• Title/Summary/Keyword: Filter paper contact method

Search Result 22, Processing Time 0.03 seconds

A Study of Form Measurement using Noncontact Sensor (비접촉식 센서를 사용한 형상 측정 연구)

  • 송정섭;황윤호;배종일;이만형
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.407-410
    • /
    • 1995
  • Many researches on measurement technology has been made and developed by various methods. Considering the measurement environment with cutting fluid, coolant and the like, contact type measurement methods are mostly used. But contact measurement method has measuring force and so the sensing head becomes worn. By these reasons, we considered sensors not influenced by the former fluid and so can acquire accrate measured values using error compensation due to temperature and vibration. For this purpose, eddy current sensors and Extended kalman Filter Algorithm for processing measured data has been used. In this paper, we present new technology that can be used for measuring workpiece with previous bad environment using direct method and comparison measurement method. We used cylindrical workpieces which were produced by grinding machine for the target.

  • PDF

Contactless feed-back control method through power stage transformer in non-contact battery charger (무접점 충전기의 전력단 변압기를 통한 무접점 피드백 제어방식)

  • 김창균
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.258-261
    • /
    • 2000
  • A non-contact battery charger which transfers energy using magnetic field has a difficulty with a feed-back control due to the interaction between the power and signal processing This paper proposes an effective method which uses auxiliary windings of transformer as signal path and copes with cross-talk using the MOSFET ringing phenomenon and ceramic filter. The power stage is half-bridge series resonant converter. Design procedure and experimental verification are presented.

  • PDF

Measurement of Vibration Signals of a Gun Barrel Type Structure using Mechanical Filter (기계적 필터를 이용한 포신형상 구조물의 진동신호 측정)

  • Ryu, Bong-Jo;Koo, Kyung-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.440-443
    • /
    • 2010
  • This paper deals with the method of vibration measurement of a gun barrel structure using mechanical filter. When a bullet with high speed is moving within a gun barrel type structure with low bending vibration frequencies, it is difficult to measure the bending vibration signals of the structure. For example, noncontact type sensors such as displacement or velocity sensor are not appropriate for the measurement of vibrational signals because of the movement effect of the equipment frame through the moving structures or effect of the ground vibration. One of contact type sensors such as accelerometer is profitable for measurement of vibrational signals because of its wide measurement ranges. In the case of a gun barrel structure including high vibrational signals like shock waves, however, it is necessary to propose vibration measurement method filtering high frequencies. The purpose of the paper is to propose the proper vibrational measurement technique filtering high frequencies of a gun barrel type structure.

contactless power conversion system using the Boost converter (승압형 컨버터를 활용한 비접촉식 전력변환 시스템)

  • Lee S. J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.214-217
    • /
    • 2003
  • The connectorless power supply system on that multi-contact causes confidence when the wiring reconstructed in the rear. As you see above, contact points between sets and indoor space cause inferior function of audio frequency so it needs to be eliminated. This paper explains the structure of connectorless power supply to supply the system with power crossing the air gap in the part of inductively in the connectorless power supply of both magnetic and electrical model. To get maximum output of electrical load, compensating capacitor compensates to show inter-inductance, lequeage-inductance reducing the track-inductance and access the conditions for resonance. At that time it accesses the maximum electric power. The small change of the value of compensating capacitor causes the changes of maximum electric power. Here the power electronics technology is used not only in the industrial machinery but also in the home appliances so the switching power supply is used to actualize the miniaturization, lightweight, and high efficiency. Generally the condenser input methods are widely used in the rectification circuit of switching power supply, but condenser input method generate great quantity of high frequency components because with this method the current flows in the power input filtering condenser only around value of peak of ac input voltage. To solve these problems, installation of power factor improve circuit on the front of filtering capacitence was considered. Several methods were suggested regarding, but the active filter method which makes smalliging and highly power factor possible are the produce main stream. IC for power factor improvement can be utilized by CMOS process proposing low power consumption. When the high power factor is considered seriously in the power factor improvement circuit, active filter method is selected. In the active filter method, the boost converter is used. Regarding this ·the boost converter is needed.

  • PDF

A Development of SFD for the measurement of rotational velocity vector (회전 속도 Vector 계측을 위한 공간필터 검출기의 개발)

  • Go, Hyun-Min;Rho, Do-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.621-624
    • /
    • 1999
  • In this paper, we propose the non-contact method to measure rotational speed vector using spatial filtering method. The rotational speed $\omega$ is known by the frequency of output sinusoidal signal direct proportional to that and the rotational direction is given by the phase delay from the weighting function design of spatial filter.

  • PDF

Susceptibilities of German Cockroach, Blattella germanica to Insecticides According to Application Methods (바퀴에 대한 처리방법에 따른 살충제 감수성)

  • Han Jongbeen;Kim Gil-Hah
    • Korean journal of applied entomology
    • /
    • v.43 no.3 s.136
    • /
    • pp.241-247
    • /
    • 2004
  • Susceptibility of Blattella germanica male adults to 61 commercial insecticides was evaluated by diet dipping method. Among them three insecticides of dichlorvos, fenitrothion, and fipronil showed over $90\%$ mortality. The insect was more susceptible to dichlorvos and fenitrothion in filter paper contact method than in diet dipping one, but fipronil was vice versa. Toxicities of the three chemicals were evaluated by application parts of the such as head, thorax, abdomen, and legs. Dichlorvos and fenitrothion were more toxic when applied to head, and flpronil was thorax. $LT_{50}$ values by diet dipping method showed that fenitrothion and fipronil acted more rapidly than boric acid and hydramethylnon. The values of the former two were 1.05 and 0.98 days, and those of the latter two were 3.92 and 2.26 days, respectively.

Susceptibilities of american cockroach, Periplaneta americana to insecticides according to application methods (이질바퀴에 대한 처리방법에 따른 살충제 감수성)

  • Han, Jong-Been;Bae, Jeong-Sook;Kim, Gil-Hah
    • The Korean Journal of Pesticide Science
    • /
    • v.8 no.3
    • /
    • pp.210-219
    • /
    • 2004
  • Susceptibility of Periplaneta americana male adults to 61 commercial insecticides was evaluated by diet dipping method. Among them eight insecticides of dichlorvos, benfuracarb, cypermethrin, deltamethrin, fenpropathrin, $\zeta$-cypermethrin, $\lambda$-cyhalothrin and fipronil showed 100% mortality. The insect was more susceptible to dichlorvos and fenpropathrin in filter paper contact method than in diet dipping one, but benfuracarb was vice versa. Toxicities of the seven chemicals were evaluated by application parts of the such as head, thorax, abdomen, and legs. Dichlorvos, benfuracarb and $\lambda$-cyhalothrin were more toxic when applied to head, and deltamethrin, fenpropathrin and cypermethrin were abdomen. $LT_{50}$ values by diet dipping method showed that dichlorvos, benfuracarb and $\lambda$-cyhalothrin acted more rapidly than boric acid and hydramethylnon. The values of the former three were 0.10, 0.29 and 0.12 days, and those of the latter two were 6.2 and 4.8 days, respectively.

Measurement of Vibration Signals of a Gun Barrel Type Structure using Mechanical Filter (기계적 필터를 이용한 포신형상 구조물의 진동신호 측정)

  • Ryu, B.J.;Lee, G.S.;Shin, G.B.;Oh, B.J.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.181-184
    • /
    • 2007
  • This paper deals with the method of vibration measurement of a gun barrel structure using mechanical filter. When a bullet with high speed is moving within a gun barrel type structure with low bending vibration frequencies, it is difficult to measure the bending vibration signals of the structure. For example, noncontact type sensors such as displacement or velocity sensor are not appropriate for the measurement of vibrational signals because of the movement effect of the equipment frame through the moving structures or effect of the ground vibration. One of contact type sensors such as accelerometer is profitable for measurement of vibrational signals because of its wide measurement ranges. In the case of a gun barrel structure including high vibrational signals like shock waves, however, it is necessary to propose vibration measurement method filtering high frequencies. The purpose of the paper is to propose the proper vibrational measurement technique filtering high frequencies of a gun barrel type structure.

  • PDF

A Non-contact Realtime Heart Rate Estimation Using IR-UWB Radar (IR-UWB 레이더를 이용한 비접촉 실시간 심박탐지)

  • Byun, Sang-Seon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.14 no.3
    • /
    • pp.123-131
    • /
    • 2019
  • In recent years, a non-contact respiration and heart rates monitoring via IR-UWB radar has been paid much attention to in various applications - patient monitoring, occupancy detection, survivor exploring in disaster area, etc. In this paper, we address a novel approach of real time heart rate estimation using IR-UWB radar. We apply sine fitting and peak detection method for estimating respiration rate and heart rate, respectively. We also deploy two techniques to mitigate the error caused by wrong estimation of respiration rate: a moving average filter and finding the frequency of the highest occurrence. Experimental results show that the algorithm can estimate heart rate in real time when respiration rate is presumed to be estimated accurately.

A Study on the Selecting Determine Factors of Optical Filter for Recognition Financial Account Using Delphi Method (델파이법을 이용한 금융통장 정보 인식용 광학필터 결정인자 도출에 관한 연구)

  • Yu, Hyeung Keun;Lee, Kang Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.1
    • /
    • pp.61-69
    • /
    • 2014
  • In this paper, we have researched semiconductor optical filters to solve the problem of the high failure rate that are recognize bad of financial account, jam of financial account and the ATM service interruption due to failure of accurate location information among the operation of the ATM (automatic teller machine) systems. A semiconductor optical filters that have high resolution and less diffuse, high transmittance are able to detect the information of financial account surface accurately. Therefore, it is a stable filter that is able to minimize the incidence of disability. In this paper, we drew the determinants by element for implement an excellent semiconductor optical filters. Based on this, we had to be able to implement the semiconductor optical filter that is able to be mounted on the actual ATM system through future studies.