• 제목/요약/키워드: Finite Element Analyses

검색결과 2,418건 처리시간 0.025초

Comparison of behavior of high-rise residential buildings with and without post-tensioned transfer plate system

  • Byeonguk Ahn;Fahimeh Yavartanoo;Jang-Keun Yoon;Su-Min Kang;Seungjun Kim;Thomas H.-K. Kang
    • Computers and Concrete
    • /
    • 제31권4호
    • /
    • pp.337-348
    • /
    • 2023
  • Shear wall is commonly used as a lateral force resisting system of concrete mid-rise and high-rise buildings, but it brings challenges in providing relatively large space throughout the building height. For this reason, the structure system where the upper structure with bearing, non-bearing and/or shear walls that sits on top of a transfer plate system supported by widely spaced columns at the lower stories is preferred in some regions, particularly in low to moderate seismic regions in Asia. A thick reinforced concrete (RC) plate has often been used as a transfer system, along with RC transfer girders; however, the RC plate becomes very thick for tall buildings. Applying the post-tensioning (PT) technique to RC plates can effectively reduce the thickness and reinforcement as an economical design method. Currently, a simplified model is used for numerical modeling of PT transfer plate, which does not consider the interaction of the plate and the upper structure. To observe the actual behavior of PT transfer plate under seismic loads, it is necessary to model whole parts of the structure and tendons to precisely include the interaction and the secondary effect of PT tendons in the results. This research evaluated the seismic behavior of shear wall-type residential buildings with PT transfer plates for the condition that PT tendons are included or excluded in the modeling. Three-dimensional finite element models were developed, which includes prestressing tendon elements, and response spectrum analyses were carried out to evaluate seismic forces. Two buildings with flat-shape and L-shape plans were considered, and design forces of shear walls and transfer columns for a system with and without PT tendons were compared. The results showed that, in some cases, excluding PT tendons from the model leads to an unrealistic estimation of the demands for shear walls sit on transfer plate and transfer columns due to excluding the secondary effect of PT tendons. Based on the results, generally, the secondary effect reduces shear force demand and axial-flexural demands of transfer columns but increases the shear force demand of shear walls. The results of this study suggested that, in addition to the effect of PT on the resistance of transfer plate, it is necessary to include PT tendons in the modeling to consider its effect on force demand.

아스팔트 혼합물의 점탄성과 차량의 이동 속도가 포장 거동에 미치는 영향 (Asphalt Concrete Pavement Response to Moving Load and Viscoelastic Property)

  • 조명환;김낙석;서영국
    • 대한토목학회논문집
    • /
    • 제28권4D호
    • /
    • pp.485-492
    • /
    • 2008
  • 본 논문에서는 차량의 주행속도가 아스팔트 포장의 변형률 거동에 미치는 영향을 알아보기 위하여 현장시험을 실시하고 그 결과를 3차원 유한요소해석과 비교, 분석하였다. 한국도로공사 시험도로에서 기층의 두께가 다른 세 단면(A2, A5, A8)을 선정하고, 각 단면별로 세 가지의 주행속도(25, 50, 80km/hr)에 대한 종, 횡방향 변형률을 측정하였다. ABAQUS를 이용한 수치해석에서는 시험차량인 덤프트럭(단축-탠덤축)의 축하중을 단계하중(step loading)으로 모사하였으며, 시험도로 아스팔트 혼합물에 대한 선형 점탄성 물성 계수(E(t))를 적용하여 보다 현실적인 거동해석을 실시하였다. 주어진 시험 조건에서 아스팔트 층 하부에서 측정한 종, 횡방향 변형률의 차이(이방성)는 모든 단면에서 목격되었고, 수치해석결과 차량의 주행속도가 증가함에 따라 임계 지점에서 발생하는 최대 변형률의 크기는 감소하는 것으로 예측되었다. 또한, 최대변형률의 크기도 횡방향 변형률이 종방향 변형률에 비하여 약 27% 정도 작았으며, 차량의 속도가 증가함에 따라 최대 변형률의 감소폭도 횡방향이 약간 큰 것으로 나타났다.

철도교용 프리케스트 바닥판의 온도변화를 고려한 적정한 종방향 프리스트레스 수준의 산정 (Evaluation of Proper Level of the Longitudinal Prestress for the Precast Deck of Railway Bridges Considering the Temperature Change)

  • 전세진;김영진;김성운;김철영
    • 대한토목학회논문집
    • /
    • 제26권3D호
    • /
    • pp.499-509
    • /
    • 2006
  • 프리캐스트 콘크리트 바닥판은 일반적인 현장타설 바닥판과 비교할 때 많은 장점을 가지고 있으며, 최근 국내에서도 도로교의 노후 바닥판 교체 공사 및 신설 도로교에 성공적으로 적용되고 있다. 하지만, 철도교에 프리캐스트 바닥판을 적용하기 위해서는 활하중, 장대레일 종하중, 시제동하중, 온도변화, 건조수축 등 도로교와 철도교의 하중 특성의 차이를 적절히 반영한 설계가 요구되며, 특히 횡방향 이음부의 연속성을 확보하여 일체화시키기 위해 바닥판 내부에 배치한 종방향 텐던의 적정한 프리스트레스 수준을 평가하는 연구가 요망된다. 따라서 본 연구에서는 철도교에 빈번히 적용되는 PSC 합성거더 철도교에 대하여 정밀한 3차원 유한요소해석을 통해 주요 설계하중이 유발하는 바닥판의 종방향 응력을 산정하였다. 그 결과 종방향 인장응력을 유발하는 지배적인 요인은 활하중보다는 바닥판의 온도 저하나 시동하중으로 나타났으며, 특히 온도의 영향은 설계기준상의 제안식 또는 이론식과도 비교해 가며 중점적으로 분석하였다. 종방향 인장응력을 상쇄하여 올바른 구조거동을 유도하기 위한 프리스트레스의 범위를 고찰한 결과, 대상 철도교에 대해 2.4 MPa 이상의 프리스트레스를 도입하는 것이 적정한 것으로 나타났으며 이는 도로교의 경우와 유사한 수준으로 평가되었다.

아치형상의 하현재를 갖는 CFT 트러스 거더의 재료 비선형 해석 (Nonlinear Analysis of CFT Truss Girder with the Arch-shaped Lower Chord)

  • 송나영;정철헌;김영진
    • 대한토목학회논문집
    • /
    • 제29권6A호
    • /
    • pp.625-639
    • /
    • 2009
  • 본 연구에서는 f/L비가 다른 CFT 트러스 거더의 구조거동에 관한 실험 및 해석적 연구를 수행하기 위해서 2개의 실험체를 제작하였고, CFT 트러스 거더의 구조특성을 평가하기 위하여 휨실험을 수행하였다. ABAQUS에 의한 비선형 유한요소해석을 통해서 축력과 모멘트를 받는 CFT 부재의 비선형 재료모델을 비교분석하였다. CFT 부재의 구속 콘크리트 및 강재의 응력-변형률 모델은 많은 연구자들에 의해서 제시되어 왔다. 본 연구에서는 Mander, Sakino, Han, Susantha 및 Ellobody 등이 제안한 구속 콘크리트의 응력-변형률 모델을 적용하여 비선형해석을 수행하였고, 해석결과를 통해서 CFT 트러스 거더의 하중-처짐 관계, 하중-변형률 관계 등을 비교하였다. 하중-처짐 관계에서 Mander와 Susantha의 모델을 적용한 해석결과는 실험결과보다 약 12.0~13.8% 높은 하중을 예측하며, Sakino의 모델은 실험결과보다 약 7.6% 높은 하중을 예측하였다. Han과 Ellobody의 모델은 실험결과보다 약 0.2~1.2% 높은 하중을 예측하여 실험치와 가장 잘 맞는 결과를 보였다. 그러나 각 연구자의 응력-변형률 모델을 적용한 비선형 해석을 통해 산정된 하중-변형률 관계는 하중-처짐 관계와는 반대로 안전측의 결과를 보여 전반적으로 실험치보다 큰 수준의 변형률을 보였다.

Opto-Mechanical Detailed Design of the G-CLEF Flexure Control Camera

  • Jae Sok Oh;Chan Park;Kang-Min Kim;Heeyoung Oh;UeeJeong Jeong;Moo-Young Chun;Young Sam Yu;Sungho Lee;Jeong-Gyun Jang;Bi-Ho Jang;Sung-Joon Park;Jihun Kim;Yunjong Kim;Andrew Szentgyorgyi;Stuart McMuldroch;William Podgorski;Ian Evans;Mark Mueller;Alan Uomoto;Jeffrey Crane;Tyson Hare
    • 천문학회지
    • /
    • 제56권2호
    • /
    • pp.169-185
    • /
    • 2023
  • The GMT-Consortium Large Earth Finder (G-CLEF) is the first instrument for the Giant Magellan Telescope (GMT). G-CLEF is a fiber feed, optical band echelle spectrograph that is capable of extremely precise radial velocity measurement. G-CLEF Flexure Control Camera (FCC) is included as a part in G-CLEF Front End Assembly (GCFEA), which monitors the field images focused on a fiber mirror to control the flexure and the focus errors within GCFEA. FCC consists of an optical bench on which five optical components are installed. The order of the optical train is: a collimator, neutral density filters, a focus analyzer, a reimager and a detector (Andor iKon-L 936 CCD camera). The collimator consists of a triplet lens and receives the beam reflected by a fiber mirror. The neutral density filters make it possible a broad range star brightness as a target or a guide. The focus analyzer is used to measure a focus offset. The reimager focuses the beam from the collimator onto the CCD detector focal plane. The detector module includes a linear translator and a field de-rotator. We performed thermoelastic stress analysis for lenses and their mounts to confirm the physical safety of the lens materials. We also conducted the global structure analysis for various gravitational orientations to verify the image stability requirement during the operation of the telescope and the instrument. In this article, we present the opto-mechanical detailed design of G-CLEF FCC and describe the consequence of the numerical finite element analyses for the design.

Horizontal only and horizontal-vertical combined earthquake effects on three R/C frame building structures through linear time-history analysis (LTHA): An implementation to Turkey

  • Selcuk Bas;Mustafa A. Bilgin
    • Computers and Concrete
    • /
    • 제34권3호
    • /
    • pp.329-346
    • /
    • 2024
  • In this study, it is aimed to investigate the vertical seismic performance of reinforced concrete (R/C) frame buildings in two different building stocks, one of which consists of those designed as per the previous Turkish Seismic Code (TSC-2007) that does not consider the vertical earthquake load, and the other of which consists of those designed as per the new Turkish Seismic Code (TSCB-2018) that considers the vertical earthquake load. For this aim, three R/C buildings with heights of 15 m, 24 m and 33 m are designed separately as per TSC-2007 and TSCB-2018 based on some limitations in terms of seismic zone, soil class and structural behavior factor (Rx/Ry) etc. The vertical earthquake motion effects are identified according to the linear time-history analyses (LTHA) that are performed separately for only horizontal (H) and combined horizontal+vertical (H+V) earthquake motions. LTHA is performed to predict how vertical earthquake motion affects the response of the designed buildings by comparing the linear response parameters of the base shear force, the base overturning, the base axial force, top-story vertical displacement. Nonlinear time-history analysis (NLTHA) is generally required for energy dissipative buildings, not required for design of buildings. In this study, the earthquake records are scaled to force the buildings in the linear range. Since nonlinear behavior is not expected from the buildings herein, the nonlinear time-history analysis (NLTHA) is not considered. Eleven earthquake acceleration records are considered by scaling them to the design spectrum given in TSCB-2018. The base shear force is obtained not to be affected from the combined H+V earthquake load for the buildings. The base overturning moment outcomes underline that the rigidity of the frame system in terms of the dimensions of the columns can be a critical parameter for the influence of the vertical earthquake motion on the buildings. In addition, the building stock from TSC-2007 is estimated to show better vertical earthquake performance than that of TSCB-2018. The vertical earthquake motion is found out to be highly effective on the base axial force of 33 m building rather than 15 m and 24 m buildings. Thus, the building height is a particularly important parameter for the base axial force. The percentage changes in the top-story vertical displacement of the buildings designed for both codes show an increase parallel to that in the base axial force results. To extrapolate more general results, it is clear to state that many buildings should be analyzed.

황해 중동부 제4기 퇴적층의 지음향 특성 (Geoacoustic characteristics of Quaternary stratigraphic sequences in the mid-eastern Yellow Sea)

  • 진재화;장성형;김성필;김현태;이치원;장정해;최진혁;양우헌
    • 한국해양학회지:바다
    • /
    • 제6권2호
    • /
    • pp.81-92
    • /
    • 2001
  • 황해 중동부 해역 ($36^{\circ}00'N{\sim}36^{\circ}45'N$,$\;125^{\circ}00'E{\sim}125^{\circ}45'E$)에 분포하는 퇴적층을 대상으로 획득한 고해상 탄성파탐사자료(에어건, 스파커, SBP)와 심부 시추시료(YSDP 105, ${\sim}$64m 깊이)의 종합분석에 따라, 연구 해역의 층서모델을 설정하고 탄성 -음향 모델링을 수행하였다. 층서모델은 탄성파${\cdot}$${\cdot}$시 층서 단위들을 비교 분석하여 각 지층단위의 음향학적 특성, 퇴적과정, 생성시기를 규명하였다 또한 단위층 형성과정을 해수면 변동과 관련지어 순차층서를 복원하였다. 각 순차층은 육성 또는 천해성 기원이며 조립질의 저해수면 퇴적계와 조석 기원 세립질의 해침-고해수면 퇴적계로 구성되어 있다. 탄성-음향 모델링의 매개변수 산출을 위해, 0.S~90 cm 심도 간격으로 측정된 시추코아의 121 개 평균입도 자료를, Hamilton의 회귀식과 퇴적심도에 따른 변화구배를 이용하여, 전밀도(bulk density)값과 종파속도값으로 변환${\cdot}$계산하였다. 외삽${\cdot}$보정된 121 쌍의 전밀도${\cdot}$종파속도 물성값은 설정된 층서모델에서 제시된 단위층 별로 평균하여 각 단위층의 대표값으로 산출하였다. 퇴적층 내의 탄성-음향 전파 모델링을 위해, 층서모델의 각 단위층에 전밀도와 종파속도의 대표값을 입력 매개변수값으로 부여한 후, 층서 구성 단위층들을 유한요소격자로 분해하였다. 파선추적법의 컴퓨터 모델링 결과, 탄성-음향의 전파는 층서모델을 구성하는 단위층 경계면의 불규칙성과 저속도층의 다수 존재에 의하여 매우 복잡한 음경로를 보이며, 음원의 위치에 따라 탄성-음파의 암영대가 달리 존재함을 확인하였다. 것으로 보아 층 2는 고에너지환경에서 형성되었음을 시사한다. 또한 층 2에서 Al의 증가는 쇄설기원 물질의 유입에 의한 것으로 추정된다. 플라이오세 이후에 형성된 층 1은 치밀한 조직을 보이며, 형성 이후 속성작용을 받지 않았다.선택적으로 분해되는 것으로 여겨진다.두냔 tsuchigae, S. nigripinni morii, M. jeoni, C. splendidus, P. koreanus, C. lutheri, I. koreensis, C. herzi, R. brunneus 등으로 본 종들의 서식 상태는 하천의 오염 정도 및 하천개수와 직접적인 관계가 있으므로 어류서식 환경을 유지시키기 위해서 보다 적극적인 하천 수질관리의 대책과 방안이 수립되어야 될 것으로 사료된다.와 운동, H-R도상에서의 별의 특성과 진화 등이다. 탐구 과정에 대한 학생의 성취도는 비교적 높으므로 이해도가 상대적으로 낮은 영역에 대해 학생의 오답 유형을 참고하여 기본 개념 지도에 보다 관심을 기울일 필요가 있다.Cr은 FW에서 전반적으로 감소하는 경향을 보였지만 SW에서는 실험 초기에 감소하다 24시간 이후에는 증가 후 일정한 양상을 보였다. Pb은 FW에서 전반적으로 감소했지만 SW에서는 초기에 급격히 증가 후 다시 급격히 감소하는 양상을 보였다 Pb 또한 Cu, Cd, As와 마찬가지로 SW1&2에서 제거속도가 가장 빠르게 나타났다. FW 상층수 중 Hg는 시간에 따라 급격히 감소했고, 제거속도는 Fw5&6에서 가장 느렸다. 이러한 결과에 근거할 때 벼가 자라고 있고 이분해성 유기물이 풍부한 FW1&2, FW3&4 토양과 상층수에서는 유기물의 분해 활동이 활발하였지만, 벼가 경작되지 않는 FW5&6과 SW 에서는 유기물이 상대적으로 결핍되어 유기물의 분해활동이 적었을 것으로 판단된다. 한편, 수조에 인위적으로 유기물을 첨가한 경우 박테리아 세포수는 SW1에서 164시간 동안 4배 증가하였으나 SW3과 SW5에서는 각각 2.7배, 1.

  • PDF

원자력발전소의 방사성폐기물 드럼 운반을 위한 볼트체결방식의 두꺼운 철판을 이용한 IP-2형 운반용기의 구조 안전성 해석 및 시험 (Structural Safety Test and Analysis of Type IP-2 Transport Packages with Bolted Lid Type and Thick Steel Plate for Radioactive Waste Drums in a NPP)

  • 이상진;김동학;이경호;김정묵;서기석
    • 방사성폐기물학회지
    • /
    • 제5권3호
    • /
    • pp.199-212
    • /
    • 2007
  • IP-2형 운반용기는 정상운반조건에서의 자유낙하시험 및 적층시험을 수행한 후에 운반내용물의 분산 및 유실이 없어야 하며 외부표면에서의 방사선량률이 20%이상 증가할 수 있는 차폐능력의 상실이 없어야 한다. 본 연구에서는 두꺼운 철판을 구조재로 사용하며 볼트체결방식의 뚜껑을 가진 IP-2형 운반용기에 대한 구조 안전성을 평가하기 위한 해석적인 방안을 제안하였다. 해석적인 방법을 통하여 원자력발전소에서 발생된 방사성폐기물 드럼을 폐기물 처리시설에서 임시저장고까지 운반하기 위한 두 종류의 IP-2형 방사성폐기물 운반용기에 대하여 자유낙하조건에서 운반내용물의 분산 및 유실과 차폐손실이 없음을 확인하였다. 자유낙하조건에서 운반내용물의 분산 및 유실을 평가하기 위하여 최대 볼트단면 평균응력값과 최대 뚜껑열림량을 볼트의 인장강도와 뚜껑부에 존재하는 단차와 비교 평가하였다. 또한 최대 차폐두께 감소량을 이용하여 차폐손실을 평가하였다. 자유낙하조건에 대한 동적충돌해석을 검증하고 구조 안전성을 시험적으로 평가하기 위하여 자유낙하시험을 다양한 방향으로 실시하였다. 자유낙하시험에서는 운반내용물의 분산 및 유실은 볼트체결방식의 뚜껑에서 볼트의 파손 및 플랜지의 변형 등을 검사하여 평가하였으며, 차폐손실은 초음파 두께 측정기를 이용한 차폐두께를 측정하여 평가하였다. 해석에 대한 검증을 위하여 시험에서 취득한 변형률과 가속도를 동일한 위치에서 얻어진 해석결과와 비교하였다. 해석결과는 시험결과에 비하여 보수적인 결과를 보여주므로 해석에서 입증한 IP-2형 방사성폐기물 운반용기의 안전성은 보수적인 결과이다. 마지막으로 유한요소해석을 통하여 적층조건에 대한 IP-2형 방사성폐기물 운반용기는 안전함을 입증하였다.

  • PDF