• Title/Summary/Keyword: Fin-tube Heat Exchanger

Search Result 268, Processing Time 0.028 seconds

The Power Spectral Density Characteristics of Lift and Drag Fluctuation of Fin Tube in a Heat Recovery Steam Generator (배열회수 보일러 단일 휜튜브의 양력과 항력 변동에 따른 PSD 특성 연구)

  • Ha, Ji Soo;Lee, Boo Youn
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.2
    • /
    • pp.23-29
    • /
    • 2016
  • Heat exchanger tube array in a heat recovery steam generator is exposed to the hot exhaust gas flow and it could cause the flow induced vibration, which could damage the heat exchanger tube array. It is needed for the structural safe operation of the heat exchanger to establish the characteristics of flow induced vibration in the tube array. The researches for the flow induced vibration of typical heat exchangers have been conducted by using single cicular tube or circular tube array and the nondimensional PSD(Power Spectral Density) function with the Strouhal number, fD/U, had been derived by experimental method. From the present study, the basis for the application of flow induced vibration to the heat recovery steam generator tube array would be prepared. For the previous mentioned purpose, the present CFD analysis introduced a single fin tube and calculated with the unsteady laminar flow over the single fin tube. The characteristics of vortex shedding and lift and drag fluctuation over the fin tube was investigated. The derived nondimensional lift PSD was compared with the results of the previous experimental studies and the characteristics of lift and drag PSD over a single fin tube was established from the present CFD study.

Heat Transfer Characteristic of Finned-tube Heat Exchangers with Different Clearance between Fin Collar and Tube Surface (핀칼라와 튜브의 간극에 따른 열교환기의 열전달 특성)

  • Park, Young-Min;Jeong, Young-Man;Lee, Jae-Keun;Park, Nae-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1073-1078
    • /
    • 2009
  • Finned-tube heat exchangers are often made with aluminum fins and copper tubes. Usually the contact between fin collar and tube surface for finned tube heat exchanger is secured by mechanical expansion of the tubes. The objective of the present study is to apprehend how much effect clearance has on the performance of heat exchanger. This effect is studied using an experimental approach. The thermal fluid measurements are made using a psychometric calorimeter. Frontal air velocity varies in the range from 1.0m/s to 3.0 m/s. The heat transfer rate of sample which has bigger clearance is only 27% compare with the other's in dry condition. In wet condition, its heat transfer rate is 78% compare with the other's.

  • PDF

Numerical Analysis for Heat Transfer Characteristics of Elliptic Fin-Tube Heat Exchanger with Various Shapes (다양한 형상에 따른 타원형 핀-튜브 열교환기의 열전달 특성에 관한 수치해석)

  • Yoo, Jae Hwan;Yoon, Jun Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.4
    • /
    • pp.367-375
    • /
    • 2013
  • In this study, the characteristics of the heat transfer coefficient and pressure drop were numerically analyzed according to the axis ratio (AR), pitch, location of vortex generator, and bump phase of the tube surface about an elliptical fin-tube heat exchanger. The boundary condition for CFD analysis was decided as a tube surface temperature of 348 K and inlet air velocity of 1-5 m/s. RSM 7th turbulent model was chosen as the numerical analysis for the sensitivity level. The analysis results indicated that the AR and transverse pitch decreased whereas the heat transfer coefficient increased. On the other hand, there was little difference in the longitudinal pitch. Furthermore, the heat transfer rate was more favorable when the vortex generator was located in front of the tube. Also, the bump phase of the tube surface indicated that the pressure drop and heat transfer were more favorable with the circle type than with the serrated type.

A Study of Correlation between DCA and WHS in Fin-and-Tube Heat Exchanger (핀-관 열교환기에서 동적접촉각과 물맺힘량과의 상관관계에 관한 연구)

  • 황준현;고영환;신종민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.10
    • /
    • pp.786-791
    • /
    • 2002
  • An experimental study on the behavior of the water hold-up by spraying of a fin-and-tube heat exchanger with regard to the surface characteristics, i.e., contact angles, was conducted. The dynamic contact angles (DCA) were measured, and water hold-up by spraying (WHS) was conducted in the experiment. It is found that heat exchanger surface characteristics, spray pressure, spray water temperature and heat exchanger surface temperature play an important role in WHS. In order to evaluate relationship between WHS and surface characteristics, test conditions are determined through a contour analysis. A correlation was proposed to predict WHS as a function of DCA. With its test efficiency and consuming time, the prediction method can be used to evaluate WHS performance.

Heat Transfer Characteristics of Individual Row of Fin and Tube Heat Exchangers

  • Chang Keun-Sun;Kweon Young-Chul;Kim Young-Jae;Jeong Ji-Hwan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.2
    • /
    • pp.49-56
    • /
    • 2006
  • Heat transfer performances of individual row of two-row fin and tube heat exchangers are experimentally investigated. Tested are four heat exchangers which are geometrically identical with the exception of fin shape, slit or louver, and that the fins between the first row and the second row are connected or separated. The tube diameter and fin spacing of the heat exchangers examined are 7mm and 1.4mm, respectively. All thermal fluid measurements are made using a psychrometric calorimeter. In order to evaluate air-side heat transfer coefficients of individual rows, tube-side water flow rates of individual rows are independently controlled such that the water-side temperature drops in each row remain at $5^{\circ}C$. Frontal air velocity varies in the range from 0.7m/s to 2.5m/s. Heat transfer coefficients are presented in terms of Colburn ${\jmath}-factor$. The results show that the heat transfer coefficient of the upstream row is larger than that for the downstream row at low Reynolds numbers.

Shape Optimization of a Heat Exchanger with Internally Finned Tube (내부핀이 부착된 원형관 열교환기의 형상 최적화)

  • Lee, Ju-Hee;Lee, Sang-Hwan;Park, Kyoung-Woo;Choi, Dong-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1418-1423
    • /
    • 2004
  • Optimization of a heat exchanger with internally finned circular tubes has been performed for three-dimensional periodically fully developed turbulent flow and heat transfer. The design variables of fin number N, fin width ($d_1,d_2$) and fin height(H), are numerically optimized for the limiting conditions of $N=22{\sim}37$, $d_1=0.5{\sim}1.5$ mm, $d_2=0.5{\sim}1.5$ mm, $H=0.1{\sim}1.5$. Due to the periodic boundary conditions along main flow direction, the three layers of meshes are considered. The CFD and the mathematical optimization are coupled to optimize the heat exchanger. The flow and thermal fields are predicted using the finite volume method and the optimization is carried out by using the sequential quadratic programming (SQP) method which is widely used in the constrained nonlinear optimization problem.

  • PDF

Performance Characteristics on Environment Change of A/C applied Fin-tube and PF Heat Exchangers (환경변화에 따른 핀-관, PF 열교환기 적용 공조기 성능 특성 실험 연구)

  • Park, K.M.;Um, U.S.;Kwon, Y.C.;Lee, S.J.
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1267-1271
    • /
    • 2009
  • In the present study, performance characteristics on environment change of A/C applied fin-tube and PF heat exchangers were experimentally investigated. Capacity and COP changing an outlet air velocity, an indoor/outdoor temperature and a relative humidity were obtained. Air-enthalpy calorimeter was used. As the air velocity, indoor temperature and relative humidity increase, capacity and COP increase. PF A/C has smaller refrigerant weight than the fin-tube A/C. The performance of PF-2 A/C with the squarer fin was more excellent than that of PF-1 A/C with the triangler fin.

  • PDF

An Experimental Study on the Performance of Fin-Tube Heat Exchanger under Frosting Condition (착상조건하에서 핀-관 열교환기 성능에 관한 실험적 연구)

  • Lee, K.S.;Pak, H.Y.;Lee, T.H.;Lee, N.G.;Lee, S.Y.;Lee, M.R.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.319-328
    • /
    • 1995
  • In this study, the experiment with 2rows-2columns fin-tube heat exchanger under forced convection and frosting condition is performed. The influence of each operating condition(the temperature of air, the humidity of air, the velocity of air, the temperature of coolant) on the growth of frost layer, air-side pressure drop, and characteristics of heat transfer is investigated. The experimental results show that the frost thickness increases rapidly in the early stage of frost formation and increases linearly after sometime. The frost thickness increases with the increase of the inlet air humidity and velocity and the decrease of inlet air temperature and coolant temperature. It is also found that the total energy transfer rate increases with the increase of inlet air temperature and velocity and with the decrease of inlet air humidity and coolant temperature.

  • PDF

Heat Transfer Coefficients of Individual Rows for Fin-and-Tube Heat Exchangers (휜-관 열교환기의 열별 열전달 계수 측정)

  • Shin, T.R.;Lee, E.R.;Kim, N.H.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1034-1039
    • /
    • 2004
  • The row-by-row heat transfer characteristics of fin-and-tube heat exchangers having wavy fins were experimentally investigated. Three samples having different rows (one, two and three) were tested. Results show that the heat transfer coefficient is strongly dependent on the tube row. The heat transfer coefficient of the first row is larger than those of second or third rows. However, the difference decreases as the Reynolds number increases. The heat transfer coefficients of the second and the third row are approximately the same, probably due to increased mixing of bulk flow by wavy channels. Although samples have different tube row, the heat transfer coefficients of same row are approximately the same.

  • PDF

Study on Heat Transfer Characteristic of Shell-and-Tube Heat Exchanger with Plate Fin (판형 핀을 가진 원통-다관형 열교환기의 열전달 특성에 관한 연구)

  • Lim, Tae-Woo;Cho, Dong-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.46-51
    • /
    • 2009
  • In this work, the experimental investigation was carried out to evaluate the heat transfer performance on the shell side of shell-and-plate finned tube heat exchanger with three different tube numbers(9, 13 and 19). Oil flowing on the shell side was cooled by cold water flowing inside the tubes. A shell-and-tube heat exchanger of an oil cooler consisted of one shell pass and two tube passes with the inner tube diameter of 8.82 mm and the tube length of 575 mm. Mass flow rate was varied from 1.2 to $6.0\;m^3/h$ for oil and from 0.6 to $3.0\;m^3/h$ for cold water, respectively. From the experiment of shell-and-plate finned tube heat exchanger, the overall heat transfer coefficient of heat exchanger with 9 tubes was compared with that of 13 and 19 tubes. It was found that the heat transfer coefficients in shell side of heat exchanger with 9 plate finned tubes showed averagely 1.8 times and 2.3 times higher than those of 13 and 19 tubes, respectively.