• Title/Summary/Keyword: Finger1ho

Search Result 108, Processing Time 0.026 seconds

Expression of Yippee-Like 5 (YPEL5) Gene During Activation of Human Peripheral T Lymphocytes by Immobilized Anti-CD3 (인체 말초혈액의 활성화 과정 중 yippee-like 5 (YPEL5) 유전자의 발현 양상)

  • Jun, Do-Youn;Park, Hye-Won;Kim, Young-Ho
    • Journal of Life Science
    • /
    • v.17 no.12
    • /
    • pp.1641-1648
    • /
    • 2007
  • Yippee-like proteins, which have been identified as the homolog of Drosophila yippee protein containing a zinc-finger domain, are known to be highly conserved among eukaryotes. However, their functional roles are still poorly understood. Recently we initiated ordered differential display (ODD)-polymerase chain reaction (PCR) to isolate genes of which expressions are altered following activation of human T cells. On the ODD-PCR image, one PCR-product detected in unstimulated T cells was not detectable at the time when the activated T cells traversed near $G_1/S$ boundary following activation by immobilized anti-CD3. Cloning and nucleotide sequence analysis revealed that the PCR-product was yippee-like 5 (YPEL5) gene, which was known as a human homolog of the Drosophila yippee gene. Northern blot analysis confirmed the amount of ${\sim}2.2$ kb YPEL5 mRNA expression detectable in unstimulated T cells was sustained until 1.5 hr after activation and then rapidly declined to undetectable level by 5 hr. Ectopic expression of YPEL5 gene in human cervix epitheloid carcinoma HeLa cells caused a significant reduction in cell proliferation to the level of 47% of the control. Expression of GFP-YPEL5 fusion protein in HeLa cells showed its nuclear localization. These results demonstrated that the expression level of human YPEL5 mRNA was negatively regulated in the early stage of T cell activation, and suggested that YPEL5 might exert an inhibitory effect on the cell proliferation as a nuclear protein.

A STUDY ON FRACTURE STRENGTH OF COLLARLESS METAL CERAMIC CROWN WITH DIFFERENT METAL COPING DESIGN (금속코핑 설계에 따른 Collarless Metal Ceramic Crown의 파절강도에 관한 연구)

  • Yun, Jong-Wook;Yang, Jae-Ho;Chang, Ik-Tae;Lee, Sun-Hyung;Chung, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.454-464
    • /
    • 1999
  • The metal ceramic crown is currently the most popular complete veneer restoration in dentistry, but in many cases, the metal cervical collar at the facial margin is unesthetic and unacceptable. Facial porcelain margin has been used in place of it. But this dose not solve the problems, such as dark gingival discoloration and cervical opaque reflection of porcelain veneer. Recently, metal copings which were designed to terminate its labio-cervical end on the axial walls coronal to the shoulder have been clinically used to solve the esthetic problem of metal ceramic crown. But in this design, porcelain veneer of labio-cervical area which is not supported by metal may not be able to resist the stress during cementation and mastication. The purpose of this study was to evaluate fracture strength and fractured appearance of crowns according to different coping designs. A resin maxillary left central incisor analogue was prepared for a metal ceramic crown, and metal dies were made with duplication mold. Metal copings were made and assigned to one of four groups based on facial framework designs: group 1, coping with 0.5mm metal collar; group 2, metal extended to the shoulder; group 3, metal extended to 1mm coronal tn the shoulder: group 4, metal extended to 2mm coronal to the shoulder. Copings and crowns were adjusted to be same size and thickness, and cemented to metal dies with zinc phosphate cement by finger pressure. Fracture strength was measured with Instron Universal Testing Machine. Metal dies were anchored in Three-way-vice at 3mm below finish line and at $130^{\circ}$ inclined to the long axis of the crown. Load was directed lingually at 2mm below midincisal edge. Load value at initial crack and at catastrophic fracture was recorded. The results obtained were as follows : 1. Fracture strength values at initial crack were higher in groups 1, 2 than in groups 3, 4 but this difference was not statistically significant(P<0.05). 2. Conventional metal collared crown had greater catastrophic fracture strength than any other collarless crowns. 3. The greater the labial metal coping reduction, the lower the catastrophic fracture strength of crowns but when more than 1mm of labial metal reduction was done, the difference in strengths was not statistically significant(p<0.05). 4. The strongest collarless coping design was group 2.

  • PDF

A Study on Children Suffering from Cerebral Palsy in Terms of ADL Evaluation (일상생활동작 평가를 통한 뇌성마비아동에 대한 연구)

  • Park Youn-ki;Lim Ho-Chan;Ahn Byung-Jub;Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.1 no.1
    • /
    • pp.27-45
    • /
    • 1989
  • This study aims at helping cerebrally palsied children to overcome and minimize their sufferings, inducing them to perform ordinary activities of daily living for themselves by coducting ADL Tests which are fundamental activities in daily life and presenting treatment plan for their overall rehabilitation and basic data for achieving the training objective. For that purpose, 173 cerebrally palsied children were selected and given ADL performance Tests from Dec. 1987 to Oct. 1988 and the following results were obtained. 1. Correlation coefficients for each ADL category indicated significant statistical value at .01 level. 2. Correlation coefficient between school-year variable and ADL category variable was significant at .01 level. 3. Correlation between age variable and ADL variable category proved significant at .01 level as well. 4. Correlation coefficients between each category in terms of functional state of extremities were significant at .01 level. 5. The difference in ADL achievements between each category by school year were as follows ; 1) In the category of meeting nature's tall, the age span of more than 4 school years showed statistical significance. 2) In the category of putting off and on clothing, the age span of 3 school years indicated statistical significance. 3) In taking meals statistical significance was found in the age span of 4 school years. 4) In finger movements the age span of more the 4 school years indicated statistical significance. 5) In walking activities statistical significance was noticed in the age span of 2 or 3 school years. Besides, in category by school year, and exceptional case was noticed that the 6th graders were lower than the 5th graders in self-reliance rate. 6. the difference in ADL achievements by type of palsy, children of triplegia were the lowest, while those of monoplegia were the highest. 7. The difference in ADL achievements by kind of palsy, patients of athetosis showed lower rate of self-reliance than those of spasticity, and particularly the latter showed a high rate of self-reliance in taking meals$(83.5\%)$. The former were relatively low in self-reliance and lowerst in meeting nature's call $(59.8\%)$.

  • PDF

Effect of the Brachial Plexus Block and Stellate Ganglion Block on Skin Temperature of the Upper Extremity (성상신경절 차단술과 상완신경총 차단술이 상지 피부온에 미치는 영향)

  • Sim, Kyu-Ho;Tae, Il-San;Rhyu, Ji-Han;Chun, Byung-Don;Lee, Hoo-Jeon;Lee, Sin-Woo
    • The Korean Journal of Pain
    • /
    • v.9 no.2
    • /
    • pp.340-343
    • /
    • 1996
  • Background: In our hospital, stellate ganglion block(SGB) has been performed for the prevention and treatment of vasospasm after microscopic reimplantation of finger(s). If brachial plexus block(BPB) has the same effect of sympathetic block on the upper extremity as SGB, it may be preferable to the SGB because it povides postoperative analgesia and is administered continuously. So we measured and compared the change of skin temperature on the forearm as the parameter of sympathetic blockade after SGB and BPB. Methods: The forty-two patients, belonged to ASA class 1~2, were received BPB for hand surgery. The skin temperature was measured before and after BPB on the forearm with patient monitor(LN 6199, YSI 400 Series Temperature Probe, Hellige, Germany). After 24 hours, ipsilateral SGB was performed and skin temperature was recorded before and after SGB. Results: The increase of skin temperature after procedures was $1.1{\pm}0.5^{\circ}C$(from $34.5{\pm}0.7^{\circ}C$ to $35.6{\pm}0.5^{\circ}C$) in BPB and $0.6{\pm}0.3^{\circ}C$(from $34.9{\pm}0.5^{\circ}C$ to $35.5{\pm}0.5^{\circ}C$) in SGB. The changes of skin temperature in both blocks were statistically significant(p<0.01), and the skin temperatures after each procedure were revealed no significant difference(p$\simeq$0.62). Conclusion: We thought that BPB produced sympathetic blockade on the upper extremity as much as SGB. Moreover, it provides postoperative pain relief and may be employed as continuous BPB could be used for hand surgery with many advantages.

  • PDF

COMPARATIVE STUDY ON THE FRACTURE STRENGTH OF EMPRESS 2 CERAMIC AND TARGIS-VECTRIS CROWN

  • Cha Young-Joo;Yang Jae-Ho;Lee Sun-Hyung;Han Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.599-610
    • /
    • 2001
  • Due to an increasing interest in esthetics and concerns about toxic and allergic reactions to certain alloys, patients and dentists have been looking for metal-free tooth-colored restorations. Recent improvement in technology of new all-ceramic materials and composite materials has broadened the options for esthetic single crown restorations. The aim of this investigation was to study the fracture strength of the metal-free posterior single crowns fabricated using two recently introduced systems, Empress 2 ceramic and Targis-Vectris. Forty premolar-shaped stainless steel dies with the 1mm-wide circumferential shoulder were prepared. Ten cylindrical crowns having a diameter of 8.0mm and total height of 7.5mm were fabricated for each crown system respectively(PFM, Empress staining technique, Empress 2 layering technique, and Targis- Vectris). The crowns were filled with cement and placed on the stainless steel dies with firm finger pressure. The crowns were then stored in distilled water at room temperature for 24 hours before testing. The crowns were tested for fracture strength in an Instron universal testing machine (Instron 6022). With a crosshead speed of 1mm/min the center of the occlusal surface of the crown was loaded using a 4-mm-diameter stainless steel ball until fracture occurred. The fracture surfaces of the crowns were gold coated and examined using scanning electron microscopy(Jeol JSM-840 Joel Ltd., Akishima, Tokyo, Japan). Within the parameters of this study the following conclusions were drawn: 1. The mean fracture strength for PFM crowns was 5829(${\pm}906$)N; for Empress staining technique the fracture strength was 1697(${\pm}604$)N; for Empress 2 Layering technique the fracture strength was 1781N(${\pm}400$)N, and the fracture strength for Targis- Vectris was 3093(${\pm}475$)N. 2. The fracture strength of the PFM crowns was significantly higher than that of the Empress 2 and the Targis-Vectris crowns (P<0.05). 3. The fracture strength of the Targis-Vectris crowns was significantly higher than that of the Empress 2 crowns (P<0.05). 4. No statistical difference was found when Empress staining technique was compared with Empress 2 layering technique. 5. The SEM image of fracture surface of Empress 2 crown showed a very dense microstructure of the lithium disilicate crystals and the SEM image of fracture surface of Targis-Vectris crown showed indentations of Vectris and some fibers tom off from Vectris.

  • PDF

SMITH-MAGENS SYNDROME (SMS) : A CASE REPORT (Smith-Magenis Syndrome (SMS) 환아의 증례 보고)

  • Kim, Eun-Young;Lee, Keung-Ho;Choi, Yeong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.341-347
    • /
    • 2003
  • Smith-Magenis syndrome (SMS) is a clinically recognizable multiple congenital anomaly and mental retardation syndrome caused by an interstitial deletion of chromosome 17 p11.2. Physical features include short stature, characteristic facial appearance: flattened mid-face, down-turned mouth, prominent and often rosy cheeks; prominent jaw in older children and adults, chronic ear infections, hearing impairment, eye problems, including: strabismus (an eye which turns in or out) and myopia (nearsightedness), hoarse voice, short fingers and toes, heart defects or murmurs, problems related to the urinary system, scoliosis (curvature of the spine), an unusual gait (walking pattern), and decreased sensitivity to pain. Behavioral and developmental characteristics include speech delay and articulation problems, developmental delay, learning disability, mental retardation, hyperactivity, self-injury, including: head banging; hand biting; picking at skin, sores and nails; pulling off finger- and toenails; inserting foreign objects into ears, nose, or other body orifices, explosive outbursts, prolonged tantrums, destructive and aggressive behavior, excitability, arm hugging or hand squeezing when excited. This report is the case of a Korean 3-year-3-month old male with Smith-Magenis syndrome referred from local clinic for the treatment of dental caries. The patient was treated by physical restraint after prophylatic administration of antibiotic(Amoxacillin 50mg/kg).

  • PDF

Cardiovascular Responses over the Time Course during Muscle Group III Stimulation in Prehypertensive Individuals (고혈압 전단계자들에 대한 골격근 Group III 자극 시 시간에 따른 심혈관 반응)

  • Park, Won-Il;Park, Si-Young;Choi, Hyun-Min;Lee, Joon-Hee;Jeon, Jong-Mok;Kim, Jong-Kyung;Shim, Jae-Kun;Nho, Ho-Sung
    • Journal of Life Science
    • /
    • v.19 no.11
    • /
    • pp.1568-1574
    • /
    • 2009
  • The purpose of this study was to investigate whether group III muscle afferents play an important role eliciting abnormal blood pressure response mediated during passive muscle stretch in prehypertensive individuals. Eleven middle-aged prehypertensive men (average BP 133/80 mmHg) and nine middle-aged normotensive men (average BP 119/74 mmHg) participated in this study. After 1 min rest baseline data collection, the subject's foot was flexed (dorsiflexion) by an automated cybex for one minute. Systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial blood pressure (MAP), heart rate, stroke volume, cardiac output, and total peripheral resistance were continuously measured on a beat-by-beat basis from a finger via a Finapres device for 1 minute. To evaluate the role of mechanoreflex, a component of exercise pressor reflex, SBP, DBP, and MAP responses over the course of time were examined. The results showed that the pressor response mediated by the muscle mechanoreflex was faster in prehypertensive individuals compared to the normotensive individuals. The substantial pressor response was observed within mean 20 sec of the onset of passive stretch in prehypertension, while mean 45 sec in normotension (p<0.05). It is concluded that excessive pressor response produced during exercise in prehypertension may be due to the dysfunction of the mechano-receptors.

Radiological Projection for Diagnosis of Shoulder Subluxation in Patients with Post-Stroke Hemiplegia (편마비 환자에서의 견관절 아탈구 진단에 유용한 촬영법)

  • Cho, Kwang-Ho;Kang, Yeong-Han
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.253-259
    • /
    • 2009
  • Purpose : The purpose of this study was to find out useful radiological projection of shoulder subluxation in patients with post-stroke hemiplegia. Methods : A total of 33 patients with post-stroke hemiplegia were included(20 men and 13 women, mean age 62.3 years) and having the subluxed shoulder over one finger breath. The shoulder subluxation was determined as the ratio of the radiographic vertical and horizontal distance. The vertical distance was determined by measuring the distance between the most inferolateral point of the acromion and the central point of the humeral head. The horizontal distance was determined by measuring the distance between the central point of the glenoid fossa and the central point of the humeral head. To measure of the shoulder subluxation, the shoulder AP, axial and transthoracic lateral projections were taken on both affected and unaffected shoulders. We analyzed the difference of subluxation distance by t-test. Results : When patients was in sitting position, the average time of being shoulder subluxation was 123 second. There was significant difference between supine($49.90{\pm}13.6\;mm$) and sitting position($60.72{\pm}16.3\;mm$) in the vertical distance of shoulder anterior-posterior projection. Also, there was significant difference on transthoracic lateral projections, Affected $35.92{\pm}6.2\;mm$, Unaffected $28.76{\pm}5.4\;mm$. But in case of shoulder axial projection(supine position), there was no significant difference (Unaffected and affected was $23.01{\pm}9.0\;mm$, $22.45{\pm}8.2\;mm$ each). Conclusion : Radiological projection of shoulder subluxation has diagnostic value when it goes after check out the process of subluxation through finger breadth test. For this, patients must be in sitting and shoulder neutral position about 2 minutes. In addition, Shoulder anterior-posterior and transthoracic projection were significant to diagnose subluxation. But in axial projection, there wasn't meaningful differences.

  • PDF

Evidence of Cortical Reorganization in a Monoparetic Patient with Cerebral Palsy Detected by Combined Functional MRI and TMS

  • Kwon, Yong-Hyun;Jang, Sung-Ho;Lee, Mi-Young;Byun, Woo-Mok;Cho, Yoon-Woo;Ahn, Sang-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.22 no.1
    • /
    • pp.96-103
    • /
    • 2005
  • The motor recovery mechanism of a 21-year-old male monoparetic patient with cerebral palsy, who had complained of a mild weakness on his right hand since infancy, was examined using functional Magnetic Resonance Imaging (fMRI) and Transcranial Magnetic Stimulation (TMS). The patient showed mild motor impairment on the right hand. MRI located the main lesion on the left precentral knob of the brain. fMRI was performed on this patient as well as 8 control subjects using the Blood Oxygen Level Dependent technique at 1.5 T with a standard head coil. The motor activation task consisted of finger flexionextension exercises at 1 Hz cycles. TMS was carried out using a round coil. The anterior portion of the coil was applied tangentially to the scalp at a 1.0 cm separation. Magnetic stimulation was carried out with the maximal output. The Motor Evoked Potentials (MEPs) from both Abductor Pollicis Brevis muscles (APB) were obtained simultaneously. fMRI revealed that the unaffected (right) primary sensori-motor cortex (SM1), which was centered on precentral knob, was activated by the hand movements of the control subjects as well as by the unaffected (left) hand movements of the patient. However, the affected(right) hand movements of the patient activated the medial portion of the injured precentral knob of the left SM1. The optimal scalp site for the affected (right) APB was located at 1 cm medial to that of the unaffected (left) APB. When the optimal scalp site was stimulated, the MEP characteristics from the affected (right) APB showed a delayed latency, lower amplitude, and a distorted figure compared with that of the unaffected (left) APB. Therefore, the motor function of the affected (right) hand was shown to be reorganized in the medial portion of the injured precentral knob.

  • PDF

A Relationship between $2^{nd}$ to $4^{th}$ Digit Length Ratio and Aggression Related-Sports Entries Characteristics in Female Athletics of Korean National Teams (여자 국가대표 선수의 검지-약지 비와 공격성 연관 종목 특징의 관계)

  • Shin, A Young;Lee, Yu Sang;Chae, Jeong Ho
    • Korean Journal of Biological Psychiatry
    • /
    • v.17 no.1
    • /
    • pp.37-43
    • /
    • 2010
  • Objectives : The $2^{nd}$ to $4^{th}$ digit length ratio(2D : 4D) is a sexually dimorphic trait regardless of ethnicity and shows sex differences. According to previous research, men usually have a relatively shorter $2^{nd}$ digit than $4^{th}$ digit. There is tendency that men with lower 2D : 4D are perceived as being more masculine and tend to perform better in some physical sports. Furthermore, 2D : 4D is negatively associated with trait aggression. In this study, we examine gender difference of 2D : 4D and compare 2D:4D of female Korean national team members to 2D : 4D of control subjects. Besides that, we also compare 2D : 4D of female Korean national team members according to their sports entries. Methods : The sample of this study is 396 people, 67 female Korean national team member, 216 control women and 113 control men. We measured $2^{nd}$ to $4^{th}$ digit length of their right hand. In addition, we collected demographic information of female Korean national team members using a self-report questionnaire. Results : The mean 2D : 4D of female Korean national team members is 0.96(SD=0.04), smaller than control women's 2D : 4D(0.97, SD=0.03) and significantly higher than control men's 2D : 4D(0.95, SD=0.03). We also found differences between control men and women. Non-martial arts related sports athletes have significant difference with control men in 2D : 4D. However, martial arts related sports athletes' 2D : 4D is not significantly different from other groups, including control men. Conclusion : These results are consistent with the findings of previous research that there is a significant difference between men and women in their 2D : 4D. Furthermore, 2D : 4D of martial arts related sports athletes have not shown any difference from the 2D : 4D of control men that 2D : 4D of non-martial arts related athletes have shown. This fact is important in consideration of masculine characteristics. For further research, it is necessary to examine 2D : 4D difference according to sport ability and gender differences.