• Title/Summary/Keyword: Fine Needle Aspiration

Search Result 697, Processing Time 0.02 seconds

Touch Imprint and Fine Needle Aspiration Cytology of Giant Cell Tumor of Tendon Sheath - A Case Report - (건초거대세포종의 압착도말 및 세포흡인 세포소견 - 1예 보고 -)

  • Lee, Jong-Im
    • The Korean Journal of Cytopathology
    • /
    • v.19 no.1
    • /
    • pp.57-64
    • /
    • 2008
  • Giant cell tumor of the tendon sheath (GCTTS) is a slowly growing, benign soft tissue tumor. The tumors occur predominantly on the hands and feet. Although the clinical and histopathologic features are well-defined, only a few reports have described the cytologic appearance of this entity. A 26-year-old woman presented with a gradually developing circumscribed soft tissue mass near the proximal phalanx of her left little finger for one year. Imprint and fine needle aspiration (FNA) smears were obtained from the excisional biopsy specimen. The imprint smears were composed of predominantly singly dispersed bland mononuclear cells and several giant cells. The mononuclear cells were polygonal to round, and they showed a histiocyte-like appearance. Osteoclast-type multinucleated giant cells of various sizes were randomly scattered throughout the smears, and these cells contained 3 to 50 nuclei. Nuclear atypia and pleomorphism were absent in both the single and giant cells. Loose aggregates of hemosiderin-laden macrophages and binuclear stromal cells were also seen. The cytologic features of the FNA smears were similar with those of the imprint, Additionally, the FNA smears contained several clumps of densely collagenous stromal tissue that were seldom noted in previously reported cytologic material. The cytologic features were well-correlated with the concurrent histologic findings and the diagnosis of GCTTS was made. When the clinical and radiologic datas are integrated, the diagnosis of GCTTS can be strongly suggested, based on the pre-operative cytologic specimen.

Analysis of Fine Needle Aspiration Cytology and Ultrasonography of Metastatic Tumors to the Thyroid (갑상샘 전이종양에 대한 세침흡인 세포 소견과 초음파 소견의 분석)

  • Cho, Eun-Yoon;Oh, Young-Lyun
    • The Korean Journal of Cytopathology
    • /
    • v.18 no.2
    • /
    • pp.133-142
    • /
    • 2007
  • Cytologic diagnosis of the metastatic tumors to the thyroid is important in the management of the patients. There have been rare reports analyzing fine-needle aspiration (FNA) cytology of metastatic tumors to the thyroid. This study examines comprehensive cytologic findings of metastatic tumors to the thyroid with radiologic findings. The FNA cytology slides obtained from 12 cases with metastatic tumors of the thyroid; lung cancer (n=5), tongue and tonsil cancer (n=3), esophageal cancer (n=2), and breast cancer (n=2) were reviewed. Radiological study showed single mass with heterogeneous texture or multiple masses without calcification. Metastatic tumor was easily considered in a differential diagnosis of FNA cytology because they had peculiar cytological features which were not seen in primary thyroid tumor. The smear background varied from predominantly necrotic, bloody, and inflammatory to colloid. The aspirates exhibited a mixture of benign follicular cells and malignant cells in 6 cases. The characteristic cytoplasmic features of the tumor cells, such as keratin, mucin and melanin, were found in 9 cases. Although some cases mimic primary thyroid neoplasm, a careful examination of the cytological characteristics may help cytopathologists to recognize a metastatic tumor in the thyroid by FNA, and may help the clinicians to establish a proper treatment plan.

Fine Needle Aspiration Cytology of Metastatic Prostatic Adenocarcinoma, Pseudohyperplastic Variant (전이된 가성증식성 전립선 샘암종의 세침흡인 세포소견 -1예 보고-)

  • Kwon, Young-Mee;Park, Won-Seo;Lee, Geon-Kook;Hong, Eun-Kyung
    • The Korean Journal of Cytopathology
    • /
    • v.19 no.2
    • /
    • pp.183-187
    • /
    • 2008
  • Pseudohyperplastic prostatic adenocarcinoma is a rare histologic variant of prostatic adenocarcinoma that resembles benign nodular hyperplasia. Immunohistochemistry can verify the absence of basal cells, but it is frequently admixed with conventional adenocarcinoma. Because fine needle aspiration cytology is rarely performed in primary prostatic adenocarcinoma, the cytology of the pseudohyperplastic variant has not been described. We experienced a case of metastatic pseudohyperplastic adenocarcinoma in a pulmonary nodule of 75-year-old man. The cytologic smear was mostly composed of large, flat sheets with elongated branching papillae in a clean background. The sheets showed a well-defined honeycomb appearance of tall columnar, regularly arranged monotonous cells with little cytologic atypia. In subsequent prostatic biopsy, pseudohyperplastic variants were identified together with conventional adenocarcinoma of Gleason's grade 3 and 4. The cytologic features of pulmonary nodules were identical to those of pseudohyperplastic components of prostatic adenocarcinoma.

Study of Autoantibody Concentration Distribution by Thyroid Fine Needle Aspiration Biopsy (갑상선 조직 검사에 따른 자가 항체 농도 분포 연구)

  • Kim, Jean-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4320-4325
    • /
    • 2013
  • This study was investigated the correlation between thyroid fine needle aspiration biopsy and serological test's concentrations. I examined fifty patients who were diagnosed with thyroid cancer from June 2012 to December 2012 in Pathology of a certain university hospital. Healthy fifty people were selected as a control group. Thyroid function tests were used as variables. In conclusion, The thyroglobulin and autoantibody was showed positive correlations in cancer groups. also Thyroglobulin Ab was showed a little correlation. If we examine this study items, we will get help in early diagnosis.

Diagnostic Imaging for Solitary Nodular Form of Alimentary Lymphoma in a Dog (개 고립 결절 형태의 소화기계 림프종에 대한 진단영상 1례)

  • Choi, Ji-Hye;Kim, Hyun-Wook;Jang, Jae-Young;Kim, Hye-Jin;Kim, Jun-Young;Yoon, Jung-Hee
    • Journal of Veterinary Clinics
    • /
    • v.24 no.3
    • /
    • pp.467-472
    • /
    • 2007
  • Alimentary lymphoma accounts for approximately 5% of neoplasm and diffuse lesion is more common than solitary nodular form in dogs. An eleven year-old male Yorkshire terrier was examined because of nonspecific gastrointestinal symptoms such as anorexia and vomiting for 10 days. An abdominal mass was palpated, which was originated from small intestinal wall in abdominal ultrasonography. Small intestine was obstructed by hypoechoic mass and lost normal layering and measured 24.5m. After fine-needle aspiration, septic peritonitis due to intestinal rupture occurred and emergency surgery was performed. Solitary mass was found in small intestine and diagnosed as alimentary lymphoma through histopathologic examination. Conclusively, abdominal ultrasonouaphy could verify the thickened bowel, loss of wall layering and decrease of motility and percutaneous ultrasound-guided fine-needle aspiration is considered as useful diagnostic technique, especially in nodular form of alimentary lymphoma.

Role of Endoscopic Ultrasound-Guided Fine-Needle Aspiration in the Evaluation of Abdominal Lymphadenopathy of Unknown Etiology

  • Nonthalee Pausawasdi;Kotchakon Maipang;Tassanee Sriprayoon;Phunchai Charatcharoenwitthaya
    • Clinical Endoscopy
    • /
    • v.55 no.2
    • /
    • pp.279-286
    • /
    • 2022
  • Background/Aims: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is a standard procedure for obtaining tissue from lesions near the gastrointestinal lumen. However, there is a scarcity of information on the diagnostic performance of EUS-FNA for abdominal lymphadenopathy of unknown causes. To assess the accuracy of EUS-FNA in diagnosing abdominal lymphadenopathy of unknown etiology. Methods: The EUS records of patients with undiagnosed abdominal lymphadenopathy between 2010 and 2015 were reviewed. Results: A total of 42 patients were included in this study. Adequate specimens were obtained from 40 patients (95%). The final diagnoses were metastatic cancer (n=16), lymphoma (n=9), tuberculosis (n=8), inflammatory changes (n=6), and amyloidosis (n=1). For diagnosing malignancy, EUS-FNA had a sensitivity of 84.6%, specificity of 95.7%, positive predictive value of 91.7%, negative predictive value of 91.7%, and area under the receiver operating characteristic curve (AUROC) of 0.901. For the diagnosis of lymphoma, EUS-FNA was 100% accurate when combined with cytologic evaluation and immunohistochemical staining. The diagnostic sensitivity decreased to 75%, whereas the specificity remained 100%, for tuberculosis. The overall AUROC was 0.850. No procedure-related complications occurred. Conclusions: EUS-FNA showed high diagnostic performance for abdominal lymphadenopathy of unknown causes, especially malignancy, lymphoma, and tuberculosis. Therefore, it is a crucial diagnostic tool for this patient population.

A multicenter comparative study of endoscopic ultrasound-guided fine-needle biopsy using a Franseen needle versus conventional endoscopic ultrasound-guided fine-needle aspiration to evaluate microsatellite instability in patients with unresectable pancreatic cancer

  • Tadayuki Takagi;Mitsuru Sugimoto;Hidemichi Imamura;Yosuke Takahata;Yuki Nakajima;Rei Suzuki;Naoki Konno;Hiroyuki Asama;Yuki Sato;Hiroki Irie;Jun Nakamura;Mika Takasumi;Minami Hashimoto;Tsunetaka Kato;Ryoichiro Kobashi;Yuko Hashimoto;Goro Shibukawa;Shigeru Marubashi;Takuto Hikichi;Hiromasa Ohira
    • Clinical Endoscopy
    • /
    • v.56 no.1
    • /
    • pp.107-113
    • /
    • 2023
  • Background/Aims: Immune checkpoint blockade has recently been reported to be effective in treating microsatellite instability (MSI)-high tumors. Therefore, sufficient sampling of histological specimens is necessary in cases of unresectable pancreatic cancer (UR-PC). This multicenter study investigated the efficacy of endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) using a Franseen needle for MSI evaluation in patients with UR-PC. Methods: A total of 89 patients with UR-PC who underwent endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) or EUS-FNB using 22-G needles at three hospitals in Japan (2018-2021) were enrolled. Fifty-six of these patients (FNB 23 and FNA 33) were followed up or evaluated for MSI. Patient characteristics, UR-PC data, and procedural outcomes were compared between patients who underwent EUS-FNB and those who underwent EUS-FNA. Results: No significant difference in terms of sufficient tissue acquisition for histology was observed between patients who underwent EUS-FNB and those who underwent EUS-FNA. MSI evaluation was possible significantly more with tissue samples obtained using EUS-FNB than with tissue samples obtained using EUS-FNA (82.6% [19/23] vs. 45.5% [15/33], respectively; p<0.01). In the multivariate analysis, EUS-FNB was the only significant factor influencing the possibility of MSI evaluation. Conclusions: EUS-FNB using a Franseen needle is desirable for ensuring sufficient tissue acquisition for MSI evaluation.

Prospective Assessment of the Performance of a New Fine Needle Biopsy Device for EUS-Guided Sampling of Solid Lesions

  • El Hajj, Ihab I.;Wu, Howard;Reuss, Sarah;Randolph, Melissa;Harris, Akeem;Gromski, Mark A.;Al-Haddad, Mohammad
    • Clinical Endoscopy
    • /
    • v.51 no.6
    • /
    • pp.576-583
    • /
    • 2018
  • Background/Aims: Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) remains the most common EUS-guided tissue acquisition technique. This study aimed to evaluate the performance of a new Franseen tip fine needle biopsy (FNB) device for EUSguided sampling of solid lesions and compare it with the historical FNA technique. Methods: $Acquire^{(R)}$ 22 G FNB needle (Boston Scientific Co., Natick, MA, USA) was used for solid tumor sampling (Study group). Tissue was collected for rapid on-site evaluation, and touch and crush preparations were made. Historical EUS-FNA samples obtained using $Expect^{(R)}$ 22 G FNA needle (Boston Scientific Co.) were used as controls (Control group). All specimens were independently evaluated by two cytopathologists blinded to the formal cytopathological diagnosis. Results: Mean cell block histology scores were significantly higher (p=0.046) in the FNB group (51 samples) despite a significantly lower (p<0.001) mean number of passes compared to the FNA group (50 specimens). The overall diagnostic yields for the FNB vs. FNA groups were 96% vs. 88%. The degree of tumor differentiation was adequately assessed in all cell block qualifying lesions in the FNB group. Two patients developed post-FNB abdominal pain. Conclusions: The new Franseen tip FNB device provides histologically superior and cytologically comparable specimens to those obtained by FNA, but with fewer passes.

Diagnostic Accuracy of Fine Needle Aspiration Cytology versus Concurrent Core Needle Biopsy in Evaluation of Intrathoracic Lesions: a Retrospective Comparative Study

  • Eftekhar-Javadi, Arezoo;Kumar, Perikala Vijayananda;Mirzaie, Ali Zare;Radfar, Amir;Filip, Irina;Niyazi, Maximilian;Sadeghipour, Alireza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.16
    • /
    • pp.7385-7390
    • /
    • 2015
  • Background: Transthoracic fine needle aspiration (FNA) cytology and core needle biopsy (CNB) are two commonly used approaches for the diagnosis of suspected neoplastic intrathoracic lesions. This study compared the diagnostic accuracy of FNA cytology and concurrent CNB in the evaluation of intrathoracic lesions. Materials and Methods: We studied FNA cytology and concurrent CNB specimens of 127 patients retrospectively, using hematoxylin and eosin (H&E), immunohistochemistry, and, on certain occasions cytochemistry. Information regarding additional tissue tests was derived from the electronic archives of the Department of Pathology and Laboratory Medicine as well as patient records. Diagnostic accuracy was calculated for each test. Results: Of 127 cases, 22 were inconclusive and excluded from the study. The remaining 105 were categorized into 73 (69.5%) malignant lesions and 32 (30.5%) benign lesions. FNA and CNB findings were in complete agreement in 63 cases (60%). The accuracy and confidence intervals (CIs) of FNA and CNB for malignant tumors were 86.3% (CI: 79.3-90.7) and 93.2% (CI: 87.3-96.0) respectively. For epithelial malignant neoplasms, a definitive diagnosis was made in 44.8% of cases by FNA and 80.6% by CNB. The diagnostic accuracy of CNB for nonepithelial malignant neoplasms was 83.3% compared with 50% for FNA. Of the 32 benign cases, we made specific diagnoses in 16 with diagnostic accuracy of 81.3% and 6.3% for CNB and FNA, respectively. Conclusions: Our findings suggest that FNA is comparable to CNB in the diagnosis of malignant epithelial lesions whereas diagnostic accuracy of CNB for nonepithlial malignant neoplasms is superior to that for FNA. Further, for histological typing of tumors and examining tumor origin, immunohistochemical work up plays an important role.

Comparison of Pre-Operation Diagnosis of Thyroid Cancer with Fine Needle Aspiration and Core-needle Biopsy: a Meta-analysis

  • Li, Lei;Chen, Bao-Ding;Zhu, Hai-Feng;Wu, Shu;Wei, Da;Zhang, Jian-Quan;Yu, Li
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.17
    • /
    • pp.7187-7193
    • /
    • 2014
  • Background: The aim of this meta-analysis was to compare sensitivities and specificities of fine needle aspiration (FNA) and core needle biopsy (CNB) in the diagnosis of thyroid cancer. Materials and Methods: Articles were screened in Medline, the Cochrane Library, EMBASE and Google Scholar, and subsequently included and excluded based on the patient/problem-intervention-comparison-outcome (PICO) principle. Primary outcome was defined in terms of diagnostic values (sensitivity and specificity) of FNA and CNB for thyroid cancer. Secondary outcome was defined as the accuracy of diagnosis. Compiled FNA and CNB results from the final studies selected as appropriate for meta-analysis were compared with cases for which final pathology diagnoses were available. Statistical analyses were performed for FNA and CNB for all of the selected studies together, and for individual studies using the leave-one-out approach. Results: Article selection and screening yielded five studies for meta-analysis, two of which were prospective and the other three retrospective, for a total of 1,264 patients. Pooled diagnostic sensitivities of FNA and CNB methods were 0.68 and 0.83, respectively, with specificities of 0.93 and 0.94. The areas under the summary ROC curves were 0.905 (${\pm}0.030$) for FNA and 0.745 (${\pm}0.095$) for CNB, with no significant difference between the two. No one study had greater influence than any other on the pooled estimates for diagnostic sensitivity and specificity. Conclusions: FNA and CNB do not differ significantly in sensitivity and specificity for diagnosis of thyroid cancer.