• 제목/요약/키워드: Field in Field

검색결과 70,201건 처리시간 0.082초

6 MV Linac을 이용한 Symmetric field와 Asymmetric field에서 Wedge factor의 비교 고찰 (Intercomparison of Wedge factor for Symmetric field and Asymmetric field used 6MV Linac)

  • 지연상;한재진
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제22권2호
    • /
    • pp.57-60
    • /
    • 1999
  • Therapy equipment have taken progress for Cancer make use of Radiation for the normal tissue system make much of important for shielding. In modern times independent jaw setting to used equipment as possible make use of asymmetric field. Therefore, the asymmetric field be leave out of consideration wedge factor because of with used wedge for the most of part. These experimentation find out have an effect on the dosimetry of out put compared with of the difference between the symmetric field and asymmetic field for the wedge factor.

  • PDF

Development of Micro-size Search Coil Magnetometer for Magnetic Field Distribution Measurement

  • Ka, E.M.;Son, De-Rac
    • Journal of Magnetics
    • /
    • 제13권1호
    • /
    • pp.34-36
    • /
    • 2008
  • For the measurement of the magnetic field distribution with high spatial resolution and high accuracy, the magnetic field sensing probe must be non-magnetic, but the MFM probe and sub-millimeter-meter size Hall probe use a ferromagnetic tip and block, respectively, to increase the sensitivity. To overcome this drawback, we developed a micro-size search coil magnetometer which consists of a single turn search coil, Terfenol-D actuator, scanning system, and control software. To reduce the noise generated by the stray ac magnetic field of the actuator driving coil, we employed an even function $\lambda$-H magnetostriction curve and lock-in technique. Using the developed magnetometer, we were able to measure the magnetic field distribution with a magnetic field resolution of 1 mT and spatial resolution of $0.1mm{\times}0.2mm$ at a coil vibration frequency of 1.8 kHz.

고주파 회전자계를 이용한 역전자계 배위 안정성연구 (A Study on the Formation of Reversed Field configuration stability with Radio Rotating Field)

  • 김원섭;황종선;김종만;김영민
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 영호남 합동 학술대회 및 춘계학술대회 논문집 센서 박막 기술교육
    • /
    • pp.121-124
    • /
    • 2006
  • It is widely know that one of the most important tasks is the research of plasma for the purpose o nuclear fusion, is to make a stable confinement of high ${\beta}$ value plasma. And, for making the stable confinement, pinch pl-asma produced by reversed field has been mainly studied yet. Magnetic field has been used to hold plasma at high temperature for a long time. Reverse field has shown unstable process. Using ratio frequency, the author could control the instability of the process and formed a stable erversed field. Inthe experiment let a reversed field configuration from by adding-Bias field in advance.

  • PDF

Azimuthal anchoring measurement of nematic liquid crystals using the strong magnetic field

  • Jang, Tae-Sug;Im, Ji-Young;Goh, Wan-Hee;Kim, Jong-Hyun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.664-667
    • /
    • 2009
  • We would like to show a measuring technique of azimuthal anchoring energy of the nematic liquid crystals. The electro-optical setup of liquid crystal cell, crossed polarizers and magnetic field was assumed. The planar or hybrid alignment cells were prepared. The director in the light entering substrate and the polarization of light was adjusted into parallel to the magnetic field. The director orientation of exit substrate and analyser maintained perpendicular to the magnetic field. As the magnetic field strength is increased, the director deviates from the easy axis and rotates to the field direction. We obtained an equation calculating the change of transmission with the field and measured experimentally the transmission. By comparing the calculating and experimental data, we obtained the azimuthal anchoring strength.

  • PDF

Flat Field Anastigmat 조건을 만족하는 3반사 망원경 광학계 설계 (Optical design of flat field anastigmatic three-mirror telescope)

  • 최세철;김현규;김연수
    • 한국광학회지
    • /
    • 제8권3호
    • /
    • pp.175-182
    • /
    • 1997
  • 가시광선 영역의 고분해능 3반사 망원경 광학계 설계를 위하여, 광학계의 기구적 제한사항을 만족함과 동시에 Flat Field Anastigmat 조건을 만족하는 해를 구하는 초기설계 기법이 제시되었으며, 이를 기초로 프로그램을 작성하여 F/14.5, 구경 600 mm, 시야 0.27.deg. * 1.3.deg.의 3반사 망원경광학계의 초기설계를 수행하였다. 초기 설계된 광학계의 최적화를 위하여 Code V를 사용하였으며, 그 결과로서 CCD의 모서리 부분 Field를 제외한 모든 Field에서 Nyquist Frequency에서의 MTF값이 0.5이상이었다.

  • PDF

펄스 전기장에 의한 $Pb(Zr_xTi_{1-x})O_3$ 강유전체의 전자 방출 (Electron Emission from $Pb(Zr_xTi_{1-x})O_3$ Ferroelectrics by Pulsed Electric Field)

  • 김용태;윤기현;김태희;박경봉;곽상희
    • 한국세라믹학회지
    • /
    • 제37권1호
    • /
    • pp.6-11
    • /
    • 2000
  • Electron emission from the Pb(ZrxTi1-x)O3 ferroelectrics by pulsed electric field has been investigated as a function of Zr/Ti ratios such as 35/65, 50/50 and 65/35 below 250kV/cm. Electrons were emitted regardless of the applied field polarity to the rear electrode. When the negative field was applied to the rear electrode, the electron emission charge was more stable. It was proved that the electrons were emitted at the edge of the upper electrode. The emission charge increased in order of 65/35>50/50>35/65. The electron emission characteristics were dependent on the ferroelectric properties such as polarization and coercive field. The emission charge and emission threshold field were affected by the polarization change and the coercive field, respectively. This result explains that the electron emission is a field emission with polarization induced surface potential by a modified Fowler-Nordheim plot of emission charge.

  • PDF

고주파 회전자계를 이용한 역전자계 배위 안정성연구 (A Study on the Formation of Reversed Field configuration stability with Radio Rotating Field)

  • 김원섭;황종선;김종만;김영민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2187-2189
    • /
    • 2005
  • It is widely know that one of the most important tasks is the research of plasma for the purpose o nuclear fusion, is to make a stable confinement of high ${\beta}$ value plasma. And, for making the stable confinement, pinch p1-asma produced by reversed field has been mainly studied yet. Magnetic field has been used to hold plasma at high temperature for a long time. Reverse field has shown unstable process. Using ratio frequency, the author could control the instability of the process and formed a stable erversed field. Inthe experiment let a reversed field configuration from by adding-Bias field in advance.

  • PDF

ANALYSIS OF HIGH-FIELD MAGNETIZATION PROCESS IN $Sm_{2}Fe_{17}N_{3.0}$

  • Zhao, T.S.;Jin, H.M.;Lee, J.I.;Paug, K.S.
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.679-682
    • /
    • 1995
  • The observed high-field magnetization curves of $Sm_{2}Fe_{17}N_{3.0}$ at 4.2 K and 296 K are well reproduced by the calculation using the Sm-Fe exchange field $2\mu\textrm{B}H_{ex}\;=\;320\;K$ and two crystalline electric field parameters ${A_{0}}^{2}=\;-910\;K$ and ${A_{1}}^{0}=\;200\;K$. The calculation shows that during the magnetization process along the hard axis at 4.2 K, the Sm moment rotates toward the direction antiparallel to H when H < 110 kOe and then returns to the field direction with further increase of the field. At 296 K, the Sm moment rotates toward the direction antiparallel to H monotonously with increasing field and finally becomes antiparallel to H when $H{\geq}H_{A}=210\;kOe$. The particular magnetization process of the Sm moment can be explained by the field-induced noncollinear coupling between the spin and orbital moments of the Sm ion.

  • PDF

Solar Interior Currents Presumed by Solar Surface Magnetic Fields

  • Bogyeong Kim;Yu Yi
    • 천문학회지
    • /
    • 제56권2호
    • /
    • pp.187-194
    • /
    • 2023
  • The remote sensing technique of measuring the magnetic field was applied first to sunspots by Hale (1908). Later Babcock (1961) showed that the solar surface magnetic field on a global scale is a dipole in first-order approximation and that this dipole field reverses once every solar cycle. The Wilcox Solar Observatory (WSO) supplies the spherical harmonics coefficients of the solar corona magnetic field of each Carrington Rotation, calculated based on the remotely-sensed photospheric magnetic field of the solar surface. To infer the internal current system producing the global solar coronal magnetic field structure and evolution of the Sun, we calculate the multipole components of the solar magnetic field using the WSO data from 1976 to 2019. The prominent cycle components over the last 4 solar activity cycles are axis-symmetric fields of the dipole and octupole. This implies that the current inversion driving the solar magnetic field reversal originates from the equatorial region and spreads to the whole globe. Thus, a more accurate solar dynamo model must include an explanation of the origin and evolution of such solar internal current dynamics.

Effect of few-walled carbon nanotube crystallinity on electron field emission property

  • Jeong, Hae-Deuk;Lee, Jong-Hyeok;Lee, Byung-Gap;Jeong, Hee-Jin;Lee, Geon-Woong;Bang, Dae-Suk;Cho, Dong-Hwan;Park, Young-Bin;Jhee, Kwang-Hwan
    • Carbon letters
    • /
    • 제12권4호
    • /
    • pp.207-217
    • /
    • 2011
  • We discuss the influence of few-walled carbon nanotubes (FWCNTs) treated with nitric acid and/or sulfuric acid on field emission characteristics. FWCNTs/tetraethyl orthosilicate (TEOS) thin film field emitters were fabricated by a spray method using FWCNTs/TEOS sol one-component solution onto indium tin oxide (ITO) glass. After thermal curing, they were found tightly adhered to the ITO glass, and after an activation process by a taping method, numerous FWCNTs were aligned preferentially in the vertical direction. Pristine FWCNT/TEOS-based field emitters revealed higher current density, lower turn-on field, and a higher field enhancement factor than the oxidized FWCNTs-based field emitters. However, the unstable dispersion of pristine FWCNT in TEOS/N,N-dimethylformamide solution was not applicable to the field emitter fabrication using a spray method. Although the field emitter of nitric acid-treated FWCNT showed slightly lower field emission characteristics, this could be improved by the introduction of metal nanoparticles or resistive layer coating. Thus, we can conclude that our spray method using nitric acid-treated FWCNT could be useful for fabricating a field emitter and offers several advantages compared to previously reported techniques such as chemical vapor deposition and screen printing.