• Title/Summary/Keyword: Field performance test

Search Result 2,054, Processing Time 0.033 seconds

콘크리트궤도용 고속분기기 성능평가 (2) (Performance Evaluation of Swing-Nose Crossing Turnout on Slab Track (2))

  • 김시철;김만철;황광하;이동호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.717-724
    • /
    • 2011
  • In order to commercialize the track systems including the turnouts developed in Korea, the guideline of technical and systematic performance evaluation considering local environment was established on Aug. 2010. It consists of a technical compatibility, laboratory test and in-service test. Technical compatibility and laboratory test of the domestically-developed swing-nose crossing turnout on slab track(F18.5) were evaluated according to the guideline. And then in-service test was performed for the turnout installed at the 2nd phase site of Kyung-Bu HSR. In-service test is comprised of monitoring, and field and on-board test during KTX operation, where monitoring is to check the maintainability, and field and on-board test is to confirm structural and running safety. This paper is intended to explain the requirements for the in-serve test and analyze the results of monitoring and the data measured at field and on-board. Based on the in-service test, it is proven that performance of the domestically-developed swing-nose crossing turnout on slab track(F18.5) well satisfies the requirements of the guideline.

  • PDF

Monitoring and Analysis of 3kW Grid-Connected PV System for Performance Evaluation

  • So Jung-Hun;Jung Young-Seok;Yu Gwon-Jong;Choi Ju-Yeop;Choi Jae-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권1호
    • /
    • pp.57-62
    • /
    • 2005
  • Grid-connected photovoltaic (PV) systems were installed and monitored at the field demonstration test center (FDTC) in Korea in October 2002. Before long-term field testing of installed PV systems, the performances of PV components were evaluated and compared through short-term performance tests of each of the PV system components such as power conditioning system and PV module under standard test conditions. A data acquisition system has been constructed for measuring and analyzing the performance of PV systems to observe the overall effect of environmental conditions on their operation characteristics. Performances of PV systems have been evaluated and analyzed not only for component perspective (PV array, power conditioning unit) but also for global perspective (system efficiency, capacity factor, electrical power energy) by review of the field test and loss factors of the systems. These results indicate that it is highly imperative to develop an optimum design technology of grid connected PV systems. The objective of this paper is not only to evaluate and analyze the performance of domestic PV systems application through long-term field testing at FDTC but also to develop evaluation, analysis and optimum technology for long-term stability and reliability of grid-connected PV systems in Korea.

Students' Field-dependency and Their Mathematical Performance based on Bloom's Cognitive Levels

  • Alamolhodaei, Hassan;Hedayat Panah, Ahmad;Radmehr, Farzad
    • 한국수학교육학회지시리즈D:수학교육연구
    • /
    • 제15권4호
    • /
    • pp.373-386
    • /
    • 2011
  • Students approach mathematical problem solving in fundamentally different ways, particularly problems requiring conceptual understanding and complicated strategies. The main objective of this study is to compare students' performance with different thinking styles (Field-dependent vs. Field independent) in mathematical problem solving. A sample of 242 high school males and females (17-18 years old) were tested based on the Witkin's cognitive style (Group Embedded Figure Test) and by a math exam designed in accordance with Bloom's Taxonomy of cognitive level. The results obtained indicated that the effect of field dependency on student's mathematical performance was significant. Moreover, field-independent (FI) students showed more effective performance than field-dependent (FD) ones in math tasks. Male students with FI styles achieved higher results compared to female students with FD cognitive style. Moreover, FI students experienced few difficulties than FD students in Bloom's Cognitive Levels. The implications of these results emphasize that cognitive predictor variables (FI vs. FD) could be challenging and rather distinctive factor for students' achievement.

유로 형상 변화에 따른 CFD 해석 결과와 PEM 연료전지 성능 비교 (Comparison between CFD analysis and experiments according to various PEMFC flow-field designs)

  • 이강인;박민수;이세원;주종남
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.572-575
    • /
    • 2008
  • Flow-field design has much influence over the performance of proton exchange membrane fuel cell (PEMFC) because it affects the pressure magnitude and distribution of the reactant gases. To obtain the pressure magnitude and distribution of reactant gases in four kinds of flow-field designs without additional measurement equipment, computational fluid dynamics (CFD) analysis was performed. After the CFD analysis, the performance values of PEMFC according to the flow-field configurations were measured via a single cell test. As expected, the pressure differences due to different flow-field configurations were related to the PEMFC performance because the actual performance results showed the same tendency as the results of the CFD analysis. A large pressure drop resulted in high PEMFC performance. So, the single serpentine configuration gave the highest performance. On the other hand, the parallel flow-field configuration gave the lowest performance because the pressure difference between inlet and outlet was the lowest.

  • PDF

Modular and versatile platform for the benchmarking of modern actuators for robots

  • Garcia, Elena;Gonzalez-de-Santos, Pablo
    • Smart Structures and Systems
    • /
    • 제11권2호
    • /
    • pp.135-161
    • /
    • 2013
  • This work presents a test platform for the assessment and benchmarking of modern actuators which have been specifically developed for the new field and service robotics applications. This versatile platform has been designed for the comparative analysis of actuators of dissimilar technology and operating conditions. It combines a modular design to adapt to linear and rotational actuators of different sizes, shapes and functions, as well as those with different load capacities, power and displacement. This test platform emulates the kinematics of robotic joints while an adaptive antagonist-load actuator allows reproducing the variable dynamic loads that actuators used in real robotics applications will be subjected to. A data acquisition system is used for monitoring and analyzing test actuator performance. The test platform combines hardware and software in the loop to allow actuator performance characterization. The use of the proposed test platform is demonstrated through the characterization and benchmarking of three controllable impedance actuators recently being incorporated into modern robotics.

폴리머 LP애자의 설계해석과 전기적 성능 시험 (The Design Analysis and Electrical Performance Test of Polymer LP Insulator)

  • 이운용;조한구;박상호;송홍준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.399-401
    • /
    • 2000
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission and distribution line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage(UHV) transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. In this paper, polymer line post insulator has been designed and investigated electric field distribution by FEM. Designed LP insulators have been tested as insulator performance test, such as power frequency voltage test, lightning impulse voltage test, artificial pollution test and flexural load test.

  • PDF

중온아스팔트 혼합물의 현장 적용성 및 실내 공용성 평가 (A Study on Field Application and Laboratory Performance Evaluation of Warm Mix Asphalt)

  • 양성린;백철민;정규동;김영민;김용주;황성도
    • 한국도로학회논문집
    • /
    • 제14권4호
    • /
    • pp.9-18
    • /
    • 2012
  • PURPOSES : This study evaluated the field applicability and laboratory performance of warm-mix asphalt (WMA) as an alternative technology in asphalt pavement. METHODS : The pilot road using two different types of WMA mixture and one HMA mixture was constructed in Waegwan-Seokjeok road construction site and the mixtures were sampled at the asphalt plant for laboratory testings. The field applicability was assessed in environmental aspects, such as $CO_2$ emission, and in aspects of constructibility using the existing equipment and procedure, i.e., thickness and density measurement. The laboratory testings included the moisture susceptibility test by AASHTO T283, dynamic modulus test, triaxial repeated load permanent deformation test, and the fatigue test. RESULTS : The temperatures for production and compaction of WMA were $20{\sim}30^{\circ}C$ lower than those for HMA and therefore, the noxious gas emission were significantly reduced. The field density of WMA pavements was similar or better than that of HMA pavement. From the laboratory testings, it was found that WMA mixtures exhibit comparable performance to HMA mixture in moisture susceptibility, permanent deformation, and fatigue performance. CONCLUSIONS : With these results, it would be concluded that WMA could replace the existing HMA technology without any significant issue. To support this conclusion, it is necessary to track the long-term performance of WMA in pilot road.

PMC 차량용 자동복합연결기 성능평가 (Automatic Multi-coupler Performance Evaluation for the PMC Rolling Stock)

  • 이찬우;허현무
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.368-375
    • /
    • 1999
  • This paper describes the evaluation methods and criteria used verify field performance of automatic multi-coupler for the PMC rolling stock. Automatic multi-coupler was designed and manufactured by KRRI , Woojin electric machinery CO., and Yujinchajeon MFG.CO., LTD in 1999. Through field performance test of PMC rolling stock, vibration, brake system, assembly and disassembly of complex train were measured on the condition of service operation. As a result, test results meet the criteria proposed by KNR and KRRI.

  • PDF

도로포장 보수용 상온식 균열실링 재료의 개발 및 평가 (Development and Evaluation of Cold-applied Crack Sealant for Pavement Maintenance)

  • 김영민;정규동;이강훈;임정혁
    • 한국도로학회논문집
    • /
    • 제19권2호
    • /
    • pp.45-53
    • /
    • 2017
  • PURPOSES: The objectives of this study are to develop a new cold-applied crack sealant and to evaluate its properties and field applicability by comparing with other conventionally used crack sealants. METHODS : A new cold-applied crack sealant was developed by using neoprene latex to improve material properties. The fundamental properties such as viscosity, residue %, penetration, and softening point of the developed crack sealant were tested by TxDOT criteria to evaluate crack sealing capability. Moreover, the performance of the developed cold-applied crack sealant was evaluated under both laboratory and field conditions. In the laboratory, the bond property was evaluated using the developed cold-applied crack sealant and conventional hot-applied crack sealant by the bond-properties test standardized under ASTM D 6690. In the field, test sections were constructed on three areas: a trunk road, bus-only lane, and motorway, with the developed crack sealant and three conventional crack sealants. After construction, early field-inspection was performed on the test sections. RESULTS AND CONCLUSIONS : Overall, the developed cold-applied crack sealant demonstrates reasonable storage stability, durability, and bond property compared to conventional hot-applied crack sealants. From the test sections, it was established that the developed cold-applied crack sealant does not pose construction issues. Moreover, the early performance was verified through field inspection. However, as the field inspection was conducted a week after the construction, it is necessary to conduct an inspection of performance from a long-term point of view.

Impact of composite materials on performance of reinforced concrete panels

  • Mazek, Sherif A.;Mostafa, Ashraf A.
    • Computers and Concrete
    • /
    • 제14권6호
    • /
    • pp.767-783
    • /
    • 2014
  • The use of composite materials to strengthen reinforced concrete (RC) structures against blast terror has great interests from engineering experts in structural retrofitting. The composite materials used in this study are rigid polyurethane foam (RPF) and aluminum foam (ALF). The aim of this study is to use the RPF and the ALF to strengthen the RC panels under blast load. The RC panel is considered to study the RPF and the ALF as structural retrofitting. Field blast test is conducted. The finite element analysis (FEA) is also used to model the RC panel under shock wave. The RC panel performance is studied based on detonating different TNT explosive charges. There is a good agreement between the results obtained by both the field blast test and the proposed numerical model. The composite materials improve the RC panel performance under the blast wave propagation.