• Title/Summary/Keyword: Field probe

Search Result 685, Processing Time 0.02 seconds

Near-field Noise-emission Modeling for Monitoring Multimedia Operations in Mobile Devices

  • Song, Eakhwan;Choi, Jieun;Lee, Young-Jun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.6
    • /
    • pp.440-444
    • /
    • 2016
  • In this paper, an equivalent circuit model for near-field noise emission is proposed to implement a multimedia operation-monitoring system for mobile devices. The proposed model includes a magnetic field probe that captures noise emissions from multimedia components, and a transfer function for near-field noise coupling from a transmission line source to a magnetic field probe. The proposed model was empirically verified with transfer function measurements of near-field noise emissions from 10 kHz to 500 MHz. With the proposed model, a magnetic field probe was optimally designed for noise measurement on a camera module and an audio codec in a mobile device. It was demonstrated that the probe successfully captured the near-field noise emissions, depending on the operating conditions of the multimedia components, with enhanced sensitivity from a conventional reference probe.

A Study of Testing Method for Diagnostic Ultrasonic Array Probe through Pattern Analysis of Acoustic-Fields with Probe Channel Division (채널별 음장분포 분석을 통한 진단용 초음파 어레이 프로브의 평가방법에 관한 연구)

  • Yoo, B.C.;Choi, H.H.;Noh, S.C.;Min, H.K.;Kwon, J.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.5
    • /
    • pp.229-236
    • /
    • 2006
  • The acoustic field analysis method is the superior calibration method for rectifying the ultrasonic probe sensitivity. This method also can be applied to evaluate the probe performance in clinical fields without numerical analysis and precise measurements. In this paper, we propose the method of acoustic field pattern analysis with probe channel division for the evaluation of diagnostic ultrasound probe characterization. In order to verify our purpose, we performed a set of experiments. We measured the acoustic-field pattern of the three inferiority probes by channel division to evaluate an acoustic field distribution and impulse response characteristics. By comparing the results of acoustic field measurement method with that of conventional method such as impulse response and live image test for linear array probes, it is demonstrated that the ultrasound field measurement method is more effective then conventional method in detection of defective elements.

Fabrication of Near-field Scanning Optical Microscope(NSOM) Probe by Chemical Etching (화학적 식각을 이용한 근접장 주사 현미경용 탐침의 제작)

  • Kim, Sung-Chul;Lee, Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.555-557
    • /
    • 1995
  • In near field optics, optical fiber probe is smaller than the wavelength of light. This small probe makes it possible to overcome the diffraction limit due to wave property of light. In conventional optical systems, the image resolution is governed by wavelength. But in NSOM, it is determined by probe tip size and probe shape. Therefore probe tip size and shape are very important points in near field optics. In this paper, we will suggest the new fabrication methods of optical fiber probe and show that the probe tip size is sub-micrometer using SEM.

  • PDF

Optical and Mechanical Characteristics of NF System and NF Gap Control (근접장 광학계의 광학적 및 기계적 특성 분석과 근접장 간격제어)

  • Oh, Hyeong-Ryeol;Lee, Jun-Hee;Gweon, Dae-Gab;Kim, Soo-Kyung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1528-1532
    • /
    • 2000
  • The conventional optics and near field optics are compared numerically in the view points of the spot size and propagation characteristics. The decaying characteristics of near field light require the optics to access the object within several tens of nanometers. Therefore the gap control is one of the main issues in the near field optics area. In this paper the gap control is done by using the shear force of the NF(Near Field) probe and the characteristics are examined. The probe is modeled as a 2'nd order mass-spring-damper system driven by a harmonic force. The primary cause of the decrease in vibration amplitude is due to the damping force - shear force - between the surface and the probe. Using the model, damping constant and resonance frequency of the probe is calculated as a function of probe-sample distance. Detecting the amplitude and phase shift of the NF probe attached to the high Q-factor piezoelectric tuning fork, we can control the position of the NF probe about 0 to 50nm above the sample. The feedback signal to regulate the probe-sample distance can be used independently for surface topography imaging. 3-D view of the shear force image of a testing sample with the period of $1{\mu}m$ will be shown.

  • PDF

Non-contact critical current measurement of superconducting coated conductor using Hall Probe (Hall Probe를 이용한 초전도선재의 비접촉 임계전류 측정 방법)

  • Kim, Ho-Sup;Oh, Sang-Soo;Lee, Nam-Jin;Ha, Dong-Woo;Baik, Seung-Kyu;Ko, Rock-Kil;Ha, Hong-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.12-12
    • /
    • 2010
  • The hall probe measurement system was used to measure the critical current distribution of superconducting coated conductor. The system consists of reel to reel moving apparatus, 7 array hall probe, a rotary encoder and permanent magnet. The magnetic field profile across the width of superconducting coated conductor using Bean's critical state model was calculated. The effect of various parameters of the formulas on the magnetic field distribution and the effect of shape and size of artificial defects, which were formed on the surface of SmBa2Cu3O7-d(SmBCO) coated conductor using laser marking system, on the hall probe magnetic field signal of the hall probe measurement system was investigated.

  • PDF

Narrow Resonant Double-Ridged Rectangular Waveguide Probe for Near-Field Scanning Microwave Microscopy

  • Kim, Byung-Mun;Son, Hyeok-Woo;Cho, Young-Ki
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.406-412
    • /
    • 2018
  • In this paper, we propose a narrow resonant waveguide probe that can improve the measurement sensitivity in near-field scanning microwave microscopy. The probe consists of a metal waveguide incorporating the following two sections: a straight section at the tip of the probe whose cross-section is a double-ridged rectangle, and whose height is much smaller than the waveguide width; and a standard waveguide section. The advantage of the narrow waveguide is the same as that of the quarter-wave transformer section i.e., it achieves impedance-matching between the sample under test (SUT) and the standard waveguide. The design procedure used for the probe is presented in detail and the performance of the designed resonant probe is evaluated theoretically by using an equivalent circuit. The calculated results are compared with those obtained using the finite element method (Ansoft HFSS), and consistency between the results is demonstrated. Furthermore, the performance of the fabricated resonant probe is evaluated experimentally. At X-band frequencies, we have measured the one-dimensional scanning reflection coefficient of the SUT using the probe. The sensitivity of the proposed resonant probe is improved by more than two times as compared to a conventional waveguide cavity type probe.

Design and embodiment of variableness band style magnetic field nerve stimulation system that apply $1^{trigger}$ $2^{mode}$ magnetic field treatment Probe for disease treatment

  • Kim, Whi-Young;Park, Sung-Joon
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.4
    • /
    • pp.411-416
    • /
    • 2008
  • When compose magnetic field curer by belt and band style and need by magnetic field ripple last month, produce self-discipline roof. Bred in muscle disease (lumbago, backbone disease, corpulence) back. Result that study, manufactured various variableness band style - magnetic field probe firstly. Can establish self-discipline treatment pulse price by disease secondly. Could seek correct variableness band punishment, - magnetic field probe relationship implementation and property in waist, and so on, shoulder, neck, arm, leg, ankle, wrist etc. by third. Could find variableness band style energy value that need in-magnetic field Probe's treatment by fourth. This research could design pulse of self-discipline in band form and apply each according to disease.

Probe Design and Fabrication for Measuring Near Field (근역장 측정용 프로브의 설계 및 제작)

  • 김병찬;최형도;이애경;이형수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.2
    • /
    • pp.164-169
    • /
    • 2002
  • This paper reports on design and fabrication of near field probe operating at 300~3000 MHz. Design parameters are extracted by equivalent circuit of E-field probe and simulation using S parameter is performed to predict probes performance. The probe consists of a dipole antenna with 3.25 mm length, a zero bias Schottky diode and a highly resistive transmission line. A TEM cell was used for performance evaluation.

Optimal design of slider for stable flying characteristic using 4${\times}$l near-field probe array

  • Jung Min-su;Hong Eo-Jin;Park Kyoung-Su;Park No-Cheol;Yang Hyun-Seok;Park Young-Pil;Lee Sung-Q;Park Kang-Ho
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.171-176
    • /
    • 2005
  • In the information storage development, the trend of the storage device is to increase the recording density. Among such an effort, near-field probe recording is spotlighted as a method of high increasing recording density. For the successfully embodiment of storage device, the actuating mechanism of near-field probe is essentially designed. In this paper, we suggest the slider similar with conventional HDDs and design the slider using near- field probe for the purpose of applying the slider in order to control gap between probe and media. The most important object of slider design is to guarantee the flying ability and stability. For achievement of these design objects, we perform two step of optimal design process. The media is mod! eled as random displacement, which is only considered roughness of disk surface. The design slider is analyzed with dynamic state in assumed media. At this process, the optimal model is confirmed to stable flying stability.

  • PDF

Optimal Design of Slider for Stable Flying Characteristics using $4{\times}1$ Near-field Probe Array

  • Jung, Min-Su;Hong, Eo-Jin;Park, Kyoung-Su;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil;Lee, Sung-Q;Park, Kang-Ho
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.1
    • /
    • pp.65-70
    • /
    • 2006
  • In the information storage development, the trend of the storage device is to increase the recording density. Among such an effort, near-field probe recording is spotlighted as a method of high increasing recording density. For the successfully embodiment of storage device, the actuating mechanism of near-field probe is essentially designed. In this paper, we suggest the slider similar with conventional HDD and design the slider using near-field probe for the purpose of applying the slider in order to control gap between probe and media. The most important object of slider design is to guarantee the flying ability and stability. For achievement of these design objects, we perform two step of optimal design process. The media is supposed to model as random displacement, which is only considered roughness of disk surface. The design slider is analyzed with dynamic state in assumed media. At this process, the optimal model is confirmed to stable flying stability.

  • PDF