• 제목/요약/키워드: Filter Method

검색결과 6,048건 처리시간 0.033초

Image Restoration by Lifting-Based Wavelet Domain E-Median Filter

  • Koc, Sema;Ercelebi, Ergun
    • ETRI Journal
    • /
    • 제28권1호
    • /
    • pp.51-58
    • /
    • 2006
  • In this paper, we propose a method of applying a lifting-based wavelet domain e-median filter (LBWDEMF) for image restoration. LBWDEMF helps in reducing the number of computations. An e-median filter is a type of modified median filter that processes each pixel of the output of a standard median filter in a binary manner, keeping the output of the median filter unchanged or replacing it with the original pixel value. Binary decision-making is controlled by comparing the absolute difference of the median filter output and the original image to a preset threshold. In addition, the advantage of LBWDEMF is that probabilities of encountering root images are spread over sub-band images, and therefore the e-median filter is unlikely to encounter root images at an early stage of iterations and generates a better result as iteration increases. The proposed method transforms an image into the wavelet domain using lifting-based wavelet filters, then applies an e-median filter in the wavelet domain, transforms the result into the spatial domain, and finally goes through one spatial domain e-median filter to produce the final restored image. Moreover, in order to validate the effectiveness of the proposed method we compare the result obtained using the proposed method to those using a spatial domain median filter (SDMF), spatial domain e-median filter (SDEMF), and wavelet thresholding method. Experimental results show that the proposed method is superior to SDMF, SDEMF, and wavelet thresholding in terms of image restoration.

  • PDF

QP 방법과 McClellan 변환을 이용한 2차원 FIR Elliptic 필터 설계에 관한 연구 (A Study on QP Method and Two Dimensional FIR Elliptic Filter Design with McClellan Transform)

  • 김남수;이상준;김남호
    • 융합신호처리학회 학술대회논문집
    • /
    • 한국신호처리시스템학회 2003년도 하계학술대회 논문집
    • /
    • pp.268-271
    • /
    • 2003
  • There are several methods for the design of 2D filter. Notable among them is McClellan transform method. This transform allows us to obtain a high order 2D FIR filter through mapping the 1D frequency points of a 1D prototype FIR filter onto 2D frequency contours. We design 2D filter using this transform. Then we notice for mapping deviation of the 2D filter. In this paper, Quadratic programming (QP) method allows us to obtain coefficients of McClellan transform. Then we compare deviation of QP method with least-squares(LS) method. Elliptic filter is used for comparison. The optimal cutoff frequencies of a 1D filter are obtained directly from the QP method. Also several problem of LS method are solved.

  • PDF

대기중의 중금속 분석을 위한 여지의 전처리 방법에 관한 연구 (The Study on Pre-treatment Method of Filter for Analysing the Heavy Metals in Air Quality)

  • 김광래;이상칠;어수미;김민영;신재영;이재영
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2002년도 춘계 국제 학술대회
    • /
    • pp.16-19
    • /
    • 2002
  • This study was carried out to establish the standardized analysis method in order to decide accurate concentrations of hazardous metals in the air. Acid decomposition method used usually was compared to microwave digestion method. Comparing results of tested background concentration in blank filter, we found that the magnitude of element concentration was Na, Ca, K, Mg, Al and Ba by order. The element concentrations of Glass fiber filter were higher than those of Quartz fiber filter, and the number of undetected components in Glass fiber filter was lower than that in Quartz fiber filter. Thus it is supposed that the concentration of background elements in Glass fiber filter was higher than those in Quartz fiber filter The extraction rate of microwave digestion method was superior to those of acid decomposition method during the test of blank filter as well as SRM of NIST. In case of the SRM of NIST, the average extraction efficiency of acid decomposition Method and microwave pretreatment is 53.8∼82.7%, 81.3∼97.1%, respectively. This result might be caused by the closed system of Microwave, which make outflow and loss of components less. Also microwave digestion method has other merits such as the minimization of time, reagents, and contamination. Furthermore, if the extraction condition, extraction time and used acids are optimized, the better results will be represented.

  • PDF

잡음 영상에서의 에지 검출 (Edge detection for noisy image)

  • 구윤모;김영로
    • 디지털산업정보학회논문지
    • /
    • 제8권3호
    • /
    • pp.41-48
    • /
    • 2012
  • In this paper, we propose a method of edge detection for noisy image. The proposed method uses a progressive filter for noise reduction and a Sobel operator for edge detection. The progressive filter combines a median filter and a modified rational filter. The proposed method for noise reduction adjusts rational filter direction according to an edge in the image which is obtained by median filtering. Our method effectively attenuates the noise while preserving the image details. Edge detection is performed by a Sobel operator. This operator can be implemented by integer operation and is therefore relatively fast. Our proposed method not only preserves edge, but also reduces noise in uniform region. Thus, edge detection is well performed. Our proposed method could improve results using further developed Sobel operator. Experimental results show that our proposed method has better edge detection with correct positions than those by existing median and rational filtering methods for noisy image.

Direct tracking of noncircular sources for multiple arrays via improved unscented particle filter method

  • Yang Qian;Xinlei Shi;Haowei Zeng;Mushtaq Ahmad
    • ETRI Journal
    • /
    • 제45권3호
    • /
    • pp.394-403
    • /
    • 2023
  • Direct tracking problem of moving noncircular sources for multiple arrays is investigated in this study. Here, we propose an improved unscented particle filter (I-UPF) direct tracking method, which combines system proportional symmetry unscented particle filter and Markov Chain Monte Carlo (MCMC) algorithm. Noncircular sources can extend the dimension of sources matrix, and the direct tracking accuracy is improved. This method uses multiple arrays to receive sources. Firstly, set up a direct tracking model through consecutive time and Doppler information. Subsequently, based on the improved unscented particle filter algorithm, the proposed tracking model is to improve the direct tracking accuracy and reduce computational complexity. Simulation results show that the proposed improved unscented particle filter algorithm for noncircular sources has enhanced tracking accuracy than Markov Chain Monte Carlo unscented particle filter algorithm, Markov Chain Monte Carlo extended Kalman particle filter, and two-step tracking method.

Robust Wavelet Kalman Filter

  • Lee, Taehoon;Park, Jinbae;Taesung Yoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.39.3-39
    • /
    • 2001
  • Since Kalman filter and wavelet transform techniques are both suitable for a nonstationary process, wavelet-Kalman filter was proposed and applied to various industrial fields. However, the wavelet-Kalman filter subjected to model uncertainty with nonstationary process has not been considered. Thus, the robust wavelet-Kalman filter method is proposed in this paper. The proposed method can prevent the degradation of filter performance when parameter uncertainty exists in both the state and measurement matrices and preserve the merits of the standard Kalman filter in the sense that it produces optimal estimates. A simple example shows that the proposed approach outperforms the standard Kalman filter and the nominal wavelet-Kalman filter.

  • PDF

분광측색계에 의한 착색 수돗물 시험방법 연구 (A study on the testing method of discolored tap water by spectrophotometer)

  • 김동헌;이종금;오지윤;김기태;전항배
    • 상하수도학회지
    • /
    • 제37권4호
    • /
    • pp.187-202
    • /
    • 2023
  • This study focuses on the application of a new measurement method that quantifies the residual color of filtered water using a spectrocolorimeter after filtering the discolored substances. It was confirmed through the color and turbidity cross-test that the discolored substances cannot be measured effectively with the current legal color and turbidity test method. Therefore, the National Institute of Environmental Research's filter testing method, which involves filtering the sample through 0.45 ㎛ filter and visually inspecting the color, was improved. A membrane filter colorimetry (MFC) method was established by measuring the color difference (ΔE*ab(65)) of the filtered filter using a spectrophotometer and expressing it as filter color unit (FCU). Using the MFC method, the FCU for reference materials such as iron and manganese, as well as field samples, was measured. The results showed a high correlation with turbidity, and the color difference patterns varied depending on the type of reference materials and field samples. This indicates that the MFC method is an effective new measurement method of discolored tap water.

아연, 산화 아연 나노 입자가 오이에 미치는 독성 및 생물이용성 (Phytotoxicity and Bioavailability of Zinc, Zinc Oxide Nanoparticles to the Cucumis sativus)

  • 송이레;남윤선;이인숙
    • 대한환경공학회지
    • /
    • 제31권7호
    • /
    • pp.467-472
    • /
    • 2009
  • Seedling 성장 실험은 나노입자에 대한 독성 평가로 사용되어 왔다. 본 연구에서는 오이에 대한 나노 아연과 나노 산화아연의 독성을 filter paper방법과 phytagel방법을 통해 평가해 보았다. 비교 결과 phytagel방법이 불용성인 나노아연, 산화 아연의 침전을 방지했다. 오이 seedling 길이는 노출된 나노 아연, 나노 산화 아연의 농도에 따라 filter 방법에서 음의 관계를 나타냈다. 나노 아연과 나노 산화 아연에 대한 오이의 EC50값은 598, 600 mg/L로 나타났다. Filter paper방법에서만 아연의 오이 내 생체 축적량은 노출된 나노 아연, 나노 산화 아연의 농도에 따라 증가하였다. 관찰 결과 filter paper방법이 phytagel 방법보다 더 좋은 protocol로 나타났다

Load Balancing Based on Transform Unit Partition Information for High Efficiency Video Coding Deblocking Filter

  • Ryu, Hochan;Park, Seanae;Ryu, Eun-Kyung;Sim, Donggyu
    • ETRI Journal
    • /
    • 제39권3호
    • /
    • pp.301-309
    • /
    • 2017
  • In this paper, we propose a parallelization method for a High Efficiency Video Coding (HEVC) deblocking filter with transform unit (TU) split information. HEVC employs a deblocking filter to boost perceptual quality and coding efficiency. The deblocking filter was designed for data-level parallelism. In this paper, we demonstrate a method of distributing equal workloads to all cores or threads by anticipating the deblocking filter complexity based on the coding unit depth and TU split information. We determined that the average time saving of our proposed deblocking filter parallelization method has a speed-up factor that is 2% better than that of the uniformly distributed parallel deblocking filter, and 6% better than that of coding tree unit row distribution parallelism. In addition, we determined that the speed-up factor of our proposed deblocking filter parallelization method, in terms of percentage run-time, is up to 3.1 compared to the run-time of the HEVC test model 12.0 deblocking filter with a sequential implementation.

High Noise Density Median Filter Method for Denoising Cancer Images Using Image Processing Techniques

  • Priyadharsini.M, Suriya;Sathiaseelan, J.G.R
    • International Journal of Computer Science & Network Security
    • /
    • 제22권11호
    • /
    • pp.308-318
    • /
    • 2022
  • Noise is a serious issue. While sending images via electronic communication, Impulse noise, which is created by unsteady voltage, is one of the most common noises in digital communication. During the acquisition process, pictures were collected. It is possible to obtain accurate diagnosis images by removing these noises without affecting the edges and tiny features. The New Average High Noise Density Median Filter. (HNDMF) was proposed in this paper, and it operates in two steps for each pixel. Filter can decide whether the test pixels is degraded by SPN. In the first stage, a detector identifies corrupted pixels, in the second stage, an algorithm replaced by noise free processed pixel, the New average suggested Filter produced for this window. The paper examines the performance of Gaussian Filter (GF), Adaptive Median Filter (AMF), and PHDNF. In this paper the comparison of known image denoising is discussed and a new decision based weighted median filter used to remove impulse noise. Using Mean Square Error (MSE), Peak Signal to Noise Ratio (PSNR), and Structure Similarity Index Method (SSIM) metrics, the paper examines the performance of Gaussian Filter (GF), Adaptive Median Filter (AMF), and PHDNF. A detailed simulation process is performed to ensure the betterment of the presented model on the Mini-MIAS dataset. The obtained experimental values stated that the HNDMF model has reached to a better performance with the maximum picture quality. images affected by various amounts of pretend salt and paper noise, as well as speckle noise, are calculated and provided as experimental results. According to quality metrics, the HNDMF Method produces a superior result than the existing filter method. Accurately detect and replace salt and pepper noise pixel values with mean and median value in images. The proposed method is to improve the median filter with a significant change.