• 제목/요약/키워드: Filtration experiment

검색결과 202건 처리시간 0.031초

역세 배출수 처리를 위한 관형막의 전량여과 운전 적용에 대한 연구 (A Study about Applicability of Treatment for Backwash Water Using Tubular Membrane System with Dead-End Operation Mode)

  • 엄정열;김관엽;김영훈;송준섭;김형수;한명애;양형석
    • 상하수도학회지
    • /
    • 제22권4호
    • /
    • pp.437-444
    • /
    • 2008
  • Many other countries have investigated the new backwash water treatment process to save the existing water resource. There are various methods for reusing backwash water, but the membrane system has received the most interest for its efficiency. The objective of this study was to certify the application of membrane filtration system for the backwash water treatment. The experiment equipment was composed of Lab scale tubular membrane filtration system. Generally, cross-flow operation mode is used in the tubular membrane system but cross-flow operation mode demands high electric cost mainly for the pump energy. So to cut off electric cost, dead-end operation mode was used in this experiment. Filtration and bleed operation cycle was used in this membrane system. Backwash water was concentrated during the filtration process and when backwash water reached our target suspended solid concentration, it was discharged from this system. For efficient operation of filtration and bleed, mathematical matrix was drawn up and with this matrix we could simulate various sets of filtration and bleed time.

단일 채널 DPF의 PM 포집 모델링 및 모델 파라미터의 민감도 해석 (Rigorous Modeling of Single Channel DPF Filtration and Sensitivity Analysis of Important Model Parameters)

  • 정승채;박종선;윤웅섭
    • 한국자동차공학회논문집
    • /
    • 제14권6호
    • /
    • pp.127-136
    • /
    • 2006
  • Prediction of diesel particulate filtration is typically made by virtue of modeling of particulate matter(PM) collection. The model is closed with filtration parameters reflecting all small scale phenomena associated with PM trapping, and these parameters are to be traced back by inversely analyzing large-scale empirical data-the pressure drop histories. Included are soot cake permeability, soot cake density, soot density in the porous filter wall, and percolation constant. In the present study, a series of single channel DPF experiment is conducted, pressure histories are inversely analyzed, and the essential filtration parameters are deducted by DPF filtration model formulated with non-linear description of soot cake regression. Sensitivity analyses of model parameters are also made. Results showed that filtration transients are significantly altered by the extent of percolation constant, and the soot density in the porous filter wall is controlling the filtration qualities in deep-bed filtration regime. In addition, effect of soot particle size on filtration quality is distinct in a period of soot cake regime.

Motion behavior research of liquid micro-particles filtration at various locations in a rotational flow field

  • Yan, Yan;Lin, Yuanzai;Cheng, Jie;Ni, Zhonghua
    • Structural Engineering and Mechanics
    • /
    • 제62권2호
    • /
    • pp.163-170
    • /
    • 2017
  • This study presents a particle-wall filtration model for predicting the particle motion behavior in a typical rotational flow field-filtration in blower system of cooker hood. Based on computational fluid dynamics model, air flow and particles has been simulated by Lagrangian-particle/ Eulerian-gas approaches and get verified by experiment data from a manufacturer. Airflow volume, particle diameter and local structure, which are related to the particle filtration has been studied. Results indicates that: (1) there exists an optimal airflow volume of $1243m^3/h$ related to the most appropriate filtration rate; (2) Diameter of particle is the significant property related to the filtration rate. Big size particles can represent the filtration performance of blower; (3) More than 86% grease particles are caught by impeller blades firstly, and then splashed onto the corresponding location of worm box internal wall. These results would help to study the micro-particle motion behavior and evaluate the filtration rate and structure design of blower.

Effect of Buffer Composition, Sephadex Grade and Column Size on Filtration Based Quality Improvement of Semen from Murrah Buffalo Bull

  • Maurya, V.P.;Tuli, R.K.;Goyal, R.L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제16권2호
    • /
    • pp.165-171
    • /
    • 2003
  • Sixty semen ejaculates collected at weekly interval from four Murrah Buffalo bulls over a period of seven months (Nov.1999 to May 2000) were used in the present study. Three buffer medium (sodium citrate, TES and Tris) were used for soaking of sephadex. Three grades of sephadex (G-15,G-100, and G-200) were used for preparation of columns. Columns of three different height (one, two and three cm) were used for separation of semen. Twenty semen ejaculates were used in each project. In the first experiment each semen ejaculates was divided into four parts. One part was kept as control and other three parts were passed thought one cm column of sephadex G-15 prepared in three different buffers. There was significant (p<0.05) increase in percent progressive sperm motility and percent live spermatozoa and decrease in percent abnormal spermatozoa and percent spermatozoa with damaged acrosome as well as sperm numbers after filtration through all the three columns. Sperm quality obtained in the filtrate of column prepared in Tris buffer was better in comparison to other two buffers. So the Tris buffer was used in the second trial. Twenty semen ejaculates were used in this experiment. Each semen ejaculate was divided into four parts. One part was kept as control (non-filtered) and other three parts were passed through columns of different grade of sephadex (G-15, G-100 and G-200). Progressive sperm motility and live sperm percentage improved significantly while decline in percent abnormal spermatozoa and percent spermatozoa with damaged acrosome and sperm concentration was observed after filtration through all the columns as compared to control (non-filtered) semen. Since post filtration quality of semen was better in the sephadex G-100 column, therefore it was selected for the next experiment. In third experiment, Tris buffer and sephadex G-100 were used for preparing columns of different height (one, two and three cm) and twenty semen ejaculates were filtered. The quality characteristics of semen (percent progressive sperm motility, percent live spermatozoa and sperm concentration) after filtration through one cm column were significantly (p<0.05) higher than after filtration through columns of two and three cm height. However non -significant (p>0.05) difference due to height of columns was observed for percent abnormal and percent damaged acrosome but 1 cm column comparatively gave better result than of 2 and 3 cm column height.

강변여과에서 파일럿규모 수평집수관의 수두분포 연구 (A Study on the Distribution of Hydraulic Head Along the Lateral in a Pilot-Scale Riverbank Filtration)

  • 정재민;박재영;이종진;김용운;김승현
    • 대한환경공학회지
    • /
    • 제35권5호
    • /
    • pp.334-339
    • /
    • 2013
  • 강변여과용 수평집수관을 모사하는 파일럿 규모의 모래통 실험을 수행하였으며, 다양한 출구유속에 대한 수평집수관에서의 수두분포를 구하였다. Kim이 수행한 실험실 규모의 수평집수관에서의 손실수두에 Kim이 개발한 이론 즉, 작은 규모의 수평집수관에서의 손실수두로부터 큰 집수관의 손실수두를 계산하는 방법을 적용하여 본 연구의 관측치와 비교함으로써 Kim의 이론이 타당함을 알 수 있었다. 또한, 이들의 이론을 적용하여 본 연구에서의 관측치로부터 실규모 집수관에서의 수두분포를 구하는 방안을 예를 들어 설명함으로써 강변여과의 수평집수관 설계방법을 제시하였다.

여과-투과 방법의 이론적, 실험적 응용에 대한 연구 (Study on the Theoretical and Experimental Application of Filtration-Permeation Method)

  • 송연민;임성삼
    • 대한환경공학회지
    • /
    • 제30권2호
    • /
    • pp.161-167
    • /
    • 2008
  • 본 연구에서는 새로운 여과-투과(filtration-permeation) 실험 방법을 사용하여 여과실험에 영향을 미치는 인자 중 침전에 대한 영향을 입자현탁액과 플럭현탁액에 대해 각각 수행하였다. 그 결과 여과실험으로는 정확한 평균 비저항값을 예측할 수 없었으나, 투과실험으로 정확한 평균 비저항값을 측정할 수 있었다. 투과기간을 연장하였을 때 입자현탁액에서 형성된 케이크에서는 투과속도에 별다른 영향이 없었으나 플럭현탁액의 경우는 응집제의 쓸려나감 현상을 보였다. 또한 여과-투과 실험을 사용하여 투과시에 단계적으로 압력을 증가시킴으로써 단 한번의 실험에 의해 케이크의 압축성이 측정되어 질 수 있음을 보였으며, 이 방법을 응용하여 평균 비저항값이 큰 활성슬러지의 긴 여과시간을 짧게 줄여 측정하는 새로운 방법을 제안하였다.

강변여과에서 여과거리에 따른 페놀, 1,4-다이옥산 그리고 다이아지논의 거동에 관한 실험연구 (An Experimental Study on the Behavior of Phenol, 1,4-dioxane and Diazinon along the Travel Distance in Riverbank Filtration)

  • 최홍규;정일화;정관수;이영득;김승현
    • 대한환경공학회지
    • /
    • 제35권6호
    • /
    • pp.436-441
    • /
    • 2013
  • 복류수와 천변여과지 그리고 점차 여과거리가 짧아지고 있는 우리나라의 강변/하상여과 등이 가지는 미량오염물에 대한 저항능력을 평가하기 위하여 5 m 길이의 모래칼럼을 이용한 실험을 수행하였다. 실험결과 우리나라 하상의 토양은 유기물 함량이 상당하여 염소이온의 토양표면 흡착이 비교적 활발함 알 수 있었다. 페놀은 칼럼의 여과수에서 검출되지 않았고, 1,4-다이옥산과 다이아지논은 하상토양과 흡착반응을 일으키면서 이동하며, 2.5 m의 이동과정에서 1,4-다이옥산의 첨두농도는 유입농도의 약 40%로 그 농도가 감소하였고, 다이아지논의 첨두농도는 약 60%로 감소하는 것으로 나타났다. 실규모 설비에서는 여과거리가 5 m 보다 더 길기 때문에 첨두농도의 감소효과는 상당히 클 것으로 기대되었다.

여과형 시설에 적용되는 여재의 처리효율 영향인자를 고려한 실증화 평가 (Verification of the Filter Media Applied to Filter Type Facility Considering the Treatment Efficiency Factor)

  • 김태윤;이준배;이동우;신현석;김현철;권순철
    • 한국물환경학회지
    • /
    • 제33권5호
    • /
    • pp.572-579
    • /
    • 2017
  • Increased impervious surface caused by rapid urbanization serves to produce the discharge of non-point source pollutants such as total suspended solid (TSS). There exist various methods of removing TSS, including a filtration process using granular media (a well-known method to be practically used after the consideration of removal efficiency, clogging, and backwashing efficiency). To determine the TSS removal capability of the filter, we initially performed lab-scale experiments which assessed flow rates, influent concentrations, permeability co-efficients, the particular shapes of suspended solids and potential clogging, and also evaluated TSS removal efficiency when applied to filtration facility in a pilot-scale. In low filtration flux condition, the removal efficiency of suspended solids was more than 95 %, while decreased to 83% in high filtration flux. Regarding the clogging aspect of the experiment, total cumulative solids were loaded up to $19.15kg/m^2$, and TSS removal efficiency was noted to commence to decrease when the loaded solids exceeded $9.0kg/m^2$. It was also noted, however, that superior efficiency was maintained for six hours. In addition, for pilot-scale experiment, the removal efficiency was still high enough (83.4 %) for the solid concentration of 140 ~ 343 mg SS/L and after backwashing, head loss was recovered to 92 ~ 95 % during two hour filtration. With these results, It was confirmed that lifetime of the filter applied to the test was prolonged due to the high treatment efficiency and good backwashing efficiency for the cumulative solids load.