• Title/Summary/Keyword: Field heat

Search Result 2,032, Processing Time 0.026 seconds

Computation of Stress Field During Additive Manufacturing by Explicit Finite Element Method (외연적 유한요소법을 이용한 적층제조 공정 중 응력 장 변화 계산)

  • Yang, Seung-Yong;Kim, Jeoung Han
    • Journal of Powder Materials
    • /
    • v.27 no.4
    • /
    • pp.318-324
    • /
    • 2020
  • In the present work, an explicit finite element analysis technique is introduced to analyze the thermal stress fields present in the additive manufacturing process. To this purpose, a finite element matrix formulation is derived from the equations of motion and continuity. The developed code, NET3D, is then applied to various sample problems including thermal stress development. The application of heat to an inclusion from an external source establishes an initial temperature from which heat flows to the surrounding body in the sample problems. The development of thermal stress due to the mismatch between the thermal strains is analyzed. As mass scaling can be used to shorten the computation time of explicit analysis, a mass scaling of 108 is employed here, which yields almost identical results to the quasi-static results.

The Experimental Study of Heat Generation Efficiency of Magnetic Hyperthermia System (자기 온열 시스템의 열 발생 효율에 관한 실험적 연구)

  • Song, Young-Jin;Oh, Jung-Hwan
    • Journal of the Korean Society of Combustion
    • /
    • v.16 no.2
    • /
    • pp.33-39
    • /
    • 2011
  • We demonstrated heat generation efficiency of the magnetic hyperthermia system to find optimal condition using gelatin tissue phantom. Magnetic hyperthermia induction can be used to make heat generation with different concentration of $Fe_3O_4$ iron oxide inside tissue phantom and magnetically labeled cells by applying AC magntic field at a frequency of 145 kHz. It was observed that the maximum temperature achieved in the magnetic gelatin tissue phantom increased with the concentration of $Fe_3O_4$ iron oxide and alternating magnetic field intensity. Results were discussed with respect to further optimization of therapeutic technique for biomedical application with modified functional nanoparticles.

Numerical Analysis of Flow and Heat Transfer in Duct with Repeated Cylindrical Blockages by Non-orthogonal Coordinate Transformation (주기적인 원주형 장애물이 있는 덕트유동 및 열전달의 비직교좌표변환에 의한 해석)

  • Choi, Y.D.;Lee, G.H.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.4
    • /
    • pp.473-488
    • /
    • 1988
  • This paper is concerned with the prediction of two dimensional turbulent flows in the parallel plate with the repeated cylindrical blockages. The purpose of this paper is to find the effect of the eccentricity and the pitch of the repeated cylindrical blockages on the flow field, heat transfer coefficients and friction factors. A special technique is developed for the solution of the fully developed turbulent recirculating flow, in which the flow field varies periodically. A non-othogonal coordinate transformation is employed to solve the momentum and the energy equations. The results show that the pitch ratio or the eccentricity of the repeated blockages become smaller, or the Reynolds number of the flow larger, friction factors and heat transfer coefficients increase.

  • PDF

Evaluation of thermal conductivity in REBCO coated conductor

  • Yong-Ju, Hong;Sehwan, In;Hyobong, Kim;Hankil, Yeom
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.4
    • /
    • pp.78-83
    • /
    • 2022
  • REBCO coated conductors are widely used for HTS power application, high magnetic field magnet application, and etc. A thermal stability of the REBCO conductor is essential for the operation of HTS-based device, and thermal conductivities of the conductor are relevant parameters for modeling cryogenic heat transfer. REBCO conductors consist of a REBCO layer, copper layers for electrical stabilization and a hastelloy substrate. At cryogenic temperature, thermal conductivity of copper and silver strongly depend on the purity of the material and the intensity of the magnetic field. In this study, thermal conductivities of the laminated composite structure of REBCO conductor are evaluated by using the thermal network model and the multidimensional heat conduction analysis. As a result, the thermal network model is applicable to REBCO conductors configured in series or parallel alone and multidimensional heat conduction analysis is necessary for complex cases of series and parallel configuration.

CFD ANALYSIS OF HEAT TRANSFER PERFORMANCE OF A REFRIGERATOR CONDENSER (CFD 해석을 통한 냉장고용 응축기 전열성능 연구)

  • Yoo, S.S.;Hwang, D.Y.;Lee, M.S.;Han, B.Y.;Park, H.K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.303-309
    • /
    • 2009
  • In this study, the heat transfer and flow field of condenser used on Kim-chi refrigerator is analysed with numerical method. Main objective is to present the base data for designing new condenser model with improvement of heat transfer performance. For CFD analysis, a commercial code, STAR-CCM+ was used. The water was used for the inner working fluid and the air was used for the outer fluid. The condenser type used in this study is a flat plate fin-and-tube heat exchanger. As factors for performance analysis, the effect of condenser geometry and air velocity was investigated. As a result, it has been observed that there is a suitable fin pitch with which heat transfer performance of condenser is maximized.

  • PDF

A Study on the Spray Cooling Characteristics according to the Angle of Hot Heat Transfer Surface (고온 열전달면의 각도에 따른 분무냉각 특성에 관한 연구)

  • Yoon, D.H.;Oh, C.;Yoon, S.H.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.320-327
    • /
    • 2002
  • An experimental study of heat transfer from hot flat surface to water sprays was conducted in high temperature region. Heat transfer measurements for hot flat surface were made by 4 sheathed C-A thermocouples. Droplets volume flux were also measured-independently at a position in spray field. The test conditions included variations in droplets volume flux, subcooling of cooling water of $1.565\times10^{-3} to 14.089\times10^{-3}m^3/m^2s and 80 to $20^{\circ}C$ respectively. The effects of inclination angle on heat transfer were investigated and changes in inclination angle of hot flat surface affected heat transfer coefficients of high temperature region.

Study on Low Heat Cements (저발열형 시멘트 개발에 관한 연구)

  • Choi, Jae-Woong;Ha, Jae-Dam;Kim, Dong-Seuk;Kim, Ki-Soo;Choi, Long
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.46-51
    • /
    • 1999
  • Mass concrete structures have many critical points in service. The cracks caused by the heat of hydration is the most serious problem, so that many method ot control cracks(precooling, postcooling, etc) have been applied to construction. But cooling methods take high cost and many installation and limits of field. Therefore it is useful to use the low heat hydration cements for low cost. This paper describes the characteristics of a low heat cement mixing the ternary components of cement(portland cement, blast furnace slag, fly ash) recently developed for mass concrete, belite cement, low heat slag cement(belite base) and fly ash cement (belite base). The objective of this paper is to study on low heat cement about initial compressive strength and hydration heat.

  • PDF

Mock-up Test of Low Heat Concrete Using High Volume Mineral Admixture (혼화재를 다량 사용한 저발열 콘크리트의 모의부재실험)

  • Kim, Yong-Ro;Song, Young-Chan;Kim, Hyo-Rak;Park, Jong-Ho;Yoo, Jung-Hoon;Jeong, Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.31-34
    • /
    • 2011
  • In this study, for the evaluation of field application of low heat concrete using high volume mineral admixture, the characteristics of hydration heat generation and engineering properties of low heat concrete was investigated by mock-up test according to the replacement ratio of mineral admixture. Also, it was evaluated the compressive strength of low heat concrete with curing temperatures and ages for effective concrete mix design considering seasonal change.

  • PDF

Saturated Boiling Heat Transfer of Freon-113 in Hemispherical Narrow Space and Implications for Degraded Core Coolability in Reactor Vessel Lower Plenum

  • Bang, Kwang-Hyun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.574-579
    • /
    • 1995
  • Saturated boiling heat transfer experiment in a hemispherical narrow space is conducted using Freon-113 to investigate an additional heat removal capability through a hypothetical gap between lower head and degraded core. The narrow space of 1mm consists of a 124mm diameter heated stainless steel hemisphere and a glass outer vessel. Within the hemispherical narrow space large coalesced bubbles are produced and these bubbles rise in random direction, causing liquid flow in from the opposite side to fill the region. Such flow in random direction makes the flow field in the narrow space very chaotic and thus enhance heat transfer. The heat transfer coefficient is higher at lower angle and at higher heat flux. The present study shows that the liquid from upper region can effectively penetrate into the gap and augment the heat removal capability through tile gap.

  • PDF

Characteristics of the Air-side Particulate Fouling Materials in Finned-Tube Heat Exchangers of Air Conditioners (공기조화기용 열교환기의 공기측 파울링 입자 분석 연구)

  • 안영철;신희수;황유진;이창건;이재근;이현욱;안승표;윤덕현;하삼철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.7
    • /
    • pp.611-617
    • /
    • 2003
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. The purpose of this study is to investigate the characteristics of the air-side particulate fouling materials in finned-tube heat exchangers of air conditioners. Air conditioners being used in the field such as inns, restaurants, and offices are collected in chronological order in use. Typical fouling materials on the heat exchangers include fibers and dusts ranged from 6.6 to 20.9 ${\mu}{\textrm}{m}$ in mass median diameter.