• 제목/요약/키워드: Filter factor

검색결과 832건 처리시간 0.029초

단일동조 수동고조파필터 설계시의 동조계수(δ) 및 양호도(Q)값 연구 (A Study on Tuning Factor(δ) and Quality Factor(Q) Values in Design of Single-Tuned Passive Harmonic Filters)

  • 조영식;차한주
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.64-70
    • /
    • 2010
  • This paper presents how to decide on tuning factor(${\delta}$) and quality factor(Q) values in design of single-tuned passive harmonic filters. Tuning factor(${\delta}$) and quality factor(Q) values have to consider before decision on circuit parameters of passive filters. A Study on these two value has not been scarcely performed and only experienced values has been used in passive harmonic filter design by far. As a experienced value, in cases of 5th and 7th filter, tuning factor(${\delta}$) is about 0.94 and 0.96 respectively and quality factor(Q) is, in all cases of, 50. If Single-tuned passive harmonic filter will be off-tuned, performance of filter will be decreased steeply and occur to parallel resonance between system reactance and filter capacitance. Therefore During the operation, In order not to off-tuning, Filter must be tuned at former order than actual tuning order. This is the same that total impedance of filter must have a reactive impedance. In this paper, Tuning factor(${\delta}$) is decided via example of real system and using the bode-plot and then performance of filters confirmed by filter current absorbtion rate. And Quality factor(Q) decided using the bode plot in example system and then performance of filters confirmed by filter current absorbtion rate also, which makes a calculated filter parameters to satisfy IEEE-519 distortion limits. Finally, Performance of the designed passive harmonic filter using the tuning factor(${\delta}$) and quality factor(Q) values, decided in this paper is verified by experiment and shows that 5th, 7th, 9th, 11th and 13th current harmonic distortions are decreased within IEEE-519 distortion limits, respectively.

모델 전이 기법을 이용한 기압고도계의 오차 추정 (Estimation of baro-altimeter errors via model transition technique)

  • 황익호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.32-35
    • /
    • 1996
  • In this paper, it is shown that the dominant errors of baro-altimeters can be characterized by bias and scale factor errors. Also an optimal filter for estimating both bias and scale factor is derived based on the concept of model transition. The optimal filter is, however, not realizable because the model transition hypotheses increase exponentially. Therefore a realizable suboptimal filter using the interacting multiple model(IMM) technique is proposed. Computer simulation results show that the estimation errors of the proposed filter are smaller than those of the conventional least squares algorithm with a forgetting factor when both the bias and the scale factor are varying.

  • PDF

직.병렬 능동 전력필터 시스템을 이용한 불평형 전원전압 보상 (The Compensating Unbalanced Source Voltages for Unified Active Power Filter System)

  • 김영석;강민형
    • 전기학회논문지
    • /
    • 제56권4호
    • /
    • pp.716-723
    • /
    • 2007
  • This paper suggests of a 3-phase 3-wire unified active power filter. The system is composed of a series active power filter and a parallel active power filter. The proposed series active power filter compensating unbalance source voltage and current harmonics of the parallel active power filter improves power factor. The proposed algorithm which improves for power factor and harmonic reduction are calculated by the performance function, and which compensates for the unbalanced source voltage is calculated based on the symmetrical component analysis. We composed a combined system of the series active power filter and parallel active power filter to confirm a validity of the proposed control methods. The effectiveness of the proposed algorithm is confirmed by the experiments.

싸이리스터 정류부하를 위한 새로운 저원가 복합형 전력필터 (A New Low Cost Hybrid Power Filter for Thyristor-Controlled Rectifier Load)

  • 한성룡;김수근;석원엽;조정구;송의호;전희종
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권1호
    • /
    • pp.24-29
    • /
    • 2004
  • A new low cost hybrid active filter for thyristor-controlled rectifier load is presented to overcome the high cost problem of the active or the other hybrid active filters. The proposed hybrid active filter which consists of tuned (5th and 7th harmonics) LC passive filters, power factor improvement(PFI) capacitor bank, and active filter compensates power factor as well as harmonic currents. Since most of harmonic currents are filtered by the passive filter and most of reactive power is compensated by the PFI capacitor bank, the power rating of active filter can be minimized, resulting in cost minimization of the proposed hybrid active filter. A 300kVA hybrid active filter system is implemented and tested using 1MVA thyristor rectifier load to verify the operation and performance.

불평형 전원전압을 갖는 정류시스템에서 출력필터에 따른 입력 특성 분석 (Analysis of Input Characteristic in the Rectifier for Output Filter with Unbalanced Supply Voltages)

  • 강수현;김상훈
    • 산업기술연구
    • /
    • 제25권B호
    • /
    • pp.195-202
    • /
    • 2005
  • The rectifier characteristics and the quality of the input current worsens with the increase of unbalances or harmonics of the supply voltages. Rectifier input current harmonics interfere with proper power system operation, reduce rectifier power factor, and limit the power available from a given source. It is of importance to select appropriately the rectifier's output filter inductance to determine the rectifier input current waveform, the input current harmonics, and the power factor. This paper presents a quantitative analysis of single and three phase rectifier input current harmonics, total harmonic distortion, and power factor as a function of the output filter inductance under balanced and unbalanced conditions. Also, its performance under the supply voltage including harmonics be investigated. These results provide a reference for selecting reasonable rectifier's output filter inductance for given harmonics or power factor criterion.

  • PDF

Q인자 조절 가능 2차원 이산 웨이브렛 변환 필터의 설계와 성능분석 (Tunable Q-factor 2-D Discrete Wavelet Transformation Filter Design And Performance Analysis)

  • 신종홍
    • 디지털산업정보학회논문지
    • /
    • 제11권1호
    • /
    • pp.171-182
    • /
    • 2015
  • The general wavelet transform has profitable property in non-stationary signal analysis specially. The tunable Q-factor wavelet transform is a fully-discrete wavelet transform for which the Q-factor Q and the asymptotic redundancy r, of the transform are easily and independently specified. In particular, the specified parameters Q and r can be real-valued. Therefore, by tuning Q, the oscillatory behavior of the wavelet can be chosen to match the oscillatory behavior of the signal of interest, so as to enhance the sparsity of a sparse signal representation. The TQWT is well suited to fast algorithms for sparsity-based inverse problems because it is a Parseval frame, easily invertible, and can be efficiently implemented. The transform is based on a real valued scaling factor and is implemented using a perfect reconstruction over-sampled filter bank with real-valued sampling factors. The transform is parameterized by its Q-factor and its over-sampling rate, with modest over-sampling rates being sufficient for the analysis/synthesis functions to be well localized. This paper describes filter design of 2D discrete-time wavelet transform for which the Q-factor is easily specified. With the advantage of this transform, perfect reconstruction filter design and implementation for performance improvement are focused in this paper. Hence, the 2D transform can be tuned according to the oscillatory behavior of the image signal to which it is applied. Therefore, application for performance improvement in multimedia communication field was evaluated.

양질계수(Quality Factor)를 이용한 방진마스크 필터의 성능평가 (Performance of Respirator Filters Using Quality Factor (qF))

  • 한돈희;정윤석
    • 한국산업보건학회지
    • /
    • 제10권1호
    • /
    • pp.170-178
    • /
    • 2000
  • Most of manufacturers try to produce the most efficient filter for respirators with the lowest breathing resistance. Filter performance depends on low penetration, i.e., high efficiency (%), and low pressure drop ($mmH_2O$). This study was performed to evaluate performance of respirator filters by quality factor ($q_F$) and suggest the direction for improvement of respirator filters of good quality in Korea. Two mechanical filters, S and K made in Korea, three filtering facepieces, S made in China, C made in Korea and M made in USA, which were widely used in the workplace, were selected and tested efficiency and pressure drop in accordance with flow rate, using with Automated Filter Tester Model 8110 (TSI, USA). The best quality factor within the same respirator filter categories was $0.0672cm^{-1}\;H_2O$ for mechanical filter S, $0.0698cm^{-1}\;H_2O$ for filtering facepiece M at flow rate of 32Lpm. Mechanical filter S would be the best suitable during heavy work since qulity factors decrease less sharply than any others as increased flow rates. It was necessary for mechanical filter S to lower pressure drop without increasing efficiency, but mechanical filter K should be increased efficiency and decreased pressure drop. While filtering facepiece M had the best quality performance of three ones, Sand C should get much higher efficiency and lower pressure for better performance.

  • PDF

가변 축척 매개변수를 가진 변형 확률적 경사도 기반 필터의 해석 (Analysis of a Modified Stochastic Gradient-Based Filter with Variable Scaling Parameter)

  • 김해정
    • 한국통신학회논문지
    • /
    • 제31권12C호
    • /
    • pp.1280-1287
    • /
    • 2006
  • 본 논문은 변형 확률적 경사도 기반 (MSGB) 필터를 제안하고 그 필터가 최적화 문제에 대한 해가 될 수 있음을 보여준다. 갱신항으로 첨가된 가변적 축척 매개변수를 가진 비선형 적응 필터인 MSGB 필터의 특성을 분석 한다. 가변 매개변수의 MSGB 필터는 가변 축척 매개변수를 통하여 고정 매개변수의 MSGB 필터와 무매개변수의 MSGB 필터를 연결하는 역할을 한다. 그 안정성 영역과 오조정량도 살펴본다. 시스템 식별에 응용하여 컴퓨터 모의실험을 실행하여 MSGB 필터의 개선된 성능 특성을 보여준다.

셀롤로오스 아세테이트 필터의 특성곡선 예측 (Predicting the Capability Curve of Cellulose Acetate Filters)

  • 김수호;임성진;김정열;신창호;이문수;김종열
    • 한국연초학회지
    • /
    • 제27권2호
    • /
    • pp.163-170
    • /
    • 2005
  • A theoretical model for predicting the capability curve of cellulose acetate filter is derived. The pressure drop is expressed as a function of the filter dimensions, the tow fiber characteristics, the filter weight, the fluid flow rate, and a filter fiber factor. Where, the filter fiber factor is affected by the distribution of the tow fibers within the filter, the relative orientations of the tow fibers, and their cross-sectional shapes. The minimum and maximum fraction of solids in capability curves determined from experimental data. Also, the filter fiber factor is expressed as a function of the filter length, tow fiber length, and tow fiber diameter. Capability curves predicted by the suggested model in this work correspond well with capability curves by experimental data.