Chest Compression Energy(kg) Measurement of 4 Types of Rescue Device on the Floor (4종류의 구급장비 및 마루(Floor) 위에서 시행한 가슴압박 에너지(kg)측정 실험에 관한 연구)

  • Shin, Dong-Min;Han, Yong-Taek;Kim, Seung-Yong;Park, Si-Eun
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.125-131
    • /
    • 2014
  • The purpose of this study is to investigate the effect of high quality CPR using the 4 types of rescue device equipment and chest compressions energy measurement in pre-hospital settings. So, we used the mode to insert load cell in ALS Skill master Manikin to develop CFMM(Compression Force Measurement Manikin) on main stretcher, CPR board, long spine board, scoop stretcher and floor. And, our research team could know that the main stretcher needed average force of 32.55 (${\pm}1.01$) kg, CPR board of 27.23 (${\pm}1.08$) kg, long spine board of 27.13 (${\pm}1.18$) kg, Scoop Stretcher of 27.38 (${\pm}1.05$) kg and Floor of 27.24 (${\pm}0.93$) kg. CPR board must be necessary in the case of CPR on main stretcher in a moving ambulance. But if the condition of patient's back surface is the removable stretcher and the long spine plate, the patient doesn't have to be spent time to use a CPR board. Furthermore, this research suggests to consider that how to take advantage of the education to students for the equipment to check in real time the energy(kg) requirement of chest compressions.

A Experimental Study on Characteristics of the Ignition by Cigarette Light (담뱃불 발화특성에 관한 실험적 연구)

  • Yun, lnsu;Kim, Byungseon;Cho, Won Cheol;Lee, Tae Shik
    • Journal of Korean Society of societal Security
    • /
    • v.1 no.1
    • /
    • pp.81-87
    • /
    • 2008
  • The cigarette holds more than 10 percents of the entire fire accidents despite the number of smokers rapidly decreases every year. The purpose of this study is to examine the ignition characteristics of cigarette by experimentation. This study analyzed the cases of fires inferred that they were caused by cigarette in Incheon during 2006. As the representative ignition materials, corrugated board, gasoline, lacquer thinner, tarpaulin, flexible PVC sheet, and poly ethylene were tested. In this experimentation, the corrugated board was ignited by cigarette. However gasoline, lacquer thinner, tarpaulin, flexible PVC sheet, and poly ethylene were seldom ignited. Meanwhile most fire investigators have argued that oils and tents were ignited by cigarette, but this study experimentally proved that such an argument might be ungrounded.

  • PDF

Analysis of the Risk of Heat Generation due to Bolt Loosening in Terminal Block Connector Parts (볼트풀림에 의한 터미널 블록의 접속부 발열 위험성 분석)

  • Yeon, Yeong-Mo;Kim, Seung-Hee
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.67-75
    • /
    • 2020
  • In this study, the risk of heat generation due to normal and overload currents that vary with the abnormal loosening angle of wire-connecting bolts were identified. The risks were analyzed based on the thermal characteristics to minimize the carbonization accidents of terminal blocks inside distribution panels typically used in industrial sites. We applied a method for measuring the heating temperature and temperature variations in the terminal blocks in real-time by installing a resistance temperature detector sensor board in the terminal block. The experimental results showed that the terminal block model with a low-rated current exhibited a higher heating temperature, thus, confirming the need to select the terminal block capacity based on load currents. Additionally, the higher the rated current of the terminal block with a high-rated current and the higher the degree of loosening, the faster the carbonization point. Such heating temperature monitoring enabled real-time thermal temperature measurement and a step-by-step risk level setting through thermal analysis. The results of the measurement and analysis of carbonization risks can provide a theoretical basis for further research regarding the risk of fire due to carbonization. Furthermore, the deterioration measurement method using the temperature sensor board developed in this study is widely applicable to prevent fires caused by poor electrical contact as well as risk-level management.

A Study on the Burning Characteristics of Interior Boards and Louvers (내장용 판재 및 루버의 연소발열특성 연구)

  • Nam, Dong-Gun;Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.34-39
    • /
    • 2014
  • It is necessary to enhance its availability and reliability of performance based fire design of building with various type of database such as experiments, survey and fire properties and so on. In order to utilize to the performance based fire design, the present study has been performed a series of experiments to investigate the burning characteristics of building materials for two types of interior board and three types of interior louver. The burning test has been also conducted for different thickness because it may show different characteristics of burning behavior such as flame spread rate and flame propagation time. The result shows that the effective heat release per unit mass of interior materials were almost constant with 15.3~16.9 MJ/kg regardless of its thickness while the peak heat release rate and maximum $CO_2$ concentration was varied with thickness.

A System IC for Controlling the Fire Prevention (화재방지제어 시스템 IC)

  • Kim, Byung-Cheul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.4
    • /
    • pp.737-746
    • /
    • 2009
  • In this study, we have developed one chip system IC for preventing the overload, detecting an abnormal conditions, and controlling the fire prevention in the intelligent home appliances. For the purpose, a circuit detectable an electric leak for preventing an electric shock, and a circuit detectable arc that has effect directly on the fire are designed. The circuits designed on every block are verified by comparing simulation with bread-boarding using a standard transistors. The system IC is fabricated by using 34 V 2 metal $1.5{\mu}m$ bipolar transistor process from evaluation results. The electrical performances of IC application circuits and the system IC equipped on PCB board are evaluated. It is confirmed that the system IC is well operated for arc and ground fault(GF) signal.

A Study on Risk Assessment for Fire Onboard a Naval Vessel (해군함정 화재 위험도 평가에 관한 연구)

  • Jeon, Gae-Ryong;Kim, Dong-Jin
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.35-42
    • /
    • 2008
  • With the huge navy projects such KDX-III, LPX, bigger and more complicated vessel constructions are being underway in navy. In this paper, considering these trends, we performed a risk analysis on the navy vessel for the fatality of soldiers on board and presented the risk level with FN curve. Assuming a fire occurs in one of the soldier bedrooms, we established event tree to visualize the possible development scenarios and calculated the fatality for each scenario. The critical condition to survive inside the bedroom was obtained through CFAST program.

Plan for the Development of a Standardized Dummy for Persons in Need of Rescue in a Confined Space (밀폐공간 구조 요구자를 위한 더미 표준화 개발 방안)

  • Choi, Seo-Yeon;Rie, Dong-Ho;Kim, Hyung-Jun
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.4
    • /
    • pp.99-105
    • /
    • 2016
  • This study was conducted to develop a dummy in an environment similar to the human body, to prepare a standard for evaluation and to present the process of the production in order to evaluate the performance of the robot that can detect the persons needing rescue in a confined space, who are difficult for fire-fighting officials to rescue in case of fire and disaster. As a result, a standard for evaluation was developed and standardized into four parts 'Normal,' 'Risk Stage 1,' 'Risk Stage 2' and 'Risk Stage 3'based on the number of breath cycles, carbon dioxide concentration, core temperature and criteria for hearing to recognize the voice. In addition, in order to produce a dummy, fever, breathing capacity and voice output function were compared and analyzed. This study has significance that it built up basic data of the method of producing the actual dummy, by presenting characteristics and controlling methods using the waterproof insulation heating coil for the function, solenoid valve for the consecutive output of breathing capacity and USB program sound board for voice output.

A Study on the Development of a Low-cost Device for Measuring the Optical Smoke Density (광학적 연기밀도 측정을 위한 저가형 장치의 개발에 관한 연구)

  • Kim, Bong-Jun;Cho, Jae-Ho;Hwang, Cheol-Hong;Park, Seul-Hyun
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.81-88
    • /
    • 2015
  • A low-cost device using the light-extinction method was developed to measure the optical smoke density in various fire experiments in the present study. The relative measurement accuracy of low-cost device was evaluated through the comparison of optical density measured by a high-cost standard device consisting of He-Ne laser, photo detector and various optical components. The low-cost device was composed of laser module, photocell and acrylic board. From the experiments using a smoke generator can be easily adjusted the smoke concentration, it was found that the low-cost device could measure the smoke density within the range of ${\pm}10%$, compared to the standard device. In addition, the reliability of low-cost device was also confirmed in the experiment using a polyethylene flame. Finally, it is expected that the low-cost device developed with real-time measurement and simple installation for measuring the smoke density will be used instead of the high-cost standard device.

Habitability evaluation considering various input parameters for main control benchboard fire in the main control room

  • Byeongjun Kim ;Jaiho Lee ;Seyoung Kim;Weon Gyu Shin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4195-4208
    • /
    • 2022
  • In this study, operator habitability was numerically evaluated in the event of a fire at the main control bench board (MCB) in a reference main control room (MCR). It was investigated if evacuation variables including hot gas layer temperature (HGLT), heat flux (HF), and optical density (OD) at 1.8 m from the MCR floor exceed the reference evacuation criteria provided in NUREG/CR-6850. For a fire model validation, the simulation results of the reference MCR were compared with existing experimental results on the same reference MCR. In the simulation, various input parameters were applied to the MCB panel fire scenario: MCR height, peak heat release rate (HRR) of a panel, number of panels where fire propagation occurs, fire propagation time, door open/close conditions, and mechanical ventilation operation. A specialized-average HRR (SAHRR) concept was newly devised to comprehensively investigate how the various input parameters affect the operator's habitability. Peak values of the evacuation variables normalized by evacuation criteria of NUREG/CR-6850 were well-correlated as the power function of the SAHRR for the various input parameters. In addition, the evacuation time map was newly utilized to investigate how the evacuation time for different SAHRR was affected by changing the various input parameters. In the previous studies, it was found that the OD is the most dominant variable to determine the MCR evacuation time. In this study, however, the evacuation time map showed that the HF is the most dominant factor at the condition of without-mechanical ventilation for the MCR with a partially-open false ceiling, but the OD is the most dominant factor for all the other conditions. Therefore, the method using the SAHRR and the evacuation time map was very useful to effectively and comprehensively evaluate the operator habitability for the various input parameters in the event of MCB fires for the reference MCR.

Combustion Characteristics of Car Components Using Cone-Calorimeter (콘 칼로리미터를 이용한 자동차 구성 요소별 연소 특성 분석)

  • Park, Eun-Young;Park, Duck-Shin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.3
    • /
    • pp.237-247
    • /
    • 2009
  • The combustion characteristics of car components have been investigated, The combustion parameters like heat release rate, smoke production, yield of carbon dioxide and carbon monoxide and mass loss rate were analyzed by cone-calorimeter for representative samples (seat, carpet, headrest, rubber mat, dash board and electric wire) collected from a used car. The results from sample combustion showed that cover and sponge in seat more quickly ignited and flamed than other parts. The heat released from the combustion of dash board sample was 144.29$kw/m^2$ and the smoke produced by the wire combustion was 6896.4 $m^2/m^2$. The yields of carbon dioxide and carbon monoxide were in the ranges of 1.09${\sim}$2.76 kg/kg and 0.0262${\sim}$0.1008 kg/kg, respectively.