• 제목/요약/키워드: Fine Particulate Matter

검색결과 282건 처리시간 0.021초

화력발전소의 미세먼지 배출특성 (Emission Characteristics of Fine Particles from Thermal Power Plants)

  • Park, Sooman;Lee, Gayoung
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권4호
    • /
    • pp.455-460
    • /
    • 2020
  • In order to identify the characteristics of fine particle emissions from thermal power plants, this study conducted measurement of the primary emission concentration of TPM, PM10 and PM2.5 according to Korea standard test method (ES 01301.1) and ISO 23210 method (KS I ISO 23210). Particulate matters were sampled in total 74 units of power plants such as 59 units of coal-fired power plants, 7 units of heavy oil power plants, 2 units of biomass power plant, and 6 units of liquid natural gas power plants. The average concentration of TPM, PM10, PM2.5 by fuel are 3.33 mg/m3, 3.01 mg/m3, 2.70 mg/m3 in coal-fired plant, 3.02 mg/m3, 2.99 mg/m3, 2.93 mg/m3 in heavy oil plant, 0.114 mg/m3, 0.046 mg/m3, 0.036 mg/m3 in LNG plant, respectively. These results of TPM, PM10 and PM2.5 were satisfied with the standards of fine dust emission allowance in all units of power plants, respectively. Also, this study evaluated the characteristics of fine particle emissions by conditions of power plants including generation sources, boiler types and operation years and calculated emission factors and then evaluated fine particle emissions by sources of electricity generation.

Analysis of Chemical Compounds of Gaseous and Particulate Pollutants from the Open Burning of Agricultural HDPE Film Waste

  • Kim, Tae-Han;Choi, Boo-Hun;Kook, Joongjin
    • 인간식물환경학회지
    • /
    • 제24권6호
    • /
    • pp.585-593
    • /
    • 2021
  • Background and objective: Illegal open-air incineration, which is criticized as a leading source of air pollutants among agricultural activities, currently requires constant effort and attention. Countries around the world have been undertaking studies on the emission of heavy metal substances in fine dust discharged during the incineration process. A precise analytical method is required to examine the harmful effects of particulate pollutants on the human body. Methods: In order to simulate open-air incineration, the infrastructure needed for incineration tests complying with the United States Environmental Protection Agency (EPA) Method 5G was built, and a large-area analysis was conducted on particulate pollutants through automated scanning electron microscopy (SEM)-energy-dispersive X-ray spectroscopy (EDS). For the test specimen, high-density polyethylene (HDPE) waste collected by the DangJin Office located in Choongcheongnam-do was used. To increase the identifiability of the analyzed particles, the incineration experiment was conducted in an incinerator three times after dividing the film waste into 200 g specimens. Results: Among the metal particulate matters detected in the HDPE waste incineration test, transition metals included C (20.8-37.1 wt%) and O (33.7-37.9 wt%). As for other chemical matters, the analysis showed that metal particulate matters such as metalloids, alkali metals, alkaline earth metals, and transition metals reacted to C and C-O. Si, a representative metalloid, was detected at 14.8-20.8 wt%, showing the highest weight ratio except for C and O. Conclusion: In this study, the detection of metal chemicals in incinerated particulate matters was effectively confirmed through SEM-EDS. The results of this study verified that HDPE waste adsorbs metal chemicals originating from soil due to its own properties and deterioration, and that when incinerated, it emits particulate matters containing transition metals and other metals that contribute to the excessive production and reduction of reactive oxygen species.

수도권 미세먼지 환경 개선을 위한 미국의 대기환경정책 사례 조사 연구 (Review of PM-related Air Quality Improvement Policies of United States for PM-related Air Quality Improvement of Metropolitan Region in Korea)

  • 우정헌
    • 한국대기환경학회지
    • /
    • 제25권6호
    • /
    • pp.579-593
    • /
    • 2009
  • Several fine particle-related policies in Northeast United States were investigated in support of the execution of special measures to improve air quality of Seoul Metropolitan Area (SMA). The definition of particulate matter (PM) in the Clean Air Act (CAA), components and procedures of Regional Haze Rule (RHR), and Air Quality Management (AQM) were reviewed. Several State Implementation Plans (SIPs) were also reviewed as the way to attain required air quality under the Clean Air Act. $PM_{2.5}$ attainment SIP of Maryland, 8-hr Ozone attainment SIP of New Jersey, and Regional Haze Rule attainment SIP of MANE-VU were analyzed in detail as case studies. We realized that "Special Measures for Air Quality Improvement in the Seoul Metropolitan Area" has many similarities with its US counterparts in terms of purpose, components, procedures, and implementation methods. US policies, however, have more advanced features, such as standardized procedures and methods, transparent guidelines, and stable relationship among federal/state/local governments and stakeholders, which would be helpful to improve air quality in SMA.

Size Distribution and Source Identification of Airborne Particulate Matter and Metallic Elements in a Typical Industrial City

  • Ny, Mai Tra;Lee, Byeong-Kyu
    • Asian Journal of Atmospheric Environment
    • /
    • 제4권1호
    • /
    • pp.9-19
    • /
    • 2010
  • The size distribution of airborne particulate matter (PM) and the concentrations of associated metallic elements were investigated in a busy urban region of a typical Korean industrial city. The PM concentrations measured during the spring, except for those in the size range of 1.1 to 2.1 ${\mu}m$, were slightly higher than the PM concentrations in the summer. Coarse particles contributed greatly to the variation in PM concentrations in the spring, while fine and submicron particles contributed largely to the variation in PM concentrations in the summer. The difference in size modes of the PM concentrations between spring and summer may be explained by the Asian dust effect and its accompanying wind direction and speed. Extremely high enrichment factors (EFs) values (6,971 to 60,966) for all of the size distributions in PM were identified for cadmium (Cd). High EFs values (12 to 907) were also identified for other heavy metals including Cr, Cu, Ni, Pb, Zn and Mn. Low EF values (0.29 to 8.61) were identified for Ca, K, Mg and Na. These results support the common hypothesis that most heavy metals in ambient PM have anthropogenic sources and most light metals have crustal sources. The results of principal components analyses and cluster analyses for heavy metals indicate that the principal sources of PM and metals were emissions from non-ferrous metal smelters, oil combustion, incinerators, vehicular traffic and road dust.

Exposure to Fine Particle along Different Commuting Routes in Urban Area of Fukuoka, Japan

  • Ma, Chang-Jin
    • Asian Journal of Atmospheric Environment
    • /
    • 제9권3호
    • /
    • pp.205-213
    • /
    • 2015
  • The objective of the current study was to assess the comparative risk associated with exposure to particulate matter (PM) while commuting via different public transport modes in Fukuoka, Japan. For the given routes and measuring days, a trip-maker carried a lightweight portable bag loaded the real-time measurement devices which take simultaneous measurement for size-fractioned particle number concentration, $PM_{2.5}$ mass concentration, and total suspended particle (TSP) collection. The results of the present study have shown significant differences between public transports as commuting modes in Fukuoka. The PM exposure levels on subway platform and inside subway train were overwhelmingly higher than those of other points on commuting route. The relative ratio between modes (i.e., the ratio of $PM_{2.5}$ inside subway to that inside bus) provides an idea for choosing a right commuting mode for our health. This study clearly provided evidence of the extremely high levels of iron exposure by subway uses compared to bus uses. The result of theoretically reconstructed mass concentration of $PM_{2.0-0.3}$ collected on subway platform suggests that the PM of underground subway will be associated with PM both generated in subway system and inleakaged from outdoor environment.

Young Adult Street Vendors and Adverse Respiratory Health Outcomes in Bangkok, Thailand

  • Noomnual, Saisattha;Shendell, Derek G.
    • Safety and Health at Work
    • /
    • 제8권4호
    • /
    • pp.407-409
    • /
    • 2017
  • Air pollutants of concern include traffic-related air pollution, including particulate matter in respirable coarse and fine size fractions. There are no critical studies to date into associations between knowledge, awareness, and attitudes in using proper respiratory masks and prevalence of respiratory symptoms among urban street vendors in Thailand. In this study, we estimated adverse respiratory health outcomes among street vendors, in particular young adults, in Bangkok, Thailand, using a self-report questionnaire. Street vendors, who were not currently smoking and not having known diagnosed respiratory diseases, were recruited. They were selected from selected roadsides at Chong Nonsi, Bangkok. Participants (n = 30) reported having lower respiratory (50%), upper respiratory (37%), and other symptoms (70%). Also, 53% of participants had never used respiratory personal protective equipment (PPE: masks). Among those using PPE, all used masks not proper for particulate matter. Results suggested knowledge, awareness, and attitudes concerning proper PPE use needs to be increased among street vendors in Bangkok, Thailand.

Efficiency of Removal of Indoor Pollutants by Pistia stratiotes, Eichhornia crassipes and Hydrocotyle umbellata

  • Park, Hye-Min;Lee, Ae-Kyung
    • 인간식물환경학회지
    • /
    • 제23권1호
    • /
    • pp.15-21
    • /
    • 2020
  • In this study, we compared efficiency of different aquatic plants in removing indoor pollutants and examined their potential to purify indoor air. Two liter of water in chamber was used as the control, while the other chambers containing water lettuce (Pistia stratiotes), water hyacinth (Eichhornia crassipes), and water coin (Hydrocotyle umbellata) were used as treatment groups. Temperatures inside all the chambers were maintained between 20 ℃ and 23 ℃. Humidity in the chambers with aquatic plants increased by 30% and 50% control respectively. The removal of formaldehyde per unit leaf area was examined in each aquatic plant. It turned out that water hyacinth removed the highest amount of formaldehyde, followed by water lettuce and water coin. Both water hyacinth and water lettuce increased the amount of removal of formaldehyde until the end of the experiment. In the case of airborne dust (PM 10) and fine dust (PM 2.5), water coin, which had the highest number of leaves, removed more PM 10 and PM 2.5 than the other aquatic plants, with statistically significant difference. In addition, both water coin and water hyacinth smoothly opened and closed stomata before and after the experiment. Consequently, as the aquatic plants were effective in controlling humidity and removing pollutants, they can be used as air purifying plants.

大氣浮遊粉塵中 多環芳香族炭火水素 및 重金屬의 濃度 (Atmospheric Concentration of Polycyclic Aromatic Hydrocarbons and Heavy Metals in Suspended Particulate)

  • 손동헌;권창호;정원태;허문영
    • 한국대기환경학회지
    • /
    • 제7권1호
    • /
    • pp.17-22
    • /
    • 1991
  • Total suspended particulates (TSP) in the atmosphere was collected and size-fractionated by Andersen high volume air sampler for one year (Mar. 1987 $\sim$ Feb. 1988) in Seoul. The concentrations of several polycyclic aromatic hydrocarbons and heavy metals were determined to investigate the atmospheric concentrations, seasonal variations and its relationship with the size distribution of suspended particulate matter. The arithmetic mean concentration of total suspended particulates was 200.44 $\mug/m^3$. The concentrations of heavy metals were 2433.80 for Fe, 629.49 for Zn, 600.71 for Pb, 143.87 for Cu, and 107.21 $ng/m^3$ for Mn, respectively. The concentrations of PAHs were 3.83 for benzo(a) pyrene, 2.95 for benzo(k)fluoranthene, and 4.42 $ng/m^3$ for benzo(ghi)perylene, respectively. PAHs, Pb and Zn abounded in particles below 2.0 $\mu$m, while Fe and Mn aboounded in particles above 2.0 $\mu$m. TSP and its chemical compositions showed the seasonal variations. The concentrations of anthrophogenic pollutants like TSP, PAHs and heavy metals in the fine particles were highest in winter and lowest in summer. PAHs and Pb analyzed showed significant correlations between each other and between TSP concentration in fine particles, indicating that the particles in which they are contained have a similar behavior in the atmosphere.

  • PDF

일부 서울지역 미세먼지의 화학적 조성에 관한 연구 (Comparison of Chemical Characteristics of Fine Particulate in Seoul Area)

  • 이홍석;김윤신;박태술;이종태;조용성;이상복
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2001년도 추계학술대회 논문집
    • /
    • pp.231-232
    • /
    • 2001
  • 도시지역의 주 오염물질 중 하나인 입자상 물질(Particulate Matter:PM)은 공기역학적 직경 2.5$\mu\textrm{m}$을 기준으로 이산형 분포를 하여 2.5$\mu\textrm{m}$이하를 미세입자, 2.5$\mu\textrm{m}$이상을 조대입자로 나뉜다. 이 미세입자는 주로 자동차 배출, 산업연소에서 배출되는 가스상 물질의 2차 반응으로 발생한다(Pope et al., 1995). 미세입자는 상당량이 2차 반응에서 생성되는 물질이며, 크기가 작은 대신 상대적으로 표면적이 크기 때문에 각종 중금속과 유해 대기오염물질과의 흡착이 용이하여 호흡기 계통의 질병을 일으킬 수 있는 확률이 조대입자에 비해 높다고 알려져 있어 인체에 미치는 영향이 클 것으로 시사되고 있다(Dockery et al., 1998). (중략)

  • PDF

간척지, 해안가 근처의 농업용수 공급을 위한 기수담수 시스템 연구

  • 홍민
    • 한국농공학회지
    • /
    • 제57권4호
    • /
    • pp.16-24
    • /
    • 2015
  • Desalination technology is a process to remove salt from water. There are three classified In accordance with the concentration of salt The concentration of sea water 15,000~50,000mg/l, brackish water 1,500~15,000mg/l, desalination less than 500mg/l.. In general, salt to remove for using a pre-treatment UF filter, but this study is new pre-treatment technology RO Membrane process technology Suspended particulate matter is said most were treated at the pre-treatment equipment, wheat affluent particulate material was removed from the MF filter. Influent SS 16.2mg /l The treatment was effective in treatment 0.05mg /l of 99% is removed. COD is reduced to 60% in the pre-treatment device, after treatment was reduced to 30% RO membrane. Influent COD 10.2mg/l treatment was removed 1.9mg/l. The removal rate is 81.9%. Desalination removes the ionic substances in the RO Membrane. Influent EC $978.8{\mu}s/cm$ and treatment showed a result of $18.7{\mu}s/cm$.