• Title/Summary/Keyword: File Placement

Search Result 25, Processing Time 0.028 seconds

Comparison of accuracy between free-hand and surgical guide implant placement among experienced and non-experienced dental implant practitioners: an in vitro study

  • Dler Raouf Hama;Bayad Jaza Mahmood
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.5
    • /
    • pp.388-401
    • /
    • 2023
  • Purpose: This study investigated the accuracy of free-hand implant surgery performed by an experienced operator compared to static guided implant surgery performed by an inexperienced operator on an anterior maxillary dental model arch. Methods: A maxillary dental model with missing teeth (No. 11, 22, and 23) was used for this in vitro study. An intraoral scan was performed on the model, with the resulting digital impression exported as a stereolithography file. Next, a cone-beam computed tomography (CBCT) scan was performed, with the resulting image exported as a Digital Imaging and Communications in Medicine file. Both files were imported into the RealGUIDE 5.0 dental implant planning software. Active Bio implants were selected to place into the model. A single stereolithographic 3-dimensional surgical guide was printed for all cases. Ten clinicians, divided into 2 groups, placed a total of 60 implants in 20 acrylic resin maxillary models. Due to the small sample size, the Mann-Whitney test was used to analyze mean values in the 2 groups. Statistical analyses were performed using SAS version 9.4. Results: The accuracy of implant placement using a surgical guide was significantly higher than that of free-hand implantation. The mean difference between the planned and actual implant positions at the apex was 0.68 mm for the experienced group using the free-hand technique and 0.14 mm for the non-experienced group using the surgical guide technique (P=0.019). At the top of the implant, the mean difference was 1.04 mm for the experienced group using the free-hand technique and 0.52 mm for the non-experienced group using the surgical guide technique (P=0.044). Conclusions: The data from this study will provide valuable insights for future studies, since in vitro studies should be conducted extensively in advance of retrospective or prospective studies to avoid burdening patients unnecessarily.

An Efficient Decoy File Placement Method for Detecting Ransomware (랜섬웨어 탐지를 위한 효율적인 미끼 파일 배치 방법)

  • Lee, Jinwoo;Kim, Yongmin;Lee, Jeonghwan;Hong, Jiman
    • Smart Media Journal
    • /
    • v.8 no.1
    • /
    • pp.27-34
    • /
    • 2019
  • Ransomware is a malicious program code evolved into various forms of attack. Unlike traditional Ransomware that is being spread out using email attachments or infected websites, a new type of Ransomware, such as WannaCryptor, may corrupt files just for being connected to the Internet. Due to global Ransomware damage, there are many studies conducted to detect and defense Ransomware. However, existing research on Ransomware detection only uses Ransomware signature database or monitors specific behavior of process. Additionally, existing Ransomware detection methods hardly detect and defense a new Ransomware that behaves differently from the traditional ones. In this paper, we propose a method to detect Ransomware by arranging decoy files and analyzing the method how Ransomware accesses and operates files in the file system. Also, we conduct experiments using proposed method and provide the results of detection and defense of Ransomware in this paper.

Analyses of Replica Placement Schemes in Distributed File Systems (대용량 분산 파일 시스템의 복제 배치 기법 분석)

  • Choi, Dae-Soon;Kim, Jee-Hong;Eom, Young-Ik
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2012.06a
    • /
    • pp.373-375
    • /
    • 2012
  • 정보의 양이 늘어나고 그 크기가 커짐에 따라 많은 분야에서 대규모 분산 파일 시스템을 제안하고 사용하고 있다. 현재 제안된 분산 파일 시스템은 대부분 확장가능하며 장애에 견딜 수 있고 신뢰성이 있는 시스템을 기본으로 하여 구성되었다. 따라서 분산 파일 시스템은 장애에 효과적으로 견질 수 있고 높은 신뢰성을 보장하기 위해서 데이터의 복제를 만들어 서로 다른 스토리지에 배치한다. 본 논문에서는 대규모 분산 파일 시스템의 복제 배치 기법에 관하여 비교 분석 하였다. 먼저 분산 파일 시스템의 동작 구조를 확인하고 분산 파일 시스템에서 보편적으로 중요시 되는 특성을 파악하였다. 그리고 복제 배치 기법이 효과적인 분산 파일 시스템 구성 시 고려해야 할 것들을 부하 분산, 디스크 분산, 장애 분산으로 나누었다. 이 세 가지 요소를 기준으로 하여 분산 파일 시스템인 GFS, HDFS, Ceph, MooseFS의 복제 배치 기법을 분석하고 각각의 특성 파악하였다.

Harmonic Data Placement for Layered Encoded Multimedia File (계층적 압축방식 지원을 위한 멀티미디어 파일시스템)

  • 양승헌;박진연;원유집
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04a
    • /
    • pp.181-183
    • /
    • 2003
  • 본 논문에서는 적응적인 스트리밍 시스템 환경에서 계층적으로 압축된 멀티미디어 데이터의 저장구조와 자료인출 원리를 분석한다. 또한 네트워크 시뮬레이션을 이용, 네트워크 상에서 다양한 멀티미디어 스트리밍 부하의 특성을 분석한다. 두 가지 분석을 통해 기존의 멀티미디어 저장방식이 다양한 네트워크 환경과 시간에 따라 전송율이 변화하는 적응적 스트리밍 시스템의 요구를 충족시키지 못한다는 것을 확인한다. 이를 개선하기 위해 제안된 하모닉 인터리빙은 하모닉 인터리빙 방식은 전송비율이 높은 멀티미디어 데이터 블록의 위치를 연속적으로 배치하기 위해서 전송비율이 높은 계층과 그렇지 않은 계층을 별도의 그룹으로 나누어서 저장하는 방식이다. 실험을 통해서 네트워크 상황이 전송하고자 하는 영화의 대역폭을 보장하지 못하는 환경에서는 기존의 저장방식보다 새로 제안된 저장방식이 디스크 사용율에 있어 우수한 성능을 나타냄을 보인다.

  • PDF

A Caching Scheme of Meta-Information for the Linux Cluster File System (리눅스 클러스터 파일 시스템을 위한 메타정보 캐쉬 기법)

  • 홍재연;김형식
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.10c
    • /
    • pp.316-318
    • /
    • 2002
  • 클러스터 파일 시스템은 고가용성(high availability) 및 결함내성(fault tolerance)을 만족하고 확장성이 뛰어나기 때문에 멀티미디어 서비스 등으로 활용범위를 넓혀왔다. 클러스터 시스템에서 일반적으로 제공되는 단일 시스템 이미지 (single system image) 기술은 저장된 위치에 관계없이 디렉토리나 파일에 접근할 수 있는 장점을 제공하지만 실제 저장된 위치에 따라 접근 시간의 편차가 발생된다. 본 논문에서는 파일이나 디렉토리에 관한 메타정보를 캐쉬에 저장함으로써 클러스터 파일 시스템에서의 접근 시간을 단축하기 위한 방법을 제안한다. 파일과 디렉토리의 접근 형태에 적합한 캐쉬 배치(placement) 기법과 재배치(replacement) 기법을 제시하고 캐쉬 일관성 유지를 위한 알고리즘을 보인다. 제안된 방법은 멀티미디어 서비스 등의 응용에서 효과적으로 접근시간을 단축할 수 있을 것으로 예상된다.

  • PDF

Evaluation Toolkit for K-FPGA Fabric Architectures (K-FPGA 패브릭 구조의 평가 툴킷)

  • Kim, Kyo-Sun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.4
    • /
    • pp.15-25
    • /
    • 2012
  • The research on the FPGA CAD tools in academia has been lacking practicality due to the underlying FPGA fabric architecture which is too simple and inefficient to be applied for commercial FPGAs. Recently, the database of placement positions and routing graphs on commercial FPGA architectures has been built, and provided for enabling the academic development of placement and routing tools. To extend the limit of academic CAD tools even further, we have developed the evaluation toolkit for the K-FPGA architecture which is under development. By providing interface for exchanging data with a commercial FPGA toolkit at every step of mapping, packing, placement and routing in the tool chain, the toolkit enables individual tools to be developed without waiting for the results of the preceding step, and with no dependency on the quality of the results, and compared in detail with commercial tools at any step. Also, the fabric primitive library is developed by extracting the prototype from a reporting file of a commercial FPGA, restructuring it, and modeling the behavior of basic gates. This library can be used as the benchmarking target, and a reference design for new FPGA architectures. Since the architecture is described in a standard HDL which is familiar with hardware designers, and read in the tools rather than hard coded, the tools are "data-driven", and tolerable with the architectural changes due to the design space exploration. The experiments confirm that the developed library is correct, and the functional correctness of applications implemented on the FPGA fabric can be validated by simulation. The placement and routing tools are under development. The completion of the toolkit will enable the development of practical FPGA architectures which, in return, will synergically animate the research on optimization CAD tools.

Direct digital radiography versus conventional radiography for estimation of canal length in curved canals

  • Mohtavipour, Seiedeh Tahereh;Dalili, Zahra;Azar, Nasim Gheshlaghi
    • Imaging Science in Dentistry
    • /
    • v.41 no.1
    • /
    • pp.7-10
    • /
    • 2011
  • Purpose : The purpose of this study was to compare the conventional and digital radiography in the estimation of working length in mandibular molars. Materials and Methods : Sixty molar teeth were selected and divided into three groups in the basis of canal curves (0-$15^{\circ}$, 15-$30^{\circ}$, > $30^{\circ}$). After the placement of a 15 K-file, radiographs were taken with a conventional film (Fspeed) and a digital sensor. Canal lengths were measured in these images by two observers. Statistical analysis was performed with repeated measures of ANOVA and paired sample t-test with 95% confidence. Results : There was a high inter-observer agreement on the measurements of working length in conventional and digital radiographs. There was no significant difference between the mean values of measurements in conventional and digital radiography. Moreover, there was no significant difference between conventional and digital radiography with the actual values in the basis of canal curves. Conclusion : The accuracy of conventional and digital radiography in the determination of the working length was in an acceptable range.

A channel Routing System using CMOS Standard Cell Library (CMOS 표준 Cell Library를 이용하는 수평 트랙 배선 시스템)

  • 정태성;경종민
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.1
    • /
    • pp.68-74
    • /
    • 1985
  • In this Paper, we present a non-doglegging channel routing system for If layout using standard cells. This system produces a final two-layer wiring pattern in the horizontal track between two rows, each of which is a linear placement of standard cells of identical heights, satisfying the given net list specification. The layout of CMOS cell library Including nine primitive cells used in this paper is represented in CIF (Caltech Intermediate Form) using λ(Lambda) of 2 microns in Mead-Conway layout representation scheme. The cell dimension and 1/0 characteristics such as name, position and layer type of the pins are stored in Component Library to be used in the channel routing progranl, CROUT. 4 subprogram, NET-PLOT, was used to report a schemdtic layout result, and another subprogram, NETCIF was used to with a full-fledged final layout representation in GIF, A test run for realizing a dynamicmaster-slave D flip-flop with set/reset using primitive cells was shown to take 4 CPU seconds on VAX 11/780.

  • PDF

Property-based Hierarchical Clustering of Peers using Mobile Agent for Unstructured P2P Systems (비구조화 P2P 시스템에서 이동에이전트를 이용한 Peer의 속성기반 계층적 클러스터링)

  • Salvo, MichaelAngelG.;Mateo, RomeoMarkA.;Lee, Jae-Wan
    • Journal of Internet Computing and Services
    • /
    • v.10 no.4
    • /
    • pp.189-198
    • /
    • 2009
  • Unstructured peer-to-peer systems are most commonly used in today's internet. But file placement is random in these systems and no correlation exists between peers and their contents. There is no guarantee that flooding queries will find the desired data. In this paper, we propose to cluster nodes in unstructured P2P systems using the agglomerative hierarchical clustering algorithm to improve the search method. We compared the delay time of clustering the nodes between our proposed algorithm and the k-means clustering algorithm. We also simulated the delay time of locating data in a network topology and recorded the overhead of the system using our proposed algorithm, k-means clustering, and without clustering. Simulation results show that the delay time of our proposed algorithm is shorter compared to other methods and resource overhead is also reduced.

  • PDF

Effects of canal enlargement and irrigation needle depth on the cleaning of the root canal system at 3 mm from the apex (근관확대 및 세척 주사바늘의 근관 내 위치가 치근단 3 mm 부위의 근관 세정에 미치는 영향)

  • Moon, Ho-Jin;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.1
    • /
    • pp.24-28
    • /
    • 2012
  • Objectives: The aim of this study was to test the hypothesis, that the effectiveness of irrigation in removing smear layer in the apical third of root canal system is dependent on the depth of placement of the irrigation needle into the root canal and the enlargement size of the canal. Materials and Methods: Eighty sound human lower incisors were divided into eight groups according to the enlargement size (#25, #30, #35 and #40) and the needle penetration depth (3 mm from working length, WL-3 mm and 9 mm from working length, WL-9 mm). Each canal was enlarged to working length with Profile.06 Rotary Ni-Ti files and irrigated with 5.25% NaOCl. Then, each canal received a final irrigation with 3 mL of 3% EDTA for 4 min, followed by 5 mL of 5.25% NaOCl at different level (WL-3 mm and WL-9 mm) from working length. Each specimen was prepared for the scanning electron microscope (SEM). Photographs of the 3mm area from the apical constriction of each canal with a magnification of ${\times}250$, ${\times}500$, ${\times}1,000$, ${\times}2,500$ were taken for the final evaluation. Results: Removal of smear layer in WL-3 mm group showed a significantly different effect when the canal was enlarged to larger than #30. There was a significant difference in removing apical smear layer between the needle penetration depth of WL-3 mm and WL-9 mm. Conclusions: Removal of smear layer from the apical portion of root canals was effectively accomplished with apical instrumentation to #35/40 06 taper file and 3 mm needle penetration from the working length.