• Title/Summary/Keyword: Field evaluation

Search Result 5,836, Processing Time 0.032 seconds

Evaluation of Radiation Exposure Dose for Examination Purposes other than the Critical Organ from Computed Tomography: A base on the Dose Reference Level (DRL) (전산화단층촬영에서 촬영 목적 부위와 주변 결정장기에 대한 피폭선량 평가: 선량 권고량 중심으로)

  • Lee, Seoyoung;Kim, Kyunglee;Ha, Hyekyoung;Im, Inchul;Lee, Jaeseung;Park, Hyonghu;Kwak, Byungjoon;Yu, Yunsik
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.121-129
    • /
    • 2013
  • In this study measured patient exposure dose for purpose exposure area and peripheral critical organs by using optically stimulated luminescence dosimeters (OSLDs) from computed tomography (CT), based on the measurement results, we predicted the radiobiological effects, and would like to advised ways of reduction strategies. In order to experiment, OSLDs received calibration factor were attached at left and right lens, thyroid, field center, and sexual gland in human body standard phantom that is recommended in ICRP, and we simulated exposure dose of patients in same condition that equal exposure condition according to examination area. Average calibration factor of OSLDs were $1.0058{\pm}0.0074$. In case of left and right lens, equivalent dose was measure in 50.49 mGy in skull examination, 0.24 mGy in chest, under standard value in abdomen, lumbar spine and pelvis. In case of thyroid, equivalent dose was measured in 10.89 mGy in skull examination, 7.75 mGy in chest, 0.06 mGy in abdomen, under standard value in lumber spine and pelvis. In case of sexual gland, equivalent dose was measured in 21.98 mGy, 2.37 mGy in lumber spine, 6.29 mGy in abdomen, under standard value in skull examination. Reduction strategies about diagnosis reference level (DRL) in CT examination needed fair interpretation and institutional support recommending international organization. So, we met validity for minimize exposure of patients, systematize influence about exposure dose of patients and minimize unnecessary exposure of tissue.

Using Spatial Data and Crop Growth Modeling to Predict Performance of South Korean Rice Varieties Grown in Western Coastal Plains in North Korea (공간정보와 생육모의에 의한 남한 벼 품종의 북한 서부지대 적응성 예측)

  • 김영호;김희동;한상욱;최재연;구자민;정유란;김재영;윤진일
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.4 no.4
    • /
    • pp.224-236
    • /
    • 2002
  • A long-term growth simulation was performed at 496 land units in the western coastal plains (WCP) of North Korea to test the potential adaptability of each land unit for growing South Korean rice cultivars. The land units for rice cultivation (CZU), each of them represented by a geographically referenced 5 by 5 km grid tell, were identified by analyzing satellite remote sensing data. Surfaces of monthly climatic normals for daily maximum and minimum temperature, precipitation number of rain days and solar radiation were generated at a 1 by 1 km interval by spatial statistical methods using observed data at 51 synoptic weather stations in North and South Korea during 1981-2000. Grid cells felling within a same CZU and, at the same time, corresponding to the satellite data- identified rice growing pixels were extracted and aggregated to make a spatially explicit climatic normals relevant to the rice growing area of the CZU. Daily weather dataset for 30 years was randomly generated from the monthly climatic normals of each CZU. Growth and development parameters of CERES-rice model suitable for 11 major South Korean cultivars were derived from long-term field observations. Eight treatments comprised of 2 transplanting dates $\times$ 2 cropping systems $\times$ 2 irrigation methods were assigned to each cultivar. Each treatment was simulated with the randomly generated 30 years' daily weather data (from planting to physiological maturity) for 496 land units in WCP to simulate the growth and yield responses to the interannual climate variation. The same model was run with the input data from the 3 major crop experiment stations in South Korea to obtain a 30 year normal performance of each cultivar, which was used as a "reference" for comparison. Results were analyzed with respect to spatial and temporal variation in yield and maturity, and used to evaluate the suitability of each land unit for growing a specific South Korean cultivar. The results may be utilized as decision aids for agrotechnology transfer to North Korea, for example, germplasm evaluation, resource allocation and crop calendar preparation.

Study on the Education Curriculum and Clinical Practice of Medical Technologists (임상병리사 교육과정 및 임상실습에 대한 연구)

  • Yang, Byoung-Seon;Choi, Se-Mook;Shim, Moon-Jung;Kim, Chung-Hwan;Bae, Hyung-Joon;Yook, Keun-Dol;Kim, Yoon-Sik;Lim, Yong;Kang, Ji-Hyuk;Kim, Hong-Sung;Kim, Dong-Chan;Shin, Gyeonghee;Lee, Sang-Hee
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.3
    • /
    • pp.320-330
    • /
    • 2018
  • This study analyzed the curriculum and clinical practicum of the department of clinical laboratory science in Korea. The 2017 educational curricula of all 3-year and 4-year universities were analyzed. Clinical practice was conducted by a questionnaire. As a result of curriculum analysis, the 3-year curriculum was able to grasp the curriculum that focused on the national examinations of medical technologists, and the 4-year curriculum was open to a variety of subjects reflecting the changes in the future, but only at a few universities. In addition, the autonomous enrollment application made it possible to take a national examination without enrolling in courses that students find difficult in major courses. In the case of clinical practice, it was difficult to standardize in various practical institutes, practice periods, and practice credits. Therefore, it will be necessary to standardize the composition of the credits according to the duration of clinical practice and the duration of education. Moreover, is necessary to revise the curriculum in consideration of medical technologist job analysis and clinical field, and it will be necessary to standardize the curriculum and clinical practice model through the Medical Technologist Evaluation Center.

A Study on the Optimum Design of Multiple Screw Type Dryer for Treatment of Sewage Sludge (하수슬러지 처리를 위한 다축 스크류 난류 접촉식 건조기의 최적 설계 연구)

  • Na, En-Soo;Shin, Sung-Soo;Shin, Mi-Soo;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.4
    • /
    • pp.223-231
    • /
    • 2012
  • The purpose of this study is to investigate basically the mechanism of heat transfer by the resolution of complex fluid flow inside a sophisticated designed screw dryer for the treatment of sewage sludge by using numerical analysis and experimental study. By doing this, the result was quite helpful to obtain the design criteria for enhancing drying efficiency, thereby achieving the optimal design of a multiple screw type dryer for treating inorganic and organic sludge wastes. One notable design feature of the dryer was to bypass a certain of fraction of the hot combustion gases into the bottom of the screw cylinder, by the fluid flow induction, across the delicately designed holes on the screw surface to agitate internally the sticky sludges. This offers many benefits not only in the enhancement of thermal efficiency even for the high viscosity material but also greater flexibility in the application of system design and operation. However, one careful precaution was made in operation in that when distributing the hot flue gas over the lump of sludge for internal agitation not to make any pore blocking and to avoid too much pressure drop caused by inertial resistance across the lump of sludge. The optimal retention time for rotating the screw at 1 rpm in order to treat 200 kg/hr of sewage sludge was determined empirically about 100 minutes. The corresponding optimal heat source was found to be 150,000 kcal/hr. A series of numerical calculation is performed to resolve flow characteristics in order to assist in the system design as function of important system and operational variables. The numerical calculation is successfully evaluated against experimental temperature profile and flow field characteristics. In general, the calculation results are physically reasonable and consistent in parametric study. In further studies, more quantitative data analyses such as pressure drop across the type and loading of drying sludge will be made for the system evaluation in experiment and calculation.

A Study on the Solubilizing and Emulsifying Action of Tocopheryl Acetate using Plant Surfactant (식물성계면활성제를 사용한 토코페릴아세테이트의 가용화와 유화력에 관한 연구)

  • Kim, In-Young;Bae, Bo-Hyeon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.893-905
    • /
    • 2020
  • This study is a study on solubilization and emulsifying power of tocopheryl acetate using vegetable surfactants. High purity polyglyceryl-10 isostearate and polyglyceryl-10 oleate were mixed to synthesize a vegetable surfactant with excellent solubilizing power and emulsifying power. The mixed raw material was named Solubil EWG-1100. The appearance of this raw material was a pale yellowish paste with a specific smell, specific gravity of 1.12, and acid value of 0.085. The HLB value of this surfactant was calculated by the Griffin's equation with an average value of 15.17. The behavior of this surfactant to solubilize tocopheryl acetate was mechanically verified. The performance of solubilization was evaluated by a method of visual evaluation and was measured by a transmittance rate at 650 nm using a UV spectrophotometer. As a result, in the formulation using 3% ethanol as a co-solvent, the concentration of surfactant was required to solubilize tocopheryl acetate was required about 5 times of natural surfactant. In the formulation without ethanol as a co-solvent, the concentration of surfactant was required to solubilize tocopheryl acetate required about 7 times of natural surfactant. In addition, the concentration of surfactant required to make an emulsifivation 10 % of tocopheryl acetate was 1 wt% of Solubil EWG-1100, and the emulsified particle size was 3.5 mm in cream formula. In order to obtain stable and fine emulsified particles, it was found that as the concentration of tocopheryl acetate increased, the concentration of Solubil EWG-1100 also was to increase. As a result of testing the solubilizing power of the surfactant according to the pH various change, it showed stable solubilizing power in the acidic region of pH=3.2, the neutral region of pH=7.0, and the alkaline region of pH=11.8. As application, based on these results, it is expected that it can be widely applied to the cosmetics field that develops skin care prescriptions, sensitive skin products, and heavy dry skin products.

A Study on Process Optimization for CSOs Application of Horizontal Flow Filtration Technology (수평흐름식 여과기술의 CSOs 적용을 위한 공정 최적화 연구)

  • Kim, Jae-Hak;Yang, Jeong-Ha;Lee, Young-Shin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.56-63
    • /
    • 2018
  • The management of Combined Sewer Overflows(CSOs) and Separated Sewer Overflows(SSOs) discharge directly to the effluent system in an untreated state, which occurs when the facility capacity is exceeded due to heavy rain, has become an important issue in recent years as the heavy rain becomes a regular phenomenon. Despite the continuous development of filtration technology, targeting densely populated urban areas, CSOs are rarely applied. Therefore, this study was carried out to optimize the process to apply CSOs in a pilot-scale horizontal flow filtration system with a rope-type synthetic fiber. The research was carried out in two steps: a preliminary study using artificial samples and a field study using sewage. In the preliminary study using an artificial sample, head loss of the filter media itself was analyzed to be approximately 1.1cm, and the head loss was increased by approximately 0.1cm as the linear velocity was increased by 10m/hr. In addition, the SS removal efficiency was stable at 81.4%, the filtration duration was maintained for more than 6 hours, and the average recovery rate of 98% was obtained by air backwashing only. In the on-site evaluation using sewage, the filtration duration was approximately 2 hours and the average removal efficiency of 83.9% was obtained when belt screen (over 450 mesh) was applied as a pre-treatment process to prevent the premature clogging of filter media. To apply the filtration process to CSOs and SSOs, it was concluded that the combination with the pre-treatment process was important to reinforce the hydraulic dimension for the stable maintain of operation period, rather than efficiency. Compared to the dry season, the quality of incoming sewage was lower in the rainy season, which was attributed to the characteristics of the drainage area with higher sanitary sewerage. In addition, the difference in removal efficiency according to the influent quality of the wet season and dry season was small.

Bioactivity of the Extract of Coptis chinensis: In-vitro Antifungal Activity against Phytophthora capsici and Growth-promotion Effect in Red-pepper (황련 추출물의 고추역병에 대한 In-vitro 항진균 활성 및 고추 생육촉진 효과)

  • Ahn, Seon-Mi;Lee, Dong-Sin;Kim, Mi-Sun;Choi, Su-Ji;Choi, Chung-Sik;Lee, Jung-Bok;Jang, Han-Su;Sohn, Ho-Yong
    • Microbiology and Biotechnology Letters
    • /
    • v.37 no.3
    • /
    • pp.280-286
    • /
    • 2009
  • To investigate anti-phytopathogenic fungal activity of Coptis chinensis, the methanol extract and its organic solvent fractions were prepared. Using the extract and the fractions, in-vitro spore-germination inhibition and mycelial-growth inhibition activities were evaluated against Colletotrichum gloeosporioides, Phytohpthora capsici, Pyricularia grisea, Rhizoctonia solani, Botryosphaeri dothidea, Glomerella cingulata, respectively. Treatment of the methanol extract (500 mg/mL) into the spore of phytopathogenic fungi completely inhibited germinations for 5 days, except B. dothidea, and showed strong antifungal activities against P. grisea and B. cinerea, and antioomycetes activity against P. capsici. The minimal growth inhibition concentrations of the methanol extract against P. grisea, B. cinerea and P. capsici were 300, 300, and 500 mg/mL, respectively. For practical application of C. chinensis in red-pepper field, the hot-water extract (1,000 mg/mL) was prepared in commercial facility, after evaluation of heat stability and solvent-extraction yields of antifungal substances. The 3-times leaf-spray of the extract from June to August, 2008 did not show any deleterious effect to red-pepper. In fact, the leaf-spray promoted plant growth including leaf, root and fruit. The average weight and rind of each fruit were increased to 119% and 117% comparison to those of without treatments. Our results suggest that C. chinensis is a useful source for control of red-pepper diseases and plant growth.

Production of Alternative Coagulant Using Waste Activated Alumina and Evaluation of Coagulation Activity (폐촉매 부산물로부터 대체 응집제 제조 및 응집성능 평가)

  • Lee, Sangwon;Moon, Taesup;Kim, Hyosoo;Choi, Myungwon;Lee, Deasun;Park, Sangtae;Kim, Changwon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.7
    • /
    • pp.514-520
    • /
    • 2014
  • In this study, the production potential of alternative coagulant ($Al_2(SO_4)_3$ solution) having the identical coagulation activity with respect to the commercial coagulant was investigated. The raw material of alternative coagulant was a spent catalyst including aluminium (waste activated alumina) generated in the manufacturing process of the polymer. The alternative coagulant was produced through a series of processes: 1) intense heat and grinding, 2) chemical polymerization and substitution with $H_2SO_4$ solution, 3) dissolution and dilution and 4) settling and separation. To determine the optimal operating conditions in the lab-scale autoclave and dissolver, the content of $Al_2O_3$ in alternative coagulant was analyzed according to changes of the purity of sulfuric acid, reaction temperature, injection ratio of sulfuric acid and water in the dissolver. The results showed that the alternative coagulant having the $Al_2O_3$ content of 7~8% was produced under the optimal conditions such as $H_2SO_4$ purity of 50%, reaction temperature of $120^{\circ}C$, injection ratio of $H_2SO_4$ of 5 times and injection ratio of water of 2.3 times in dissolver. In order to evaluate the coagulation activity of the alternative coagulant, the Jar-test was conducted to the effluent in aerobic reactor. As a result, in both cases of Al/P mole of 1.5 and 2.0, the coagulation activity of the alternative coagulant was higher than that of the existing commercial coagulant. When the production costs were compared between the alternative and commercial coagulant through economic analysis, the production cost reduction of about 50% was available in the case of the alternative coagulant. In addition, it was identified that the alternative coagulant could be applied at field wastewater treatment plant without environmental problem through ecological toxicity testing.

Evaluation of Greenhouse Gas Emissions in Cropland Sector on Local Government Levels based on 2006 IPCC Guideline (2006 IPCC 가이드라인을 적용한 지자체별 경종부문 온실가스 배출량 평가)

  • Jeong, Hyun-Cheol;Kim, Gun-Yeob;Lee, Seul-Bi;Lee, Jong-Sik;Lee, Jung-Hwan;So, Kyu-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.5
    • /
    • pp.842-847
    • /
    • 2012
  • This study was conducted to estimate the greenhouse gas emissions on local government levels from 1990 to 2010 using 2006 IPCC guideline methodology. To calculate greenhouse gas emissions based on the 16 local governments, emission factor and scaling factor were used with default value and activity data came from the food, agricultural, forestry and fisheries statistical yearbook of MIFAFF (Ministry for Food, Agriculture, Forestry, and Fisheries). The total emissions in crop sector gradually decreased from 1990 to 2010 due to a decline in agricultural land and nitrogen fertilizer usage. The annual average emission of greenhouse gas was the highest in Jeonnam (JN) with 1,698 Gg $CO_2$-eq and following Chungnam (CN), Gyungbuk (GB), Jeonbuk (JB) and Gyunggi (GG). The sum of top-six locals emission had occupied 83.4% of the total emission in cropland sector. The annual average emissions in 1990 by applying 2006 IPCC guideline were approximately 43% less than the national greenhouse gas inventory by 1996 IPCC guideline. Jeonnam (JN) province occupied also the highest results of greenhouse gas emission estimated by gas types (methane, nitrous oxide and carbon dioxide) and emission sources such as rice cultivation, agricultural soil, field burning of crop residue and urea fertilizer.

Evaluation of a Water-based Bolus Device for Radiotherapy to the Extremities in Kaposi's Sarcoma Patients (사지에 발병한 카포시육종의 방사선치료를 위한 물볼루스 기구의 유용성 고찰)

  • Ahn, Seung-Kwon;Kim, Yong-Bae;Lee, Ik-Jae;Song, Tae-Soo;Son, Dong-Min;Jang, Yung-Jae;Cho, Jung-Hee;Kim, Joo-Ho;Kim, Dong-Wook;Cho, Jae-Ho;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.26 no.3
    • /
    • pp.189-194
    • /
    • 2008
  • Purpose: We designed a water-based bolus device for radiation therapy in Kaposi's sarcoma. This study evaluated the usefulness of this new device and compared it with the currently used rice-based bolus. Materials and Methods: We fashioned a polystyrene box and cut a hole in order to insert patient's extremities while the patient was in the supine position. We used a vacuum-vinyl based polymer to reduce water leakage. Next, we eliminated air using a vacuum pump and a vacuum valve to reduce the air gap between the water and extremities in the vacuum-vinyl box. We performed CT scans to evaluate the density difference of the fabricated water-based bolus device when the device in which the rice-based bolus was placed directly, the rice-based bolus with polymer-vinyl packed rice, and the water were all put in. We analyzed the density change with the air gap volume using a planning system. In addition, we measured the homogeneity and dose in the low-extremities phantom, attached to six TLD, and wrapped film exposed in parallel-opposite fields with the LINAC under the same conditions as the set-up of the CT-simulator. Results: The density value of the rice-based bolus with the rice put in directly was 14% lower than that of the water-based bolus. Moreover, the value of the other experiments in the rice-based bolus with the polymer-vinyl packed rice showed an 18% reduction in density. The analysis of the EDR2 film revealed that the water-based bolus shows a more homogeneous dose plan, which was superior by $4{\sim}4.4%$ to the rice-base bolus. The mean TLD readings of the rice-based bolus, with the rice put directly into the polystyrene box had a 3.4% higher density value. Moreover, the density value in the case of the rice-based bolus with polymer-vinyl packed rice had a 4.3% higher reading compared to the water-based bolus. Conclusion: Our custom-made water-based bolus device increases the accuracy of the set-up by confirming the treatment field. It also improves the accuracy of the therapy owing to the reduction of the air gap using a vacuum pump and a vacuum valve. This set-up represents a promising alternative device for delivering a homogenous dose to the target volume.