• Title/Summary/Keyword: Filtration experiment

Search Result 202, Processing Time 0.024 seconds

Evaluation of Hydraulic Conductivity of Bentonite Filter Cake Using Modified Fluid Loss Test

  • Nguyen, The Bao;Lee, Chul-Ho;Yang, Jung-Hun;Choi, Hang-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.498-507
    • /
    • 2008
  • The mixture of bentonite powder and water is generally used to maintain the stability of excavation surface during the construction of vertical cutoff walls. The filter cake on the sidewall surface is the result of filtration of slurry into the adjacent soil formation. The filter cake is believed to have a very low hydraulic conductivity compared to that of the cutoff wall. This paper evaluates hydraulic conductivities of bentonite filter cakes set up with three types of bentonites under various pressure levels. A modified fluid loss test was employed in this experiment. Theory of filtration process was reviewed to explain the procedure in the present experiment. Hydraulic conductivity of the filter cakes with consideration of the filter medium resistance was evaluated. The results of the experiment with two calculation methods and discussion are presented to show the efficiency of the modified fluid loss test.

  • PDF

Evaluation of Hydraulic Conductivity of Bentonite Filter Cake Using Modified Fluid Loss Test

  • Nguyen, The Bao;Lee, Chul-Ho;Yang, Jung-Hun;Choi, Hang-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1502-1511
    • /
    • 2008
  • The mixture of bentonite powder and water is generally used to maintain the stability of excavation surface during the construction of vertical cutoff walls. The filter cake on the sidewall surface is the result of filtration of slurry into the adjacent soil formation. The filter cake is believed to have a very low hydraulic conductivity compared to that of the cutoff wall. This paper evaluates hydraulic conductivities of bentonite filter cakes set up with three types of bentonites under various pressure levels. A modified fluid loss test was employed in this experiment. Theory of filtration process was reviewed to explain the procedure in the present experiment. Hydraulic conductivity of the filter cakes with consideration of the filter medium resistance was evaluated. The results of the experiment with two calculation methods and discussion are presented to show the efficiency of the modified fluid loss test.

  • PDF

Filtration-induced pressure evolution in permeation grouting

  • Zhou, Zilong;Zang, Haizhi;Wang, Shanyong;Cai, Xin;Du, Xueming
    • Structural Engineering and Mechanics
    • /
    • v.75 no.5
    • /
    • pp.571-583
    • /
    • 2020
  • Permeation grouting is of great significance for consolidating geo-materials without disturbing the original geo-structure. To dip into the filtration-induced pressure increment that dominates the grout penetration in permeation grouting, nonlinear filtration coefficients embedded in a convection-filtration model were proposed, in which the volume of cement particles in grout and the deposited particles of skeleton were considered. An experiment was designed to determine the filtration coefficients and verify the model. The filtration coefficients deduced from experimental data were used in simulation, and the modelling results matched well with the experimental ones. The pressure drop revealed in experiments and captured in modelling demonstrated that the surge of inflow pressure lagged behind the stoppage of flow channels. In addition, both the consideration of the particles loss in liquid grout and the number of filtrated particles on pore walls presented an ideal trend in filtration rate, in which the filtration rate first rose rapidly and then reached to a steady plateau. Finally, this observed pressure drop was extended to the grouting design which alters the water to cement (W/C) ratio so as to alleviate the filtration effect. This study offers a novel insight into the filtration behaviour and has a practical meaning to extend penetration distance.

Experimental Analysis on Filtration-Permeation: Influence of the Type and Sheets of Filter Media, and Filtration Pressure (여과-투과에 대한 실험적 분석: 여과매체의 종류, 여과매체의 매수, 여과압력의 영향)

  • Yim, Sung-Sam;Song, Yun-Min
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.317-327
    • /
    • 2012
  • The average specific cake resistance, the most important indicator for cake filtration and solid-liquid separation, is measured by filtration experiment. But the exact value is difficult to measure because of the other influences such as sedimentation during filtration. This study, a little more stable method named filtration-permeation is proposed for measuring average specific cake resistance. The filtration-permeation is composed of permeation of particle eliminated water through pre-formed cake by filtration. Using 1 wt% calcium carbonate suspension, the filtration-permeation experiments were performed for 8 kinds of filter media at the conditions of 0.5 atm and 0.2 atm, 1 and 3 sheets of filter media. At each specific condition, three to five times filtration-permeation were accomplished. As a result, stable permeation speed is measured. According to this experimental result, the characteristics of permeation and the effect of sedimentation are analyzed with Ruth's equation. The one way analysis of variance (one way ANOVA) is applied to the average specific cake resistances of filtration and permeation obtained with the selected three kinds of filter media. The average specific cake resistances between 0.5 atm and 0.2 atm by filtration do not distinguished, but those by permeation is perfectly distinguished. The experimental results during permeation have a very narrow distribution than that measured during filtration. The analysis of filtration experiments, it was verified that the resistance of filter medium by traditional method is of no significance. Finally, the migration of small particles through the medium composed of fiber glass at low pressure was studied.

A Study about Applicability of Treatment for Water Treatment Residual Sludge Using Crossflow Tubular Membrane System (정수장 배출수 처리를 위한 Crossflow 관형막 여과 공정의 운전 적용에 관한 연구)

  • Kim, Young Hoon;Kim, Kwan Yeop;Kim, Ji Hoon;Lee, Yong Soo;Lee, Eui Jong;Eom, Jung Yeol;Kim, Hyung Soo;Hwang, Sun Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.4
    • /
    • pp.499-505
    • /
    • 2009
  • Many other countries have investigated the residual sludge treatment process to save the existing water resource and produce the high suspended solid concentration sludge. There are various methods for concentrating residual sludge, but the membrane system has received the most interest for its efficiency. The objective of this study was to evaluate the application of membrane filtration system for the residual sludge treatment. The experiment equipment was composed of Lab scale Crossflow tubular membrane filtration system. Generally, crossflow operation mode demands high electric cost mainly for the pump energy. So to cut off electric cost, very low Crossflow velocity was used in this experiment. Results confirmed that suspended solid concentration of residual sludge could be concentrated to 57,000mg/L in low Crossflow velocity tubular membrane system,. This concentration can be directly injected into the dehydrator. Based on the results, we know that the Crossflow tubular membrane system should be replaced conventional residual sludge treatment system.

A study on the headloss of filter media for treatment of Road Runoff (도로노면 유출수 처리를 위한 여과에서의 여재별 손실수두 특성)

  • Choi, Weon-Suk;Song, Changsoo;Kim, Seog-ku
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.6
    • /
    • pp.697-704
    • /
    • 2008
  • Stormwater runoff from urban road area as non-point source has a tendency of including lots of pollutants at initial rain period. Recently, there are several cases of having installed treatment facilities for reducing pollution discharge from the impervious cover in urban area to prevent watershed environment from getting worse. The filtration type among non-point source treatment systems has been known as one of the most efficient system for treatment of non-point source pollutants. Therefore, various kinds of filter media such as expanded polypropylene(EPP), granular activated carbon, zeolite, perlite, illite, sand, gravel has been developed. This study was conducted to verify performance and hydraulic characteristics of filter media as measures for non-point source. The experiment was carried out to evaluate applicability and variation of 4 kind of most popular filter media(EPP, GAC, Zeolite, Perlite) in headloss with elapsed time and influent flow rate and to obtain data base that could be used to establish management plan for road runoff treatment. In experiment by tap water, it showed that EPP and perlite those are floatable materials showed stable operating performance and lower headloss than the others.

Optimization of Coagulation and Media Filtration Process for Low Turbidity Seawater (저탁도 해수원수 특성에 적합한 응집 - 여과 공정의 최적화)

  • Son, Dong-Min;Jo, Myeong-Heum;Kim, Jeong-Sook;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.251-257
    • /
    • 2014
  • This research is focused on coagulation and sand filtration process as a pretreatment of RO seawater desalination. RO systems require sufficient and reliable pretreatment process to produce superior quality of RO feedwater that can mitigate RO membrane fouling. This experiment was conducted to investigate the effectiveness of coagulation and filtration process under various experimental conditions including different coagulant dose, flocculation mixing intensity and time, turbidity, and filtration rate. The experimental results showed that the optimum pretreatment conditions resulting in lower SDI value suitable for RO feedwater were coagulation pH 6.5, raw water turbidity greater than 4 NTU, and media bed depth greater than 550 mm. However, flocculation mixing intensity, coagulant dose, and filtration rate relatively affected little on the filtration efficiency.

Treatment Characteristics of Rapid filtration Process treating Secondary Clarifier Effluent for Wastewater Reuse (처리수 재이용을 위한 최종침전지 유출수의 급속여과공정 처리특성)

  • Han, Dong-U
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.2
    • /
    • pp.213-220
    • /
    • 2002
  • This reserch was focused upon experimental study for wastewater reuse and conducted to evaluate optimum operating conditions of rapid filtration process such as filter flow rate, filtration time and backwashing condition for reuse of secondary-treated effluent using the pilot plant installed in real wastewater treatment plant. Also, the experiment on treatment char-acteristics of coagulant-added activated sludge process was performed to compare with activated sludge succeeded to rapid filtration. As the filtration velocity was 100m/day, the filtration time of the rapid filter connected with activated sludge system was revealed to 40 hours. Backwashing of filter was conducted by water wash and air scour. The optimum backwashing time and backwash flow rate were 10min and 10LPM, respectively. The quantity of backwashing water of the rapid filter was about 2% of total treated water.

Pilot Scale Assessment of DOC and THMs Removal in Conventional Water Treatment System

  • Lee, Choong-Dae;Lee, Yoon-Jin
    • Journal of Environmental Science International
    • /
    • v.15 no.9
    • /
    • pp.829-834
    • /
    • 2006
  • This research aims to investigate the behavior of organic matter that causes bacterial re-growth and the formation of disinfectant by-products such as THM in water treatment, and to optimize conditions for a more efficient and conventional water facility. THM removed 51 % and 12 % through coagulation/sedimentation and filtration using a selected conventional system. In this experiment, the removal ratio of DOC was highest at 68 % when the Gt value was 42,000 and lowest at 41 % when the Gt value was 30,000. 77-84 % of total DOC was removed during coagulation/sedimentation, and 15-23 % was removed during filtration. When Gt values were between 30,000 and 66,000, over 50 % of high molecular matter above 10 K during coagulation/sedimentation was removed. Turbidity removed 98 % when the G1 value was 66,000. As the Gt value increased, the turbidity removal ratio increased. Turbidity removed over 20 % during the filtration process.