• Title/Summary/Keyword: Fire Accidents

Search Result 746, Processing Time 0.028 seconds

Prevention for the elderly safety issues to prepare for an aged society (고령화사회대비 노인안전사고 예방방안)

  • Moon, Gee-Sik;Choi, Jung-Kweon;Park, Hee-Jin
    • The Korean Journal of Emergency Medical Services
    • /
    • v.12 no.2
    • /
    • pp.71-84
    • /
    • 2008
  • The usual reasons for elderly safety accidents include lack of care for disaster, physical disability, and an error of judgment and so on. But it is true that accidents will occur continuously with the afore-mentioned causes. Against the elderly safety accidents, safety is the main prerequisite for leading the successful and easy life in the elderly. Therefore, this study is purposed to provide the way of thinking about elderly safety issues by suggesting the methods and contents of education program. This study is specifically focused on developing audio-visual materials involved in all the safety accidents and researching the effect of safety education ability through materials with a view to identify the substantial problems. Education program should make a continuous and long term study so that the curricula of the safety accidents prevention education can be done systematically.

  • PDF

A Study on Fire and Evacuation of TrainingShip HANBADA using FDS (FDS를 이용한 실습선 한바다호 화재 및 피난 연구)

  • KIM, Won-Ouk
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.29 no.2
    • /
    • pp.380-385
    • /
    • 2017
  • Maritime accidents caused by a ship include collisions, sinking, stranding and fire etc. This study is intending to consider fire accidents among such diverse marine accidents. It is much likely that various sorts of fires break out because crews are living in a narrow space for long periods of time consequent on the ship's characteristic of sailing on the sea. This study carried out a simulation through the special program for fire analysis - FDS (Fire Dynamics Simulator) in order to find the effective evacuation time, i.e. life survival time. Particularly, this study did comparative analysis of the influence on the survival of cadets based on the collected simulation data by fire size and sort. As a result of the analysis, It was analyzed the Evacuation Allowable Limit Temperature $60^{\circ}C$ and resulted that there is no influence in evacuation by temperature. In case of visibility analysis, it reached to 5m which is the Evacuation Allowable Limit at 117 seconds under the condition of wood fire in 1MW. When there is Kerosene in 1MW, it took 92.4 seconds to reach by 5m which is the Evacuation Allowable Limit. Theoretical evacuation time for the non-tilted ship was 118.8 seconds in 1MW sized fire so it is shown that the most passengers are met the evacuation safety in case of wood fire. However, the majority of passengers could not be ensured the evacuation safety in Kerosene case.

A Method on Developing 3D/BIM-Based Real Time Fire Disaster Information Management (3D/BIM 기반 기존 건축물 실시간 건물 화재 정보 관리 방안)

  • Bae, Subin;Cha, Heesung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.24 no.2
    • /
    • pp.3-12
    • /
    • 2023
  • Fire accidents in buildings are reported more frequently nowadays. Existing building fire accidents can lead to large-scale accidents as damage to human and physical resources increases over time, so it is necessary to quickly find ways to suppress fires and rescue them. Currently, more attention is being paid to new buildings than the existing buildings. In addition, fire information can not be captured in a real time basis for the buildings. In line with the demands of this technology, this study presents a quick and systematic fire management method to minimize damage caused by fire in buildings. As a way to achieve the purpose of the study, ArduinoTM sensors and ExcelTM and RevitTM-DynamoTM tools have been combined to develop a new fire information management system and develop a real-time 3D visualization model. It is expected to contribute to the real-time smart fire management system by proposing a fire management application as a way to utilize it in the future.

Fire and Explosion Hazards and Safety Management Measures of Waste Plastic-to-Pyrolysis Oil Conversion Process (폐플라스틱 열분해 유화 공정의 화재·폭발 위험성 및 안전관리 방안)

  • Dong-Hyun Seo;Yi-Rac Choi;Jin-Ho Lim;Ou-Sup Han
    • New & Renewable Energy
    • /
    • v.19 no.3
    • /
    • pp.22-33
    • /
    • 2023
  • The number of fire and explosion accidents caused by pyrolysis oil and gas at waste plastic pyrolysis plants is increasing, but accident status and safety conditions have not been clearly identified. Therefore, the aim of the study was to identify the risks of the waste plastic pyrolysis process and suggest appropriate safety management measures. We collected information on 19 cases of fire and explosion accidents that occurred between 2010 and 2021 at 26 waste plastic pyrolysis plants using the Korea Occupational Safety and Health Agency (KOSHA) database and media reports. The mechanical, managerial, personnel-related, and environmental problems within a plant and problems related to government agencies and the design, manufacturing, and installation companies involved with pyrolysis equipment were analyzed using the 4Ms of Machines, Management, Man, and Media, as well as the System-Theoretic Accident Model and Processes (STAMP) methodology for seven accident cases with accident investigation reports. Study findings indicate the need for establishing legal and institutional support measures for waste plastic pyrolysis plants in order to prevent fire and explosion accidents in the pyrolysis process. In addition, ensuring safety from the design and manufacturing stages of facilities is essential, as are measures that ensure systematic operations after the installation of safety devices.

Study on Fire.Explosion Accidents Prediction Model Development of LPG Vaporizer (LPG 기화기의 화재.폭발사고 예측모델개발에 관한 연구)

  • Ko, Jae-Sun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.1
    • /
    • pp.28-36
    • /
    • 2010
  • We have garnered 3,593 data of gas accidents reported for 12 years from 1995, and then analyzed the LPG vaporizer accidents according to their types and causes based on the classified database. According to the results the gas rupture has been the most common accident followed by the release, explosion and then fire accidents, the most frequent accident-occurring sub-cause is LPG check floater faults. In addition, we have applied the Poisson Probability Functions to predict the most-likely probabilities of fire, explosion, release and rupture with the LPG vaporizer in the upcoming 5 years. In compliance with Poisson Probability Functions results, in the item which occurs below 3 "LPG-Vaporizer-Fire", in the item which occurs below 5 "LPG-Vaporizer-Products Faults-Check Floater" and the item which occurs below 10 appeared with "LPG-Vaporizer-Products Faults". From this research we have assured the successive database updating will highly improve the anticipating probability accuracy and thus it will play a key role as a significant safety- securing guideline against the gas disasters.

Preventive Priority Methods Based on the Analysis of Fire Accident Causes in Construction Site (건설현장 화재 발생 요인 분석에 따른 예방우선순위 연구)

  • Kim, Hee-su;Jang, Sang-chul;Joo, Jin-gyu
    • Journal of the Korea Institute of Construction Safety
    • /
    • v.2 no.2
    • /
    • pp.50-55
    • /
    • 2019
  • Currently, safety management is becoming important at domestic construction sites. Despite the importance of safety management, accidents at construction sites are steadily increasing. Fire accidents among safety accidents cause not only negative effects on schedule delay or work plans at construction sites, but also huge casualties. Therefore, the purpose of this research is to extract the causes of fire at the construction site through the case of fire at the construction site, and to prioritize prevention through the analysis of the factors to contribute to the prevention of fire. As a research method, we select fire factors through case, conduct surveys through expert group, and analyze survey through AHP technique. The results of the AHP analysis of the survey of expert groups showed that the workers and their sub-item ranked high. Therefore, the priority for fire prevention was given, and this research is believed to help prevent fire.

A Study on the Fire Risk of the Kimchi Refrigerator through Case Analysis of Fire Accidents (사례 분석을 통한 김치냉장고의 화재 위험성에 관한 연구)

  • Park, Nam Kyu;Ji, Hong Keun;Song, Jae Yong
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.2
    • /
    • pp.1-7
    • /
    • 2020
  • In this paper, we describe fire risk of Kimchi refrigerator. The Kimchi refrigerator has been widely spread and used starting from the first half of 2000 and recently fire accidents caused by the Kimchi refrigerator emerged as social concern. In particular, in products of a specific manufacturer, it is not an environmental factor, but a characteristic that the fire is caused due to a defect of the product itself is shown. These features are judged to be formed by unique defects regardless of external factor by forming electrically arc mark in the relay element. In this paper, we analyzed the cause of the fire occurring in the Kimchi refrigerator and finally confirmed the characteristic that the fire occurred mainly in the relay element due to insufficient capacity of the relay element. Therefore, when a fire occurs in a product of the same maker as the Kimchi refrigerator mentioned in this paper, it is always judged that the inspection of the relay element should be carried out.

A Study on the Method of Resistance Analysis of Water Stream During Fire Supperession (화재진압 시 발생하는 주수 기둥의 저항분석 방법 연구)

  • Jung, Byeong-Sun;Kim, Eung-Sik;Park, Jong-Yeol
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.6
    • /
    • pp.22-27
    • /
    • 2018
  • Fire fighters are exposed to the risk of many accidents during fire suppression, especially near the high voltage circuit. In order to prevent and analyze the electric shock accidents, measurement of water resistance is crucial. However, this has been one of the overlooked research areas and it has been very difficult to measure the mixed up resistance components separately. In this paper, we measured a total resistance of apparatus and regarded it as a serial resistance of contact resistance and length dependant resistance. Measuring the resistance by varying the length of water stream, the variable resistance and fixed contact resistance appear, which are used to calculate the both components of resistances. In addition, the resistance of fire hose can be calculated from the parallel circuit which is formed by grounding the fire hose with the resistance of water stream. Results show that we can successfully measure the resistance per unit length of water stream and fire hose, thereby proving that this method is a facile way to measure water and fire hose resistance. However, many experiments are still required to obtain the precise contact resistance of ground under various condition and the resistance between the human body and fire hose.

Analysis of the Operation of Fire Observers in the Domestic Manufacturing Industry - Focusing on the Revised Occupational Safety and Health Act (국내 제조업 화재감시자 운영 실태 분석 - 개정 산업안전보건법 중심)

  • Kyung Min Kim;Yongyoon Suh;Jong Bin Lee;Seong Rok Chang
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.3
    • /
    • pp.77-84
    • /
    • 2023
  • Welding and cutting, which are representative tasks in handling firearms at industrial sites, are the basis for production and maintenance processes across all industries. They are also essential in the root industry. Specifically, they are widely used in the manufacturing industry, including equipment industries such as shipbuilding, automobiles, and chemicals, and subsequent maintenance work and general facility repair. However, such hot work carries a high fire risk owing to sparks scattering and inadequate management, resulting in a high occurrence of accidents. In response, the government and relevant organizations have recently revised the Occupational Safety and Health Act to prevent accidents during hot work. These revisions impose more stringent regulations than before, which are expected to help prevent actual fire accidents. However, whether the fire observer system, which is the core element of the revision, would be practically applied and maintained is unclear. Therefore, this study compared the fire observer system in the revised Occupational Safety and Health Act with those in the laws and systems of developed countries, conducted interviews with safety and health experts to assess the suitability of the new system for fire observer operations, and improvement plans were derived accordingly. Therefore, the laws and systems of developed countries grant more authority to fire observers compared with those of Korea. Moreover, professional training in handling emergency is required. Interviews with safety and health experts revealed that regardless of company size, the same operating standards were applied, and standards for deploying fire observers in various locations were unclear. Furthermore, there was a lack of professional education and training, and the role and authority of fire observers were limited. These findings revealed a problem in this sector. The results of this study are expected to serve as basic data for establishing a practical system for placing fire observers and supplementing laws, guidelines, and systems for preventing fire accidents.