• Title/Summary/Keyword: Fin Performance

Search Result 574, Processing Time 0.027 seconds

Comparative Study on the Structural Dependence of Logic Gate Delays in Double-Gate and Triple-Gate FinFETs

  • Kim, Kwan-Young;Jang, Jae-Man;Yun, Dae-Youn;Kim, Dong-Myong;Kim, Dae-Hwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.10 no.2
    • /
    • pp.134-142
    • /
    • 2010
  • A comparative study on the trade-off between the drive current and the total gate capacitance in double-gate (DG) and triple-gate (TG) FinFETs is performed by using 3-D device simulation. As the first result, we found that the optimum ratio of the hardmask oxide thickness ($T_{mask}$) to the sidewall oxide thickness ($T_{ox}$) is $T_{mask}/T_{ox}$=10/2 nm for the minimum logic delay ($\tau$) while $T_{mask}/T_{ox}$=5/1~2 nm for the maximum intrinsic gate capacitance coupling ratio (ICR) with the fixed channel length ($L_G$) and the fin width ($W_{fin}$) under the short channel effect criterion. It means that the TG FinFET is not under the optimal condition in terms of the circuit performance. Second, under optimized $T_{mask}/T_{ox}$, the propagation delay ($\tau$) decreases with the increasing fin height $H_{fin}$. It means that the FinFET-based logic circuit operation goes into the drive current-dominant regime rather than the input gate load capacitance-dominant regime as $H_{fin}$ increases. In the end, the sensitivity of $\Delta\tau/{\Delta}H_{fin}$ or ${{\Delta}I_{ON}}'/{\Delta}H_{fin}$ decreases as $L_G/W_{fin}$ is scaled-down. However, $W_{fin}$ should be carefully designed especially in circuits that are strongly influenced by the self-capacitance or a physical layout because the scaling of $W_{fin}$ is followed by the increase of the self-capacitance portion in the total load capacitance.

Pool Boiling Heat Transfer Charcteristics of Low-Fin Tubes in CFC11, HCFC123 and HCFC141b (CFC11, HCFC123, HCFC141b 풀내에서 낮은 핀관의 비등 열전달특성)

  • 김주형;곽태희;김종보
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.9
    • /
    • pp.2316-2327
    • /
    • 1995
  • Experimental results from nucleate pool boiling heat transfer with various finned tubes in CFC11, HCF123 and HCFC141b are reported. One plain tube and four low fin tubes of various fin densities were tested in an attempt to find out the optimum fin density in the heat flux range of 10-60 kW/m$^{[-992]}$ at near atmospheric pressure. The results indicated that CFC11 showed the highest heat transfer coefficients. Its alternatives, HCFC123 and HCFC141b, showed 3-5% lower heat transfer coefficients than those of CFC11 at the same heat flux. As the fin density increases, so does the heat transfer surface area. Measured heat transfer coefficients, however, do not necessarily always increase as the fin density increases. This unique phenomenon seems to be caused by the coalescence of the bubblers that prevent the cool liquid from entering into the fin valleys. For all the refrigerants tested, the optimum fin density yielding the highest performance was 28 fins per inch confirming the previous results by other researchers.

The Performance Comparison of $CO_2$ Gascooler and Evaporator with Heat Exchanger Type (열교환기 형태에 따른 이산화탄소용 가스쿨러와 증발기의 성능비교)

  • Bae, Kyung-Jin;Cho, Hong-Hyun
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.6 no.2
    • /
    • pp.15-22
    • /
    • 2010
  • The natural refrigerants have used into HVAC equipments because the CFCs and HFCs have some environmental problems like high ODP and GWP. The carbon dioxide has small effect on the environmental problem but also good thermodynamics properties. In this study, the simulation study on the performance and characteristics of a $CO_2$ gascooler and evaporator using a fin-tube and microchannel heat exchanger has been conducted. Besides, the comparison of performance with operating condition was carried out in order to apply to the $CO_2$ heat pump system. As a result, the front sizes of a gascooler and evaporator using a microchannel were decreased by 63% and 58%, respectively, compared to those using a fin-tube. The performance of the fin-tube gascooler and evaporator were more responsive to the variation of operating conditions compared to that of microchannel. The pressure drop of a fin-tube heat exchanger was higher than that of a microchannel one.

Heat Transfer and Combustion Characteristics and Performance of U type Radiation Tube Burner with fin (핀 부착 U형 복사튜브 버너의 열전달 및 연소성능 실험)

  • Lee, Hyun-Chan;You, Hyun-Seok;Lee, Joong-Seong
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.516-521
    • /
    • 2001
  • Present study deals with combustion characteristics and performance of U type radiation tube burner with fin which combustion capacity is 30,000kcal/hr and the maximum capacity of supply fuel is $30Nm^{3}/hr$. Temperature difference of radiation tube is about $173^{\circ}C$ at 25% capacity and this show relatively small temperature difference for convenient type. Thermal efficiency is satisfactory as $72{\sim}81%$. Also, radiative efficiency of radiation tube is $52{\sim}73%$. The efficiency of heat exchanger is $27{\sim}37%$. Therefore, radiative efficiency is improved to $1{\sim}10%$ after installing fin.

  • PDF

On the Influence of End Plates upon the Tip Vortex Cavitation Characteristics of a Fin Stabilizer (안정기 핀의 팁 보오텍스 캐비테이션 특성에 미치는 날개 끝판의 효과)

  • Seo, Dae-Won;Kim, Joung-Hyun;Lee, Seung-Hee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.1
    • /
    • pp.18-28
    • /
    • 2008
  • Fins are widely used for roll stabilization of passenger ferries and high performance naval ships, among others. In the present study, numerical simulations are performed to investigate the influence of end-plates upon the cavitation characteristics of a stabilizer fin for various angles of attack and speeds and the results are verified through a series of model experiments. It is found that a considerable retardation in tip vortex cavitation can be achieved with attachment of end-plates at the tip of the stabilizer fin. The results can be utilized for the design of stabilizer fins as well as the development of high performance control devices for ships.

Experimental Parameter Identification and Performance Analysis of a Fish Robot with Ostraciiform Swimming Mode using Rigid Caudal Fins (고체형 꼬리 지느러미로 오스트라키폼 유영을 하는 물고기 로봇의 패러미터 식별 및 성능 분석)

  • Chan, Wai Leung;Lee, Gi-Gun;Kim, Byung-Ha;Choi, Jung-Min;Kang, Tae-Sam
    • The Journal of Korea Robotics Society
    • /
    • v.5 no.3
    • /
    • pp.197-208
    • /
    • 2010
  • The ostraciiform swimming mode allows the simplest mechanical design and control for underwater vehicle swimming. Propulsion is achieved via the flapping of caudal fin without the body undulatory motion. In this research, the propulsion of underwater vehicles by ostraciiform swimming mode is explored experimentally using an ostraciiform fish robot and some rigid caudal fins. The effects of caudal fin flapping frequency and amplitude on the cruising performance are studied in particular. A theoretical model of propulsion using rigid caudal fin is proposed and identified with the experimental data. An experimental method to obtain the drag coefficient and the added mass of the fish robot is also proposed.

CFD Analysis of Offset Strip Fin with a Gap between Rows (CFD를 이용한 핀의 열 사이에 간극을 가지는 Offset Strip Fin의 성능 해석)

  • Hwang, Seongwon;Jeong, Ji Hwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.8
    • /
    • pp.381-387
    • /
    • 2014
  • The off-set strip fins (OSF) have been widely used to construct plate-fin heat exchangers. Conventional OSF is constructed in successive rows of fins. New OSF structure is suggested to have a gap between adjacent rows of fins. The gap is intended to reduce fouling by allowing small objects to flow through fins. The objective of this work is to investigate the performance of off-set strip fins with gap between successive rows. Results showed that the performance of OSF with gap can't be predicted by previous correlation.

The Study on Absorption Performance of a Plate-Fin Type Absorber (플레이트-휜형 흡수기의 흡수성능에 대한 연구)

  • 강인석;김남진;김종보
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.7
    • /
    • pp.557-563
    • /
    • 2001
  • Small capacity gas absorption systems for cooling and heating have been favorably considered to reduce the seasonal imbalance of electrical loads and LNG consumption recently. A multifunctional plate-fin heat exchanger was adopted as an absorber and the performance was tested and analyzed to reduce the size and weight of the absorption heat pump. The test was performed using breadboard type ammonia absorption machine. The performance was compared with the plate type absorber and there was little difference in heat and mass transfer characteristics. The heat and mass transfer performance was a function of poor solution and vapor flow rates and the mass transfer was dependent on vapor flow rate more than heat transfer.

  • PDF

Thermal Performance Analysis of a Shell-and-Tube Heat Exchanger with Plate Fins of Various Shape (다양한 형상의 판형 휜을 장착한 원통다관형 열교환기의 열성능 해석)

  • 신지영;손영석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.648-656
    • /
    • 2004
  • In this study, a highly efficient shell-and-tube heat exchanger with plate fins is considered to improve thermal performance of the conventional shell-and-tube heat exchanger. This type of shell-and-tube heat exchanger with plate fins of various shape is simulated three-dimensionally using a commercial thermal-fluid analysis code. CFX4.4. The effect of the shape of the plate fin on heat transfer characteristics is also investigated by the simulation. Plate fins of four different shapes. plane, plane-slit. wave. and wave-slit fins, are considered. The flow fields, pressure drop and heat transfer characteristics in the heat exchanger are calculated. It is proved that the shell-and-tube heat exchanger with plate fins is superior to the conventional shell-and-tube heat exchanger without plate fins in terms of heat transfer. The shape of the plate fin is important in the performance of a heat exchanger such as heat transfer and pressure drop.

Experimental Study on the Effect of Tip Clearance for a Straight Fin Heat Sink (팁 클리어런스가 스트레이트 휜 히트싱크의 냉각성능에 미치는 영향에 관한 실험적 연구)

  • Kim, Jin-Wook;Kim, Sung-Jin;Min, Jung-Im;Lee, Seung-Gyu
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1189-1194
    • /
    • 2004
  • In this paper, the effect of tip clearance on the cooling performance of the microchannel heat sink is presented under the fixed pumping power condition. For the various types of microchannel heat sink having different size of fin width and channel width, experimental study is conducted. Through the experiment, the tip clearance effect is investigated by increasing tip clearance from zero. As a result, it is shown that cooling performance of heat sink with tip clearance is better than that of heat sink without tip clearance. For the microchannel heat sink with tip clearance, the optimum conditions for cooling performance is also studied.

  • PDF