• Title/Summary/Keyword: Field heat

Search Result 2,032, Processing Time 0.032 seconds

Multi-physics Topology Optimization of High Efficiency Motor Considering Electromagnetics and Heat Transfer (전자기와 열전달을 고려한 고효율 모터의 다분야 위상최적설계)

  • Wang, Se-Myung;Shim, Ho-Kyoung;Moon, Hee-Gon;Cho, Yang-Hee;Kim, Myung-Kyu
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1058-1063
    • /
    • 2004
  • This paper presents a new approach regarding thermal characteristics associated with a design of the high efficiency motor. Electrical conduction materials, such as coil and aluminum embedded in the core generate high heat exerting negative influence on both lifetime and performance of machine. Thus, it is necessary to design high efficiency motor considering heat transfer in order to improve motor performance and to be protected against overheating. In this paper, firstly, numerical analysis of electromagnetic field is carried out by the nonlinear transient finite element method (FEM). Secondly, the linear static FEA of magneto-thermal field is implemented by applying source current computed by the nonlinear transient analysis. FE results are validated in terms of electromagnetics and heat transfer by experiments. And then, the pseudo-transient topology optimization using a multi-objective function is performed. The proposed method is applied to a squirrel cage single-phase induction motor of the scroll compressor.

  • PDF

Experimental Study on the Natural Convective Heat Transfer Characteristics of Ferrofluid for Concentric Annuli under Rotating Magnetic Field (회전수 및 자기장강도 변화에 따른 이중원관내 자성유체의 자연대류 열전달 특성에 관한 실험적 연구)

  • Kim, Hyung-Jin;Seo, Jae-Hyeong;Kim, Dae-Wan;Lee, Moo-Yeon;Seo, Lee-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.2
    • /
    • pp.77-81
    • /
    • 2013
  • The objective of this study is experimentally to investigate natural convective heat transfer characteristics of the ferrofluid for a concentric annuli under rotating magnetic field with variations of the revolution and the magnetic field strength. The rotating magnetic field was provided by induction motor with 6 poles and 3 phases and the revolution and the magnetic field strength were controlled by an inverter driver and a voltage meter, respectively. Temperatures of the inner pipe and the outer pipe in the tested concentric annuli were maintained at $30^{\circ}C$ and $25^{\circ}C$, respectively, during the test and the direction of the rotating magnetic field was a counterclockwise. As a result, the natural convective heat transfer characteristics of the ferrofluid for a concentric annuli were increased with the rise of the revolution and magnetic field strength due to the increased heat dissipation between hot side and cold side of the concentric annuli.

Daily Variation of Heat Budget Balance in the Gangjeong-Goryung Reservoir for Summertime - Concerning around the Rate of Heat Storage - (낙동강 강정고령보의 여름철 열수지 일변화 - 열 저장량 변동을 중심으로 -)

  • Kim, Seong-Rak;Cho, Chang-Bum;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.24 no.6
    • /
    • pp.721-729
    • /
    • 2015
  • Surface heat balance of the Gangjeong-Goryung Reservoir is analyzed for 12-17 August 2013. Each flux elements at the water surface is derived from the special field observations with application of an aerodynamical bulk method for the turbulent heat fluxes and empirical formulae for the radiation heat fluxes. The rate of heat storage in the reservoir is estimated by using estimated by surface heating rate and the vertical water temperature data. The flux divergence of heat transport is estimated as a residual. The features of the surface heat balance are almost decided by the latent heat flux and the solar radiation flux. On average for 12-17 August 2014 in the Gangjeong- Goryung Reservoir, if one defines the insolation at the water surface as 100 %, 94 % is absorbed in the reservoir; thereafter the reservoir loses about 30~50% by sensible heat, latent heat and net long-wave radiation. The residue of 50~80 % raises the water temperature in the reservoir or transported away by the river flow during the daytime.

Dispersion Analysis of Surface Discharged Heat Water In Shallow Coastal Area (천해역에서의 표층온배수 확산해석)

  • 서승원;김덕호
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.7 no.4
    • /
    • pp.340-345
    • /
    • 1995
  • Dispersion characteristics of surface discharge heat water in shallow region are investigated for coastal power plant with nearly constant depth of 20 meters by observing the seasonal depthwide temperature in several stations, which give or precise horizontal distribution and vertical structure of heat water. Surface discharged heat water in shallow coast in the Yellow Sea relies mainly on ambient tidal flow. so it behaves as free jet when the ambient now is strong and shows plumelike behavior during stagnant tide. According to observation the neat field region is estimated as 200-300 meters and shows distinct vertical profile and exponentially decreasing pattern from discharge point for this region. But there are no remarkable vertical distortion of temperature beyond 800 meters even though it is discharged from surface. Characteristic length scale model, CORMIX3, is applied and compared with the field date Overall tendency of CORMIX3 results resemble well with field data especially in near field and intermediate region.

  • PDF

Assessment on Applicability of Recycled Aggregates for Backfill Materials of Underground Transmission Lines Based on Field Demonstration Tests (지중 송전관로 되메움용 순환골재의 현장실증시험을 통한 적용성 평가)

  • Kang, Sung-Chur;Lee, Kang-Ryel;Ahn, Tae-Bong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.1
    • /
    • pp.72-83
    • /
    • 2015
  • Underground transmission lines always generate heat and transmit heat through surrounding backfill materials. Therefore, in the design of power lines it becomes a very crucial factor to transfer heat effectively into the neighbouring soils. In this study, in order to enhance field applicability of recycled aggregates for backfill material of transmission lines, quality criteria and construction criteria were proposed, and thermal stability of power lines through field demonstration tests were analyzed. In the field tests, two types of recycled aggregates and sand which is currently used for backfilling were compared in terms of thermal behaviour. Test results showed that recycled aggregates represented similar trends with sand in temperature and moisture content corresponding to time lapse and distance from the heat source. Consequently, recycled aggregates can be utilized for backfill materials of underground transmission lines as a substitute material of sands.

USING MODIS DATA TO ESTIMATE THE SURFACE HEAT FLUXES OVER TAIWAN'S CHIAYI PLAIN

  • Ho, Han-Chieh;Liou, Yuei-An;Wang, Chuan-Sheng
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.317-319
    • /
    • 2008
  • Traditionally, it is measured by using basin or empirical formula with meteorology data, while it does not represent the evaportransporation over a regional area. With the advent of improved remote sensing technology, it becomes feasible to assess the ET over a regional scale. Firstly, the IMAGINE ATCOR atmospheric module is used to preprocess for the MODIS imagery. Then MODIS satellite images which have been corrected by radiation and geometry in conjunction with the in-situ surface meteorological measurement are used to estimate the surface heat fluxes such as soil heat flux, sensible heat flux, and latent heat flux. In addition, the correlation coefficient between the derived latent heat and the in-situ measurement is found to be over 0.76. In the future, we will continue to monitor the surface heat fluxes of paddy rice field in Chiayi area.

  • PDF

Heat Treatments Used in the Dairy Industry (유제품에 이용되는 주요 열처리 조건)

  • Oh, Sejong
    • Journal of Dairy Science and Biotechnology
    • /
    • v.38 no.4
    • /
    • pp.230-236
    • /
    • 2020
  • Heat treatment is a fundamental processing technology in the dairy industry. The main purpose of heat treatment is to destroy pathogenic and spoilage promoting microorganisms to ensure milk safety and shelf life. Despite the development of alternative technologies, such as high-pressure processing and pulse field technology for microbial destruction, heat treatment is widely used in the dairy industry and in other food processes to destroy microorganisms. Heat treatment has contributed greatly to the success of food preservation since Pasteur's early discovery that heat treatment of wine and beer could prevent their deterioration, and since the introduction of milk pasteurization in the 1890s. In Korea, food labeling standards do not stratify heat treatments into low temperature, high temperature, and ultra-high temperature methods. Most milk is produced in Korea by pasteurization, with extended shelf life (ESL : 125--140℃ / 1-10 s). Classification based on temperature (i.e. low, high, and ultra-high), is meaningless.

Prediction of Characteristics for the Air-side Particulate Fouling in Finned-Tube Heat Exchangers of Air Conditioners used in the Field (실공간 사용 공기조화기용 열교환기의 공기측 파울링 특성 예측)

  • Ahn, Young-Chull;Jung, Sung-Hak;Hwang, Yu-Jin;Lee, Chang-Gun;Kim, Doo-Hyun;Jung, Seong-Ir;Lee, Jae-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.8
    • /
    • pp.563-568
    • /
    • 2007
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performances of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. An empirical modeling equation has been derived from the experimental results using accelerated tests and it showed good predictions of the fouling characteristics of the slitted finned tube heat exchangers. However the modeling equation predicts only the fouling characteristics of new heat exchangers and it can not predicts fouling characteristics obtained from actual field data which contains the effect of hydrophilicity deterioration. Therefore an modified modeling equation is proposed and it shows good predictions of the actual fouling characteristics of finned-tube heat exchangers.

Research on Performance of Large Rotor-type Heat Recovery Exchanger using CFD Analysis on Surface Corrugation (요철형상의 CFD 해석을 통한 대용량 로타형 폐열회수열교환기 성능에 관한 연구)

  • Kim, Dong-Gyu;Ha, Byeong-Yong;Kim, Kun-Oh;Kum, Jong-Soo;Jeong, Seok-Kwon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.12
    • /
    • pp.875-880
    • /
    • 2012
  • The field of the large volume heat exchanger for wasted heat recovery ventilation system is being expanded enormously seeing as the fact that the quantity of reducing energies are huge due to the large volume heat exchanger for wasted heat recovery system at large buildings and factories, which consume large amount of energies while it has been arising huge amount of losses in Korea because of the lack of technology. To develop large volume waste heat recovery heat exchanger, rotor type heat exchanger was simulated for the surface corrugation. Based on the simulation results produced $30,000m^3/h$ grade waste heat recovery, heat exchanger was performed for the actual experiment. In addition, performance tests exceed the capacity of a large waste heat recovery heat exchanger performance test methods proposed.

Effects of Gaussian Magnetic Therapy on Body Temperature in Elderly Women with Delayed Onset Muscle Soreness (노년기 지연성 근육통증에 대한 가우스 자기장 치료가 신체 체열 변화에 미치는 영향)

  • Shin, Won
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.7
    • /
    • pp.538-545
    • /
    • 2019
  • The purpose of this study was to analyze the change of body temperature and pain by application of Gaussian magnetic for the elderly delayed muscle pain. For the purpose, we selected 15 elderly women(age;$69.47{\pm}1.60$) and conducted repeated experiments. The Gaussian magnetic field area was divided into three areas (1000G, 1500G, 2000G). The applying arbitrarily manufactured magnetic field wristbands changes of body heat and pain before and after wearing Gaussian magnetic were measured and collected data were analyzed using SPSS 19.0. To examine the pre-and post-treatment differences by treatment areas, we conducted paired t-test. Group differences and interaction effects were analyzed using two-way ANOVA and Duncan post hoc tests. The significance level was set to ${\alpha}=.05$. The results are as follows. The change of body heat by the Gaussian magnetic field area showed significant differences in all three groups(P<.05). There were also significant differences in the results of group interactions and in the delayed muscle pain scale between groups(P<.05). The area with the largest difference appeared in the area of 1500G field. The 1000G-1500G Gauss field is considered to be the most ideal magnetic field for body heat and muscle pain changes. In conclusion, the Gaussian magnetic field of 1000G-1500G may affect body temperature and muscle pain in the elderly, and may have a significant impact on the quality of life in old age.