• Title/Summary/Keyword: Filtering efficiency

Search Result 409, Processing Time 0.02 seconds

Development of an evaluation method for nuclear fuel debris-filtering performance

  • Park, Joon-Kyoo;Lee, Seong-Ki;Kim, Jae-Hoon
    • Nuclear Engineering and Technology
    • /
    • v.50 no.5
    • /
    • pp.738-744
    • /
    • 2018
  • Fuel failure due to debris is a major cause of failure in pressurized water reactors. Fuel vendors have developed various filtering devices to reduce debris-induced failure and have evaluated filtering performance with their own test facilities and methods. Because of the different test facilities and methods, it is difficult to compare filtering performances objectively. This study presents an improved filtering test and an efficiency calculation method to fairly compare fuel-filtering efficiency regardless of the vendor's filtering features. To enhance the reliability of our evaluation, we established requirements for the test method and had a facility constructed according to the requirements. This article describes the debris specimens, the amount of debris, and the replicates for the proposed test method. A calculation method of comprehensive debris-filtering efficiency using a weighted mean is proposed. The test method was verified by repeated tests, and the tests were carried out using the PLUS7 and 17ACE7 test fuels to calculate the comprehensive debris-filtering efficiencies. The evaluation results revealed that the filtering performance of PLUS7 is better than that of 17ACE7. The proposed method can be used on any kind of debris-filtering devices and is appropriate for use as a standard.

Filtration efficiency and Manikin-based Total Inward Leakage Study of Particle Filtering Mask Challenged with Silver Nanoparticles (은나노입자에 대한 방진마스크 포집효율 및 총누설율)

  • Kim, Jong-Kyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.367-376
    • /
    • 2016
  • Objectives: The production and use of nanoparticles have been increased. In 2014 Workplace Survey Results, 335 companies produce and treat nanoparticls. However, lack of data on nano-toxicity and a method for risk management and regulation on nanoparticles and the standard test method are not sufficient. Protective equipment selection guidelines for nanoparticles are not established. It is required to carry out respirator efficiency test against nanoparticles. This study was performed to evaluate filtration efficiency and manikin-based total inward leakage of particle filtering mask using in Korean country challenged with silver nanoparticles. Methods: We investigated filtration efficiency and total inward leakage of 7 respirator with silver nanoparticle. Results: The geometric mean diameters of Silver nanoparticles were 30 nm and number concentration were about $10^6{\sharp}/cm^3$. Filtration efficiency of six of the seven particle filtering masks was more than 98% and one particle filtering masks filtration efficiency was 94.9%. The filtration efficiency of particle filtering masks to 20 nm silver nanoparticels was highest. Artificial breathing machine with manikin based total inward leakage were 7.6% ~ 42.3%. Conclusions: The results of this study nano-silver filter efficiency was high but the total inward leakage was higher than filter penetration. Therefore, education on how to wear a respirator should be demanded. Especially for workers handling nanoparticles and toxic material, user seal checking and fit test must be performed.

Numerical Analysis of Fluid Flow and Filtering Efficiency in Centrifugal Oil Filter (원심 오일필터 유동 해석을 통한 필터링 효율 분석)

  • Bang, Kwang-Hyun;Kim, Kyung-Kyu;Song, Young-A;Kim, Pyung-Su
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.867-872
    • /
    • 2009
  • In centrifugal oil filters particles are forced to move toward the filter casing wall by centrifugal force in the rotating oil flow and the particles are trapped and removed on the filter paper installed at the wall. In the present study, flow field of oil and particle motion in a centrifugal oil filter has been numerically calculated in order to estimate the filtering efficiency for various operating conditions. Fluent code was used for the numerical calculations. Uncoupling the oil flow and the particle motion and the use of particle tracking trajectory enabled the estimation of filtering efficiency for various particle sizes, particle density and the filter rotational speed. Higher filtering efficiency was observed for heavier and larger particles as well as higher filter rotational speed. For the typical case of the particle density of $6000kg/m^3$ and the particle size of $10{\mu}m$ at 3500 RPM, the calculated filtering efficiency per passage was 0.31.

Study on Performance Improvement of Video in the H.264 Codec (H.264 코덱에서 동영상 성능개선 연구)

  • Bong, Jeong-Sik;Jeon, Joon-Hyeon
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.532-535
    • /
    • 2005
  • These days, many image processing techniques have been studied for effective image compression. Among those, 2D image filtering is widely used for 2D image processing. The 2D image filtering can be implemented by performing ID linear filtering separately in the direction of horizontal and vertical. Efficiency of image compression depends on what filtering method is used. Generally, circular convolution is widely used in the 2D image filtering for image processing. However it doesn't consider correlations at the region of image boundary, therefore filtering can not be performed effectively. To solve this problem. I proposed new convolution technique using Symmetric-Mirroring convolution, satisfying the 'alias-free' and 'error-free' requirement in the reconstructed image. This method could provide more effective performance than former compression methods. Because it used very high correlative data when performed at the boundary region. In this paper, pre-processing filtering in H.264 codec was adopted to analyze efficiency of proposed filtering technique, and the simulator developed by Matlab language was used to examine the performance of the proposed method.

  • PDF

A Study on the Performance Assessment of Nuclear Fuel Debris Filtration Using the Weighted Mean (가중평균을 이용한 핵연료 이물질 여과성능 평가에 관한 연구)

  • Park, Joon Kyoo;Lee, Seong Ki;Kim, Jae Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.2
    • /
    • pp.149-156
    • /
    • 2017
  • Nuclear fuel requires high reliability and safety and therefore contains debris filtering devices to prevent failure-inducing debris from entering it. The debris filtering performance of nuclear fuel is one of the most important factors for fuel integrity. Therefore, the performance must be evaluated and the measurement must be reasonable. In this study, a calculation method of the comprehensive filtering efficiency using the weighted mean was proposed to establish a standard filtering efficiency index. To confirm the suitability of the proposed method, representative debris specimens were selected and the filtering efficiency with the weighted mean was compared with the efficiency of the arithmetic mean. The weighting factor of the weighted mean was introduced to produce a fair evaluation. In addition, the analysis of the debris filtering mechanism was performed according to the size of debris specimens, and the main dimensions of the filtering feature for commercial nuclear fuel.

Comparison of Recommendation Techniques for Web-based Design Personalization Service (웹기반 개인화 디자인 서비스를 위한 효과적인 추천 기법의 비교 연구)

  • Seo, Jong-Hwan;Byun, Jae-Hyung;Lee, Kun-Pyo
    • Science of Emotion and Sensibility
    • /
    • v.9 no.spc3
    • /
    • pp.179-185
    • /
    • 2006
  • This study examines and compares various recommendation techniques which have been used successfully in other fields and seeks for opportunity to improve design personalization service more effectively. Throughout the literature study, several major recommendation techniques were identified, namely 'contents-based filtering', 'collaborative filtering', and 'demographic filtering'. In order for finding out relative advantages and disadvantages, a case study was carried out by applying different techniques. The result showed that in general, demographic filtering was evaluated least efficient among the techniques. Content-based filtering showed the best efficiency among them. Another significant finding was that the collaborative filtering had a better efficiency as the number of test subjects is increased. In conclusion, we suggest that design recommendation services can be improved by applying contents-based or collaborative filtering for better efficiency of recommendation. And, if the number of test subjects is large enough, it may be possible to remarkably improve the efficiency of design recommendation services by using collaborative filtering.

  • PDF

A Study on Filtering Techniques for Dynamic Analysis of Data Races in Multi-threaded Programs

  • Ha, Ok-Kyoon;Yoo, Hongseok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.11
    • /
    • pp.1-7
    • /
    • 2017
  • In this paper, we introduce three monitoring filtering techniques which reduce the overheads of dynamic data race detection. It is well known that detecting data races dynamically in multi-threaded programs is quite hard and troublesome task, because the dynamic detection techniques need to monitor all execution of a multi-threaded program and to analyse every conflicting memory and thread operations in the program. Thus, the main drawback of the dynamic analysis for detecting data races is the heavy additional time and space overheads for running the program. For the practicality, we also empirically compare the efficiency of three monitoring filtering techniques. The results using OpenMP benchmarks show that the filtering techniques are practical for dynamic data race detection, since they reduce the average runtime overhead to under 10% of that of the pure detection.

Model of dynamic clustering-based energy-efficient data filtering for mobile RFID networks

  • Vo, Viet Minh Nhat;Le, Van Hoa
    • ETRI Journal
    • /
    • v.43 no.3
    • /
    • pp.427-435
    • /
    • 2021
  • Data filtering is an essential task for improving the energy efficiency of radiofrequency identification (RFID) networks. Among various energy-efficient approaches, clustering-based data filtering is considered to be the most effective solution because data from cluster members can be filtered at cluster heads before being sent to base stations. However, this approach quickly depletes the energy of cluster heads. Furthermore, most previous studies have assumed that readers are fixed and interrogate mobile tags in a workspace. However, there are several applications in which readers are mobile and interrogate fixed tags in a specific area. This article proposes a model for dynamic clustering-based data filtering (DCDF) in mobile RFID networks, where mobile readers are re-clustered periodically and the cluster head role is rotated among the members of each cluster. Simulation results show that DCDF is effective in terms of balancing energy consumption among readers and prolonging the lifetime of the mobile RFID networks.

A Study on Improvement of 2-Dim Filtering Efficiency for Image (2차원 영상 필터링 효율 향상을 위한 기술연구)

  • Jeon, Joon-Hyeon
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.6
    • /
    • pp.99-110
    • /
    • 2005
  • These days, many image processing techniques have been studied for effective image compression. Among those, The 2D image filtering is widely used for 2D image processing. The 2D image filtering can be implemented by performing the 1D linear filter separately in the horizontal and vertical direction. Efficiency of image compression depends on what filtering method is used. Generally, circular convolution is widely used in 2D image filtering for image processing. However it doesn't consider correlations at the boundary region of image, therefore effective filtering can not be performed. To solve this problem. I proposed new convolution technique using loop convolution which satisfies the 'alias-free' and 'error-free' requirement in the reconstructed image. This method could provide more effective compression performance than former methods because it used highly-correlated data when performed at the boundary region. In this paper, Sub-band Coding(SBC) was adopted to analyze efficiency of proposed filtering technique, and the simulator developed by Java-based language was used to examine the performance of proposed method.

Identification of operating parameters in auto-discharging filter system for treatment of urban storm water (자동방류가 가능한 여과형 비점오염처리장치의 운전인자 도출)

  • Kim, Sun-Hee;Gwon, Eun-Mi;Pak, Sung-Soon;Joh, Seong-Ju;Lim, Chea-Hoan;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.4
    • /
    • pp.377-386
    • /
    • 2010
  • To identify operating parameters of the up-flow filtering system, which is available to discharge filtering residue after the rain, developed for treatment of urban storm runoff, lab scale test was carried out. Removal efficiency of SS was 68.7%, 62.2%, and 58.6% at the area roading rate of 2.46m/h, 4.68m/h, and 10m/h, respectively, filtering device is desirable to operate at the lower than 4.68m/h of area roading rate to get higher level of 60% SS removal efficiency. The removal efficiency of SS was 57.1% ~ 68.7% at the raw water SS of 100mg/L ~ 600mg/L, and the SS in treated water was maintained at the constant level through the elapsed time. It is indicate that filtering device can guarantee a certain level of effluent water quality at various raw water quality. The removal efficiency of SS to the depth of filter media was 68.3%, 78.6% at the filter depth of 10 cm, 20cm respectively. The final treated water quality was showed 30.2mg/L of CODMn, 1.60mg/L of TN and 0.25mg/L of TP. The average removal efficiencies by filtering device developed in this research were recorded slightly lower levels than other research. The main reason of these results were the first, the filter depth of the media used in this test was shallow, the second, the kind of filter media in discharge port of residue. More research to kind of filter media, filter packing rate, select of media for residue discharge port should be go on to produce optimum operating condition. The result of this study would be valuable for the application of filtration device to control of urban storm water.