• Title/Summary/Keyword: Filling Test

Search Result 652, Processing Time 0.027 seconds

Deformation process and prediction of filling gangue: A case study in China

  • Wang, Changxiang;Lu, Yao;Li, Yangyang;Zhang, Buchu;Liang, Yanbo
    • Geomechanics and Engineering
    • /
    • v.18 no.4
    • /
    • pp.417-426
    • /
    • 2019
  • Gangue filling in the goaf is an effective measure to control the surface subsidence. However, due to the obvious deformation of gangue compression, the filling effect deserves to be further studied. To this end, the deformation of coal gangue filling in the goaf is analyzed by theoretical analysis, large-scale crushed rock compression test, and field investigation. Through the compression test of crushed rock, the deformation behaviour characteristics and energy dissipation characteristics is obtained and analysed. The influencing factors of gangue filling and predicted amount of main deformation are summarized. Besides, the predicted equation and filling subsidence coefficients of gangue are obtained. The gangue filling effect was monitored by the movement observation of surface rock. Gangue filling can support the roof of the goaf, effectively control the surface subsidence with little influence on the ground villages. The premeter and equations of the main deformation in the gangue filling are verified, and the subsidence coefficient is further reduced by adding cemented material or fine sand. This paper provides a practical and theoretical reference for further development of gangue filling.

The Development of the Hydrophobic - Low Viscosity Filling Material for the Surface Treatment for Pavement Preventive Maintenance (예방적 유지보수를 위한 소수성 저점도 AP 표면처리재 개발)

  • Choi, Jun Seong;Kim, Jo Sun
    • International Journal of Highway Engineering
    • /
    • v.16 no.2
    • /
    • pp.35-41
    • /
    • 2014
  • PURPOSES : Surface treatment is a favorable method in the pavement preventive maintenance. This study (Part I) aimed to develop the low viscosity filling material for waterproof characteristics and high penetrable and weather resistance, and a series of companion study (Part II) presents the coating characteristics and performance analysis using field and lab tests. METHODS : Hydrophobic characteristics of the advanced surface treatment material are observed and measured the filling depth and the permeability for sand and asphalt pavement specimen using the water absorption test and permeability test, X-RAY CT test. Color difference for the weather resistance using ultraviolet ray accelerated weathering test is compared with asphalt pavement specimens. RESULTS : The developed material shows the decreased water absorption and increased impermeable effect because of the hydrophobic characteristics. It is found that the filling depth is about 6mm and weather resistance is better than asphalt pavement specimen. CONCLUSIONS : The advanced hydrophobic - low viscosity filling treatment material is developed in this study (Part I) to improve the waterproof characteristics and high filling capacity and weather resistance for the pavement preventive maintenance.

Micro-computed tomographic evaluation of the flow and filling ability of endodontic materials using different test models

  • Torres, Fernanda Ferrari Esteves;Guerreiro-Tanomaru, Juliane Maria;Chavez-Andrade, Gisselle Moraima;Pinto, Jader Camilo;Berbert, Fabio Luiz Camargo Villela;Tanomaru-Filho, Mario
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.2
    • /
    • pp.11.1-11.9
    • /
    • 2020
  • Objectives: This study compared the flow and filling of several retrograde filling materials using new different test models. Materials and Methods: Glass plates were manufactured with a central cavity and 4 grooves in the horizontal and vertical directions. Grooves with the dimensions used in the previous study (1 × 1 × 2 mm; length, width, and height respectively) were compared with grooves measuring 1 × 1 × 1 and 1 × 2 × 1 mm. Biodentine, intermediate restorative material (IRM), and mineral trioxide aggregate (MTA) were evaluated. Each material was placed in the central cavity, and then another glass plate and a metal weight were placed over the cement. The glass plate/material set was scanned using micro-computed tomography. Flow was calculated by linear measurements in the grooves. Central filling was calculated in the central cavity (㎣) and lateral filling was measured up to 2 mm from the central cavity. Results: Biodentine presented the least flow and better filling than IRM when evaluated in the 1 × 1 × 2 model. In a comparison of the test models, MTA had the most flow in the 1 × 1 × 2 model. All materials had lower lateral filling when the 1 × 1 × 2 model was used. Conclusions: Flow and filling were affected by the size of the test models. Higher grooves and materials with greater flow resulted in lower filling capacity. The test model measuring 1 × 1 × 2 mm showed a better ability to differentiate among the materials.

A Study on the Model Test for Pneumatic Mine-Filling (공압식 갱내충전을 위한 모형실험 연구)

  • Yang, In-Jae;Shin, Dong-Choon;Yoon, Byung-Sik;Mok, Jin-Ho;Kim, Hak-Sung;Lee, Sang-Eun
    • Tunnel and Underground Space
    • /
    • v.24 no.6
    • /
    • pp.449-463
    • /
    • 2014
  • There are many case studies and application cases in abandoned mines for hydraulic filling method filled by slurry or paste form, but research on the pneumatic filling is not applied in Korea. The damage of steel pipe is occurred by wear due to the flow of filling material in the bent area of steel pipe in traditional pneumatic filling method. In this study, the new pneumatic filling method was developed using a newly devised improved nozzle to improve the above problem. The model test for mine filling was performed in the laboratory for the simulated accessible or inaccessible mine cavities, and the filling efficiency by the results obtained from the test was calculated. The filling efficiency was analyzed from the variation of outlet angle, feed rate and grain size of sand in model test of simulated accessible mine cavity. The superiority of improved pneumatic filling method was proved through the analysis of filling efficiency by the results obtained from each model tests of gravitational, traditional, and improved filling method in simulated inaccessible mine cavity.

Design of Kerosene Filling System of Propulsion System Test Complex (PSTC) for KSLV-II (한국형발사체 추진기관시스템 시험설비 연료공급시스템 설계)

  • Choi, Bongsu;Kim, Yongwook;Lee, Janghwan;Cho, Kiejoo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1200-1203
    • /
    • 2017
  • Propulsion system test complex (PSTC) is designed to verify propulsion system of KSLV-II. It is composed of hydraulic and pneumatic system, test stand system, control/measurement system, and flame deflector and safety system. In this study, kerosene filling system of hydraulic and pneumatic system is introduced. It performs store and chilling of kerosene, chilling and purging of filling line, and filling and retrieval of the kerosene. The kerosene supply requirements of 1, 2 and 3 stages of KSLV-II are considered in design process.

  • PDF

Analysis of Internal Overpressure by Pipe Cross-Sectional Area Ratio and Filling Rate in the Hydraulic Test of Shipboard Tank (수압시험 시 관 단면적 비 및 충수 속도별 탱크 내부 과압 발생에 관한 해석)

  • Geun-Gon Kim;Tak-Kee Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.6
    • /
    • pp.460-472
    • /
    • 2023
  • This study was conducted based on the case of an accident (excessive deformation) that occurred during the hydraulic test of a shipboard tank manufactured in accordance with the design regulations. Over-pressure phenomenon was noted as the main cause of accidents in the process of testing tanks without physical damage, which can be found in external factors such as cross-sectional difference between inlet pipe and air pipe and higher water filling rate than the recommended one. The main goal of this paper is to establish a safe water filling rate according to the range of sectional area ratio(SAR) reduced below the regulations for each test situation. The simulation was conducted in accordance with the hydraulic test procedure specified in the Ship Safety Act, and the main situation was divided into two types: filling the tank with water and increasing the water head to the test pressure. The structural safety evaluation of the pressure generated inside the tank and the effect on the structure during the test was reviewed according to the SAR range. Based on the results, guidelines for the optimal filling rate applicable according to SAR during the hydraulic test were presented for the shipboard tanks used in this study.

Study on Filling Capacity of Self-Consolidating Concrete for Modular LNG Storage Tank (모듈형 LNG 저장탱크용 자기 충전 콘크리트의 충전 성능평가 실용화 연구)

  • Lee, Dong Kyu;Lee, Keon Woo;Choi, Myoung Sung
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.6
    • /
    • pp.50-57
    • /
    • 2018
  • The purpose of this study is to evaluate the practical application of the self consolidating concrete for the steel concrete pannel (SCP) in module LNG storage tank proposed in the previous research. We evaluated the physical properties and filling performance of developed concrete for the SCP module. First, a slump flow test was conducted to evaluate the performance of the proposed guidelines for the filling test. As a result, all of the concrete used showed satisfactory performance. Based on the results of the previous study, it was found that the reliability of the required time measured by the $T_{500}$ test and the rheometer results measured before and after pumping was 0.94 which means the separation and blocking should not occur. The L-box test and the U-box test were conducted before and after pumping. All of the guidelines suggested showed satisfactory performance. SCP module for LNG storage tanks was fabricated on actual size scale to evaluate the practical application at the final site. As a result, it was confirmed that satisfactory filling performance was obtained in all the specimens.

Comparison of Results for Filling Operation of Liquid Oxygen Filling System in KSLV-I Flight Test and Critical Design Results in KSLV-II Launch Complex for Validation (한국형발사체 발사대시스템 산화제공급계 충전 운용 설계의 검증을 위한 나로호 비행시험 실증 자료 분석)

  • Seo, Mansu;Lee, Jae Jun;Hong, Il-gu;Kang, Sunil
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.14-20
    • /
    • 2017
  • In this paper, KSLV-I flight test data and critical design results of filling operation for liquid oxygen filling system are compared to validate the reliability of the critical design modeling. Applying the filling and operation conditions on the critical design modeling, comparison of major flow rates and pressure values between test data and calculation results are conducted.

  • PDF

Experimental Study of Sloshing Load on LNG Tanks for Unrestricted Filling Operation

  • Kim, Sang-Yeob;Kim, Yonghwan;Park, Jong-Jin;Kim, Booki
    • Journal of Advanced Research in Ocean Engineering
    • /
    • v.3 no.1
    • /
    • pp.41-52
    • /
    • 2017
  • This paper presents a numerical and experimental study of sloshing loads on liquefied natural gas (LNG) vessels. Conventional LNG carriers with membrane-type cargo systems have filling restrictions from 10% to 70% of tank height. The main reason for such restrictions is high sloshing loads around these filling depths. However, intermediate filling depths cannot be avoided for most LNG vessels except the LNG carrier. This study attempted to design a membrane-type LNG tank with a modified lower-chamfer shape that allows all filling operations. First, numerical sloshing analysis was carried out to find an efficient height of the lower-chamfer that can reduce sloshing pressure at partially filled conditions. The numerical sloshing analysis program SHI-SLOSH was used for numerical simulation; this program is based on SOLA-VOF. The effectiveness of the newly designed tanks was validated by 1:50-scale three-dimensional tank tests. A total of three different tanks were tested: a conventional tank and two modified tanks. As test conditions, various filling depths and wave periods were considered, and the same test conditions were applied to the three tanks. During the test, slosh-induced dynamic pressures were measured around the corners of the tank wall. The measured pressure data were post-processed and the pressures of the three different tanks were statistically compared in several ways. Experimental results show that the modified tanks were quite effective in reducing sloshing loads at low filling conditions. This study demonstrated the possibility of all filling operations for LNG cargo containment systems.

Oxidizer Filling Algorithm of Propulsion System Test Complex(PSTC) for KSLV-II (한국형발사체 추진기관시스템 시험설비(PSTC) 산화제 공급 알고리즘 소개)

  • Lee, Janghwan;Kim, Dongki;Lee, Jungho;Kim, Yongwook;Cho, Kiejoo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1180-1183
    • /
    • 2017
  • The Propulsion System Test Complex (PSTC) is constructed for developing KSLV-II in the Naro space center. The KSLV-II uses LOX for oxidizer and oxidizer filling algorithm is developed for supplying oxidizer to KSLV-II. This paper introduces oxidizer filling algorithm.

  • PDF