• 제목/요약/키워드: Filtration type

검색결과 304건 처리시간 0.03초

연속공정에 의한 UF용 폴리이미드 분리막의 제조

  • 김완주;전종영;탁태문
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1995년도 춘계 총회 및 학술발표회
    • /
    • pp.45-45
    • /
    • 1995
  • Filtration, one of the most important process in the various industrials, is defined as the separation of two or more compounds from a fluid by passing the mixture refers to the separation of solid, immisible particles from liquid or gaseous mixture. Membrane filtration which is a type of filtration extends it's application further to include the separation, concentration, and filtration. The main objective of this investigation is the preparation of organic solvents-resistant polyimide membranes by using phase inversion technique and their application as a UF membrane. Specially, the dope solution was prepared from the newly developed method. The newly developed method is that the dope solution was directly prepared from the polyimide solution which was prepared by the modified one-step polymerization. The effects of the parameters for membrane preparation such as the casting solution composition and the casting conditions were investigated and the performance and chemical stabfiity of membrane are going to be tested.

  • PDF

디젤엔진 연소공기 습식여과기의 개발에 관한 연구 (A Study on Development of the Wet Type Filter for Combustion Air of Diesel Engine)

  • 김용석;박성호;양순용
    • 한국공작기계학회논문집
    • /
    • 제17권1호
    • /
    • pp.158-164
    • /
    • 2008
  • In this paper, the performance of wet type filter for diesel engine combustion air has been studied with effects of air temperature, humidity, and pressure. After experiments are performed without diesel engine, it has been investigated the applicability to diesel engine. Wet type filter for diesel engine combustion air had advantages that it is not necessary to change air filter and that engine exhaust gas is environmentally friendly due to low NOx and particulate emission. Also, the filtration performance has been carried out with smoke shell.

다중회귀모형을 이용한 벤츄리가 없는 충격기류식 여과집진장치 압력손실 예측 (Pressure Drop Predictions Using Multiple Regression Model in Pulse Jet Type Bag Filter Without Venturi)

  • 서정민;박정호;조재환;진경호;정문섭;이병인;홍성철;시바쿠마르;최금찬
    • 한국환경과학회지
    • /
    • 제23권12호
    • /
    • pp.2045-2056
    • /
    • 2014
  • In this study, pressure drop was measured in the pulse jet bag filter without venturi on which 16 numbers of filter bags (Ø$140{\times}850{\ell}$) are installed according to operation condition(filtration velocity, inlet dust concentration, pulse pressure, and pulse interval) using coke dust from steel mill. The obtained 180 pressure drop test data were used to predict pressure drop with multiple regression model so that pressure drop data can be used for effective operation condition and as basic data for economical design. The prediction results showed that when filtration velocity was increased by 1%, pressure drop was increased by 2.2% which indicated that filtration velocity among operation condition was attributed on the pressure drop the most. Pressure was dropped by 1.53% when pulse pressure was increased by 1% which also confirmed that pulse pressure was the major factor affecting on the pressure drop next to filtration velocity. Meanwhile, pressure drops were found increased by 0.3% and 0.37%, respectively when inlet dust concentration and pulse interval were increased by 1% implying that the effects of inlet dust concentration and pulse interval were less as compared with those changes of filtration velocity and pulse pressure. Therefore, the larger effect on the pressure drop the pulse jet bag filter was found in the order of filtration velocity($V_f$), pulse pressure($P_p$), inlet dust concentration($C_i$), pulse interval($P_i$). Also, the prediction result of filtration velocity, inlet dust concentration, pulse pressure, and pulse interval which showed the largest effect on the pressure drop indicated that stable operation can be executed with filtration velocity less than 1.5 m/min and inlet dust concentration less than $4g/m^3$. However, it was regarded that pulse pressure and pulse interval need to be adjusted when inlet dust concentration is higher than $4g/m^3$. When filtration velocity and pulse pressure were examined, operation was possible regardless of changes in pulse pressure if filtration velocity was at 1.5 m/min. If filtration velocity was increased to 2 m/min. operation would be possible only when pulse pressure was set at higher than $5.8kgf/cm^2$. Also, the prediction result of pressure drop with filtration velocity and pulse interval showed that operation with pulse interval less than 50 sec. should be carried out under filtration velocity at 1.5 m/min. While, pulse interval should be set at lower than 11 sec. if filtration velocity was set at 2 m/min. Under the conditions of filtration velocity lower than 1 m/min and high pulse pressure higher than $7kgf/cm^2$, though pressure drop would be less, in this case, economic feasibility would be low due to increased in installation and operation cost since scale of dust collection equipment becomes larger and life of filtration bag becomes shortened due to high pulse pressure.

입상여과에서 액반플럭의 부착 (Alum Floc Attachment in Granular Media Filtration)

  • 김진근
    • 한국물환경학회지
    • /
    • 제20권6호
    • /
    • pp.625-630
    • /
    • 2004
  • 입상여과는 표준식 정수처리 공정에서 입자물질 제거의 최종공정으로 대부분 사용되고 있다. 따라서 양질의 수돗물을 만들기 위해서는 입상여과에서 높은 수준의 입자물질 제거가 요구되고 있다. 그러나 여과공정에서 모든 입자물질을 제거할 수 없으며, 또한 입자물질의 부착특성은 입자와 용액의 물리화학적 특성에 따라 달라진다. 실험실규모의 여과칼럼과 입경 0.55mm의 유리구슬을 여재로 한 여과실험이 수행되었다. Min-U-Sil 5가 입자물질로 사용되었으며 입자물질을 불안정화하기 위하여 액반을 사용하였다. 운전조건은 표준입상여과와 동일하였으며 여과속도는 5m/h 였다. 입자와 여재가 모두 음의 표면전하를 갖을 경우 작은 표면 전하를 갖는 입자가 여과초기에 여재에 잘 부착되었다. 작은 표면전하를 갖는 입자의 선택적 부착은 유출수의 제타 전위분포를 더 음인 방향으로 이동시켰다. 한편 입자의 표면전하가 양의 값을 갖을 경우는 여과수 입자의 표면전하가 양의 큰 값에서 작은 값으로 변하였는데 이는 입자와 여재사이의 이온전이에 기인하는 것으로 생각된다.

Usable water production from coal seam gas water with a combination of pore control fiber filtration and reverse osmosis

  • Shin, Choon Hwan;Bae, Jun Seok
    • Environmental Engineering Research
    • /
    • 제23권2호
    • /
    • pp.210-215
    • /
    • 2018
  • Coal seam gas (CSG) water, to be discharged, has been usually treated in reverse osmosis (RO) plants which require extensive and expensive pre-treatment. However, current low gas prices have been a great driver for relevant industries to seek for alternative cost-effective technologies in the aspect of its beneficial use and fit-for-purpose usable water production. In this paper, a combined system with a two-stage pore control fiber (PCF) filtration and a RO system was designed and tested for CSG water treatment. Also, a coagulation reactor was placed in front of the PCF to further enhance suspended solid removal. More than 99% of SS were removed through the PCF filtration while organic, total nitrogen and total phosphorous were mostly removed by the RO system. Especially along with a decrease in conductivity, the total dissolved solid derived from salts was mainly removed in the RO system. Having $OH^-$ undetected, $HCO_3{^-}$ was found to be a dominant compound and its removal efficiency was 97-98% after the RO treatment. And a Fe(III) type of Polytetsu, which was the first to be tested in this paper, was found to be a better option than a Al(III) type of Poly Aluminium Chloride due to its greater coagulation efficiency and applicability at a broader range of pH than the Al(III) type. In addition, there was no noticeable change in oxidation reduction potential, suggesting that an additional process is required to oxidize non-ionic organic carbons (detected as total organic carbon).

산업용 필터백의 구조에 따른 여과성능 특성 (Filtration Performance Characteristics according to Filter Bag Structure for Application of Industries)

  • 전성민;;이강산;이재랑;김광득;박영옥
    • 한국대기환경학회지
    • /
    • 제32권4호
    • /
    • pp.384-393
    • /
    • 2016
  • In this study, two kinds of industrial filter bags were tested for their filtration performance to apply the existing bag filter systems. Experimental variables were examined for pressure drop, cleaning interval, residual pressure drop, cleaning efficiency, fractional grade efficiency, total collection efficiency according to the filter bag structure. According to these results, the filter bags tested in this study demonstrated good performance in dust collection. This was also true for the double surface filter bag. The lifetime was longer than the round type filter bag because the filtration area was more than 1.6 times wider and the filter quality factor was much higher. Therefore, double surface filter bags are suggested to be used in order to increase filtration performance of the bag filter systems.

여과-Plasma 공정을 이용한 Ralstonia Solanacearum 불활성화 (Inactivation of Ralstonia Solanacearum using Filtration-Plasma Process)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제23권6호
    • /
    • pp.1165-1173
    • /
    • 2014
  • For the field application of dielectric barrier discharge plasma reactor in nutrient solution culture, a filtration-DBD (dielectric barrier discharge) plasma reactor was investigated for the Ralstonia solanacearum which causes bacterial wilt in aquiculture. The filtration-DBD plasma reactor system of this study was consisted of filter, plasma reactor, reservoir. The DBD plasma reactor consisted of a quartz dielectric tube, discharge electrode (inner) and ground electrode (outer). The experimental results showed that the inactivation of R. solanacearum with filter media type in filter reactor ranked in the following order: anthracite > fiber ball > sand > ceramic ball > quartz ceramic. In filtration + plasma process, disinfection effect with the voltage was found to small. In disinfection time of 120 minutes, residual R. solanacearum concentration was 1.17 log (15 CFU/mL). When the continuous disinfection time was 120 minute, disinfection effect was thought to keep the four days. In sporadic operation mode of 30 minutes disinfection - 24 hours break, residual R. solanacearum concentration after five days was 0.3 log (2 CFU/mL). It is considered that most of R. solanacearum has been inactivated substantially.

Comparison of Gene Coding Clones Content in In vivo and In vitro Methyl-Filtration Libraries of Maize(Zea may)

  • Lee, Myung-Chul;Wing, Rod A;Suh, Seok-Cheol;Eun, Moo-Young
    • 한국자원식물학회지
    • /
    • 제20권6호
    • /
    • pp.491-498
    • /
    • 2007
  • It has been hypothesized that efficient exclusion of methylated retrotransposons and repeated DNA region is one of the rapid and cost-effective approaches for comprehensive gene discovery in large genome size of maize. Three kinds of methylation-sensitive restriction enzymes, HapII, MspI and McrBC, were used to identify the restriction frequency of cytosine methylation sites in maize genome. Roughly 60% of total maize genomic DNA was restricted less than 500bp by McrBC, and the most of restricted small size fraction was composed retrotransposon. In order to validate the efficient construction of gene-rich shotgun library, we compare two gene-rich methyl-filtration shotgun libraries using in vivo and in vitro methyl-filtration system. The size selected DNA fraction by Sau3A-McrBC enzyme treated was very stable and has not appeared modification in E. coli, but most insert DNA size of partially digested with Sau3A were decrease less than 500bp by bacterial methylation-modification system. In compare of retroelements portion, A 44.6% of the sequences were retroelement in unmethyl-filtered library, and the most of them was Copia type, such as Prem, Opie and Ji. The portion of retroelement was drastically decreased to 25% and 20% by in vivo and in vitro filtration system, respectively.

간헐탈진형 충격기류식 여과집진장치의 여과포 반사거리 예측 (Prediction of Off-line Type Pulse Air Jet Bag Filter Reflection Distance)

  • 손정삼;정용현;서정민
    • 한국환경과학회지
    • /
    • 제32권11호
    • /
    • pp.801-809
    • /
    • 2023
  • The purpose of this study is to predict the reflection distance following to the pulsing pressure, total air supplying, filter bag size using numercial analysis techniques and use it as an efficient operation condition and economic data for off-line type pulse air jet bag filter. In this research, filtration area 6 m2 condition, calculate filter resistance coefficient for simulation through the main experiments using coke dust. Ansys fluent V19.0 apply to CFD simulation, and analysis pulsing characteristics about pulsing pressure, filtration velocity and nozzle diameter. The maximum reflecting distance of off-line type pulse air jet bag filter is 1,000 mm regardless of total air supplying at over the 42 L/m2 conditions, that indicates off-line type can extend filter bag length 1,000 mm than on-line type. In order to effective primary and secondary pulsing of off-line type pulse air jet bag filter, over the 5 bar of pulsing pressure and over the 42 L/m2 of total air supplying are needed.

한국환자유래의 녹농균 90-2-2205로부터 S형 Pyocin의 정제 및 특성 (Purification and Characterization of the S-type Pyocin of Pseudomonas aeruginwa 90-2-2205 Isolated from Korean Patients)

  • 김란숙;이정미;박영덕;진익렬;김병오
    • 한국미생물·생명공학회지
    • /
    • 제21권2호
    • /
    • pp.132-138
    • /
    • 1993
  • The s-type pyocin was purified from the lysate of the mitomycin C-induced Pseudomonas aeruginosa 90-2-2205 cells by the other of ammonium sulfate precipitation, DEAE-Sephadex A-50 chromatography and Sephadex G-200 gel filtration. The purity was confirmed by the polyacry-lamide gel electrophoresis. The molecular weight of the purified pyocin was estimated 180, 000 by gel filtration. The pyocin was analyzed to be a complex of some polypeptides by the SDS-PAGE. The pyocin was stable by heat treatment and at pH 6-7.5 by adding 10-3% gelatin and 0.2M NaCl to the 10mM Tris-HCl buffer (pH7.5). Its killing action against the sensitive cells was assumably a single hit process.

  • PDF