• Title/Summary/Keyword: Field exposure

Search Result 1,027, Processing Time 0.025 seconds

Evaluation of Angle Dependence on Positional Radioisotope Source Detector using Monte Carlo Simulation in NDT (몬테카를로 시뮬레이션을 이용한 방사선원 위치 검출기의 각도의존성 연구)

  • Han, Moojae;Heo, Seunguk;Shin, Yohan;Jung, Jaehoon;Kim, Kyotae;Heo, Yeji;Lee, Deukhee;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.141-146
    • /
    • 2019
  • Radiation sources used in the field of industrial non-destructive pose a risk of exposure due to ageing equipment and operator carelessness. Thus, the need for a safety management system to trace the location of the source is being added. In this study, Monte Carlo Simulation was performed to analyse the angle dependence of the unit-cell comprising the line-array dosimeter for tracking the location of radiation sources. As a result, the margin of error for the top 10% of each slope was 5.90% at $0^{\circ}$, 8.08% at $30^{\circ}$, and 20.90% at $60^{\circ}$. The ratio of the total absorbed dose was 83.77% at $30^{\circ}$ and 53.36% at $60^{\circ}$ based on $0^{\circ}$(100%) and showed a tendency to decrease with increasing slope. For all gradients, the maximum number was shown at $30^{\circ}$ No. 9 pixels, and for No. 10, there was a tendency to drop 7.24 percent. This study has shown a large amount of angle dependence, and it is estimated that the proper distance between the source and line-array dosimeters should be maintained at a distance of not less than 1 cm to reduce them.

Requirement for Amendment of the Law on the Phrase 'Instruction of Physicians or Dentists' in Medical Service Technologist, etc Act (의료기사 등에 관한 법률에서 '의사 또는 치과의사의 지도' 문구에 대한 법률 개정 요구도)

  • Lim, Woo-Taek;Lim, Cheong-Hwan;Joo, Young-Cheol;Hong, Dong-Hee;Jung, Hong-Ryang;Kim, Eun-Hye;Yoon, Yong-Su;Jung, Young-Jin;Choi, Ji-Won
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.503-512
    • /
    • 2021
  • The purpose of this study is to check the extent to which "instruction of physician or dentist" defined in the Medical Service Technologists, etc. Act is applied in relation to radiography examination procedures for radiological technologists. In addition, it is intended to present basic data on the requirement to revise the Medical Service Technologists, etc. Act in the radiological technologist's duty area and scope of work, The subjects of this study were radiological technologists with license, and the response data were collected after sending the questionnaire link written on the online questionnaire form. The final number of respondents were 1,018, and the response rate was 6.8%. Most of the negative responses were "I have never received 'instruction' for radiologic examination by a physician or dentist, including a radiologist in a medical environment." There were a high perception that "the professionalism in radiation examination on radiological technologists are higher than that of a physician or dentist." They answered that the current continuing education has a great impact on maintaining and continuing professionalism and learning new knowledge in the radiology field. In addition, the radiological technologists provide a very high level of education in areas related to radiography procedure ethics such as patient care, patient safety, and patient privacy protection, as well as specialized fields such as radiation-related examination methods, radiography examination dose, and patient exposure dose. Radiological technologists replied that they were receiving it consistently. In conclusion, in the current medical environment, the 'instruction' of a physician or dentist cannot be seen as being realistically performed. The phrase 'instruction' of a physician or dentist as defined in the Medical Service Technologists, etc. Act is considered inappropriate in respect of the fact that the state recognizes the qualifications of the medical service technologist through a license. It is thought that revision to a new term suitable for the current medical environment is necessary.

Applying Rosen-type PZT plasma generation device for medical applications (로젠형 압전변압기를 적용한 의료융합 플라즈마기기)

  • Lee, Kang-yeon;Jung, Byung-Geun;Park, Jeong-sook;Park, Ju-Hoon;Jeong, Byeong-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.1
    • /
    • pp.243-250
    • /
    • 2021
  • In the medical field, applications of plasma are applied sterilize instruments mainly but with the advent of bio-plasma technology, the scope of application is expanding. Recently, In addition, high-density miniaturization with handheld is required for sophisticated procedures when irradiated directly or treated with non-standard conditions. Rosen-type PZT is a device with a structure that generates high voltage plasma by achieving voltage transformation through electro-mechanical coupling using piezoelectric effect.and is used in portable plasma generating devices as an advantage to increase energy density relatively. In this paper, Rosen-type PZT was modeled using equivalent circuits and was carried out and a plasma generating device for medical application was designed and prototype tested. Prototype plasma generating device generates an output voltage of 5.8 kV with 12V input power and is designed to operate at high voltage by applying the half-bridge topology power converter. The results of the study confirmed the availability of various medical devices, such as plasma jets or direct exposure equipment.

A Study on the Usefulness of Copper Filter in Single X-ray Whole Spine Lateral using 3D Printer (단일조사 whole spine Lateral 검사에서 3D 프린터로 제작한 구리 필터 유용성 연구)

  • Kwon, Kyung-Tae;Yoon, Dayeon;Shin, Rae-Un;Han, Bong-Ju;Yoon, Myeong-Seong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.899-906
    • /
    • 2020
  • The WSS lateral examination is important for diagnosing spinal disorders. Recently, long-length detectors for large-area diagnose have been popularized to effectively reduce the exposure dose and examination time. It can be applied very efficiently to examinations of patients with high risk of falls, children, and adolescents. However, since the image is acquired through a single irradiation, the volume of cervical vertebra is relatively smaller than the lumbar due to the geometrical anatomy of the spine. Therefore, this study intends to fabricate an additional filter using 3D printing technology and copper filament to obtain uniform image quality in the WSS lateral examination and to analyze the results. 3D printing technology is able to easily print a desired shape, so it is widely used in the entire industrial field, and recently, a copper filament has been developed to confirm the possibility as an additional filter. In the WSS lateral examination, CNR and SNR were excellently measured when the additional filter was applied, confirming the possibility of using the additional filter.

Evaluation of Scattered Rays of Jelly Type Shielding Body by L-spine AP using X-ray (L-Spine X-선 촬영에서의 Jelly type 차폐체의 산란선 차폐평가)

  • Jang, Hui-Min;Kim, Do-Gwon;Kim, Hyeong-Bin;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.907-913
    • /
    • 2020
  • There have been continuous controversies on medical X-ray protection and numerous researchers have been trying to prevent unnecessary exposure to radiation. As X-ray passes through the patient and obtains an image, it creates scattered ray due to interactions such as photoelectric effect and Compton scattering with the subject. As a result, both medical radiation staff and patient are exposed to unnecessary radiation on areas other than the target area. In response, this study will be assuming a body of a female, radiating X-ray on the phantom under the conditions of lumbar spine AP test, and measuring scattered ray around breasts and thyroid glands. Then, The experiment results were as follows. After application of non-shielding material, the average of scattered ray was 0.88 mR in thyroid measurement, 3.34 mR, Lt Axillary 3.54 mR, and Rt Axillary 3.03 mR in mamonary measurement but, After application of shielding material, the average of scattered ray was 0.16 mR in thyroid measurement, 0.60 mR, Lt Axillary 0.64 mR, and Rt Axillary 0.54 mR in mamonary measurement showing average scattered ray protection effect of about 82%. This study suggested the manufacturing method of a Jelly-type shielding material, identified the possibilities of researches on mixing various substances with radiology field, and verified the usability of the Jelly-type shielding material as a substitute for existing protection tools.

TLC, HPTLC FINGERPRINTING AND ACUTE ORAL TOXICITY EVALUATION OF HABB-E-AZARAQI: A NUX-VOMICA-BASED TRADITIONAL UNANI FORMULATION

  • Ara, Shabnam Anjum;Viquar, Uzma;Zakir, Mohammed;Husain, Gulam Mohammed;Naikodi, Mohammed Abdul Rasheed;Urooj, Mohd;Kazmi, Munawwar Husain
    • CELLMED
    • /
    • v.11 no.3
    • /
    • pp.13.1-13.9
    • /
    • 2021
  • Background and Objective: Nux-vomica based traditional Unani formulation, Habb-e-Azaraqi (HAZ) is an important drug used by Unani physicians since several decades. It possesses Muqawwi-i-A'sab (nervine tonic), Muharrik-i-A'sab (nervine stimulant) properties and is an effective treatment option for diseases like Laqwa (facial palsy), Falij (paralysis), Niqris (gout) and Waja'al-Mafasil (arthritis) etc. The aim of the study is to access and provide information of HAZ for its TLC, HPTLC Fingerprinting defining its clear qualitative perspective and acute oral toxicity evaluation for its safety assessment which was not done earlier, thus contributing in the field of research. Materials and Methods: The chief ingredient, nux-vomica was detoxified as per method mentioned in Unani Pharmacopeia before its use in formulation. TLC and HPTLC was developed under four detection system i.e., UV 366nm, UV 254nm, exposure to iodine vapours and after derivatization with anisaldehyde sulphuric acid. Acute toxicity studies were performed as per OECD Guidelines 425 at a limit dose of 2000 mg/kg. Observations were done for signs of toxicity, body weight, and feed consumption at regular intervals followed by haematological and biochemistry evaluation. Results: The generated data proved the authenticity and established the TLC and HPTLC profile of the formulation. Acute toxicity revealed no significant differences in HAZ-treated animals with respect to body weight gain, feed consumption, haematology, clinical biochemistry evaluation. No significant gross pathological observation was noticed in necropsy. Conclusion: Data of the present study is substantial and scientific proof of HAZ in terms of standardization and toxicity study that can be utilize in future research activities.

A Study on Regulations Through Analysis of the Status of Radiation Workers and Related Workers and Satisfaction Survey in the Radiology Department (방사선작업종사자 및 방사선관계종사자의 현황 분석과 교내 실습 만족도 조사를 통한 방사선(학)과의 규제에 대한 고찰)

  • Jung, Hyunseo;Lee, Yong-Ki;Ahn, Sung-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.327-334
    • /
    • 2022
  • In this study, the purpose of this study was to conduct a basic study on the effectiveness and feasibility of the regulation of the Nuclear Safety Act for the department of radiology by examining the questionnaire on the satisfaction of on-campus practice while attending the department of radiology and the current status of radiation workers and radiation related workers. As for the satisfaction of the workers who were designated as frequent visitors while attending the department of radiology and did not handle and operate the radiation generator during on-campus training, 34.62% of the workers answered 'not satisfied'. On the other hand, 50% of workers who were designated as radiation workers while attending school or who were enrolled in school before the regulation of the nuclear safety act and handled and operated radiation generators were 'satisfied' at 50%. In addition, the annual exposure dose of radiation workers in educational institutions was found to be less than 0.05 mSv. If you look at the trends of radiation workers and radiation workers, it can be seen that students who graduate from the Department of Radiology find the most employment in the field dealing with diagnostic radiation generators registered as radiation workers among medical institutions. Therefore, by easing the regulations of the current Nuclear Safety Act or by amending the medical act and the rules on the safety management of diagnostic radiation generating devices, etc. It is presumed that something is necessary.

Effects of Endocrine Disrupting Chemicals on the Nervous System (내분비계 교란물질이 신경계에 미치는 영향)

  • Shin, Hyun Seung;Wi, Jae Ho;Lee, Seung Hyun;Choi, Soo Min;Jung, Eui-Man
    • Journal of Life Science
    • /
    • v.32 no.1
    • /
    • pp.70-77
    • /
    • 2022
  • Endocrine disrupting chemicals (EDCs) have been attracting significant attention in modern society, owing to the increased incidence rate of various diseases along with population growth. EDCs are found in many commercial products, including some plastic bottles and containers, detergents, liners of metal food cans, flame retardants, food, toys, cosmetics, and pesticides. EDCs have a hormonal effect on the human body, which disrupts the endocrine system, notably affecting sexual differentiation and normal reproduction, and can trigger cancer as well. Recently, the association between neurological diseases and EDCs has become a hot topic of research in the field of neuroscience. Considering that EDCs negatively affect not only neuronal proliferation and neurotransmission but also the formation of the neuronal networks, EDCs may induce neurodevelopmental disorders, such as autism spectrum disorders and attention-deficit/hyperactivity disorder as well as neurodegenerative diseases, including Parkinson's disease and Alzheimer's disease. In light of these potentially deleterious outcomes, important efforts have been underway to minimize the exposure to EDCs through appropriate regulations and policies around the world, but chemicals that have not yet been associated with endocrine disrupting properties are still in wide use. Therefore, more epidemiological investigations and research are needed to fully understand the effects of EDCs on the nervous system.

The Effect on Attention of College Students by Epidermal Cooling in Posterior and Lateral of Upper Cervix (경추부 후면 및 측면 피부 냉각 작용이 대학생의 주의력에 미치는 영향)

  • Chang, Ji Hong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.5
    • /
    • pp.328-334
    • /
    • 2022
  • The process that one may consciously focuses on necessary stimulation among tremendous amount of stimulation through human sensory systems is called attention in psychology. It is known that the attention can be affected by many factors such as room temperatures, humidity level, etc. In the field of sports science, ice packs are widely used for recovery from exercise fatigue providing fast heat transfer by conduction. However, the effect on attention by so-called iced-pack-cooling has not been tested. This research focuses on the attention levels when one is provided with a special cooling pad on their dorsal and lateral cervices. 40 subjects were divided into four groups and their attention level was evaluated based on the exposure conditions of combinations in reading and light walking with and without the cooling pad. The Frankfruter Aufmerksamkeits-Inventar, FAIR was used to evaluate the attention levels; the performance index, quality index, and continuity index consist of the FAIR test indicating the selectiveness of the attention, correctness of the attention, and maintaining term of the attention, respectively. Analysis of variance was carried out for those variables and post-hoc if applicable. When visual attention is constantly used for reading and studying, application of conductive heat transfer by the cooling pads is significantly helpful for improvement in selectiveness of the attention and maintaining terms of the attention levels. Also, light walking yielded improvement in selectiveness of the attention and maintaining terms of the attention levels; however one should presupposedly consider the loss of reading time.

Cold Hardiness Change in Solenopsis japonica (Hymenoptera: Formicidae) by Rapid Cold Hardening (급속내한성 유기에 의한 일본열마디개미(Solenopsis japonica)의 내한성 변화)

  • Park, Youngjin;Vatanparast, Mohammad;Lee, Jieun
    • Korean journal of applied entomology
    • /
    • v.60 no.2
    • /
    • pp.193-199
    • /
    • 2021
  • Solenopsis japonica, which is belonging to Formicidae in Hymenoptera, is a native ant species in Korea. However, it had not been studied for cold hardiness of S. japonica to understand on its overwintering mechanisms in field so far. Cold tolerance on developmental stages was measured at different cold temperature with various exposure times. Workers showed more survival at 5℃ and 10℃ compared with other stages and elevated cold tolerance when workers were exposed at 15℃ for more than 12h incubation as a rapid cold hardening (RCH) condition. RCH treatment not only increased survival of workers at cold temperatures, but also decreased supercooling point (SCP) and freezing point (FP). RCH group increased the survival rate by 44% at 10℃ compared with Non-RCH group. SCP and FP were depressed from -10.0 to -14.2℃ and from -11.3 to -15.3℃, respectively, after RCH treatment. Cold temperature increased expression level of cold- and stress-related genes such as glycerol kinase and heat shock protein. These results indicate unacclimated cold tolerance of S. japonica and its acclimation to low temperature by RCH.