• Title/Summary/Keyword: Finger Pressure

Search Result 138, Processing Time 0.026 seconds

FEM Analysis of Caliper Housing Cut Inside Upper Face for Unbalance Wear Prevention of Disk Brake Pad (디스크 브레이크의 편마모 방지를 위한 finger 안쪽면 윗 부분이 가공된 캘리퍼 하우징의 유한 요소 해석)

  • Kim, Nam-Kyung;Kang, Jong-Pyo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.1 no.1
    • /
    • pp.89-100
    • /
    • 2002
  • The purpose if this research was to improve the pressure distribution on the disk brake pad Not uniform pressure distribution on the disk brake pad generate the unbalance wear of it and the unbalance wear of disk brake pad generate vibration, noise, heat and reduce the braking capacity. For improve the pressure distribution on the pad in this research, upper face of caliper housing finger was cut. Two kinds of caliper which uncut and cut of finger face were compared the stress distribution by FEM analysis and real experiment. Also natural frequency and deforming displacement ware calculated. It was understood that pressure distribution could Improve by cut inside upper face of caliper housing finger.

  • PDF

A Comparative Analysis of the Finger Pressure and Kinematic Variables in the Forehand Hairpin Net Shot According to Proficiency (배드민턴 포핸드 헤어핀 동작 시 숙련 정도에 따른 손가락 압력 및 운동학적 변인 비교 분석)

  • Lee, Haeng-Seob;Chae, Woen-Sik;Jung, Jea-Hu
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.4
    • /
    • pp.387-394
    • /
    • 2012
  • The purpose of this study was to compare and analyze the finger pressure and kinematic variables in the forehand hairpin net shot between skilled elite players and less skilled recreational players. Eight elite players(age: $18.1{\pm}0.8yrs$, height: $176.8{\pm}1.5cm$, weight: $640.9{\pm}48.6N$) with minimum of 6 years of experience and eight recreational players(age: $27.9{\pm}1.6yrs$, height: $177.1{\pm}6.1cm$, weight: $820.5{\pm}62.8N$) with less than one year experience were recruited in this study. For each trial being analyzed, four critical instants were identified from the video recordings: Right heel contact1 (E1), Right toe-off (E2), Right heel contact2 (E3), and Shuttlecock Impact (E4). Each hairpin net shot was broken into consecutive phases: E1~E2 (Right Landing Phase: RLP), E2~E3 (Sliding Step Phase: SSP), and E3~E4 (Impact Phase: IP). Temporal parameters, shuttlecock speed, linear and angular kinematics of body segments, and finger pressures were computed for this study. The results showed that The finger pressure of the ring finger and the middle finger for the skilled group during an impact had significantly greater than those of unskilled group. It is possible that all fingers were not used in the same manner when the racket was gripped in forehand hairpin. The result also suggested that the ring finger and the middle finger pushed the racket from top to bottom while having the mid-phalanx and proximal phalanx of index finger as an axis.

Electrodermal Activity at the Left Palm and Finger in Accordance with the Pressure Stimuli Applied to the Left Scapula

  • Kim, Jae Hyung;Kim, Su Sung;Son, Jung Man;Kim, Yung Jae;Baik, Sung Wan;Jeon, Gye Rok
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.235-242
    • /
    • 2016
  • A system for measuring the electrodermal activity (EDA) signal occurring at the sweat glands in the left palm and left finger of the human body was implemented in this study. The EDA measurement system (EDAMS) consisted of an algometer, a biopotential measurement system (BPMS), and a PC. Two experiments were performed to evaluate the function and clinical applicability of EDAMS. First, an experiment was carried out on the linearity of the voltage and the pressure that comprised the output signals of the algometer used for applying a pressure stimulus. Second, the amplitude of the EDA signal acquired from the electrode attached to the left palm or finger was measured while increasing the pressure stimulus of the algometer. When the pressure stimulus of the algometer applied to the left scapula was increased, the amplitude of the EDA signal increased. The amplitude of the EDA signal at the left palm was observed to be greater than that at the left finger. The amplitude of the EDA signal was observed to increase in a relatively linear relation with the intensity of the pressure stimuli. In addition, the latency of the EDA signal acquired from the electrode attached to the left palm or finger was measured while increasing the pressure stimulus of the algometer. When the pressure stimulus of the algometer applied to the left scapula was increased, the latency of the EDA signal decreased. The latency of the EDA signal at the palm was observed to be less than that at the finger. The latency of the EDA signal was observed to decrease nonlinearly with the pressure stimuli.

A Deformation Model of a Bag-Finger Skirt and the Motion Response of an ACV in Waves

  • Lee, Gyeong-Joong;Rhee, Key-Pyo
    • Selected Papers of The Society of Naval Architects of Korea
    • /
    • v.2 no.1
    • /
    • pp.29-46
    • /
    • 1994
  • In this paper, the effect of a skirt deformation on the responses of an Air Cushion Vehicle in waves is investigated. The air in the bag and plenum chamber is assumed to be compressible and to have a uniform pressure distribution in each volume. The free surface deformation is determined in the framework of a linear potential theory by replacing the cushion pressure with the pressure patch which is oscillating and translating uniformly. And the bag-finger skirt assumed to be deformed due to the pressure disturbance while its surface area remained constant. The restoring force and moment due to the deformation of bag-finger skirt from equilibrium shape is incorporated with the equations of heave and pitch motions. The numerical results of motion responses due to various ratios of the bag and cushion pressure or bag-to-finger depth ratios are shown.

  • PDF

Studies on Early Pregnancy Diagnosis in Dairy Cows (유우(乳牛)의 조기임신진단(早期姙娠診斷)에 관한 연구(硏究))

  • Kim, Kyo-Joon;Kim, Sang-Keun
    • Korean Journal of Veterinary Research
    • /
    • v.20 no.2
    • /
    • pp.135-141
    • /
    • 1980
  • This experiment was carried out to investigate of the early pregnancy diagnosis by finger pressure method, mucus smear method and rectal palpation method in 169 heads of pregnant dairy cow. 1. Pregnancy diagnostic rate of previous, middle and late period of pregnancy by finger pressure methods were 87.3%, 82.0% and 70% respectively. 2. Pregnancy diagnostic rate of previous, middle and late period of pregnancy by mucus smear methods were 83.1%. 94.9% and 95.0% respectively. 3. Pregnancy diagnostic rate of previous, middle and later period of pregnancy by rectal palpation methods were 83.1%, 96.1% and 100% respectively. 4. Pregnancy diagnostic rate of early pregnancy by finger pressure method, mucus smear method and rectal palpation method were 86.7%, 86.8% and 66% respectively. 5. Accordingly, finger pressure method in pregnancy diagnosis is thought to be recommendable because this early diagnostic means are simple with accurate results.

  • PDF

The Effect of Hand and Finger Exercise on Grip Strength and Pinch Pressure in Elderly Women (손과 손가락 근관절운동이 노년기 여성의 악력과 잡기력에 미치는 영향)

  • Kim, Jong-Im;Kim, Hyun-Li;Kim, Sun-Ae
    • Journal of muscle and joint health
    • /
    • v.9 no.1
    • /
    • pp.18-27
    • /
    • 2002
  • Introduction : Exercise has been suggested as an important nursing strategy in which to help elderly maintain functional performance and to enhanced quality of life. Most of exercise study has been reported on fitness exercise such as walking, swimming, dance etc for health of elderly. There have been few reports about exercise on the promotion of small and fine movement of elderly. The purpose of this pilot study was to determine an effect of 6 weeks hand and finger exercise in home to improve hand muscle strength such as grip strength and finger pinch pressure. Materials and Methods Design: This pilot study was used one group pre and post-test design. Sample: Twelve elderly women above 60 years of age or older living in community were selected by convenient sampling. Procedure: Signed informed consent was obtained prior to participate in this study. The authors met elderly and taught hand and finger exercise, daily a week for 6 weeks, within 30 minutes per session. But exercise frequency and strength were not same. Instruments: Left and right grip strength were measured by Bulb Dynamometer(made in USA) and left and right pinch pressure were measured by Baseline Hydraulic Pinch Gauge(made in USA). Data analysis: Discriptive data analyses were performed on all variables. Wilcoxon matched-pairs Signed-Ranks test were used to find difference of grip strength and pinch pressure between pre and post exercise using SPSS 10.0 for Window. Results: Samples age ranged from 60 to 73, Mean age was 65.3. All were women. Ten elderly were diagnosed osteoarthritis and one had DM. After six weeks hand and finger exercise, Left and right grip strength were higher than those of before exercise(Z=-2.667, P<0.01 ; Z=-3.065, p<0.01). And left pinch pressure after hand and linger exercise were higher than that of before pinch pressure (Z=-2.315, p<0.05). But Right pinch pressure was not shown significant change(Z=-1.099, p>0.05). Conclusions: Although this study was limited by the sample size and design, the findings provide some important implications for community based exercise nursing intervention. Short term (six weeks) exercise of hand and linger is shown to be useful as nursing intervention to maintain routine daily activities such as eating, writing, grip something for elderly.

  • PDF

High-Pressure Finger Injection Injury Caused by Paint Thinner: Case Report (페인트 신나에 의한 수지 고압 손상의 경험)

  • Song, Jin Woo;Choi, Hwan Jun;Kim, Mi Sun
    • Archives of Plastic Surgery
    • /
    • v.34 no.2
    • /
    • pp.269-273
    • /
    • 2007
  • Purpose: High-pressure injection(HPI) injury is an injury caused by accidental injection of substances by industrial equipment. HPI injury of the hand is a serious injury that can be potentially devastating. There have been a number of publications on the results of its treatment and its functional outcome of these hands. Unfortunately, the clinical outcomes were unsatisfactory following an initial treatment approach of digital expression of the injection material, elevation, soaks, dressing changes, and antibiotics. Methods: A 43-year-old right handed man sustained a high pressure injection injury to the tip of the left index finger. The injected material was industrial paint thinner. Tissue necrosis was noted at the pulp of the finger. Several debridements and irrigation were required. A pedicled chest flap transfer was performed on the eighteenth day after injury as the dorsal nail complex remained viable. This is a retrospective review of our experience with high-pressure finger injection injury caused by paint. A literature review, retrospective chart and radiologic review were presented. Results: Follow-up length was about 1 year. The injuried hand was left nondominant hand, the index. Patient complaints were cold intolerance, paresthesia, contact pain, and impairment of activities of daily living. Conclusion: The outcome of high-pressure injection injuries of the hand is affected by many factors. The time between injury and operative treatment has been regarded as a key determinant by a number of authors. The nature of the injected material is probably more important. It has been noted by many authors that injuries with paints have a worse outcome than those with oil or grease. This study confirms the fact that high-pressure injection injury caused by paint thinner to the hand is a significant problem. Virtually a patient suffers sequelae of this injury. The injury has significant repercussions for future function and reintegration into the work force.

Study on Ovum Pick-up(OPU) with Finger-Sensibility using Oocyte Recovery in Holstein Heifers (젖소에서 초음파기기를 이용한 난자 채취에 있어서 손가락 촉지를 이용한 난포란의 채란)

  • 진종인;홍승표;정장용;이지삼;박희성
    • Journal of Embryo Transfer
    • /
    • v.15 no.3
    • /
    • pp.279-286
    • /
    • 2000
  • This study was conducted to develop an improved method for oocyte pick-up(OPU) with finger-sensibility using ultrasound-guidance from ovarian follicles in Holstein heifers. Oocytes were aspirated from ovarian follicles of clear-outline (>2mm), obscure-outline and invisible($\leq$ 2mm) on ultrasound images with 3 different vacuum pressure(40, 80, 120mmHg). Total number of oocytes recovered/follicles were 309/237(130.4%). 113/80(141.3%) and 107/74(144.6%) with 40, 80 and 120 mmHg of vacuum pressure, respectively. Mean number of oocytes recovered was higher in 2 OPU/week (18.3$\pm$5.3) than 1 OPU/week(14.5$\pm$4.1), but this difference was not statistical1y significant. The recovery rates were not affected by the number of OPU as 135.6%(282 oocytes/208 follicles) in 1~20 OPU, 137.7% (168/122) in 21~40 OPU and 148.4%(92/62) in 41~60 OPU, respectively. The proportions of good oocytes (Grades I) recovered were not significantly different by the number of OPU until 40 OPU(12.4% in 1~20 OPU vs 16.7% in 21~40 OPU). However, a significantly(P<0.05) lower recovery rate resulted from more than 40 OPU compared to less than 40 OPU(7.6%). These results imply that more fertilizable oocytes can be produced from invisible-immature follicles by transvaginal aspiration with finger-sensibility from Holstein heifers.

  • PDF

Smart Wrist Band Considering Wrist Skin Curvature Variation for Real-Time Hand Gesture Recognition (실시간 손 제스처 인식을 위하여 손목 피부 표면의 높낮이 변화를 고려한 스마트 손목 밴드)

  • Yun Kang;Joono Cheong
    • The Journal of Korea Robotics Society
    • /
    • v.18 no.1
    • /
    • pp.18-28
    • /
    • 2023
  • This study introduces a smart wrist band system with pressure measurements using wrist skin curvature variation due to finger motion. It is easy to wear and take off without pre-adaptation or surgery to use. By analyzing the depth variation of wrist skin curvature during each finger motion, we elaborated the most suitable location of each Force Sensitive Resistor (FSR) to be attached in the wristband with anatomical consideration. A 3D depth camera was used to investigate distinctive wrist locations, responsible for the anatomically de-coupled thumb, index, and middle finger, where the variations of wrist skin curvature appear independently. Then sensors within the wristband were attached correspondingly to measure the pressure change of those points and eventually the finger motion. The smart wrist band was validated for its practicality through two demonstrative applications, i.e., one for a real-time control of prosthetic robot hands and the other for natural human-computer interfacing. And hopefully other futuristic human-related applications would be benefited from the proposed smart wrist band system.

Which is the proper insertion method of laryngeal mask airway according to the rescuer's position? : Comparison between index finger insertion and thumb insertion (구조자의 위치에 따른 적절한 후두마스크기도기 삽입방법은 무엇일까? : 검지손가락법과 엄지손가락법의 비교)

  • Chun, Kyoung-Ha;Moon, Jun-Dong
    • The Korean Journal of Emergency Medical Services
    • /
    • v.21 no.3
    • /
    • pp.7-16
    • /
    • 2017
  • Purpose: The purpose of the study was to investigate the effects of laryngeal mask airway (LMA) insertion from different positions, using different methods, on the quality of the insertion, for identifying a more convenient and effective insertion method. Methods: In a model ambulance, 30 paramedic students performed the LMA insertion procedure, in four different settings, combinations of the rescuer's position (at the head end of the patient, at the side of the patient), and insertion technique (index finger insertion, thumb insertion), in a randomized order. Quality of insertion index and convenience of use were measured. Results: The quality of insertion index (tidal volume, gastric insufflation, airway pressure, airway sealing pressure, midline positions, insertion success grade, and insertion time) were not significantly different among four different settings. However LMA insertion from the anterior (head) end, using the index finger method compared to the thumb method was found to be significantly more convenient. Conclusion: We recommend using the more convenient and familiar LMA insertion method, between index finger insertion and thumb insertion, regardless of rescuer's position.