• Title/Summary/Keyword: Filtration Efficiency

Search Result 514, Processing Time 0.027 seconds

A laboratory study on synthetic fiber filter for further treatment of turbid stormwater from construction sites

  • Yuan, Qingke;Kim, Youngchul
    • Membrane and Water Treatment
    • /
    • 제10권2호
    • /
    • pp.105-112
    • /
    • 2019
  • On the purpose of conform the more stringent government regulation for turbid stormwater from construction sites, the feasibility and availability of synthetic fiber placing after the conventional protection barrier were tested in this study. Initially, comparative work on the filtering performance of fiber media and conventional gravel filter was carried out, 27% higher filtration capacity was obtained under the similar operational conditions. The filter efficiency was about 20 to 52% with a varying filter depth of 5 to 15cm, presuming at extreme storm flow conditions (800-1500 m/day of filtration rates). Fiber filter was found to have a similar filtration prosperity as grain media; namely, the separation efficiency is directly and inversely proportional to filter depth and rate, respectively. The effects of filter aid (polyaluminium chloride) on filter performance was also investigated, it greatly affected the turbidity reduction at the dosage of 2 mg/L. At the time of breakthrough, a simple filter washing was carried out, herein, the solid recovery achieved over than 88% and greatly determined by operational parameters. Based on the operational data, the empirical models aimed for predicting filtration efficiency were established, which can effectively determine the required filter depth and filtration area in field.

국내 출시 마스크의 바이오에어로졸 여과효율 평가 (Filtration Efficiencies of Commercial Face Masks in Korea for Biological Aerosols)

  • 최수은;최도선;장성재;박성준;윤충식;이기영;고광표;이정훈
    • 한국환경보건학회지
    • /
    • 제48권2호
    • /
    • pp.116-122
    • /
    • 2022
  • Background: The recent COVID-19 pandemic is one of the worst disease outbreaks of the 21th century. Due to a lack of reliable antiviral therapeutics, wearing face masks is recommended to prevent airborne infection originating from virus-contaminated bioaerosols. Objectives: The aim of this study was to evaluate the filtration efficiencies of face masks that are commercially available in South Korea for a biological aerosol of Staphylococcus aureus (S. aureus) and murine coronavirus, a well-known surrogate for human coronaviruses. Methods: We collected six different kinds of commercial masks: two Korea Filter (KF)94 (KF94-1, KF94-2) masks, one surgical (Surgical-1) mask, one anti-droplet (KF-AD-1) mask, and two dust (Dust-1, Dust-2) face masks. S. aureus (ATCC 6538), a well-performing test bacteria and murine coronavirus (ATCC VR-764) were prepared under a suitable culture condition. Then, a mask biological filtration tester was used to examine the microbial filtration efficiencies of masks. Test microorganisms were quantitatively measured via cultivation methods and microbial filtration efficiencies were calculated appropriately. Results: All face masks showed over 99.6% filtration efficiency for S. aureus or murine coronavirus. There were no significant differences among the bacterial filtration efficiencies of the face masks. KF94-1 (99.97±0.08%) and Dust-1 mask (99.97±0.07%) showed the highest (over 99.9%) filtration efficiency for murine coronavirus. KF94-1 or Dust-1 masks showed a significant virus filtration efficiency compared to Surgical-1 mask (p<0.05; Mann-Whitney U test). Conclusions: All the commercially available face masks used in this study can filter S. aureus or murine coronavirus in bioaerosols efficiently, regardless of the mask type. Therefore, our results suggest that wearing a certified face mask is a reliable means to prevent the transmission of infectious airborne diseases via biological aerosols.

탄소섬유 이오나이저를 적용한 활성탄소섬유 필터의 바이오에어로졸 항균 및 집진 성능평가 (Inactivation and Filtration of Bioaerosols Using Carbon Fiber Ionizer Assisted Activated Carbon Fiber Filter)

  • 김두영;박재홍;황정호
    • 한국입자에어로졸학회지
    • /
    • 제6권4호
    • /
    • pp.185-192
    • /
    • 2010
  • This paper reports that the installation of a carbon fiber ionizer in front of an activated carbon fiber(ACF) filter enhanced the antibacterial efficiency. In addition, the effect of the ionizer on the filtration of bioaerosols is reported. Negative air ions from the ionizer were used as antibacterial agent. The test bacteria(Escherichia coli) were aerosolized using an atomizer and were deposited on the ACF filter media for 10 minutes. E. coli deposited on the filter were exposed to negative air ions for 0, 1, 5 and 10 minutes. Then they were separated from the ACF filter by shaking incubation with nutrient broth for 4 hours. The separated E. coli were spread on nutrient agar plates and incubated at $37^{\circ}C$ for 1~3 days. The antibacterial efficiency of E. coli was measured using a colony counting method. The antibacterial efficiencies of E. coli exposed to negative air ions for 1, 5 and 10 minutes were 14%, 48% and 71%, respectively. The filtration efficiency was evaluated by measuring the number concentration of bioaerosols at the upstream and downstream of the filter media. The increase of filtration efficiency by air ions was 14%, that is similar to the 17% filtration efficiency by none air ions. The ozone concentration was below the detection limit (under 0.01ppm) when the carbon fiber ionizers were on.

여과형 비점오염 처리장치의 오염물질 제거특성 및 역세척 분석 (The Performance of Pollutant Removal Using Nonpoint Treatment Filtration Device and Analysis of the Filter Backwashing Effect)

  • 이준호;양승호;방기웅
    • 한국물환경학회지
    • /
    • 제31권5호
    • /
    • pp.523-532
    • /
    • 2015
  • Hydrocyclone is widely used in industry, for its simple design, high capacity, low maintenance and low operational cost. The objective of this study is to develop hydrocyclone coagulation and filtration system. The system is made of hydrocyclone ballasted coagulation with polyaluminium chloride silicate (PACS) and upflow filter to treat micro particles in urban storm runoff. Roadside sediment particles (< $200{\mu}m$) was mixed with tap water to make various turbid suspensions to simulate urban storm runoff. The filter cartridge was filled with polyethylene media system and ran 1hr per everyday and total operation time were 8.19hrs and backwashing everyday after end of operation. The operation condition of flowrate was $8.2{\sim}11.9m^3/day$ (mean $10.1m^3/day$) and surface overflow rate (SOR) based on filter surface area was $45.5{\sim}65.9m^3/m^2/day$ (mean $55.7m^3/m^2/day$). The range of PACS dosage concentration was 14.0~31.5 mg/L. As the results of operation, the range of removal efficiency of turbidity, SS were 81.0~95.8% (mean 89.5%) 81.8~99.0% (mean 91.4%), respectively. An increase of filtration basin retention time brought on increased of removal efficiency of turbidity and SS, and increase of SOR brought on decreased of removal efficiency. During the first flush in urban area, storm runoff have an high concentration of SS (200~600 mg/L) and the filtration bed becomes clogged and decreased of removal efficiency. Backwashing begins when the drainage pipe valve at the filtration tank bottom is completely open (backwashing stage 1). Backwashing stage 2 was using air bubbles and water jet washing the media for 5 mins and open the drainage valve. After backwashing stage 1, 2, 61.83~64.04%, 18.53~27.51% of SS loading was discharged from filtration tank, respectively. Discharged SS loading from effluent was 7.12~14.79% and the range of residual SS loading in fliter was 2.26~5.00%. The backwashing effects for turbidity, SS were 89.5%, 91.4%, respectively. The hydrocyclone coagulation and filtration with backwashing system, which came out to solve the problems of the costly exchange filter media, and low efficiency of removing micro particles of filter type nonpoint treatment devices, is considered as an alternative system.

정수처리 공정에서 Cryptosporidium Tracer의 제거효율 (Removal Efficiency of Cryptosporidium Tracer in Drinking Water Treatment Process)

  • 이순화;김윤희
    • 대한환경공학회지
    • /
    • 제28권12호
    • /
    • pp.1304-1309
    • /
    • 2006
  • 정수처리 과정에서 Cryptosporidium과 유사한 특성을 가지고 있는 C. tracer를 이용하여 공정별 제거효율을 조사하였다. PACI(Poly aluminium chloride, $Al_2O_3$(10%)) 주입량이 10 mg/L일 때 C. tracer는 97.16%로 가장 높은 제거율을 보였으며, 탁도 제거율과 SS 제거율이 높을수록 C. tracer 응집 효율이 높았다. 원수의 pH가 높을수록 C. tracer 제거율이 증가 하였으며 응집 침전 후의 유출수 탁도와 C. tracer 제거율과의 상관성이 $R^2=0.9506$로 높게 나타나 응집 침전 후의 유출수 탁도로 Cryptosporidium 제거 효율을 평가할 수 있음을 알 수 있었다. 또한 여과 실험에서는 유입 탁도에 따른 C. tracer 제거율은 $94.00{\sim}95.83%$ 범위였으며 유출수 탁도와 C. tracer 제거율과의 상관성은 $R^2=0.8704$였다. 최적 응집 조건 하에서 여과수 탁도가 양호할 경우, 예상되는 Cryptosporidium의 제거율은 응집 침전의 경우 1.55 log(97.16%), 급속모래여과의 경우 1.38 log(95.83%), 응집 침전+급속모래여과의 경우 2.31 log(99.51%)로 나타났다.

고농도 휴믹성분이 포함된 강 원수에서 응집-침전 및 오존 공정을 전처리로 적용한 오존 내성막 pilot plant에서의 운전성 및 투과수 수질변화에 관한 연구 (Pre-Coagulation and Pre-Ozonation for Ozone Resisting Microfiltration Membrane Filtration System of a High Humic Contained Surface Water)

  • 이상협;와타나베 요시마사;이석헌;안규홍
    • 상하수도학회지
    • /
    • 제18권5호
    • /
    • pp.598-607
    • /
    • 2004
  • In this study, the effects of two pre-treatment processes were observed prior to membrane filtration: pre-coagulation and pre-ozonation. To compare the effect of two above-mentioned pre-treatments, we adopted the four schemes: first one is direct membrane filtration of river surface water, second one is membrane filtration after pre-coagulation, third one is membrane filtration after pre-ozonation and fourth one is membrane filtration after pre-coagulation and pre-ozonation. There are two exceptional characteristics in applied processes. One is the usage of the MF membrane which has high ozone resisting characteristic. Therefore, ozone resides in membrane module during filtration. The other is adoption of Jet Mixed Separator (JMS) as coagulation-sedimentation process. The change in transmembrane pressure and permeate water quality were also examined. As a result, considering the filtration performance efficiency and permeate water quality, the process composed of filtration with combination of both pre-coagulation and pre-ozonation was proved most effective. The improved efficiency was due to the reduction of loading rate of fouling inducing materials to membrane module by coagulation process as well as variable reactions, such as degradation, particle destabilization and coagulation, occurred by residual ozone in membrane module. The additional effect of pre-coagulation before pre-ozonation is suppression of AOC, one of the by-products induced by ozonation. Therefore, combination of pre-coagulation and pre-ozonation is the effective process to overcome the major de-merit of ozonation i.e. by-products formation.

시판되고 있는 유사마스크 제품의 여과효율성능 비교평가 (Evaluation of Filtration Performance Efficiency of Commercial Cloth Masks)

  • 장지영;김승원
    • 한국환경보건학회지
    • /
    • 제41권3호
    • /
    • pp.203-215
    • /
    • 2015
  • Objectives: This study was designed to evaluate the filtration efficiencies and pressure drops of five commercial cloth masks (4 plate type, 1 cup type) in comparison to the performance of a class 1 disposable respirator (reference respirator). A further objective was to evaluate the effects of the number of layers and wash treatment independently on filtration efficiencies and pressure drops. Methods: Polydisperse NaCl aerosols were generated in an aerosol chamber and their concentrations were measured by an optical particle counter (OPC) in the size range of $0.3{\sim}10{\mu}m$ (five channels). Results: The filtration efficiencies of the five cloth masks and the reference respirator were D: 9.5%, C: 18.5%, E: 23.6%, A: 28.5%, B: 29.7% and R: 91.1%, respectively, and the pressure drops through them were C, D: 0.8 Pa, E: 1.7 Pa, B: 6.4 Pa, A: 42.7 Pa and R: 19.3 Pa, respectively. The filtration efficiencies of the cloth masks and reference respirator were below the class 1 respirator criterion (${\geq}94.0%$) of the Ministry of Employment and Labor (MOEL) and Ministry of Food and Drug Safety (MFDS). The pressure drops satisfied the class 1 respirator criterion (${\leq}70Pa$) of MOEL and MFDS. When the cloth masks were folded into two and four layers, the filtration efficiencies of cloth masks A, B, C, D (plate type) increased 1.7-4.6 times, and 2.3-6.8 times, respectively, compared to the efficiencies of the same products in a single layer. Pressure drops increased as the number of layers was increased. The filtration efficiency of cloth mask E with a liner was 1.3 times higher than that of the same mask without a liner, and the pressure drop was lower in the no-liner configuration. After a single washing, the filtration efficiencies of all the cloth mask products decreased 1.04-4.0 times compared to those of the same products intact. For the cloth masks C and E, their filtration efficiencies were significantly decreased after washing (p<0.05). The pressure drops of all cloth masks were 1.2-2.0 times lower after washing. Conclusions: The filtration efficiencies of the five cloth masks were below 30% and did not improve greatly by increasing the number of layers. After a single washing, their performances decreased. Considering the above and other issues identified with cloth masks, such as poor fit and stretched fibers through use, people should not expect protection against particulate matters from the cloth masks on the market.

Distortion of Eelectrical Double Layer in Liquid Filtration by Fibrous Filters

  • Lee, Myong-Hwa;Hirose, Shogo;Otani, Yoshio
    • 한국입자에어로졸학회지
    • /
    • 제10권3호
    • /
    • pp.99-108
    • /
    • 2014
  • Liquid filtration by membrane filters is essential for the preparation of ultrapure water in semiconductor manufacturing processes. The separation of submicrometer particles suspended in ultrapure water with a laminated fibrous membrane filter was studied numerically and experimentally in the present work. We found that an electrical double layer around a single fiber expanded to a large extent at a low ion concentration, as in ultrapure water, and deformed toward the upstream of the fiber with increasing filtration velocity. Since an increase in the electrical double-layer thickness leads to a decrease in the electrical potential gradient, particles with the same polarity as the fiber approach the fiber more easily and are captured at a high filtration velocity. Experimental results also confirmed that the collection efficiency of polystyrene latex(PSL) particles through a PTFE filter became higher as the filtration velocity increased.

다회용 마스크 유형에 따른 성능 비교연구 (A Comparison of Performance Evaluations of Reusable Masks)

  • 류회진;박원희;이춘영;정선옥;최희진;이정미;황인숙;신용승
    • 한국산업보건학회지
    • /
    • 제32권1호
    • /
    • pp.53-63
    • /
    • 2022
  • Objectives: This study was designed to evaluate the filtration efficiency, inhalation resistance, and liquid resistance of commercial reusable masks in comparison to the performance of KF-AD masks (reference masks). Methods: Thirty-six masks were purchased from an online market. Filtration efficiency and inhalation resistance were determined in the same manner as in MFDS certification testing, respectively using TIL/IL & Filter Test 1300S (SFP Services, UK) and Breathing Resistance Analyzer DA2001 (Lambda Ray, South Korea). Results: Most of the filtration efficiencies found for the 19 masks were far lower than the test standard for KF-certified masks. Four masks met KF94 and three masks even met KF80. Most inhalation resistances were also much lower than the standard, with many almost one-half of the standard. In addition, all the masks except KF-AD masks did not pass the liquid resistance test. Conclusions: Although most of the filtration efficiency performance results found in this study for the reusable masks, which emerged as an alternative, were lower than the standard for health masks, multi-use masks can be used with a replacement filter inserted.

외부전기장 적용 섬유상 에어필터의 절연 전극 사용에 따른 여과특성 (Filtration Performance of Fibrous Air Filter under External Electric Field using Insulated Electrodes)

  • 지성미;손종렬;박현설
    • 한국대기환경학회지
    • /
    • 제28권6호
    • /
    • pp.675-687
    • /
    • 2012
  • Applying an external electric field across air filter media is one of methods to improve the filtration performance. Metal wire meshes have been commonly used as electrodes situated on both sides of a thick filter pad. For a thin filter medium a short circuit, known as the biggest drawback for applying an external electric field to air filter, can occur at the closest point between electrodes. In this study several types of insulated meshes were prepared by coating #50 meshes with a dielectric material, Nylon 66, and the filtration property of air filter was evaluated at the presence of external electric field using those insulated meshes as electrodes and compared with that of filters using bared meshes. The collection efficiency of tested filter was increased from 78% to 95% for singly charged 100 nm particles by application of external electric field. As a result, there was no significant difference in collection efficiency between filters with insulated and bared electrodes. Similar results could be also seen from the tests using polydisperse particles. Finally, through this study, we found that the insulation of mesh electrodes doesn't affect the filtration performance of fibrous air filter under external electric field.