution characteristic when exposed to high temperature with no temperature rising delaying time caused by moisture evaporation because of the dehydration preceded during the early period of fire side gypsum board resist to heat.

Properties of Fire Resistance in Tunnel Concrete According to the Changes of Heating Curve (온도가열곡선 변화에 따른 콘크리트의 내화특성)

  • Pei, Chang-Chun;Noh, Sang-Kyun;Lee, Chan-Young;Lee, Jong-Suk;Lee, Jang-Hwa;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.705-708
    • /
    • 2008
  • To obtain tunnel concrete safety in case of fire, this study analyzed fire proof characteristics by fire proof method change, and the results are as follows. As a fire proof characteristics by RABT temperature heating curve, plain concrete experienced severe spalling by initial extremely high temperature. In view of fire proof method, in the cases of organic fiber mixing method and board method, spalling was prevented, and in the case of spray method, severe spalling of over 100mm depth occurred along with exposure of structural concrete including spray coat by heat stress, etc while metal lath, the stiffener, falls off. As for fire proof characteristics by RWS temperature heating curve, in case of organic fiber inclusion, concrete surface experienced fusion of within 5mm, while in the case of spray method, spray coat was severely spalled to a depth of over 100mm causing structural body concrete to expose its reinforcement, and also in the case of board method, board was fused by high temperature, causing structural body concrete be directly exposed to high temperature, which triggered overall fall-off phenomenon, so in such extraordinary high temperature heating condition, establishment of special fire proof measures is needed.

  • PDF

A Study on the Properties of Fire Endurance and Spalling of High Performance RC Column with the Finishing and Covering Material (고성능 RC 기둥의 마감재 변화에 따른 폭열 및 내화특성에 관한 연구)

  • Han, Cheon-Goo;Hwang, Yin-Seong;Ji, Suk-Won;Kim, Kyoung-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.2
    • /
    • pp.143-152
    • /
    • 2006
  • High performance concrete(HPC) has been widely used in high-rise building. The HPC has several benefits including high strength, high fluidity and high durability. However, spalling is susceptible to occur in HPC and HPC also tends to be deteriorated in the side of fire resistance performance at fire. This paper investigated the spalling prevention of high performance RC column. Control concrete showed severe failure and a case of concrete with fire enduring spraying material exhibited more severe spalling failure than even control concrete. In addition, concrete with fire enduring paint reported the most favorable spalling resistance effect for preventing spall, compared with other concrete covered with finishing materials, such as fire enduring spraying material, gypsum board, marble board and fire enduring PC board. Meanwhile, concrete adding 0.1% of PP fiber demonstrated spalling resistance performance after 3hours load bearing test.

Fire Resistance of High Strength Concrete followed by Thickness of Fireproof Plaster Board and Change of Adhesive Method (방화석고보드의 두께 및 접착방식 변화에 따른 고강도 콘크리트의 내화특성)

  • Jang, Ki-Hyun;Kim, Won-Ki;Jin, Hu-Lin;Lee, Jin-Woo;Yang, Seong-Hwan;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.67-71
    • /
    • 2008
  • The study analyzed on fire resistance of high strength concrete followed by thickness of fireproof plaster board and change of adhesive method. In spalling characteristics after fire resistance test, all four-side covering concretes were left out of testing screens. Thus, serious spalling was happened by exposing their internal reinforcing rods. in partial testing screens, spalling was happened till the internal concrete of main reinforcing rod. Only, temperature history didn't have special differences among changes of adhesive method. However, thickness of fireproof plaster board is very important. Namely, mock member reinforcing 25mm general adhesive + Bending was 583℃ in the highest temperature of surface part and 479℃ in the highest temperature of the main reinforcing rod, which was relatively good temperature history.

  • PDF

Study on Improvement of Dew Point within ESS Container for Fire Prevention (컨테이너형 ESS 화재방지를 위한 내부 응결점 개선 관한 연구)

  • Kim, Woonhak;Kang, Seokwon;Shin, Giseok
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.2
    • /
    • pp.165-174
    • /
    • 2019
  • Purpose: In this study, we investigated the relationship between the causes of ESS container fire accidents. Method: We investigated the possibility of reducing the container fire accident by improving the air environment of the container which is necessary for improvement of these. Result: Through this study, we can be confirmed that the condensing condition of water in the air caused by the difference of internal and external temperature is improved and the dielectric strength of BMS board is reduced. Conclusion: The correlation between the BMS board condensation and the dielectric strength was confirmed.

Effect of Bonding on Bending and Shear Strength of COMPLY Composed of Fire Retardant Treated Particleboard (내화처리(耐火處理) 파티클보오드의 COMPLY접착(接着)이 휨강도(強度)와 전단강도(剪斷強度)에 미치는 영향(影響))

  • Lee, Phil Woo;Kwon, Jin Heon
    • Journal of Korean Society of Forest Science
    • /
    • v.64 no.1
    • /
    • pp.26-32
    • /
    • 1984
  • This research was conducted to examine the effect of bonding on the bending and shear strength of COMPLY-board when used with meranti face veneer and fire retardant treated particle-board core. For ammonium sulfate, modulus of rupture (MOR) of COMPLY-board increased with increasing chemical concentration up to 10 percent and then decreased after that concentration. However, Minalith showed reverse effect to the result for ammonium sulfate. Modulus of elasticity (MOE) of COMPLY-hoard decreased with increasing chemical concentration and its differences were not significant between concentration. Shear strength was shown better when treated with ammonium sulfate than with Minalith. Wood failure of COMPLY increased with increasing chemical concentration up to 15 percent and then decreased after that concentration. The products of parallel and cross veneer laminated were better than those of COMPLY composed of fire retardant treated particle-board core. Non-treated particle-board was the least in strength. MOE of fire retardant treated COMPLY increased by 136 percent and its MOE by 170 percent as compared with non treated particle-board.

  • PDF

A Study on the Ignitibility of Wooden Flooring (목질바닥재의 착화특성에 관한 연구)

  • Kim, Hae-Rim;Kim, Young-Tak;Park, Young-Ju;Lee, Hae-Pyeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.397-402
    • /
    • 2008
  • In this study, we analyzed the ignitibility of the wooden floorings used as the finishing materials for interior with the flammability tester and the ignition point tester. Also we analyzed the limit oxygen index(LOI) using the oxygen index tester and the flame resistance of the wooden floorings. We confirmed that all of the samples had a excellent flame resistance. The ignitibility of the floorings were ranked as the material lumber>the strengthening flooring>the veneer board(1)>the veneer board(2).

  • PDF

Fire resistance of Light-weight Ceramic Board for Exterior Fire resistance Material (경량세라믹보드의 외장재 적용을 위한 화재성능평가)

  • Shin, Hyeon-Uk;Song, Hun;Chu, Yong-Sik;Lee, Jong-Kyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.119-120
    • /
    • 2016
  • This study is about development of inorganic insulation material using by-product materials. The organic material is due to toxic gas emission, when a fire occurs. And it has lower water resistance. The inorganic material is heavy and worse thermal performance than organic materials. In this study, installed light weight ceramic insulation by concrete structure to evaluation fire resistance.

  • PDF