• Title/Summary/Keyword: Finger Pressure

Search Result 138, Processing Time 0.027 seconds

Effects of Venesection at the Sybsun-points on Blood Pressure and Body Temperature in Patients with Stroke (중풍환자에 있어 십선용사혈이 혈압 및 체온에 미치는 영향)

  • 이경진;구본수;김영석;강준권;문상관;고창남;조기호;배형섭;이경섭
    • The Journal of Korean Medicine
    • /
    • v.21 no.1
    • /
    • pp.62-67
    • /
    • 2000
  • Background and Purpose: Sybsun-points are located at the tips of all fingers, 0.1chon from the finger nails, totaling 10 points on both hands. These points have been used for emergency care, fainting, epilepsy, cerebrovascular accidents, hypertension, unconsciousness, high fever etc. The most common technique is bleeding with a needle at these points. Hypertension and fever are the main factors for stroke patients’progress. We investigated whether venesection at Sybsun-points has effects on blood pressure and body temperature in stroke patients. Materials and Methods: 79 stroke patients were enrolled in this study from 1 Jan. 1999 to 30 Sep. 1999. All of them were admitted in Kyunghee University, Hospital of Oriental Medicine. Among them, 62 patients were hypertensive people, 17 were normal. Among the hypertensive patients, 27 were stage 1,20 were stage 2, 15 were stage 3 by classification of JNC 1997. All of the hypertensive patients had been taking drugs, while the normal group did not. From 2pm to 3pm, every 30 minutes we checked patients' blood pressure and body temperature by 24ABPM and tympanic thermometer. After 30 minutes passed, we phlebotomized patients Sybsun-points with Samneung needle 2-3cc of blood. Right after the bleeding, we checked blood pressure and body temperature. After the bleeding, for the next hour and a half, we checked each patient’s blood pressure and body temperature every thirty minutes, or a total of three times. We compared the blood pressure and the body temperature before and after treatment(p<0.05). Results: 1. Venesection at Sybsun-points significantly decreased systolic blood pressure on stage 3 hypertensive patients(p<0.0l). 2. Venesection at Sybsun-points significantly decreased diastolic blood pressure on stage 3 hypertensive patients(p<0.05) 3. Venesection at Sybsun-points had no effect on the change of body temperature. Conclusions: Though further study is needed, our findings suggest that Venesection at Sybsun-points may alleviate hypertension in stroke patients.

  • PDF

An instrumented Glove for Grasp specification in virtual reality based point-and-direct telerobotics

  • Yun, Myung-Hwan;Cannon, David;Freivalds, Andris
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1996.04a
    • /
    • pp.141-146
    • /
    • 1996
  • Hand posture and force, which define aspects of the way an object is grasped, are features of robotics manipulation. A means for specifying these grasping "flavors" has been developed that uses an instrumented glove equipped with joint and force sensors. The new grasp specification system is being used at the Pennsylvania State University (Penn State) in a Virtual Reality based Point-and-Direct(VR-PAD) robotics implementation. In the Computer Integrated Manufacturing (CIM) Laboratory at Penn State, hand posture and force data were collected for manipulating bricks and other items that require varying amounts of force at multiple pressure points. The feasibility of measuring desired grasp characteristics was demonstrated for a modified Cyberglove impregnated with FSR (Force Sensitive Resistor) pressure sensors in the fingertips. A joint/force model relating the parameters of finger articulation and pressure to various lifting tasks was validated for the instrumented "wired" glove. Operators using such a modified glove may ultimately be able to configure robot grasping tasks in environments involving hazardous waste remediation, flexible manufacturing, space operations and other flexible robotics applications. In each case, the VR-PAD approach improved the computational and delay problems of real-time multiple-degree-of-freedom force feedback telemanipulation.ck telemanipulation.

  • PDF

Effect of Heat Flux on the Melting Efficiency and Penetration Shape in TIG Welding (TIG 용접에서 열유속이 용융효율과 용입형상에 미치는 영향)

  • Oh, Dong-Soo;Cho, Sang-Myung
    • Journal of Welding and Joining
    • /
    • v.27 no.2
    • /
    • pp.44-50
    • /
    • 2009
  • The characteristics of arc pressure, current density and heat flux distribution are important factors in understanding physical arc phenomena, which will have a marked effect on the penetration, size and shape of a weld in TIG welding. The purpose of this study is to find out the effect of the heat flux on the melting efficiency and penetration shape in TIG welding using the results of the previous investigators. The conclusions obtained permit to draw a proper method which derived the heat flux distributions by arc pressure distribution measurements, but previous researchers calculated heat flux and current distribution with the heat intensity measurements by the calorimetry. Heat flux of Ar gas arc was concentrated at the central part and distributed low from the arc axis to the radial direction, that of He mixing arc was lower than that of Ar gas, and it was wide distributed to radial direction. That showed a similar characteristic with the Nestor's by calorimetry calculated values. Throughout heat flux drawn in this study was discussed melting efficiency and penetration shape on Ar gas and He mixing gas arc.

An instrumented glove for grasp specification in virtual reality based point-and-direct telerobotics

  • Yun, Myung Hwan;Cannon, David;Freivalds, Andris
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.165-176
    • /
    • 1996
  • Hand posture and force, which define aspects of the way an object is grasped, are features of robotic manipulation. A means for specifying these grasping "flavors" has been developed that uses an instrumented glove equipped with joint and force sensors. The new grasp specification system is being used at the Pennsylvania State University (Penn State) in a Virtual Reality based Point-and-Direct (VR-PAD) robotics implementation. In the Computer Integrated Manufacturing (CIM) Laboratory at Penn State, hand posture and force data were collected for manipulating bricks and other items that require varying amounts of force at multiple pressure points. The feasibility of measuring desired grasp characteristics was demonstrated for a modified Cyberglove impregnated with FSR (Force Sensitive Resistor) pressure sensors in the fingertips. A joint/force model relating the parameters of finger articulation and pressure to various lifting tasks was validated for the instrumented "wired" glove. Operators using such a modified glove may ultimately be able to configure robot grasping tasks in environments involving hazardous waste remediation, flexible manufactruing, space operations and other flexible robotics applications. In each case, the VR-PAD approach improved the computational and delay problems of real-time multiple- degree-of-freedom force feedback telemanipulation.

  • PDF

Analysis of Motion and Pressure for Circular Friction Massage (전문수기마사지 동작 중 원형강찰법에 대한 동작 및 가압력 분석)

  • Kim, Y.H.;Ryu, J.S.;Son, J.S.;Hwang, S.H.;Sohn, R.H.;Cha, I.H.;Song, J.H.;Song, S.J.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.6
    • /
    • pp.487-493
    • /
    • 2010
  • In this study, the circular friction massage technique was performed on the trapezius, the levator scapulae, and the deltoid muscles to collect the information on massage pressures and positions, and thus to utilize it in professional massage system design. Massage motion was measured with the 3-D motion capture system and finger pressures were simultaneously obtained with grip sensors. Massage motions, pressure patterns, and pressure times were different on each muscle, and the motion trajectory was similar to the ellipsoidal shape. The trapezius had higher pressure, longer massage time, and larger impulse than other muscles. These results could be useful to design a massage system based on biomechanical analysis. In order to improve massage effect, it is also strongly recommended that the tip of the system be similar with that of a human thumb in shape and material.

Method for Determining the Deficient and Solid Pulse with a New Pulse Wave Parameter (새로운 맥상 파라메터를 이용한 허실맥 판단 방법)

  • Kim, Sung-Hun;Kim, Jae-Uk;Jeon, Young-Ju;Kim, Keun-Ho;Kim, Jong-Yoel
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.24 no.1
    • /
    • pp.42-47
    • /
    • 2010
  • The pulse diagnosis is an important method in Oriental Medicine. Recently, there have been continuous attempts to replace the finger palpation by Oriental medical doctors (OMDs) by more objective tools based on machines, e.g., pulse analyzers. To improve the performance of the pulse analyzers, both the machine-appropriate interpretations for the pulse images appeared in the literature and the improvement in the repeatability and reproducibility of the measurement sensors are to be developed. As an attempt towards the transformation of the pulse images in terms of machine-appropriate language, in this work, we suggest an upgraded algorithm for the solid/deficient pulses, which are the two representative pulse images informing us how strong the pulse pressure is. It has been argued that one could determine the solid/deficient pulses by the maximum pulse pressure from pulse analyzers. However, by a clinical test, we found that the maximum pulse pressure alone is not sufficient to determine the solid/deficient pulses. In addition to the maximum pulse pressure, the mean pulse pressure averaged over for five different hold-down pressures(3-D MAC) is needed to improve the agreement with the OMD's decision for the solid/deficient pulse. We found that, among the data diagnosed with having either the solid pulse or deficient pulse by OMDs, the novel algorithm showed 86.0% diagnosis rate and 81.6% concordance rate.

A study on the erosive wear of spray tip nozzle by epoxy primer paint impingement and the spraying characteristics (에폭시 프라이머 도료의 에어리스 스프레이 분사 시간에 따른 팁 노즐 침식마모경향과 분사특성 연구)

  • Kim, Jinuk;Cho, Yeon-Ho;Cheon, Je-Il;Han, Myoung-Soo
    • Corrosion Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.59-63
    • /
    • 2015
  • Airless spray which is widely used for painting to ship blocks and hull sides is the coating method for attaching atomized paint material to the substrate using spray tip nozzle with compressed air. When the paint material which has high solid contents such as epoxy primer paint is atomized by passing through spray tip nozzle with high pressure, the nozzle composed of tungsten carbide(WC) undergoes the erosive wear, leading to widening of nozzle hole. The deformation of nozzle hole induces improper spray pattern and coating failures such as finger pattern and sagging because the conditions of spray pump pressure and paint flow rate for developing full spray pattern are changed. In this study, an appropriate replacement cycle of spray tip was predicted by measuring the erosive wear tendency as increasing the spraying time of epoxy primer paint.

Immediate Effects of Maitland Transverse Movement on Pain, Trunk Flexion Movement and Cobb's Angle in Patient with Upper Thoracic Scoliosis

  • Moon, Ok Kon;Choi, Wan Suk;Kim, Nyeon Jun
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.7 no.2
    • /
    • pp.1066-1070
    • /
    • 2016
  • The purpose of this article was to investigate the effects of Maitland's transverse movement on change of pain, trunk flexion movement and Cobb's angle in patient with upper thoracic scoliosis. The subject are 37 years old with chronic low back pain participated in this study and has no experience surgery within the last six months due to back pain. 10 set was applied 10 times on the T3-T5 applied the transverse movement with grade IV to each segment by skilled physical therapist. Transverse movement was applied convex toward the concave side. Pressure pain threshold was reduced from 4/10 to 2/10. Trunk flexion range that is the distance between the middle finger and floor was increase from 7.3cm to 2cm. Cobb's angle was decreased from degree 18 to 16. This result demonstrated that the Maitland's transverse movement was benefit to reduce the pain and Cobb's angle, and to increase the trunk flexion movement.

Development of Anthropomorphic Robot Hand with Tactile Sensor: SKKU Hand II (촉각센서를 갖는 인간형 로봇손의 개발: SKKU Hand II)

  • Choi Byung-June;Lee Sang-Hun;Kang Sung-Chul;Choi Hyouk-Ryeol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.6
    • /
    • pp.594-599
    • /
    • 2006
  • In this paper an anthropomorphic robot hand called SKKU Hand IIl is presented, which has a miniaturized fingertip tactile sensor. The thumb is designed as one part of the palm and multiplies the mobility of the palm. The fingertip tactile sensor, based on polyvinylidene fluoride (PVDF) and pressure variable resistor ink, is physically flexible enough to be deformed into any three-dimensional geometry. In order to detect incipient slip, a PVDF strip is arranged along the direction normal to the surface of the finger of the robot hand. Also, a thin flexible sensor to sense the static force as well as the contact location is fabricated into an arrayed type using pressure variable resistor ink. The driving circuits and the tactile sensing systems for the SKKU Hand II are embedded in the hand. Each driving circuit communicates with others using CAN protocol. SKKU Hand II is manufactured and its feasibility is validated through preliminary experiments.

Evaluation of the Effect of Sedimentation Basin Structure on Hydrodynamic Behavior Using CFD (II): The Effect of Trough (CFD를 이용한 침전지 구조가 수리거동에 미치는 영향 평가(II): 트라프의 영향 중심으로)

  • Park, No-Suk;Lim, Jae-Lim;Lee, Sun-Ju;Kwon, Soon-Bum;Min, Jin-Hui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.758-766
    • /
    • 2005
  • This study was conducted to evaluate the effect of the transverse troughs on hydrodynamic behavior within the a certain full-scale sedimentation basin (flow rate/one basin; $10,000m^3/d$) using CFD simulation and ADV technique. In order to verify the CFD simulation, we measured the factual velocity at 36 points in the full-scale sedimentation basin, whose outlet structure is inadequate, with ADV technique. Both the CFD simulation and the ADV measurement results were in good accordance with each other. From the CFD simulation results of the existing basin, it was investigated that extreme upward flow occurs in the near of two transverse troughs. It was suspected that since the transverse troughs converted the open channel flow into the local closed pipe flow, the increased pressure in this local closed pipe flow region made the extreme upward flow. For solving this problems, it was suggested to modify transverse-typed launder into finger-typed launder and to install a longitudinal baffle in the center in this study. The CFD simulation results of all suggested amendments told us that the extreme upward flow, had occurred especially in the beneath of transverse troughs, was much less in the case of finger typed launder basin than that in the existing basin. Also, it was predicted that installing a longitudinal baffle made the fully developed flow which is more effective for sedimentation.