• Title/Summary/Keyword: Filtration System

Search Result 707, Processing Time 0.027 seconds

Development of Screening Technology for Marine Waste Disposal (수산폐기물 전처리 용 스크린기술 개발)

  • Moon, Serng-Bae;Jun, Seung-Hwan;Jin, Gang-Gyoo
    • Journal of Navigation and Port Research
    • /
    • v.33 no.1
    • /
    • pp.57-63
    • /
    • 2009
  • In order to effectively isolate the marine wastes with an effluent standard, the pretreatment process is required to isolate solid materials from the liquid-solid mixed wastes. The more effective the pretreatment becomes, the more processing capacity of posttreatment will be improved and process facilities will be downsized. In this paper, we suggested the vibrating reverse-slant screen, investigated the optimal vibration frequency and vibrator installation angle for the separation of the liquid solid mixed wastes. Several experiments for separation efficiency were conducted under the condition of various vibration frequency($35{\sim}60Hz$, 5Hz interval) and vibrator angle($0^{\circ}$, $30^{\circ}$, $45^{\circ}$, $90^{\circ}$) considering the crack of screen. The screen inclination angle is set up the gradient as $3^{\circ}{\sim}5^{\circ}$ through the preliminary experiments. Also, we made two types of screen(respectively rectangle and square screen). The separation device has shown the optimum efficiency at vibrator angle $0^{\circ}$ and vibration frequency 60Hz, and has no relation with the shape of screen. And the proposed technology is verified by comparing with quantity of suspended solids before and after filtration.

Image and Exposure Dose in Accordance with Radiation Quality on Plain Chest Radiography (흉부촬영(胸部撮影)에서 증감지(增感紙)-필름계의 선질변화(線質變化)에 따른 감도(感度)와 화질에 관(關)한 연구(硏究))

  • Kim, Jung-Min;Kim, Dong-Huan;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakura, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.

  • PDF

Determination of methamphetamine, 4-hydroxymethamphetamine, amphetamine and 4-hydroxyamphetamine in urine using dilute-and-shoot liquid chromatography-tandem mass spectrometry (시료 희석 주입 LC-MS/MS를 이용한 소변 중 메스암페타민, 4-하이드록시메스암페타민, 암페타민 및 4-하이드록시암페타민 동시 분석)

  • Heo, Bo-Reum;Kwon, NamHee;Kim, Jin Young
    • Analytical Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.161-170
    • /
    • 2018
  • The epidemic of disorders associated with synthetic stimulants, such as methamphetamine (MA) and amphetamine (AP), is a health, social, legal, and financial problem. Owing to the high potential of their abuse and addiction, reliable analytical methods are required to detect and identify MA, AP, and their metabolites in biological samples. Thus, a dilute-and-shoot liquid chromatography-tandem mass spectrophotometry (LC-MS/MS) was developed for simultaneous determination of MA, 4-hydroxymethamphetamine (4HMA), AP, and 4-hydroxyamphetamine (4HA) in urine. Urine sample ($100{\mu}L$) was mixed with $50{\mu}L$ of mobile phase consisting of 0.4 % formic acid and methanol and $50{\mu}L$ of working internal-standard solution. Aliquots of $8{\mu}L$ diluted urine was injected into the LC-MS/MS system. For all analytes, chromatographic separation was performed using a C18 reversed-phase column with gradient elution and a total run time of 5 min. The identification and quantification were performed by multiple reaction monitoring (MRM). Linear least-squares regression was conducted to generate a calibration curve, with $1/x^2$ as the weighting factor. The linear ranges were 2.0-200, 1.0-800, and 10-2500 ng/mL for 4HA and 4HMA, AP, and MA, respectively. The inter- and intraday precisions were within 6.6 %, whereas the inter- and intraday accuracies ranged from -14.9 to 11.3 %. The low limits of quantification were 2.0 ng/mL (4HA and 4HMA), 1.0 ng/mL (AP), and 10 ng/mL (MA). The proposed method exhibited satisfactory selectivity, dilution integrity, matrix effect, and stability, which are required for validation. Moreover, the purification efficiency of high-speed centrifugation was clearly higher than 6-15 % for QC samples (n=5), which was higher than that of the membrane-filtration method. The applicability of the proposed method was tested by forensic analysis of urine samples from drug abusers.

Recycling of Acidic Etching Waste Solution Containing Heavy Metals by Nanofiltration (I): Evaluation of Acid Stability of Commercial Nanofiltration Membranes (나노여과에 의한 중금속 함유 산성 폐에칭액의 재생(I): 상용 나노여과 막의 산 안정성 평가)

  • Youm, Kyung-Ho;Shin, Hwa-Sup;Jin, Cheon-Deok
    • Membrane Journal
    • /
    • v.19 no.4
    • /
    • pp.317-323
    • /
    • 2009
  • In this study the nanofiltration (NF) membrane treatment of a nitric acid waste solutions containing $Pb^{+2}$ heavy metal ion discharging from the etching processes of an electronics and semiconductors industry has been studied for the purpose of recycling of nitric acid etching solutions. Three kinds of NF membranes (General Electric Co. Duraslick NF-4040 membrane, Dow Co. Filmtec LP-4040 membrane and Koch Co. SelRO MPS-34 4040 membrane) were tested for their separation efficiency (total rejection) of $Pb^{+2}$ ion and membrane stability in nitric acid solution. NF experiments were carried out with a dead-end membrane filtration laboratory system. The membrane permeate flux was increased with the increasing storage time in nitric acid solution and lowering pH of acid solution because of the enhancing of NF membrane damage by nitric acid. The membrane stability in nitric acid solution was more superior in the order of Filmtec LP-4040 < Duraslick NF-4040 < SelRO MPS-34 4040 membrane. The total rejection of Pb+2 ion was decreased with the increasing storage time in nitric acid solution and lowering the pH of acid solution. The total rejection of $Pb^{+2}$ ion after 4 months NF treatment was decreased from 95% initial value to 20% in the case of Duraslick NF-4040 membrane, from 85% initial value to 65% in the case of SelRO MPS-34 4040 membrane and from 90% initial value to 10% in the case of Filmtec LP-4040 membrane. These results showed that SelRO MPS-34 4040 NF membrane was more suitable for the treatment of an acidic etching waste solutions containing heavy metal ions.

Optimal Conditions for As(III) Removal by Filtration System Packed with Different Ratio of Iron-Coated Sand and Manganese-Coated Sand (철 및 망간코팅사 충전비를 달리한 여과시스템에서 3가 비소 제거의 최적 조건)

  • Chang, Yoon-Young;Kim, Kwang-Seob;Song, Ki-Hoon;Yang, Jae-Kyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.11
    • /
    • pp.1186-1191
    • /
    • 2006
  • Removal efficiency of As(III) through oxidation and adsorption in column reactors was investigated at different ratios of manganese-coated sand(MCS) and iron-coated sand(ICS) : MCS-alone, ICS-alone and both of ICS and MCS. The breakthrough of arsenic immediately occurred from a column reactor with MCS-alone. However, most of the arsenic present in the effluent was identified as As(V) due to the oxidation of As(III) by MCS. While five-times delayed breakthrough of arsenic was observed from a column reactor with ICS-alone. At a complete breakthrough of arsenic, the removed As(III) was 36.1 mg with 1 kg ICS. To find an optimum ratio of ICS and MCS in the column packed with both ICS and MCS, the removal efficiency of As(III) was investigated at three different ratios of ICS/MCS with a fixed amount of ICS. The breakthrough time of arsenic was quite similar in the different ratios ICS/MCS. However, much slower breakthrough of arsenic was observed as the ratio of ICS/MCS decreased. As the ratio of ICS/MCS decreased the concentration of As(III) in the effluent decreased and then showed below 50 ppb at an equal amount of ICS and MCS, suggesting more efficient oxidation of As(III) by greater amount of MCS. When a complete breakthrough of arsenic occurred, the removed total arsenic with an equal amount of ICS and MCS was 68.5 mg with 1 kg of filter material.

A Study on Location Selection for Rainwater Circulation System Elements at a City Level - Focusing on the Application of the Environmental and Ecological Plan of a Development - (도시차원의 빗물순환체계 요소별 입지선정에 관한 연구 - 개발예정지역의 환경생태계획 적용방안을 중심으로 -)

  • Kim, Hyo-Min;Kim, Kwi-Gon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.3
    • /
    • pp.1-11
    • /
    • 2012
  • This study focused on establishing a natural rainwater circulation system using rainwater meant for relatively large urban development projects such as a new town development. In particular, when the location selection techniques for individual elements of a natural rainwater circulation system are developed for the integrated rainwater management, changes in hydrological environment will be minimized and the natural water circulation would be restored to realize the low impact development (LID). In that case, not only the excess will be reduced but water space and green areas in a city would also increase to improve the urban sustainability. First of all, there were five elements selected for the location selection of a rainwater circulation system intended for the integrated rainwater management: rainwater collection, infiltration, filtration, retention and movement spaces. After generating these items, the location selection items and criteria were defined for each of the five elements. For a technique to apply the generated evaluation items and criteria, a grid cell analysis was conducted based m the suitability index theory, and thematic maps were overlapped through suitability assessment of each element and graded based on the suitability index. The priority areas were identified for each element. The developed technique was applied to a site where Gim-cheon Innovation City development is planned to review its feasibility and limitations. The combined score of the overlapped map for each element was separated into five levels: very low, low, moderate, high and very high. Finally, it was concluded that creating a rainwater circulation system conceptual map m the current land use plan based on the outcome of the application would be useful in building a water circulation system at the de1ailed space planning stage after environmental and ecological planning. Furthermore, we use the results of this study as a means for environment-friendly urban planning for sustainable urban development.

A Study on the Reduction of Kidney Uptake of 18F-FDG due to the Water Intake at the Time of Additional Examination in the PET/CT scan (PET/CT 검사에서 추가 검사 시 수분섭취에 따른 18F-FDG의 신장 섭취 감소에 대한 고찰)

  • Lee, Yi Lang;Kim, Sang Gyu;Ham, Jun Chul;Nam-Koong, Hyuk;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.47-51
    • /
    • 2016
  • Purpose By ingestion of 18F-FDG of kidney of PET/CT during the inspection, if additional examination is required, depending on whether you want to water intake, we want to confirm a change in the rate of decrease of F-18 FDG of the kidney. Materials and Methods The 80 patients without kidney disease were performed PET/CT examination. Device was analyzed after setting the kidney to a three-dimensional region of interest. In patients require additional examination, and inspection after 30 minutes, a PET/CT torso examination after the water of the 500 cc ingested at a time. After the addition of both water intake group and no hydration group of kidney of SUV, it was compared with PET/CT torso scan. Results High and low of the kidney SUV did not show a significant difference in the rate of decrease. Reduction rates of background (BKG) of additional examination was 2.8% and reduction rates of SUV was 49.7% (Hydration) : -6.8% (No hydration), so did show a significant difference. In the image blind test, the average point score of hydration and no hydration was 34.25 : 17.25. Conclusion An undercurrent of 18F-FDG in the kidney at the time of torso examination, it was confirmed that the reduction rate after the addition of water intake is high. It is considered that can be expected to improve the quality of an image due to a decrease in elongation through the kidneys examination with additional fluid intake as needed intake.

  • PDF

Influence of Yohimbine on the Central Dopaminergic Regulation of Renal Function (신장기능의 중추 Dopamine성 조절에 미치는 Yohimbine의 영향)

  • Kook, Young-Johng;Kim, Kyung-Keun;Cho, Kang-Seon;Min, Byung-Kap
    • The Korean Journal of Pharmacology
    • /
    • v.22 no.2
    • /
    • pp.79-87
    • /
    • 1986
  • Recently it has been shown that central dopaminergic system regulates the renal function and that intracerebroventricularly (icv) administered dopamine (DA) produces antidiuresis and antinaturiuresis, resembling icv norepinephrine, and evidence has been accumulated which would suggest the involvement of adrenergic system in the DA effects. It was attempted therefore in this study to see whether the DA effect is influenced by pretreatment of yohimbine which is known as a specific ${\alpha}_2-adrenoceptor$ antagonist. Yohimbine produced, when given icv in doses of $100\;{\mu}g/kg$, marked antidiuresis and antinatriuresis along with decreases in renal perfusion and glomerular filtration. DA, in doses of $15\;{\mu}g/kg$, also produced antidiuresis and antinaturiuresis. However, after yohimbine-pretreatment DA $15\;{\mu}g/kg$ improved renal hemodynamics, and electrolyte excretion and urine flow rate transiently increased. With $150\;{\mu}g/kg$ DA, the antidiuresis was more marked in the control group. But the yohimbine-pretreated animals responded with marked diuresis and natriuresis, sodium excretion increasing more than three-fold, which lasted for 20 minutes. $K^+-excretion$, osmolar clearance as well as free-water reabsorption increased. Renal hemodynamics improved partly. Apomorphine, a DA agonist, when given icv in doses of $150\;{\mu}g/kg$, produced diuresis and naturiuresis, concomitant with increased renal hemodynamics. Yohimbine-pretreatment however did not abolish the apomorphine-induced diuresis and naturiuresis. Antidiuresis and antinatriuresis elicited by norepinephrine, $10\;{\mu}g/kg$, was not affected by yohimbine-pretreatment. These results indicate that the renal effects of icv DA is not so simple as those of norepinephrine, and the diuretic natriuretic cffect which had been masked by the hemodynamic effect becomes manifest only when the decreases in hemodynamics were removed by the pretreatment of yohimbine. It was further suggested that those DA receptors which mediate the natriuretic response to icv DA is not affected by yohimbine, whereas those receptors involved in the decrease in renal hemodvnamics are blocked by yohimbine. And the possibility of involvement of adrcnergic system in the DA action is not substantiated.

  • PDF

A Study on the Tendency of Dose value According to Dose calibrator Measurement Depth and Volume (Dose calibrator 측정 깊이와 용량의 변화에 따른 선량 값의 성향에 대한 고찰)

  • Kim, Jin Gu;Ham, Jun Cheol;Oh, Shin Hyun;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.20-26
    • /
    • 2020
  • Purpose It is intended to figure out the errors derived from changes in depth and volume when measuring the Standard source and 99mTc-pertechnetate by using a Dose calibrator. Then recommend appropriate measurement depth and volume. Materials and Methods As a Dose calibrator, CRC-15βeta and CRC-15R (Capintec, New Jersey, USA) was used, and the measurement sources were 57Co, 133Ba, 137Cs and 99mTc-pertechnetate was also adopted due to its high frequency of use. The Standard source was respectively measured the changes according to its depth without changing the volume, in a range of 0 cm to 15 cm from the bottom of the ion chamber. 99mTc-pertechnetate was measured at each depth by changing the volume with 0.1 mL, 0.3 mL, 0.5 mL, 0.7 mL and 0.9 mL Respectively. And the depth range was from 0 cm to 15 cm at the bottom of the ion chamber. Results In the case of Standard source 57Co, 133Ba, 137Cs and 99mTc-pertechnetate, there were significant differences according to the measurement depth(p<0.05). 99mTc-pertechnetate has a negative correlation coefficient according to the depth, and the error of the measured value was negligible at a depth from 0 cm to 7 cm at 0.3 mL and 0.5 mL, and the range of error increased as the volume increased. Conclusion In clinical practice, it is sometimes installed differently than the Standard depth recommended by the equipment company. If it's measured at the recommended depth and volume, it could be thought that unnecessary exposure of the operator and the patient will be reduced, and more accurate radiation exams will be possible in quantitative analysis.

A Studyon the Movment of Ground Water of Banayweol Formation (반야월층(半夜月層)의 지하수운동(地下水運動)에 관(關)한 연구(硏究))

  • Kim, Yong Ki
    • Economic and Environmental Geology
    • /
    • v.9 no.4
    • /
    • pp.225-240
    • /
    • 1976
  • This study deals with the flow of bed rock ground water of Banyaweol Formation, which is presently cleared up as a laminar flow. The result obtained may be summarized as the following. 1) The Banyaweol Formation consists mainly of thin-bedded, green to blackish green shale, mudstone, and marl. The marl and mudstone alternatively occur with shale. The marl and mudstone form a aquifer of Banyaweol Formation. In this study, a group of aquifer is in convenience named as a aquifer zone. The aquifer occurs in lenticular form. The aquifer seems to be a type of artesian aquifer because it is covered with aquicludes, but it actually forms a unconfined aquifer because its piezometric surface stays under the lower aquiclude. The lowering of piezometric level is formed because of leakage of the ground water to the lower aquifer undersaturated. 2) The coefficient of permeability of Banyaweol Formation's ground water body (K) is derived by using Dupuit's equation as the following ${\log}K=\frac{CK^2-dK+f}{aK-b}\;\(M=1.365(2H-s)s\\M={\log}1.956s{\sqrt{H}}r\)$ here, $$a=\sum_{1}M_iG_i$$ $$b={\frac{1}{2}log{\sum_{i}}Q_i{^2}$$ $$c=2{\sum_{i}}M_i{^2}$$ $$d=loge{\sum_{i}}M_{i}Q_{i}+2{{\sum_{i}}N_{i}Q_{i}$$ $$f=loge{\sum_{i}}Q_i{^2}N_i$$ If the measured values substituted for the above equation, the coefficient of permeability of the aquifer is 4.1m/day. The coefficient of storge of the aquifer is $2.8{\times}10^{-4}$ if the measured values substituted for Theis's equation. Using the above constants, the filtration velocity of the aquifer is $2.1{\times}1O^{-1}m/day$and the daily flow quantity of the ground water is $847.38m^{3}/day$. 3) In order to understand the time necessary for a circulation of ground water body, the contents of tritum contained in the ground water are measured as 2.3 T.U. at the Korea Atomic Energy Research Institute. Before 1952, the average concentration of tritium per year in groundwater was reported as 10T. u., taking it as the standard, the groundwater of the present study 26.25 years old. Therofore, the groundwater of the Banyaweol Formation is judged as an relatively old groundwater. It is characteristic that the ground water of Banyawol Formation is laminar flow as well as unconfined aquifer and ground water flow of relatively long time. 4) The nature, means of flow, and circulation of Banyaweol Formation's ground water body make it possible set up this ground water body as a ground water system.

  • PDF