• 제목/요약/키워드: Filter efficiency

Search Result 1,510, Processing Time 0.03 seconds

Optimal trade-off filters for Noise Robustness, Peak Sharpness and Light Efficiency in the Nonoverlapping Background Noise (배경이 물체에 겹치지 않는 영상에서 잡음에 대한 안정성, 출력의 최대값 크기, 광효율을 고려한 최적 Trade-off 필터)

  • Seong, Yeong-Kyeong;Choi, Tae-Sun
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.37 no.4
    • /
    • pp.56-64
    • /
    • 2000
  • The design of filters for pattern recognition that have optimal trade-off for the criteria of noise robustness, peak sharpness and Homer efficiency, when input scene noise is spatially disjoint (nonoverlapping) with the target, are presented Three different criteria, ie, signal-to-noise ratio, peak-to-output energy ratio and light efficiency are used to design the filter. Computer simulation is made for the various types of noise and parameters to illustrate filter performance for optical pattern recognition. When we compare the new trade-off filter with the original optimal trade-off filter, the performance of trade-off filter for nonoverlapping background is better than that of trade-off filter for overlapping background.

  • PDF

Analysis of Treatment Efficiency of Cylinder-Shaped Filter for Construction Site Runoff Control (건설현장 탁수제어를 위한 원통형 여과장치의 처리효율 분석)

  • Choi, Jongsoo;Kong, Young-San;Lee, Jung-Min;Bang, Ki-Woong
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.5
    • /
    • pp.532-538
    • /
    • 2014
  • A cylinder-shaped filter was developed to manage the runoff from construction sites. Compressed air was used for back-washing and pore sizes of filter were $23{\mu}m$ and $46{\mu}m$. The turbid water was prepared using sediments in construction sites. The grain size analysis showed that grains smaller than $38{\mu}m$ and larger than $335{\mu}m$ in size constituted 34.4 % and 37.6 %, respectively. Removal efficiency of the filter on turbidity, SS, COD, TN and TP showed 25~37%, 20~40%, 50~55%, 23~27% and 14~20%, respectively, whereas their removal efficiecy by using coagulant PAC showed 77~84%, 70~83%, 53~60%, 27~36%, and 59~75%, respectively. The filtration time was determined to be around 10 to 20 minutes. Back-washing for 10 seconds by pressurized air resulted in a satisfactory regeneration efficiency. According to the aforementioned test results, the cylinder-shaped filter is effective in reducing turbidity and would be suitable for practical application in construction sites and farms.

CFD Analysis of the Inertial Impaction Pre-Filter for a Particulate Matter Collecting Device (미세먼지 포집장치 개발을 위한 관성충돌 프리필터 유동 전산해석)

  • Kyung, Dae Seung;Hwang, Dae Sung
    • Land and Housing Review
    • /
    • v.10 no.2
    • /
    • pp.53-58
    • /
    • 2019
  • Particulate matter (PM) is designated as a group 1 carcinogen by the International Agency for Research on Cancer (IARC) of the World Health Organization (WHO). In South Korea, the health threat caused by PM is the most serious level internationally. Therefore, in order to solve the urban PM problem, it is important to develop the technology that can control PM efficiently. In this study, CFD(Computational Fluid Dynamics) simulation was performed for PM pre-filter (type 1-3 with different PM collecting room) to develop a high-efficiency PM collecting device. The complex flow field and the local flow phenomenon inside the PM collecting device were understood with CFD simulation by changing the shape and size of the pre-filter. The PM removal performance can be described with flow rate through the device and PM removal efficiency. The type-1 pre-filter with 5x5 size collecting room was confirmed to have the highest efficiency. Based on the analysis results, the optimal type of pre-filter could be developed and it would be applied as an element technology included in the PM collecting device.

Pilot Scale Test of Non-woven Fabric Filter Separation Activated Sludge Process for Practical Application on Domestic Wastewater Reclamation (파일럿 규모의 침지식 부직포 여재 활성슬러지 공정의 시스템 처리 특성에 관한 연구)

  • Lee, Sang-Woo;Choi, Chul-hoi;Park, Young-mi;Seo, Gyu-Tae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.2
    • /
    • pp.289-294
    • /
    • 2006
  • A pilot scale non-woven fabric filter separation activated sludge system was investigated for practical application on domestic wastewater reclamation and reuse. The system was operated in A/O (Anaerobic/Oxic) process with submerged filter module in the aerobic compartment. In the test of two types of filter materials ($70g/m^2$ and $35g/m^2$), the initial flux (0.42m/d) could be maintained for about three months by regular air backwashing of $70g/m^2$ filter at 0.3m water head. The removal efficiency of organic matter by the system was BOD 93.3%, CODcr 96.3%, SS 96.7%. The effluent quality was 7.8mg/L, 12mg/L and 5mg/L for BOD, CODcr and SS, respectively. The water quality was enough to meet a standard for domestic reuse without human contact. T-N removal efficiency was 49.9% at internal recycle rate 2Q and C/N ratio 3.3. The removal efficiency of T-P was 50% with average effluent concentration, 2.6mg/L.

A Study on Trapping Efficiency of the Non-point Source Pollution in Cheongmi Stream Using VFSMOD-w (VFSMOD-w 모형을 이용한 청미천 유입 비점오염물 저감효율 연구)

  • Son, Minwoo;Byun, Jisun;Yoon, Hyun-Doug;Jung, Tae-Hwa
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.1
    • /
    • pp.140-150
    • /
    • 2016
  • This study aims to investigate the effect of vegetation type, length of vegetative filter strip, and rainfall on trapping efficiency of the non-point source water pollution. Numerical experiments are carried out using VFSMOD-w. It is known from this study that the vegetation having the same value of revised Manning roughness coefficient shows the similar trapping efficiency in VFSMOD-w. When the length of vegetative filter strip increases twice, the trapping efficiency increases negligibly small under the same condition of rainfall. From this finding, it is also known that most of sediment are removed within a certain length of vegetative filter strips. It is concluded that the installation of vegetative filter strip is determined under the consideration of the rainfall characteristics, space of vegetation, and length of vegetative filter strip.

Experimental Evaluation of Filter Performance of Depth Filter Media Cartridge with Varying the Pleat Count and the Cartridge Assembly Arrangement

  • Hasolli, Naim;Park, Young-Ok;Rhee, Young-Woo
    • Particle and aerosol research
    • /
    • v.8 no.4
    • /
    • pp.133-141
    • /
    • 2012
  • A new depth filter media was designed and samples of flat sheet as well as cartridge assembly were prepared and tested to evaluate the filtration performance and compare with the commercial product. The arrangement of the depth filter media layers is important to reach the optimal filtration parameters like filter pressure drop, particle collection efficiency and dust holding capacity. Initially, both flat sheet samples of new media and commercial product have been tested using standard test units. Tests with new depth filter media cartridges of various pleat count were conducted in order to find the optimal pleat count which would represent the lowest pressure drop. These tests give an insight on how the pleat count and the assembly configuration affect the performance of the depth filter media cartridge. By comparing the samples with a commercial product we could confirm relatively high filtration performance of the sample cartridge with pleat count 150 made of new depth filter media. The cartridge with the same pleat count exhibits better performance without the outer mesh.

Optimization Design of Non-Integer Decimation Filter for Compressing Satellite Synthetic Aperture Radar On-board Data (위성 탑재 영상레이다의 온보드 데이터 압축을 위한 비정수배 데시메이션 필터 최적화 설계 기법)

  • Kang, Tae-Woong;Lee, Hyon-Ik;Lee, Young-Bok
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.475-481
    • /
    • 2021
  • The on-board processor of satellite Synthetic Aperture Radar(SAR) digitizes the back-scattered echoes and transmits them to the ground. As satellite SAR image of various operating conditions including broadband and high resolution is required, an enormous amount of SAR data is generated. Decimation filter is used for data compression to improve the transmission efficiency of these data. Decimation filter is implemented with the FIR(Finite Impulse Response) filter and here, the decimation ratio and tap length are constrained by resource requirements of FPGA used for implementation. This paper suggests to use a non-integer ratio decimation filter in order to optimize the data transmission efficiency. Also, it proposes a filter design method that remarkably reduces the resource constraints of the FPGA in-use via applying a polyphase filter structure. The required resources for implementing the proposed filter is analysed in this paper.

An Experimental Study on the Deodorization Performance Enhancement of the Air Handling Unit Using a Nano-Silver Material (은나노 소재를 이용한 공조기의 탈취 성능 향상에 관한 실험적 연구)

  • Nam, Sang-Yeob;Kang, Byung-Ha;Song, Ji-Hyeon;Han, Sung
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.739-744
    • /
    • 2009
  • The filter has long been used in purification processes for indoor air quality. To determine the deodorization effect of several filter materials in a full-scale air-handling system, the present study has been carried out using a wind tunnel equipped with a heat exchanger and various filter materials, such as commercial fabric, activated carbon(AC) and silver nano-particles attached to activated carbon(Ag-AC). The experiment was conducted using an odor substance with ammonia, acetaldehyde, acetic acid. The results obtained indicate that odor substance is substantially decreased on the moisture condensation on the surface of the heat exchanger. The fabric filter has no effect for removal of odor substances. The deodorization efficiency is found to be approximately 7% in the AC filter, while the deodorization efficiency is increased up to 10% using the Ag-AC filter.

  • PDF

Field Application of a Double Filtration Process to Control Fine Dust in a Metro Subway Station (도시 지하역사 미세먼지제어를 위한 이중여과장치의 현장적용 연구)

  • Park, Haewoo;Kim, Wooram;Jo, Youngmin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.5
    • /
    • pp.625-633
    • /
    • 2013
  • This study attempted to find an alternative method for fine dust control in the pre-exiting facilities of metro-subway stations. A new double-layer design was proposed for the MVAC (mechanical ventilation and air control) system. Several filter lay-outs were combined a pre-filter with electret filter (EF), electret bundle filter (EBF), or electret pleated filter (EPF), and were then examined focusing on the collection efficiency of particulate matters and pressure drop across the filter layers. The experimental results from the lab and field tests showed the best collection efficiency with EPF, which achieved 85% for $PM_{10}$ and 55% for $PM_{2.5}$. It was also found from the long term field test that the new filter lay-out could provide quite consistent dust level particularly in underground platform regardless of external condition.

A Study on the Development of Dust Collection System for Hull Repair (선체 표면 공사시 발생하는 분진 수거 장치 개발에 관한 연구)

  • Yoa, S.J.
    • Journal of Power System Engineering
    • /
    • v.8 no.2
    • /
    • pp.31-38
    • /
    • 2004
  • The main purpose of this study is to investigate the characteristics of hybrid collection system combined with centrifugal force of cyclone and filtration of bag filter in one unit system. The experiment and numerical simulation are executed for the analysis of collection efficiency and pressure drop characteristics of hybrid system in comparison with those of a general fabric bag filter with the various experimental parameters such as inlet velocity(filtration velocity), dust concentration and dust type, etc.. In present system, dust particles tangentially coming into the system body are controlled by the centrifugal force effect, and the next collection is made out by the filtration mechanism in the fabric filter media. Therefore, the effective first collection causes the decrease of dust loading on the fabric filter, and it presents quite a lower pressure drop of fabric filter than that of a general fabric filter. At the inlet velocity, $21{\sim}27m/sec$ and inlet concentration(fly ash) $300mg/m^3$, pressure drops through the filter media of hybrid system are shown lower as $10{\sim}22mmH_2O$ comparing to those($17{\sim}33mmH_2O$) of a general fabric bag filter.

  • PDF