• 제목/요약/키워드: Filling Material

검색결과 736건 처리시간 0.024초

수치해석에 의한 복개터널 라이닝의 변위거동 (Displacement Behaviour of Cut-and-Cover Tunnel Lining by Numerical Analysis)

  • 이명욱;박병수;전용배;유남재
    • 산업기술연구
    • /
    • 제24권A호
    • /
    • pp.227-238
    • /
    • 2004
  • This paper is results of experimental and nunerical works on the behavior of the cut-and-cover tunnel. Centrifuge model tests were performed to simulate the behavior of the cut-and-cover tunnels having cross sections of national road and subway tunnels. Model experiments were carried out with changing the cut slope and the slope of filling ground surface. Displacements of tunnel lining resulted from artificially accelerated gravitational force up to 40g of covered material used in model tests, were measured during centrifuge model tests. In model tests, Jumunjin Standard Sand with the relative density of 80 % and the zinc plates were used for the covered material and the flexible tunnel lining, respectively. Basic soil property tests were performed to obtain it's the property of Jumumjin Standard Sand. Shear strength parameters of Jumunjin Standard Sand were obtained by performing the triaxial compression tests. Direct shear tests were also carried out to find the mechanical properties of the interface between the lining and the covered material. Numerical analysis with the commercially available program of FLAC were performed to compare with results of centrifuge model experiment In numerical modelling. Mohr-Coulomb elasto-plastic constitutive model was used to simulaye the behavoor of Jumunjin Standard Sand and the interface element between the lining and the covered material was implemented to simulate the interaction between them. Compared results between model tests and numerical estimation with respect to displacement of the lining showed in good agreements.

  • PDF

가역성을 갖는 도자기 복원용 무황변 우레탄 수지의 개발과 이를 이용한 도자기의 복원 (The Development of the Unfading Urethane Polymer Based on Reversible Properties for Ceramics and Restoration with This Urethane Product)

  • 한원식;박기정;임성진;이영훈;홍태기;위광철
    • 보존과학회지
    • /
    • 제26권2호
    • /
    • pp.183-190
    • /
    • 2010
  • 무황변 가역성 도자기 복원 재료를 위하여 우레탄을 제조하여 이용하였다. 이 저점도형 우레탄은 사용자가 강도 조절이 가능하도록 제조하였다. 이 우레탄 복원재는 매우 강한 접착 강도와 전단 강도를 나타내고 있으며, 그간 일반적으로 사용되어온 에폭시 복원재와 같은 충진성, 수축성, 도색성을 갖도록 제조되었다. 특히, 현재 일반적으로 사용되는 에폭시계 복원재의 문제점인 황변 현상과 비가역성 문제를 해결함으로서, 도자기의 복원의 항구성과 지속적인 안정성을 부여할 수 있을 것으로 보인다. 또 본 우래탄 복원재를 이용하여 도자기를 직접 적용 복원하였으며 복원 후, 이를 재 용해하여 복원제를 완벽히 제거하는 과정을 통하여 복원의 가역성도 보이고자 하였다.

압축 벤토나이트 완충재의 온도에 따른 열전도도 평가 (Thermal Conductivity Evaluation of Compacted Bentonite Buffers Considering Temperature Variations)

  • 윤석;박승훈;김민섭;김건영;이승래
    • 방사성폐기물학회지
    • /
    • 제18권1호
    • /
    • pp.43-49
    • /
    • 2020
  • 고준위폐기물을 심지층에 처분하기 위한 공학적방벽의 구성 요소로는 처분용기, 완충재, 뒷채움재 등이 있다. 이 중 완충재는 처분용기와 근계암반 사이의 빈 공간에 설치되는 물질로써, 주변 지하수로부터 처분용기를 보호하며 방사성 핵종의 유출을 저지하는 등의 역할을 한다. 또한 처분용기에서 발생하는 고온의 열량은 완충재로 직접 전파되기에 완충재의 열전도도는 처분시스템의 안전성 평가에 있어 매우 중요하다고 할 수 있다. 따라서 본 연구에서는 국내 경주산 압축 벤토나이트 완충재의 열전도도 특성을 규명하였으며 실제 처분용기에서 발생되는 고온의 특성을 반영하여 상온에서 80~90℃까지의 범위에서 압축 벤토나이트의 열전도도를 측정하였다. 온도증가에 따라 압축 벤토나이트의 열전도도는 5~20% 가량 증가하였으며 초기 포화도가 클수록 열전도도 증가는 더 크게 나타났다.

Sandwich 술식에 제V급 와동의 미세 변연누출에 미치는 영향에 대한 연구 (AN EXPERIMENTAL STUDY FOR THE EFFECT OF SANDWICH TECHNIQUE ON MICROLEAKAGE IN CLASS V CAVITY)

  • 신창승;이정석
    • Restorative Dentistry and Endodontics
    • /
    • 제18권2호
    • /
    • pp.447-462
    • /
    • 1993
  • To evaluate the marginal leakage in Class V cavity this study has been undertaken to compare the sandwich technique with the conventional method, and find out the effect of lining material, lining method, and polishing time on sandwich technique. Ninty extracted teeth were divided into eight test groups and a control group, and were prepared with a buccal Class V cavity. Four test groups were lined with Dentin Cement whereas the other four test groups were lined with Vitrabond. Half of the either group were lined 0.5mm short of the carvosurface margin and the rest were lined completely to the carvosurface margin. The four subgroups were further divided into specimens which were polished immediately and 24 hours after resin filling. The polished specimens were immersed in $37^{\circ}C$, 0.5% methylene blue solution for 24 hous after thermocycling at $5^{\circ}C$ and $55^{\circ}C$, 200 times and buccolingually sectioned. The sectioned specimens were examined dye penetration under the light microscope. The following results were obtained, 1. At the enamel margin, the conventional method showed a lower microleakage than the sandwich technique. The difference between the control and Vitrabond group was statistically significant(P<0.05), but no difference between the control and Dentin Cement group, and between the lining materials was observed. 2. At the dentinal margin, the sandwich technique showed a significant lower amount of microleakage (P<0.05), but there was no significant difference between the lining materials. 3. Regardless of the lining material, lining method, and polishing time used, values of microleakage were significantly higher at the dentinal margin compared to the enamel margin(P<0.05). 4. In specimens till the cavosurface margin, microleakage at the dentinal margin was less with the light-cured base than with the chemically-cured base, but there was no siginificantly difference between the lining materials regarding the lining method and polishing time. 5. The lining material, lining method, and polishing time did not affect the amount of micro leakage in the sandwich technique(P<0.05).

  • PDF

광중합형 glass ionomer cement를 포함한 수종 역충전재의 세포주와 검사법에 따른 독성 효과 (CYTOTOXIC EFFECT OF RETROGRADE FILLING MATERIALS INCLUDING GLASS IONMER CEMENT ACCORDING TO CELL LINES AND ASSAY METHODS)

  • 임미경;구대회
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.403-424
    • /
    • 1996
  • Cell culture methods have been used to assess the cytotoxicity of dental materials. Different paramaters are used to monitor cytotoxic effects. But it is difficult to compare each investigator's results with different methods. The objective of this study was to investigate cytotoxic effect of several retrograde filling materials according to cell lines and assay methods. Cytotoxicity of Bestalloy (Dogmyung, Korea), Prisma APH(Densply International Inc., U.S.A.), Clearfil FII (Kuraray Co., Japan), Fuji II (GC Co., Japan), Fuji II LC (GC Co., Japan) and IRM (Densply Co., U.S.A.) on L929, 3T3 and KB permanent cell lines was measured. Radiochromium, Lactate dehydrogenase (LDH) release method and colorimetric assays, namely neutral red (NR) and MTT were used. Each material was mixed according to the manufacturer's instruction. They were tested as solid and extracted state. Cell culture media were added to each mixed or solid materials then the solution was collected and used as extract solutions. Solid Fuji II showed mild cytotoxicity on three cell lines using radiochromium release method. There was no difference in cytotoxicity of extract solution group using radiochromium release method. In colorimetric assay immediate Fuji II group and all the IRM groups showed severe cytotoxic effect. Difference in cyctotoxicity was due to rather kinds of cell lines than assay methods. Solid Fuji II and IRM showed mild cytotoxicity on three cell lines. But extract solutions had different cytotoxic effect according to cell lines using LDH release assay. Light-cured glass ionomer had mild to moderate degree of cytotoxicity on three cell lines. Cytotoxicity was affected by specimen prepaton. Susceptibility of each cell ines were also affected by assay emthods. It was suggested that cytotoxicity study using only one cell line and/or assay method might not accurately reflect the real toxic nature of dental biomaterials.

  • PDF

Bending behavior of squared cutout nanobeams incorporating surface stress effects

  • Eltaher, Mohamed A;Abdelrahman, Alaa A.
    • Steel and Composite Structures
    • /
    • 제36권2호
    • /
    • pp.143-161
    • /
    • 2020
  • In nanosized structures as the surface area to the bulk volume ratio increases the classical continuum mechanics approaches fails to investigate the mechanical behavior of such structures. In perforated nanobeam structures, more decrease in the bulk volume is obtained due to perforation process thus nonclassical continuum approaches should be employed for reliable investigation of the mechanical behavior these structures. This article introduces an analytical methodology to investigate the size dependent, surface energy, and perforation impacts on the nonclassical bending behavior of regularly squared cutout nanobeam structures for the first time. To do this, geometrical model for both bulk and surface characteristics is developed for regularly squared perforated nanobeams. Based on the proposed geometrical model, the nonclassical Gurtin-Murdoch surface elasticity model is adopted and modified to incorporate the surface energy effects in perforated nanobeams. To investigate the effect of shear deformation associated with cutout process, both Euler-Bernoulli and Timoshenko beams theories are developed. Mathematical model for perforated nanobeam structure including surface energy effects are derived in comprehensive procedure and nonclassical boundary conditions are presented. Closed forms for the nonclassical bending and rotational displacements are derived for both theories considering all classical and nonclassical kinematics and kinetics boundary conditions. Additionally, both uniformly distributed and concentrated loads are considered. The developed methodology is verified and compared with the available results and an excellent agreement is noticed. Both classical and nonclassical bending profiles for both thin and thick perforated nanobeams are investigated. Numerical results are obtained to illustrate effects of beam filling ratio, the number of hole rows through the cross section, surface material characteristics, beam slenderness ratio as well as the boundary and loading conditions on the non-classical bending behavior of perforated nanobeams in the presence of surface effects. It is found that, the surface residual stress has more significant effect on the bending deflection compared with the corresponding effect of the surface elasticity, Es. The obtained results are supportive for the design, analysis and manufacturing of perforated nanobeams.

연마방법에 따른 복합레진의 활택도에 관한 연군 -Atomic Force Microscope를 이용한 연구 (A STUDY ON SURFACE ROUGHNESS OF COMPOSITE RESINS AFTER FINISHING AND POLISHING -an Atomic Force Microscope study)

  • 김형섭;우이형
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.719-741
    • /
    • 1997
  • This study was undertaken to compare by Atomic Force Microscope the effects of various finishing and polishing instruments on surface roughness of filling and veneering composite resins. Seven composite resins were studied : Silux Plus (3M Dental Products, U.S.A.), Charisma (Heraeus Kulzer, Germany), Prisma THP (L.D.Caulk, Dentsply, U.S.A.), Photoclearfil (Kuraray, Japan), Cesead (Kuraray, Japan), Thermoresin LC (GC, Japan), Artglass (Heraeus Kulzer, Germany). Samples were placed and polymerized in holes (2mm thick and 8.5mm in diameter) machined in Teflon mold under glass plate, ensuring excess of material and moulded to shape with polyester matrix strip. Except control group (Polyester matrix strip), all experimental groups were finished and polishied under manufacturer's instructions. The finishing and polishing procedure were : carbide bur (E.T carbide set 4159, Komet, Germany), diamond bur (composite resin polishing bur set, GC, Japan), aluminum-oxide disc (Sof-Lex Pop-On, 3M Dental Products, U.S.A.), diamond-particle disc (Dia-Finish, Renfert Germany), white stone bur & rubber point( composite finishing kit, EDENTA, Swiss), respectively. Each specimens were evaluated for the surface roughness with Atomic Force Microscope (AutoProbe CP, Park Scientific Instruments, U.S.A.) under contact mode and constant height mode. The results as follows : 1. Except Thermoresin LC, all experimental composite resin groups showed more rougher than control group after finishing and polishing(p<0.1). 2. A surface as smooth as control group was obtained by $Al_{2}O_{3}$ disc all filling composite resin groups except Charisma and all veneering composite resin groups except Thermoresin LC(p<0.05). 3. In case of Thermoresin LC, there were no statistically significant differences before and after finishing and polishing(p>0.1). 4. Carbide bur, diamond bur showed rough surfaces in all composite resin groups, so these were inappropriate for the final polishing instruments.

  • PDF

왕겨 연소기(燃燒機)를 이용(利用)한 온수(溫水)보일러 시스템 개발(開發) (I) -실험적(實驗的) 연구(硏究)- (Development of a Hot Water Boiler System with a Rice Hull Furnace)

  • 이용국;박승제;백풍기;노상하
    • Journal of Biosystems Engineering
    • /
    • 제12권4호
    • /
    • pp.31-43
    • /
    • 1987
  • This study was performed to develop a hot water boiler system with small scale automatic rice hull furnace for the multi-purpose use in the farm. For the experiment a prototype hot water boiler system with rice hull furnace was fabricated, which was equipped with automatic hull feeder, igniter and ash removal device. Optimum operational conditions of the prototype: system were analyzed. The results arc summarized as follows. 1. The temperature measured right above the burning surface should be higher than $500^{\circ}C$ combustion. 2. The top zone of the combustion chamber was the most suitable location of the thermocouple to pick up the control temperature for the automatic operation of the rice hull furnace. 3. The content of carbon monoxide in the flue gas was increased with the filling height of burning material but it was less than 0.3 percent in volume in this experiment. When the filling height was expressed as the ratio of rice hull feed rate to the volume of the combustion chamber above the burning surface, the optimum ratio was about $150kg/m^3-h$. 4. The combustion efficiency of the prototype was higher than 95 percent when the feed rate was 1.1 to 2.3 kg/h and moisture content of rice hull was 22.4 percent (w.b.) or less. 5. It was estimated that the optimum operational conditions of the system were 1.3 to 2.0 kg/h in feed rate, 70 to 100 percent in excess air and 500 to $510^{\circ}C$ in control temperature. 6. The efficiency of coil heal exchanger increased with a decrease in feed rate of rice hull. When the rice hull feed rates were 1.1, 1.7 and 2.3 kg/h, the efficiencies of coil heat exchanger were about 34, 30 and 25 percent and heat transfer rates were 5.7, 7.6 and 8.8 MJ/h, respectively. When the flat plate heat exchanger was used in addition to the coil heat exchanger, the efficiency of the heat exchanger system increased to 48 percent.

  • PDF

발포금속 제조를 위한 석고주형의 특성 (Properties of Plaster Mold for Open Cell Aluminum Foam)

  • 김기영;백남익
    • 한국주조공학회지
    • /
    • 제21권4호
    • /
    • pp.253-259
    • /
    • 2001
  • There are many methods to produce metal foams, which can be classified into three groups according to the state of the starting metal i.e. liquid or powder or solid. Three types of defects such as cell closing, cell deformation or breakdown and cell misrun are thought to be occurred when we make the open cell aluminum foams by precision casting. Filling ability of the mold slurry between preform is related with cell closing, mold collapsibility is related with cell deformation or breakdown, mold temperature and pouring pressure are related with cell misrun. These factors can be evaluated by measuring slurry fluidity, burnout strength and permeability of the mold. Properties of the plaster mold were evaluated to find optimum mold conditions for high quality open cell aluminum foam in this study. Permeability was almost zero independent of burnout conditions, however, crack initiation was found on the surface of all specimens one or two minutes after taking out from the furnace. Crack has grown and disappeared with time. This crack may facilitate the mold filling when molten metal is poured, because of the improved mold permeability. It was considered that crack initiation and disappearance was closely related with temperature difference between the surface and inner part. Knocking-out the mold is a difficult problem due to the small cell size, because continuous mesh structure of the metal foam is not strong. It is not easy to remove molding material after pouring. We can expect that water quenching can facilitate the knocking-out the mold after solidification without damaging cell structures. Collapsed particles after water quenching became bigger with the increase in time.

  • PDF

Performance Analysis with Various Amounts of Electrolyte in a Molten Carbonate Fuel Cell

  • Kim, Yu-Jeong;Kim, Tae-Kyun;Lee, Ki-Jeong;Lee, Choong-Gon
    • Journal of Electrochemical Science and Technology
    • /
    • 제7권3호
    • /
    • pp.234-240
    • /
    • 2016
  • The effect of initial electrolyte loading (IEL) on cell performance in a coin-type molten carbonate fuel cell (MCFC) was investigated in this work. Since the material of MCFC depends on the manufacturer, optimisation requires experimental investigation. In total, four IEL values, 1.5, 2.0, 3.0, and 4.0 g, were used, corresponding to a pore filling ratio (PFR) of 38, 51, 77, and 102%, respectively. The cell performance with respect to the PFR was analysed via steady-state polarisation, step-chronopotentiomtery, and impedance methods. The electrochemical analyses revealed that internal resistance and overpotential of the cell decreased with increasing PFR, and a large overpotential was observed when the PFR was 102%, probably due to the flooding phenomenon. After operation, cross-section of the cell was analysed via surface analysis of SEM and EDS methods, and the remaining electrolyte was estimated by dissolution of the cell in 10 wt% acetic acid. A linear relationship between IEL and the weight reduction ratio by dissolution was obtained. Thus, the remaining amount of electrolyte could be measured after operation. The results of SEM and EDS showed that a PFR of 38 and 102% showed a lack and flooding of electrolytes at the cell, respectively, which led to a large overpotential. This work reports that MCFC performance is allowed only in the narrow range of PFR.