• Title/Summary/Keyword: Filed test

Search Result 170, Processing Time 0.028 seconds

A Using Study for Fault Locator Algorithm of Distribution System (배전계통 고장점 표정 알고리즘 적용 연구)

  • Lee, Sung-Woo;Ha, Bok-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.74_76
    • /
    • 2009
  • This paper presents a discrete wavelet analysis based algorithm to address the fault impedance calculation under transient state in radial power distribution networks. The fault impedances have been derived under different fault conditions. Furthermore, a recursive fault distance estimation method is proposed utilizing the measured fault impedance and power line parameters. The proposed scheme can resolve the errors caused by the non-homogeneous power lines, the presence of lateral loads since, the fault impedance will always be updated with the recursive form. For the verification of the proposed scheme, a filed test has been peformed with varying fault resistances in the 22.9(kV) radial system. Power meters and fault locators were installed at the substation. It was figured out that the performance of the discrete wavelet and the recursive scheme are very good even for high fault resistance condition.

  • PDF

Setup and Operating Characteristics of the Experimental Apparatus for Magnetization Measurements of Sperconductor (초전도체 자화특성 측정을 위한 실험장치의 구축 및 그 동작 특성)

  • 최세용;나완수;주진호
    • Progress in Superconductivity and Cryogenics
    • /
    • v.1 no.2
    • /
    • pp.30-36
    • /
    • 1999
  • Superconductors are dissipative when exposed to time-varying magnetic fields. To analyze the AC characteristics of a superconductor, one usually needs to know magnetization curves of it. Good magnetization curves can be obtained only in homogeneous magnetic filed. In This paper, we report the setup and test results of a magnetization measurement system, which consists mainly of frequency-variable power supply and homeogenous magnet with 7-cm long air gap. Special emphasis are foused on the design and fabrication of the magnet, which aims to give background magnetic fields, and on the overall characteristics of the system.

  • PDF

TEST OF A LOW COST VEHICLE-BORNE 360 DEGREE PANORAMA IMAGE SYSTEM

  • Kim, Moon-Gie;Sung, Jung-Gon
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.137-140
    • /
    • 2008
  • Recently many areas require wide field of view images. Such as surveillance, virtual reality, navigation and 3D scene reconstruction. Conventional camera systems have a limited filed of view and provide partial information about the scene. however, omni directional vision system can overcome these disadvantages. Acquiring 360 degree panorama images requires expensive omni camera lens. In this study, 360 degree panorama image was tested using a low cost optical reflector which captures 360 degree panoramic views with single shot. This 360 degree panorama image system can be used with detailed positional information from GPS/INS. Through this study result, we show 360 degree panorama image is very effective tool for mobile monitoring system.

  • PDF

Size selectivity of the net pot for common octopus Octopus minor used in the southern coastal sea of Korea

  • Kim, Seonghun;Park, Seongwook;Lee, Kyounghoon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.49 no.3
    • /
    • pp.200-207
    • /
    • 2013
  • This paper presents the mesh selectivity of a net pot for common octopus Octopus minor for the sustainable resources management of common octopus. The filed experiments were carried out the total 10 times in the southern part of coastal sea in Korea from March to May in 2010 using net pots of five different mesh sizes (16, 18, 20, 22 and 26mm). The test of size selectivity, indicated a 50% selection value on the logistic master curve of 3.195, whereby 50% of individuals with a mantle size of approximately 70.3mm selected a mesh size of 22mm. Considering that 50% of common octopus entering sexual maturity have a mantle size of 70.6mm, the optimum mesh size should be equal to, or larger than 22mm.

An Experimental Study in Strength Control by Prediction Strength of Concrete using Equivalent Age in Construction Field (등가재령을 이용한 콘크리트의 강도 예측에 의한 건설생산현장에서의 강도관리에 관한 실험저 연구)

  • 주지현;최성우;박선규;김배수;남재현;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.287-290
    • /
    • 2000
  • Nowadays, strength control is performed by test of compressive strength of concrete which is taken in construction filed. But because it is possible to confirm only compressive strength of concrete by that way, it is difficult to performing strength control pr process plan, So, if we can predict compressive strength of concrete, we can decide when shores and forms can be removed safety, plan process efficiently. This study intends to propose basic data for strength control as determination the time of forwoak removal through investigating propriety of strength prediction using Freiesleben function.

  • PDF

Recursive Real Time Fault Locator with Wavelet Method (웨이브릿 기법을 이용한 리커시브 실시간 고장점 표정 시스템 연구)

  • Lee, Sung-Woo;Ha, Bok-Nam
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.9
    • /
    • pp.1522-1530
    • /
    • 2008
  • This paper presents a discrete wavelet analysis based algorithm to address the fault impedance calculation under transient state in radial power distribution networks. The fault impedances have been derived under different fault conditions. Furthermore, a recursive fault distance estimation method is proposed utilizing the measured fault impedance and power line parameters. The proposed scheme can resolve the errors caused by the non-homogeneous power lines, the presence of lateral loads since, the fault impedance will always be updated with the recursive form. For the verification of the proposed scheme, a filed test has been peformed with varying fault resistances in the 22.9(kV) radial system. Power meters and fault locators were installed at the substation. It was figured out that the performance of the discrete wavelet and the recursive scheme are very good even for high fault resistance condition.

Diagnosis on performance of turbine flowmeter using differential pressure in the meter (차압을 이용한 터빈유량계 성능 진단)

  • Ha, Young-cheol;Her, Jae-young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.153-159
    • /
    • 2004
  • We have investigated the feasibility of using differential pressure(pressure drop) of gas turbine meter to diagnose turbine performance degradation caused by mechanical wearing damage and/or dirt buildup or erosion. If the differential pressure between the upstream piping and the throat of a turine meter can be correlated to meter flow rate over the operating range of the meter, then a relatively simple differential pressure measurement in the filed might be used to detect meter performance changes. To test this method, we have conducted two experimental simulation on Straightener Integrated Type(SIT) turbine meter. One is fur dirt buildup on turbine blade, the other is for eccentricity of the blade. Results show that this method provide a reliable measure of performance degradation and is useful maintenance indicator.

  • PDF

An Evaluation on Energy Recovery Performance of the Ventilation System in Multi-Residential Building by Field Measurement (실험을 통한 공동주택 환기시스템의 실제 운전 시 전열교환성능 검토)

  • Choi, Younhee;Song, Doosam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.68-73
    • /
    • 2017
  • Recently, energy recovery ventilators (ERVs) have been installed for energy saving in many multi-residential buildings in Korea. The performance of the heat exchanger of an ERV is analyzed in this study under specific indoor and outdoor conditions in a test-cell measurement. However, the performance of the heat exchanger varies according to the indoor and outdoor condition. In this study, the performance of energy recovery of the ventilation system was therefore analyzed in actual weather conditions using field measurement. Experiments were conducted under winter conditions in a multi-residential building for 20 days. Based on the measurement results, the characteristics of sensible heat and latent heat exchange rates were analyzed.

An Estimation on Application of Slope Stabilization Method Using PC Strand Cable (케이블을 이용한 사면안정 공법 적용성 평가)

  • Kim, Hong-Taek;Baek, Seung-Cheol;Yoo, Chan-Ho;Jang, Chung-Gil;Min, Kyung-Nam
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.984-991
    • /
    • 2008
  • In this study, to evaluate the slope and tunnel stabilization method using pc cable with bulbed. To estimate the application of tunnel support using field tests and numerical analysis results. The reinforcement effects of slope stabilization method reinforced by PC cables were estimated compared with conventional soil nail system that reinforce the slope using rebar.

  • PDF

Construction of Field Test Evaluation System for 22.9 kV Switchgear (배전급 개폐기류 실증시험장 구축에 관한 연구(II))

  • Kim, I.S.;Jeong, J.Y.;Kim, M.K.;Shin, Y.J.;Kim, D.M.;Kim, J.Y.;Ha, D.H.;Jung, N.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.406-408
    • /
    • 2003
  • 본 고에서는 우리나라에 유일한 배전급 실증시험장인 전북 고창 시험장에 배전급 차단기 및 개폐기의 성능을 실증 평가 할 수 있는 기본 시험 시스템 구축에 관한 시험설비에 관하여 소개한다. 본 설비를 구축 활용하므로써 filed에서 발생되는 실증시험을 통해 국내 기자재의 성능 파악 및 신뢰도 향상을 제고하고자 한다.

  • PDF