• Title/Summary/Keyword: Finite ground

Search Result 999, Processing Time 0.027 seconds

A Numerical Study of Mesoscale Model Initialization with Data Assimilation

  • Min, Ki-Hong
    • Journal of the Korean earth science society
    • /
    • v.35 no.5
    • /
    • pp.342-353
    • /
    • 2014
  • Data for model analysis derived from the finite volume (fv) GCM (Goddard Earth Observing System Ver. 4, GEOS-4) and the Land Data Assimilation System (LDAS) have been utilized in a mesoscale model. These data are tested to provide initial conditions and lateral boundary forcings to the Purdue Mesoscale Model (PMM) for a case study of the Midwestern flood that took place from 21-23 May 1998. The simulated results with fvGCM and LDAS soil moisture and temperature data are compared with that of ECMWF reanalysis. The initial conditions of the land surface provided by fvGCM/LDAS show significant differences in both soil moisture and ground temperature when compared to ECMWF control run, which results in a much different atmospheric state in the Planetary Boundary Layer (PBL). The simulation result shows that significant changes to the forecasted weather system occur due to the surface initial conditions, especially for the precipitation and temperature over the land. In comparing precipitation, moisture budgets, and surface energy, not only do the intensity and the location of precipitation over the Midwestern U.S. coincide better when running fvGCM/LDAS, but also the temperature forecast agrees better when compared to ECMWF reanalysis data. However, the precipitation over the Rocky Mountains is too large due to the cumulus parameterization scheme used in the PMM. The RMS errors and biases of fvGCM/LDAS are smaller than the control run and show statistical significance supporting the conclusion that the use of LDAS improves the precipitation and temperature forecast in the case of the Midwestern flood. The same method can be applied to Korea and simulations will be carried out as more LDAS data becomes available.

Frequency Characteristics of the Return Loss of a Broadband Double-Cone Antenna with Shorting Plate (단락판을 갖는 이중 원추형 광대역 안테나의 반사손실 특성)

  • Jang, Seung-Hoon;Hong, Deok-Gi;Kim, Hyo-gyun;Jung, Sung-Woo;Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.2
    • /
    • pp.101-107
    • /
    • 2016
  • This paper presents the characteristics of a double-cone broadband antenna with compact and three-dimensional structure that can be used in UWB system. The theoretical analysis is conducted using a finite difference time domain(FDTD) method. The parameters are the radius, a height of broadband double-cone antennas with shorting plate, and the number of plates on a ground plane. This paper examines influence of structural parameters on return loss. The results show that a condition for an optimum structure of broadband double-cone antennas with shorting plate exists. It also shows that the broadband double-cone antennas with shorting plate have radiation patterns similar to those of a dipole antenna. To verify the theoretical analysis, computed results are compared to experimental results.

Broadband Double-Cone Antennas for Measuring Partial Discharge (부분방전 측정용 이중 원추형 광대역 안테나)

  • Jang, Seung-Hoon;Choi, Beom-jin;Lim, Dong-Young;Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.12
    • /
    • pp.1050-1057
    • /
    • 2015
  • This paper presents the characteristics of broadband double-cone antennas. The antenna is used to measure electromagnetic fields(2~5 GHz) radiated from a primary or a secondary electrode of a pole-transformer when partial discharge occurs inside the pole-transformer. The theoretical analysis is conducted using commercial software based on a finite difference time domain(FDTD) method. The parameters are a radius, and a height of the broadband double-cone antennas, and the number of posts on a ground plane. This paper examines influences of structural parameters of the broadband double-cone antennas on return loss. The results show that a condition for an optimum structure of broadband double-cone antennas exists. It also shows that the broadband double-cone antennas have radiation patterns similar to those of a dipole antenna. Therefore the broadband double-cone antennas are appropriate for the measurement of radiated electromagnetic fields from the pole-transformer. To verify the theoretical analysis, computed results are compared to experimental results.

Characteristics of Soil-Nailing Applied to Extension-Grouting Method (확장그라우팅 공법이 적용된 쏘일네일링의 거동특성)

  • Lee, Hyoungkyu;Lee, In
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.3
    • /
    • pp.53-62
    • /
    • 2010
  • In the early 1990s, it was first introduced the soil nailing method for the slope stability and ground excavation and widely used as method of reinforcement. Also the application of soil nailing has been improved and developed. Most recently used for grout soil nailing greatly improve the methods and techniques for self-improvement techniques are classified as soil nailing. As the representative for the grout pressure method to improve the join method pressure grouting and improved method for the self-drilled soil nailing, removable soil nailing, extension grout method. Three dimensional finite difference analysis was used to evaluate characteristics of pull-out behavior of extension grout method. In this paper, it was described a characteristics of pull-out behavior of soil nailing with extension grout method through the result of numerical method.

Seismic performance evaluation of Pier-Shafts system with multi-layered soil (다양한 지반층을 갖는 Pier-Shafts 시스템의 내진성능평가)

  • Jang, Sung-Hwan;Nam, Sang-Hyeok;Song, Ha-Won;Kim, Byung-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.69-72
    • /
    • 2008
  • The so-called Pier-Shafts system which consists of the continuous column and shaft is often used to support the highway bridge structure because of advantages in easy construction and low cost. In the earthquake region, the Pier-Shafts system undergoes large displacements and represents a nonlinear behavior under the lateral seismic loading. The soil-pile interaction should be considered for more accurate analysis of the Pier-Shafts system. In this study, a transverse response of a reinforced concrete Pier-Shafts system inside multi-layered soil medium is predicted using a finite element program which adopts an elasto-plastic interface model for the interface behavior between the shaft and the soil. Then, seismic analysis is performed to evaluate the performance of Pier-Shafts system under strong ground motion and their results are verified with experimental data.

  • PDF

Nonlinear Seismic Analysis of Hollow Cast-in-place and Precast RC Bridge Columns with Triangular Reinforcement Details (삼각망 철근상세를 갖는 현장타설 및 조립식 중공 철근콘크리트 교각의 비선형 지진해석)

  • Kim, Tae-Hoon;Ra, Kyeong-Woong;Lee, Jae-Hoon;Shin, Hyun Mock
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.6
    • /
    • pp.713-722
    • /
    • 2016
  • The goal of this study was to assess the seismic performance of hollow cast-in-place and precast reinforced concrete bridge columns with triangular reinforcement details. The developed material quantity reduction details are economically feasible and rational, and facilitate shorter construction periods. By using a sophisticated nonlinear finite element analysis program, the accuracy and objectivity of the assessment process can be enhanced. The used numerical method gives a realistic prediction of seismic performance throughout the input ground motions for several hollow column specimens investigated. As a result, triangular reinforcement details were designed to be superior to the existing reinforcement details in terms of required seismic performance.

A Study on the HEC(Hybrid ESE-Conductor) Method for Lightning Protection of Buildings (건축물의 낙뢰보호를 위한 HEC(Hybrid ESE-Conductor) 방식에 관한 연구)

  • Kim, Dong-Jin;Kim, Young-Sun;Lee, Ki-Sik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.146-152
    • /
    • 2008
  • The frequency of lightning is increased due to improbable weather condition and global wanning. This phenomenon increases economical damage as well as human damage. Advanced countries like europe and north america have applied the facility standard of lightning by accumulating a store of quantitative data about lightning research. Lightning facility is composed of the lightning accepting part for induction lightning, ground connected electrode which conducts lightning current. The lightning accepting part is composed of normal rod, horizontal conductor, ESE lightning rod. Moreover, lightning accepting part is taken to use by the method of protection. This paper suggests HEC(Hybrid ESE-Conductor) method which mixes horizontal conductor and ESE lightning rod. This is also discovered by experiment that the starting point of corona discharge current is low, so it is efficient for lightning protection comparing with other methods. Moreover, distribution of electric field is analyzed qualitatively by finite element method. It also results in the relation of the starting point of corona discharge current. Corona discharge current makes minute current about some ${\mu}A$ between the electrodes by the strength of electric field. Also it occurs insulation destruction of gas, and it is developed to the shape of streamer by increase of the strength of electric field. We can find that the initial occurrence of streamer and contact probability of lightning can have advantage after researching the starting point of corona discharge current and discharge current of lightning striking point. This research demonstrates that the suggested HEC method is economically competitive as a lightning protection facility, and it takes a capably perfect role.

Wind-induced responses and dynamic characteristics of a super-tall building under a typhoon event

  • Hua, X.G.;Xu, K.;Wang, Y.W.;Wen, Q.;Chen, Z.Q.
    • Smart Structures and Systems
    • /
    • v.25 no.1
    • /
    • pp.81-96
    • /
    • 2020
  • Wind measurements were made on the Canton Tower at a height of 461 m above ground during the Typhoon Vincente, the wind-induced accelerations and displacements of the tower were recorded as well. Comparisons of measured wind parameters at upper level of atmospheric boundary layer with those adopted in wind tunnel testing were presented. The measured turbulence intensity can be smaller than the design value, indicating that the wind tunnel testing may underestimate the crosswind structural responses for certain lock-in velocity range of vortex shedding. Analyses of peak factors and power spectral density for acceleration response shows that the crosswind responses are a combination of gust-induced buffeting and vortex-induced vibrations in the certain range of wind directions. The identified modal frequencies and mode shapes from acceleration data are found to be in good agreement with existing experimental results and the prediction from the finite element model. The damping ratios increase with amplitude of vibration or equivalently wind velocity which may be attributed to aerodynamic damping. In addition, the natural frequencies determined from the measured displacement are very close to those determined from the acceleration data for the first two modes. Finally, the relation between displacement responses and wind speed/direction was investigated.

Effects of Grid Characteristics on High Speed Circuit Breaker for Railway Vehicle (철도 차량용 직류 고속도 차단기의 그리드 특성 해석)

  • Park, Ji-Won;Jung, Jooyoung;Choi, Jinnil
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.2
    • /
    • pp.117-123
    • /
    • 2016
  • High speed circuit breakers(HSCB) interrupt the generated arc within the arc chute to turn off the electricity flowing through the main circuit to prevent ground faults. In order to explore the arc generated from the contactor operation, arc definition, establishment of arc interruption method, and analysis of magnetic driving force are required. In this paper, arc interruption capability has been estimated by exploring the difference in magnetic flux density of Lorenz forces using finite element analysis. In addition, since the number of grids and changes in the grid shape within the arc chute influence the formation of the inner magnetic field, its effects have been explored to enhance arc interruption capability. Assessment of interruption capability and analysis of grid shape, with rated operating current, are reported.

Slip Effect at the Pile-soil Interface on Dragload (하향력을 받는 말뚝-지반 접촉면의 슬립 효과)

  • Jeong, Sang-Seom;Lee, Cheol-Ju
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.3
    • /
    • pp.65-74
    • /
    • 2003
  • The dragload on pile groups in consolidating ground was investigated based on a numerical analysis. The case of a single pile and subsequently the response of groups were analyzed by 2D and 3D finite element studies. Conventional continuum elements and special slip elements were used in the analyses for comparison. Based on a limited parametric study, it is shown that dragload for a single pile and group effect are normally overestimated by continuum analyses, compared with the predictions by the slip analyses. The group effect was examined from the slip analysis by considering various factors such as pile configurations, surface loading, interface friction coefficient, and axial loading on piles. An examplary analysis and one previous experimental observation of dragload and group effects were back-analysed. The case histories demonstrated that the slip analysis might predict a better estimate of dragload and group effect compared to the no-slip continuum analysis.