• 제목/요약/키워드: Fin conduction

검색결과 49건 처리시간 0.026초

Heat Sink의 특성확인을 위한 수치적 Simulation (A NUMERICAL SIMULATION FOR THE PERFORMANCE CHARACTERIZATION OF HEAT SINKS)

  • 김창녕;문성일
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제3권2호
    • /
    • pp.147-156
    • /
    • 1999
  • A numerical simulation has been carried out for the performance characterization of heat sinks in electronic equipment. Heat transfer characteristics have been analyzed for various design parameters including the shape of heat sink, thickness of fin base and fin pitches. A commercial program called Flotherm has been employed for the numerical calculation. Optimal design of the heat sink has been persued which is closely related with the reduction of heat resistance involved in conduction and convection of heat.

  • PDF

열교환기 휜에서의 서리 성장 (Growth of frost formed on heat exchanger fins)

  • 안원준;김정수;이관수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.256-261
    • /
    • 2008
  • In this study, frost behavior on two dimensional fins of a heat exchanger was experimentally investigated. Temperature distribution on a 2-D fin surface and frost properties were measured in the directions perpendicular to and parallel to airflow. The results indicated that the temperature gradient in the direction perpendicular to airflow was large because of fin heat conduction, while that in the direction parallel to airflow was very small. Frost thickness in the airflow direction decreased from the leading edge towards the trailing edge of the fin due to leading edge effect. The reduction rate of frost thickness in the airflow direction, however, was very small compared with that in the direction perpendicular to the airflow, as affected by the temperature distribution.

  • PDF

불균일한 온도분포를 갖는 열교환기 휜에서의 착상 특성 (Characteristics of Frost Formed on Heat Exchanger Fins of Non-Uniform Temperature Distribution)

  • 안원준;김정수;이관수
    • 설비공학논문집
    • /
    • 제21권7호
    • /
    • pp.373-379
    • /
    • 2009
  • In this study, frosting experiment was conducted to investigate the characteristics of frost formed on heat exchanger fins of non-uniform temperature distribution. Temperature distribution and frost characteristics of a 2-D fin surface were investigated in the airflow direction and the direction perpendicular to airflow. Temperature gradient was very small in the airflow direction, while it was large in the direction perpendicular to airflow due to fin heat conduction. The variations of the frost thickness gradient and the frost density gradient in the direction perpendicular to airflow were significant. On the other hand, the temperature gradient on frost surface in the direction perpendicular to airflow was significant at the early stage of frosting, while it decreased gradually as time elapsed.

나노구조 FinFET에서 게이트산화막의 특성에 따른 터널링의 변화분석 (Analysis of Tunneling Transition by Characteristics of Gate Oxide for Nano Structure FinFET)

  • 정학기
    • 한국정보통신학회논문지
    • /
    • 제12권9호
    • /
    • pp.1599-1604
    • /
    • 2008
  • 본 연구에서 나노구조 FinFET 제작시 게이트산화막 특성이 서브문턱영역에서 전송특성에 미치는 영향을 분석하고자 한다. 이를 위하여 분석학적 전송모델을 사용하였으며 분석학적 모델을 유도하기 위하여 포아슨방정식을 이용하였다. 나노구조 FinFET에서 문턱전압이하의 전류전도에 영향을 미치는 열방사전류와 터널링전류에 대하여 분석하였으며 본 연구의 모델이 타당하다는 것을 입증하기 위하여 서브문턱스윙값을 이차원 시뮬레이션값과 비교하였다. 결과적으로 본 연구에서 제시한 전송특성모델이 이차원 시뮬레이션모델과 매우 잘 일치하였으며 FinFET의 전송특성이 게이트산화막의 특성에 따라 매우 큰 변화를 보이는 것을 알 수 있었다. 특히 게이트길이가 작아지면서 전송특성에 커다란 영향을 미치는 터널링특성에 대하여 집중적으로 분석하였다.

적외선 검출기용 극저온 챔버에서 복사 차폐막을 고려한 열해석 (Thermal Analysis of a Cryochamber for an Infrared Detector Considering a Radiation Shield)

  • 김영민;강병하
    • 설비공학논문집
    • /
    • 제18권8호
    • /
    • pp.672-677
    • /
    • 2006
  • The steady cooling characteristics of a cryochamber for infrared (IR) detector have been investigated analytically, considering radiation shields. The thermal modeling considers the conduction heat transfer through cold finger, the gaseous conduction due to out-gassing, and the radiation heat transfer. The cooling load of the cryochamber is obtained by using a fin equation. The results obtained indicate that the gaseous conduction plays an important role in determining the steady cooling load. The steady cooling load is increased as the gas pressure is increased. It is also found that the cooling load is substantially decreased with a radiation shield. The most thermal load of a cryochamber occurs through the cold finger.

휜의 열전도를 고려한 평판 휜에서의 착상 거동 (Behaviors of Frost Formation on a Plate Fin Considering Fin Heat Conduction)

  • 김정수
    • 대한설비공학회지:설비저널
    • /
    • 제38권12호
    • /
    • pp.51-60
    • /
    • 2009
  • 본 연구에서는 착상 조건 하에서 열교환기 휜의 열전도를 고려하여 휜 표면에서의 착상 거동을 예측하기 위하여 수학적 모델을 제시한다. 이 때, 공기측은 착상 현상에 대한 3차원 유동 변화의 영향을 고려한다. 서리층 두께에 대한 해석 결과는 실험 결과를 최대 10% 오차 내에서 잘 예측한다. 유동에 수직한 방향(z-dir.)의 서리층 두께 성장은 휜의 열전도에 의해 휜 바탕 근처에서 활발하고, 휜 끝으로 갈수록 지수함수적으로 둔화된다. 휜의 열전도를 고려한 경우에 비해 휜의 표면온도가 일정한 조건에서 서리층 두께는 최대 2배, 열전달량은 평군 10% 정도 과대 예측한다. 따라서, 열교환기 휜에서의 착상 거동을 정확하게 예측하기 위해 착상 모델 해석 시 휜의 열전도를 고려해야 한다. 휜의 열전도 고려 유무에 따른 착상 거동의 차이를 보완하기 위해 열전달량에 대한 등가온도를 산출하며, 이를 근거로 무차원 등가 온도 상관식을 도출한다.

  • PDF

직사각형 휜이 부착된 실린더 블럭의 정상 및 비정상 열전도 해석 (Analysis of the Stedy and Unsteady Heat Conduction in the Cylinder Block Attached with Rectangular Fin)

  • 이건휘;최영돈
    • 대한기계학회논문집
    • /
    • 제14권5호
    • /
    • pp.1254-1263
    • /
    • 1990
  • 본 연구에서는 기관 실린더 사이의 거리와 기관 블럭의 외벽에 부착된 윈이 실린더내벽면 온도분포에 미치는 영향을 알아보기 위하여 2차원 정상.비정상 열전도 해석을 하였다. 물론 2차원 열전도 해석 결과는 전 실린더 블럭에 적용할 수 있는 것은 아니며 블럭의 상단과 하단 부근에서는 적용시키기 어렵고 중간 부근에서만 적용 할수 있는 것이지만, 2차원 해석을 통해서 격자의 수를 대단히 많이 늘일 수 있어서 그해의 정확도를 높힐 수 있기 때문에 실린더 사이의 간격과 휜의 크기 등이 실린더 내벽면 온도에 미치는 영향, 정상.비정상 해석의 차이점 등을 명확히 규명할 수 있는 잇점이 있어서 본 연구에서 채택하였다.따라서 본 해석 결과는 전 실린더에 대해서 국부적으로 적용될 수 있는 것이 아니라 전 실린더에서의 값에 대한 평균 값으로 이해 되어야 할 것이다.

상-파넬 히-팅의 해석법 (Steady and Transient Solution of heat Conduction from hurried Pipes of panel heating Slab)

  • 이건
    • 대한설비공학회지:설비저널
    • /
    • 제3권3호
    • /
    • pp.185-190
    • /
    • 1974
  • Floor panel heating system is popular in Korea as dwelling house heating system. There are two methods for keeping floor surface warm. One method is delivering warm air under the floor such as Roman Hypocaust and Korean traditional Ondol. The other method is imbedding hot water pipes into the concrete floor slab. This paper gives basic equations for steady and transient solutions of heat conduction from hurried pipes. For steady-state solution, fin Efficiency Method and Sink and Source Method were introduced. Sink and Source Method is applied to transient state and basic solution is given in the form of Exponential Integral Function. Numerical solutions can be solved easily by digital computer from these equations.

  • PDF

Nickel/Metal Hydride 전지의 열관리기술 개발 (Thermal Management of a Nickel/Metal Hydride Battery)

  • 김준범
    • 공업화학
    • /
    • 제8권4호
    • /
    • pp.667-672
    • /
    • 1997
  • 고용량 Nickel/Metal hybride 전지의 온도 거동을 3차원 유한요소법 software인 NISA를 사용하여 해석하였다. 전지 내부의 열전도에는 미분형 에너지 수지식을, 외부 대기와의 접촉면은 대류 열전달 방식을 사용하였다. 전지 온도에 영향을 미치는 요소인 열발생량과 대류 열전달계수에 대한 실험을 행하였고, 이 결과로부터 일반식을 도출하였다. 금속 재질의 cooling fin을 사용하므로써 급속한 충전이나 방전시 야기될 수 있는 온도 상승을 상당 부분 방지할 수 있었다. 전지 외벽에 열전도도가 낮고 얇은 절연물질을 부착하여도 최고온도의 상승에 미치는 영향은 미미하였다.

  • PDF