• Title/Summary/Keyword: Filling Process

Search Result 896, Processing Time 0.027 seconds

Hydrothermal Alteration and Mineralogy of Alunite and Kaolinite in the Ogmae Deposit, Southwest Jeonnam (전남(全南) 옥매산광상(玉埋山鑛床)의 열수변질작용(熱水變質作用) 및 광석광물(鑛石鑛物)에 대한 광물학적(鑛物學的) 연구)

  • Kim, Young Hee;Moon, Hi-Soo;Kim, Jong Hwan;You, Jang Han;Kim, In Joon
    • Economic and Environmental Geology
    • /
    • v.23 no.3
    • /
    • pp.287-308
    • /
    • 1990
  • The Ogmae alunite-kaolinite deposit occurs in acidic tuff, the Hwangsan Tuff, of upper Crataceous age in the Haenam volcanic field, SW Jeonnam. This deposit characterized by advanced argillic alteration formed $71.8{\pm}2.8{\sim}73.9{\pm}2.8$ Ma ago in very shallow depth environment with acid-sulfate solution. Wallrock alteration can be classified into four zones from the center to the margin of the deposit: alunite, kaolinite, illite, and silicified zone. The mineral assemblage in the alunite zone, ore zone, is alunite-quartz-pyritekaolinite. Consideration of stability relation of these minerals suggests that the maximum alteration temperature is estimated at about $250^{\circ}C$ with solution pH of 3 or below assuming that pressure does not exceed 0.3 Kb. Alunite occurs as two different types; replacement and vein-type deposit. The former one consists of fine grained alunite and the later one coarse grained and relatively pure alunite that formed by open space filling. Isomorphous substitution of Na for K in these two types of alunites range 0 to 40 %, indicating that Na/K ratio in the solution is spontaneously changed during the alteration process. Alunite which has higher Na substitution probably formed in an earlier stage while the solution sustain high Na/K ratio. K-Ar age of alunites indicate that the replacement alunite formed earlier($73.9{\pm}2.8Ma$) than the vein-type alunite($71.8{\pm}2.8Ma$). The ${\delta}^{34}S$ value of pyrite and alunite indicate that those minerals formed at isotopically nonequillibrium state. The ${\delta}^{16}O$ and ${\delta}D$ values, of kaolintics 5.0 to 9.0‰ and -54 to -99‰, respectively, indicate that those are formed by hydrothermal solution having magmatic origin which have been diluted by low ${\delta}D$ meteoric water.

  • PDF

A Study on the Liberation Characteristics of Waste Concrete for Production of High Quality Recycled Aggregate (고품질(高品質) 순환골재(循環骨材) 생산(生産)을 위한 폐콘크리트의 단체분리(單體分離) 특성(特性) 연구(硏究))

  • Kim, Kwan-Ho;Mun, Myoung-Wook;Cho, Hee-Chan;Ahn, Ji-Whan
    • Resources Recycling
    • /
    • v.19 no.3
    • /
    • pp.52-61
    • /
    • 2010
  • In general, the waste concrete is simply crushed and reused as a recycled aggregate at a low value application such as back filling material. It because that the quality of recycled aggregate is lower than one of natural aggregate due to the insufficient liberation of aggregate and cement mortar. So in this study, the liberation characteristics of liberation of aggregate and cement mortar is analyzed to investigate the limitation of conventional crushing stage at waste concrete processing circuit. In this process, thermal treatment method is evaluated for the enhancement of liberation. From test results, the preferential breakage along the grain boundary is not accomplished by the conventional crushers. It leads a low quality of recycled aggregate and a fracture of aggregate. To solve these problems, gentle breakage is used as a breakage mechanism to induce preferential breakage along the grain boundary. The recycled aggregate produced from the free fall test, which adopts a gentle breakage, shows a better liberation characteristics and a higher quality.

Improved Radiochemical Yields, Reliability and Improvement of Domestic $^{18}F$-FDG Auto Synthesizer (국산 $^{18}F$-FDG Auto Sysnthesizer의 수율 향상과 성능 개선)

  • Park, Jun-Hyung;Im, Ki-Seop;Lee, Hong-Jin;Jeong, Kyung-Il;Lee, Byung-Chul;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.147-151
    • /
    • 2009
  • Purpose: 2-[$^{18}F$]Fluoro-2-deoxy-D-glucose ([$^{18}F$]FDG) particularly plays as a important role in Positron Emission Tomography (PET) imaging in nuclear medicine. Domestic [$^{18}F$]FDG auto synthesizers are installed in Seoul National University Bundang Hospital (SNUBH) at June 2008, these modules were known that it's synthetic yields were guaranteed in average $45{\pm}5%$ so far. To improve yields and convenience of domestic [$^{18}F$]FDG auto synthesizer, numerous trials in reaction time, base concentration, pressure and temperature were performed to increase [$^{18}F$]FDG yields. Materials and Methods: Several synthetic factors (temperature, time and pressure) and shortcoming were corrected based on many evaporation test. Syringe dispensing of tetra-butylammonium bicarbonate (TBAB) was replaced with micro pipette to prepare tetrabutyl ammonium fluoride salt ([$^{18}F$]TBAF). Troublesome refill of liquid nitrogen every 2 hours which was used to protect vacuum system was changed to charcoal cartridge, base guard filter. To monitor the volume of delivered $[^{18}O]OH_2$ from cyclotron by surveillance camera, we set up the volumetric vial on the cover of the module. In addition to, the recovery vial was added in [$^{18}F$]FDG production system to recover [$^{18}F$]FDG loss due to the leak of valve ($V_{13,14}$) in [$^{18}F$]FDG purification process. Results: When we used micro pipette for adding TBAB ($30\;{\mu}L$ in 12% $H_2O$ in acetonitrile), this quantitative dispensation has enabled to improve $5.5{\pm}1.7%$ residual fluorine-18 activity in fluorine separation cartridge compared to syringe adding. Besides, the synthetic yields of [$^{18}F$]FDG has increased $58{\pm}2.6%$ (n=19), $58{\pm}2.9%$ (n=14), $60%{\pm}2.5%$ (n=17) for 3 months. The life cycle of charcoal cartridge and base vacuum was 3 months prior to filling liquid nitrogen every 2 hours and additional side separator can prevent pump corrosion by organic solvent. After setting of volumetric indicator vial, the operator can easily monitor the total volume of irradiated $[^{18}O]OH_2$ from cyclotron. The recovery vial can be used for the stabilizer when an irregular [$^{18}F$]FDG loss was generated by the leak of valves ($V_{13,14}$). Conclusions: We has optimized appropriate synthetic conditions (temperature, time, pressure) in domestic [$^{18}F$]FDG auto synthesizer. In addition to, the remodeling with several accessories improve yields of domestic [$^{18}F$]FDG auto synthesizer with reliable reproducibility.

  • PDF

Development of a Hospital Service-based Costing System and Its Application (병원서비스별 원가분석모형의 개발과 적용)

  • 박하영
    • Health Policy and Management
    • /
    • v.5 no.2
    • /
    • pp.35-69
    • /
    • 1995
  • The managerial environment of hospitals in Korea characterized by low levels of medical insurance fees is worsening by increasing government regulations as to the utilization of medical services, rising costs of labor, material, and medical equipments, growing patient expectations concerning the quality of services, and escalating competitions among large hospitals in the market. Hospitals should seek for their survival strategies in this harsh environment and they should have information about costs of their products in doing so. However, it has not been available due to the complexity of the production process of hospital services. The objectives of this study were to develop a service-based cost accounting model and to apply the developed model to a study hospital to obtain cost information of hospital services. A model commonly used for the job-order product cost accounting in the manufacturing industry was modified for the use in hospitals in Korea. Actual costs, instead of standard costs, incurred to produce a unit of services during a given period of time were estimated in the model. Data required to implement the model included financial information, statistics for the allocation of supportive cost center costs to final cost centers, statistics for the allocation of final cost center costs to services, and the volume of each services charged to patients during a study period. The model was executed using data of a university teaching hospital located in Seoul for the fiscal year 1992. Data for financial information, allocation statistics fo supportive service costs, and the volume of services, most of them in electronic form, were available to the study. Data for allocation statistics of final cost center costs were collected in the study. There were 15 types of evaluation and management service, 2, 923 types of technical service, and 2, 608 types of drug and material service charged to patients in the study hospital during the fiscal year 1992. Labor costs of each of seven types of pesonnel, material costs of 611 types of drugs and materials, and depreciation costs of 212 types of medical equipments, miscellaneous costs, and indirect costs incurred in producing a unit of each services were estimated. Medical insurance fees for basic services such as evaluation and management of inpatients and outpatients, injection, and filling prescriptions, and for operating procedures were found to be set lower than costs. Infrequent services which use expensive medical equipments showed negative revenuse as well. On the other hand, fees for services not covered by the insurance such as CT, MRI and Sonogram, and for laboratory tests were higher than costs. This study has a significance in making it possible for a hospital to obtain cost information for all types of services which produced income based on all types of expenses incurred during a given period of time. This information can assist the management of a hospital in finding an effective cost reduction strategy, an efficient service-mix strategy under a given fee structure, and an optimum strategy for within-hospital resource allocations.

  • PDF

Development of Key Technologies for Large Area Forming of Micro Pattern (대면적 미세 성형공정 원천기술 개발)

  • Choi, Doo-Sun;Yoo, Yeong-Eun;Yoon, Jae-Sung;Je, Tae-Jin;Park, Si-Hwan;Lee, Woo-Il;Kim, Bong-Gi;Jeong, Eun-Jeong;Kim, Jin-Sang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.7
    • /
    • pp.777-782
    • /
    • 2011
  • Micro features on the surface are well-known to have significant effects on optical or mechanical properties such as the optical interference, reflectance at the surface, contact angle, interfacial friction, etc. These surface micro features are increasingly employed to enhance the functionality of the applications in various application areas such as optical components for LCD or solar panel. Diverse surface features have been proposed and some of them are showing excellent efficiency or functionality, especially in optical applications. Most applications employing the micro features need manufacturing process for mass production and the injection molding and roll-to-roll forming, which are typical processes for mass production adopting polymeric materials, may be also preferred for micro patterned plastic product. Since the functionality or efficiency of the surface structures generally depends on the shape and the size of the structure itself or the array of the structures on the surface, it would be very important to replicate the features very precisely as being designed during the molding the micro pattern applications. In this paper, a series of research activities is introduced for roll-to-roll forming of micro patterned film including filling of patterns with UV curable resin, demolding of surface structures from the roll tool, control of surface energy and cure shrinkage of resin and dispose time and intensity of the UV light for curing of UV curable resin.

Characterization of Surface Deterioration for Stone Property around the Hyeonleung (Royal Tomb of Joseon Dynasty) in Guri, Korea (구리 현릉 능상석물의 표면 손상특성 평가)

  • Oh, Jeong Hyun;Kim, Sa Dug;Lee, Chan Hee;Lee, Tae Jong
    • Journal of Conservation Science
    • /
    • v.32 no.3
    • /
    • pp.353-364
    • /
    • 2016
  • The materials of sculptured stone property around the Hyeonleung Royal Tomb in Guri consist mainly of high weathered of granitic rocks with magnetite-series. Deterioration characteristics occurred highly with microorganism, soil inflow and black contaminants at the burial mound zone. As a result of deterioration evaluation, stone surface around the burial mound zone show serious comprehensive damage of soil inflow (50.5%) and lichen coverage (47.6%) which are the major damaging factors, and there are about 8.6% of biological growth noticeably in the north side. Surface contaminants and the discoloration had the complex causes. Gypsum occurred between joints of stones and the major contaminant type, darkening which was analyzed organic bodies caused discoloration. From result of ultrasonic velocity measurements, there are mean value of 2,195 m/s with highly weathered (HW) grade. Most of the stone properties showed 4 to 5 weathered grade. Therefore, it turned out that sculpture stone properties require conservation treatments. To remove soil accelerating damage factors and lichen occupying high percents, the cleaning process is necessary and consolidation, rejoining and filling are needed as well. Also, consideration on removing conservation materials containing Ca and e fflorescence is required and retreatments need to be considered.

Intraaneurysmal Blood Flow Changes for the Different Coil Locations (코일 위치에 따른 동맥류 내부 혈류유동의 변화)

  • 이계한;정우원
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.295-300
    • /
    • 2004
  • Coil embolization technique has been used recently to treat cerebral aneurysms. When a giant or a multilobular aneurysm are treated by roils, filling an aneurysm sac completely with coils is difficult and partial blocking of an aneurysm sac is inevitable. Blood flow characteristics, which nay affect the embolization process of an aneurysm sac, are changed by the locations of coils for the Partially blocked aneurysms. Blood flow fields are also influenced by the geometry of a parent vessel. In order to suggest the coil locations effective for aneurysm embolization, the blood flow fields of lateral aneurysm models were analyzed for the different coil locations and parent vessel geometries. Three dimensional pulsatile flow fields are analyzed by numerical methods considering non-Newtonian viscosity characteristics of blood. Flow rate into the aneurysm sac (inflow rate) and wall shear stress, which are suspected as flow dynamic factors influencing aneurysm embolization, are also calculated. Inflow rates were smaller and the low wall shear stress zones were larger in the neck blocked models compared to the dome blocked models. Smaller inflow and larger low wall shear stress zones in the distal neck blocked model imply that the distal neck should be the effective coil locations for aneurysm embolization.

Hydrogen Compressor Cycle Analysis for the Operating Pressure of 50 MPa and High Charging Capacity (50 MPa급 대용량 수소압축기 사이클 해석)

  • Song, Byung-Hee;Myoung, No-Seuk;Jang, Seon-Jun;Kwon, Jeong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.66-73
    • /
    • 2020
  • In the hydrogen compression cycle, which is currently being developed, hydrogen is compressed to a very high pressure using a compressor, and then stored and used in a high-pressure vessel. This shows that an increase in the temperature of hydrogen in the vessel due to a pressure rise during the filling process and the pressure fatigue due to the repeated cycle may cause problems in the reliability of the vessel. In this paper, for the entire processes in a 50 MPa hydrogen compression system, theoretical and numerical methods were conducted to analyze the following: the temperature increase of hydrogen in the vessel and the time required to reach thermal equilibrium with the surroundings, the change in temperature of hydrogen passing through the pressure reducing valve, and the required capacity of the heat exchanger for cooling the vessel. The results will be useful for the design and construction of hydrogen compression systems, such as hydrogen charging stations.

A Study on Characteristics of Residue in Liquefied Petroleum Gas using Automotive Fuel (자동차용 액화석유가스(LPG) 잔류물질의 특성 연구)

  • Jang, Yoon-mi;Park, Tae-seong;Kang, Hyung-kyu;Yim, Eui Soon;Lee, Jung-min;Na, Byung-gi
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.816-825
    • /
    • 2018
  • Recently, it was emerged to need the necessity of LPG residues management due to the finding some substances such as rust. This study is performed to investigate the characteristics of LPG residues in the production and distribution stage of LPG. For the qualitative analysis of LPG residues, it was operated to be set up the analysis conditions(the flow rate, etc) of GC-MS and was performed to analyze the component of LPG residues. From the analysis result using GC-MS, it was shown that the component of LPG residues was turned out the plasticizer to be used in the rubber manufacturing process. The inorganic components of LPG residues were analyzed using ICP-OES. At the results of inorganic analysis, it was shown that the Si element was detected, which was presumably derived from defoamers used mainly in the LPG production. Also, the P and Zn element, which are estimated to be components of grease additives used for filling facilities, were also partially detected. No trace of rusting was detected in the LPG residues in the production and distribution stages analyzed in this study. But, as plasticizers and grease additives can affect to the LPG fuel system in vehicles, it will be necessary to use the proper quality of rubber and to expand the use of low boiling grease additives.

Fabrication and transcription estimation of prismless LGP for cellular phone using E-Mold technology (전열가열방식을 이용한 휴대전화용 복합기능 도광판 제작 및 전사성 평가)

  • Kim, Young-Kyun;Chung, Jae-Youp;Kim, Dong-Hak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.186-193
    • /
    • 2009
  • In this paper, we adopted E-MOLD patent technology in order to fabricate Prismless LGP(Light Guide Panel) fur cellular phone and estimate the transcription of injection-molded parts. Then, we manufactured the Ni stamper fur Prismless LGP using MEMS process. And the stamper was installed in the movable heated core which is the key part of a patented mold. Using this mold, we manufactured injection-molded plastic LGP parts with different mold temperatures so that we investigate effect of the temperature on the transcription of the parts. The CAE analysis was also conducted in order to compare with the experimental results. The transcription of LGP parts with various mold temperature displayed $100^{\circ}C$(25.0nm), $140^{\circ}C$(48.4nm), $180^{\circ}C$(52.1nm) and when compared with stamper(521Inm), transcription was superior at $180^{\circ}C$. According to the CAE results, moldability was improved as mold temperature ($50^{\circ}C{\sim}180^{\circ}C$) increased, but when filling time($1{\sim}2sec$) increases, it decreased at $160^{\circ}C$. And transcription and moldability were improved markedly at glass transition temperature($140^{\circ}C$).