• Title/Summary/Keyword: Fire Board

Search Result 217, Processing Time 0.029 seconds

Construction History of the Old House "IMCHEONGGAK" in Andong and Estimation of its Original Structure -Focused on the 'Inner chamber' and the 'Sarang section'- (안동 "임청각(臨淸閣)"의 건축 이력과 원형 가구(架構) 추정 -사랑채와 안채를 중심으로-)

  • Lee, Jong-Seo
    • Journal of architectural history
    • /
    • v.25 no.2
    • /
    • pp.31-44
    • /
    • 2016
  • Imcheong-gak[臨淸閣] was a familial residence constructed in the early half of the Joseon dynasty period. It was partially destroyed by a fire during the 1590s war[壬辰倭亂] with the Japanese, and another fire that was caused between 1631 and 1634. The inner chamber[An-chae] and the Sarang section[Sarang-chae] today is the result of a partial reconstruction that took place back in 1626 and again around 1634. The residence also went through some changes because the new Ondol[溫突] heating system had to be applied to the structure. Based upon sections that remain in their original forms, we can presume that the Imcheong-gak residence originally had an inner chamber which was composed of the following elements: A main structure which was built upon a foundation featuring a Matbae[맞배] roof, two "Ik'rang[翼廊, flank]" sections on the East and West sides of the inner chamber, and a "Haeng'rang[行廊, passage]" structure on the opposite side of the main structure. Unlike the main structure, other portions of the inner chamber were all built directly upon the ground, and showed multiple stories, with Matbae roofs of their own. We can also assume that the Sarang section in the south would have been a pre-Ondol[溫突] bedroom, with a Board platform[板房] and a Gomi-ceiling[Gomi-banza] fashion.

A Study on safety against a fire of charging cable for mobile phone for vehicle (자동차용 모바일 폰 충전 케이블의 발화 안전성에 관한 연구)

  • Kwon, Jin-Wook;Choi, Kyu-Sik;Hwang, Myung-Whan
    • Journal of the Korea Safety Management & Science
    • /
    • v.20 no.3
    • /
    • pp.21-26
    • /
    • 2018
  • This paper describes result of a study on safety against a fire of charging cable for mobile phone for vehicle. Combustion on the USB cable in the car was happened while driving. Gas coming from the burning USB cable could be a reason which can make a secondary car accident since the driver also can be embarrassed while driving. In order to prevent a secondary car accident connected on the road, to research a reason why USB cable can emit gas and be burned in charging. We did simulation test with abnormal fault condition for the electronic component on the board in the USB cable. So we get the result from abnormal fault condition simulation test, for instance, shorted test for output terminal of 8 pin switch, shorted test for chip resistor after thermal aging in the condition $25^{\circ}C$, 93 % RH during 48 hours. To analysis the result of all test, Combustion on the USB cable was not the 8 pin but other electrical component such as a chip resistor. Therefore we guess that the reason for USB cable combustion in charging in a car was not 8 pin and a LED but another defective component.

Current status and improvement strategies of emergency medical counseling service for overseas koreans (재외국민 응급의료상담 서비스의 이용 실태 및 서비스 향상방안)

  • Hyeon-Jeong Ko;Eun-Sook Choi
    • The Korean Journal of Emergency Medical Services
    • /
    • v.28 no.1
    • /
    • pp.77-95
    • /
    • 2024
  • Purpose: This study aimed to analyze the counseling status of overseas Koreans using emergency medical counseling services, identify frequently occurring types of diseases, explore approaches to emergency treatment guidance, and protect overseas Koreans from medical blind spots, thereby enhancing the quality of emergency medical counseling services. Methods: This study was approved by the Institutional Review Board of Kongju National University (KNU_IRB_2023-31), and data were collected and analyzed from 10,951 cases of emergency medical counseling services utilized by overseas Koreans from the National Fire Agency from 2018 to 2022. Results: Emergency medical consultation services for overseas Koreans included a majority of non-trauma patients, with medical consultations being predominant. Terrestrial patients commonly seek advice for internal medical symptoms, whereas maritime patients frequently present with trauma-related symptoms, with a higher incidence of cardiac arrest and altered consciousness cases at sea. The development of self-diagnostic tests based on internal medicine symptoms is necessary for terrestrial patients, whereas stakeholder education is required for maritime patients. Conclusion: Due to the different types of diseases occurring in terrestrial and maritime patients, emergency medical consultation services for overseas Koreans should be implemented according to the specific characteristics of each patient. Therefore, it is necessary to develop and disseminate response manuals that are tailored to medical and trauma-related symptoms.

Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation (지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가)

  • 윤명오;고재선;박형주;박성은
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-33
    • /
    • 2001
  • The utility tunnels are the important facility as a mainstay of country because of the latest communication developments. However, the utilities tunnel is difficult to deal with in case of a fire accident. When a cable burns, the black smoke containing poisonous gas will be reduced. This black smoke goes into the tunnel, and makes it difficult to extinguish the fire. Therefore, when there was a fire in the utility tunnel, the central nerves of the country had been paralyzed, such as property damage, communication interruption, in addition to inconvenience for people. This paper is based on the fire occurred in the past, and reenacting the fire by making the real utilities tunnel model. The aim of this paper is the scientific analysis of the character image of the fire, and the verification of each fire protection system whether it works well after process of setting up a fire protection system in the utilities tunnel at a constant temperature. The fire experiment was equipped with the linear heat detector, the fire door, the connection water spray system and the ventilation system in the utilities tunnel. Fixed portion of an electric power supply cable was coated with a fire retardant coating, and a heating tube was covered with a fireproof. The result showed that the highest temperature was $932^{\circ}c$ and the linear heat detector was working at the constant temperature, and it pointed at the place of the fire on the receiving board, and Fixed portion of the electric power supply cable coated with the fire retardant coating did not work as the fireproof. The heating tube was covered with the fireproof about 30 minutes.

  • PDF

The Developmental Device for 119 fire fighting helicopter use activations (119 소방헬기 이용 활성화를 위한 발전방안)

  • Koh, Jae-Moon;Kim, Tae-Min;Kim, Hyo-Sik;Lee, Young-Ah
    • The Korean Journal of Emergency Medical Services
    • /
    • v.11 no.3
    • /
    • pp.93-109
    • /
    • 2007
  • The pre-hospital care in site transportation care and site care will be divided, it will follow in site or evacuation it will enforce it will can evacuate in condition of the emergency patient of like this at the initial stage and emergency care from inside fire fighting helicopter back transfer means and the manpower security of the specialty emergency necessary personnel(nursing and 1st EMT's) as the medical treatment agency and modernization of first aid equipment necessity inside American securing and fire fighting helicopter and specialty first aid packet won about lower the emergency care which is appropriate cannot become accomplished are the actual condition in total lack of emergency care equipment. Consequently craving augmentation, in order to be adapted with the handling kind transfer whose specialty and is appropriate and present time of rapid increase and the citizen of emergency demand by fire fighting helicopter simplicity transfer compared to it is a condition where the countermeasure preparation is earnest. Must expand emergency care equipment first even in fire fighting helicopter and 1st EMT's which it follows in him become arrangement and quickly the execution and specialty temporary disposal(ALS) must be enforced a temporary disposal and must buy the life which is. Also it gets by experience a helicopter induction outline, a radio communication method and the patient helicopter on-board hour attention point back various attention fact back with the body and when where it stands but accurately there must be it will be able to induce the helicopter. Also every manuals anger it does a helicopter transfer method and the emergency care method back and that all processes must do fixed form anger, it becomes feed. Also it related with a helicopter transfer even from the relationship agency many research to lead, difference of the advanced foreign nation and the maximum it is the actual condition where the medical emergency system construction which it reduces is earnestly demanded. Also with emergency structure(crane) it confronts to an aviation transfer even from the establishment college and education it leads intensively and 1st EMT's of the good quality which relates with an aviation structure expects is cultivate at all.

  • PDF

The Study on Improvement for Prevention and Nonproliferation on Infectious Disease Proliferations (감염병 예방 및 확산 방지를 위한 개선방안에 관한 연구)

  • Roh, Tae-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.144-150
    • /
    • 2017
  • The inflow of infectious diseases is increasing due to the expansion of exchanges between countries and climate change. The public concern and anxiety about the increase of the possibility of infectious disease due to the social environment change are increasing greatly.These pandemics are a serious threat to the economy. Hence, multifaceted efforts are required to prevent them from spreading.In many hospitals, it is very important to promptly report infectious diseases, such as the CDC, when infectious diseases occur. In addition, it is difficult to separate general patients and suspected infected patients in these facilities, so there is a high risk of infection spreading within them. The paper presents the improvements of prevention and nonproliferation by researching the occurrence of infectious diseases, the method of separating infected patients, and the methods of preventing infectious diseases based on the audit results of MERS of the Board of Audit and Inspection.

A Study on Safety Awareness and Safety Accident Occurrence of Elementary School Students (초등학생의 안전의식과 안전사고 발생 실태에 관한 연구)

  • Park, Dae-Sung;Kim, Gwang-Seok
    • The Korean Journal of Emergency Medical Services
    • /
    • v.9 no.2
    • /
    • pp.5-20
    • /
    • 2005
  • Purpose: This study is to examine the relationship between safety awareness and safety accident occurrence with elementary school students. Materials and methods: It selected 10 elementary schools under the supervision of Jeonnam Board of Education and sampled 700 students randomly from 2-3 classes in the 5th and the 6th grade. One preliminary survey was conducted to revise and complement the contents and forms of questionnaire with 70 students of a school from Apr. 1 to 6, 2004 and this study was conducted from Apr. 10 to 30, 2004. Total 700 questionnaires were distributed and 681 were collected (97%) and 602 were used for final analysis except 79 lacking responses. Data collected were analyzed with SPSS statistical program. Results: The average score of safety awareness of subjects by area was high as 2.72 points out of a possible 3. Area showing the highest safety awareness was safety from fire. Girl students had higher safety awareness than boy students. The fifth graders had higher safety awareness than the sixth graders. In safety awareness by the number of siblings, single son or single daughter showed the highest safety awareness. 53.2% of the subjects experienced accident for one year, the frequency of accident was mostly once and most of accidents were occurred at school. Accidents for the last year were higher in boy students, the sixth graders. According to relationship between safety awareness and safety accident, group with lower safety awareness in school safety(P < .022), traffic safety(P < .016), fire safety(P < .019), home safety(P < .007) and accident treatment and first aid(P < .003) had higher safety accidents than that with higher safety awareness. Conclusion: Development of safety education program by grade, that of parents safety education program, field experience and practice with students, teachers and parents and various safety education programs should be substantially and repeatedly accomplished for prevention education of safety accidents. In addition, to prevent and cope with safety accidents, safety education should be reflected on normal education, safety education textbook be developed, special safety education teachers be employed for safety education.

  • PDF

Thermal Characteristic and Failure Modes and Effects Analysis for Components of Photovoltaic PCS (태양광 발전 PCS 구성부품에 대한 열적특성 및 고장모드영향분석)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Kim, Yoon-Bok
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.4
    • /
    • pp.1-7
    • /
    • 2018
  • This paper is analyzed for the thermal characteristics(1 year) of the 6 components(DC breaker, DC filter(including capacitor and discharge resistance), IGBT(Insulated gate bipolar mode transistor), AC filter, AC breaker, etc.) of a photovoltaic power generation-based PCS(Power conditioning system) below 20 kW. Among the modules, the discharge resistance included in the DC filter indicated the highest heat at $125^{\circ}C$, and such heat resulting from the discharge resistance had an influence on the IGBT installed on the rear side the board. Therefore, risk priority through risk priority number(RPN) of FMEA(Failure modes and effects analysis) sheet is conducted for classification into top 10 %. According to thermal characteristics and FMEA, it is necessary to pay attention to not only the in-house defects found in the IGBT, but also the conductive heat caused by the discharge resistance. Since it is possible that animal, dust and others can be accumulated within the PCS, it is possible that the heat resulting from the discharge resistance may cause fire. Accordingly, there are two options that can be used: installing a heat sink while designing the discharge resistance, and designing the discharge resistance in a structure capable of avoiding heat conduction through setting a separation distance between discharge resistance and IGBT. This data can be used as the data for conducting a comparative analysis of abnormal signals in the process of developing a safety device for solar electricity-based photovoltaic power generation systems, as the data for examining the fire accidents caused by each module, and as the field data for setting component management priorities.

A Real Time Temperature Monitoring System for Plating Process (도금공정 실시간 원격 온도 모니터링 시스템)

  • Jung, Sun-Wung;Choi, Tae-Lin;Yoo, Woosik;Kim, Byung Soo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.38 no.4
    • /
    • pp.72-79
    • /
    • 2015
  • A number of plating companies have been exposed to the risk of fire due to unexpected temperature increasing of water in a plating bath. Since the companies are not able to forecast the unexpected temperature increasing of water and most of raw materials in the plating process have low ignition temperature, it is easy to be exposed to the risk of fire. Thus, the companies have to notice the changes immediately to prevent the risk of fire from plating process. Due to this reason, an agile and systematic temperature monitoring system is required for the plating companies. Unfortunately, in case of small size companies, it is hard to purchase a systematic solution and be offered consulting from one of the risk management consulting companies due to an expensive cost. In addition, most of the companies have insufficient research and development (R&D) experts to autonomously develop the risk management solution. In this article, we developed a real time remote temperature monitoring system which is easy to operate with a lower cost. The system is constructed by using Raspberry Pi single board computer and Android application to release an economic issue for the small sized plating manufacturing companies. The derived system is able to monitor the temperature continuously with tracking the temperature in the batch in a short time and transmit a push-alarm to a target-device located in a remoted area when the temperature exceeds a certain hazardous-temperature level. Therefore, the target small plating company achieves a risk management system with a small cost.

Study on IoT-based Map Inside the Building and Fire Perception System (IoT 기반 건물 내부 지도 및 화재 안내 시스템에 관한 연구)

  • Moon, Sung-Ryong;Cho, Joon-Ho
    • Journal of Digital Convergence
    • /
    • v.17 no.1
    • /
    • pp.85-90
    • /
    • 2019
  • This paper is a study on IoT based map inside the building and fire perception system using microprocessor and LABVIEW program. The smart control system implemented in this paper is designed to identify the location of fire by using microprocessor, flame detection sensor, carbon monoxide sensor and temperature sensor, and to guide the optimal travel route through Zigbee communication. And the proposed system uses QR code to interoperate with smartphone. The coordinator control verified that the sensor value of the smart control system installed through the LABVIEW software was confirmed. The IoT based control system studied in this paper was implemented with Arduino mega board and LABVIEW software, and the operation status was confirmed by display device and coordination.