• Title/Summary/Keyword: Field correction

Search Result 743, Processing Time 0.031 seconds

Body Temperature Monitoring Using Subcutaneously Implanted Thermo-loggers from Holstein Steers

  • Lee, Y.;Bok, J.D.;Lee, H.J.;Lee, H.G.;Kim, D.;Lee, I.;Kang, S.K.;Choi, Y.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.2
    • /
    • pp.299-306
    • /
    • 2016
  • Body temperature (BT) monitoring in cattle could be used to early detect fever from infectious disease or physiological events. Various ways to measure BT have been applied at different locations on cattle including rectum, reticulum, milk, subcutis and ear canal. In other to evaluate the temperature stability and reliability of subcutaneous temperature (ST) in highly fluctuating field conditions for continuous BT monitoring, long term ST profiles were collected and analyzed from cattle in autumn/winter and summer season by surgically implanted thermo-logger devices. Purposes of this study were to assess ST in the field condition as a reference BT and to determine any location effect of implantation on ST profile. In results, ST profile in cattle showed a clear circadian rhythm with daily lowest at 05:00 to 07:00 AM and highest around midnight and rather stable temperature readings (mean${\pm}$standard deviation [SD], $37.1^{\circ}C$ to $37.36^{\circ}C{\pm}0.91^{\circ}C$ to $1.02^{\circ}C$). STs are $1.39^{\circ}C$ to $1.65^{\circ}C$ lower than the rectal temperature and sometimes showed an irregular temperature drop below the normal physiologic one: 19.4% or 36.4% of 54,192 readings were below $36.5^{\circ}C$ or $37^{\circ}C$, respectively. Thus, for BT monitoring purposes in a fever-alarming-system, a correction algorithm is necessary to remove the influences of ambient temperature and animal resting behavior especially in winter time. One way to do this is simply discard outlier readings below $36.5^{\circ}C$ or $37^{\circ}C$ resulting in a much improved mean${\pm}$SD of $37.6^{\circ}C{\pm}0.64^{\circ}C$ or $37.8^{\circ}C{\pm}0.55^{\circ}C$, respectively. For location the upper scapula region seems the most reliable and convenient site for implantation of a thermo-sensor tag in terms of relatively low influence by ambient temperature and easy insertion compared to lower scapula or lateral neck.

Performance Improvement of Near Earth Space Survey (NESS) Wide-Field Telescope (NESS-2) Optics

  • Yu, Sung-Yeol;Yi, Hyun-Su;Lee, Jae-Hyeob;Yim, Hong-Suh;Choi, Young-Jun;Yang, Ho-Soon;Lee, Yun-Woo;Moon, Hong-Kyu;Byun, Yong-Ik;Han, Won-Yong
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.2
    • /
    • pp.153-160
    • /
    • 2010
  • We modified the optical system of 500 mm wide-field telescope of which point spread function showed an irregularity. The telescope has been operated for Near Earth Space Survey (NESS) located at Siding Spring Observatory (SSO) in Australia, and the optical system was brought back to Korea in January 2008. After performing a numerical simulation with the tested value of surface figure error of the primary mirror using optical design program, we found that the surface figure error of the mirror should be fabricated less than root mean square (RMS) $\lambda$/10 in order to obtain a stellar full width at half maximum (FWHM) below $28\;{\mu}m$. However, we started to figure the mirror for the target value of RMS $\lambda$/20, because system surface figure error would be increased by the error induced by the optical axis adjustment, mirror cell installation, and others. The radius of curvature of the primary mirror was 1,946 mm after the correction. Its measured surface figure error was less than RMS $\lambda$/20 on the table of polishing machine, and RMS $\lambda$/15 after installation in the primary mirror cell. A test observation performed at Daeduk Observatory at Korea Astronomy and Space Science Institute by utilizing the exiting mount, and resulted in $39.8\;{\mu}m$ of stellar FWHM. It was larger than the value from numerical simulation, and showed wing-shaped stellar image. It turned out that the measured-curvature of the secondary mirror, 1,820 mm, was not the same as the designed one, 1,795.977 mm. We fabricated the secondary mirror to the designed value, and finally obtained a stellar FWHM of $27\;{\mu}m$ after re-installation of the optical system into SSO NESS Observatory in Australia.

High-Resolution Seismic Reflection Profiling on Land with Hydrophones Employed in the Stream-Water Driven Trench (하천수유입과 하이드로폰을 이용한 육상 고분해능 탄성파반사법탐사)

  • Kim Ji-Soo;Han Su-Hyung;Kim Hak-Soo;Choi Won-Suk;Jung Chang-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.4 no.4
    • /
    • pp.133-144
    • /
    • 2001
  • An effective seismic reflection technique for mapping the cavities and bedrock surface in carbonate rocks is described. The high resolution seismic reflection images were successfully registered by using the hydrophones employed in the stream-water driven trench, and were effectively focused by applying optimal data processing sequences. The strategy included enhancement of the signal interfered with the large-amplitude scattering noise, through pre- and post stack processing such as time-variant filtering, bad-trace editing, residual statics, velocity analysis, and careful muting after NMO (normal moveout) correction. The major reflections including the bedrock surface were mapped with the desired resolution and were correlated to the seismic crosshole tomographic data. Shallow major reflectors could be identified and analyzed on the AGC (auto gain control)-applied field records. Three subhorizontal layers were identified with their distinct velocities; overburden (<3000 m/s), sediments (3000-4000 m/s), limestone bedrock (>4000 m/s). Taking into account of no diffraction effects in the field records, gravel-rich overburdens and sediments are considered to be well sorted. Based on the images mapped consistently on the whole survey line and seismic velocity increasing with depth, this area probably lacks in sizable cavities (if any, no air-filled cavities).

  • PDF

Hydrologic Analysis of the September 1990 Extreme Flood Occurred on the Chungju Dam Basin (충주(忠州)댐 유역(流域) 1990년(年) 9월(月) 대홍수(大洪水)의 수문학적(水文學的) 분석(分析))

  • Ko, Seok Ku;Lee, Hee Sung;Jeong, Dong Kug;Jung, Jae Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.4_1
    • /
    • pp.107-119
    • /
    • 1992
  • A heavy storm hit the central part of the Korean Peninsula especially on the Chungju Dam Basin from the 9th to 12th of September 1990. The Chungju multipurpose dam is the largest water project in Korea completed in 1986. The storm recorded a peak inflow of about $21,000m^3/sec$ at the dam site which is equivalent to 500 to 1000 years recurring frequency according to the designed concept. Extensive hydrological analyses including field investigation were performed to identify the storm. The result of the field investigation showed that 6 gages among the 22 telemetering rain-gages located in the basin were proved to be out-of-normal operation during the storm. The corrected basin average rainfall was estimated to be 458.6 mm ranging from 206 to 665 mm. The correction of the rainfall depth included the adjustment of the rainfall depths of the 6 gages using the Kriging interpolation technique, and adjustment according to the heights of the gage mouths. For the maintenance and operation of the Chungju Dam, new design floods were suggested from the trend analysis which showed that the design flood have to be increased because of the increasing tendency of the annual flood peaks.

  • PDF

Estimation of Suspended Sediment Concentration in Small Stream with Acoustic Backscatter from Horizontal ADCP based on Real-Scale Field Experiment (실규모 현장 실험 기반 H-ADCP 초음파 산란도 활용 소하천용 하천 부유사 농도 측정 기법 개발)

  • Seo, Kanghyeon;Kim, Dongsu;Son, Geunsoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.1023-1035
    • /
    • 2016
  • Suspended sediment concentration (SSC) is a crucial riverine parameter in terms that it can be utilized for analyzing sediment transport, stability assessment of river and structure and so on. However, in case of domestic, sediment discharge data are not enough because of using conventional sediment samplers. This study aimed at developing a practical technique for estimating suspended sediment concentration in high spatial and temporal resolution by building relationship between acoustic backscatter (or SNR) from H-ADCP with actually observed data using LISST-100X. In this regard, a dedicated correction algorithm was proposed particularly for the adapted H-ADCP (SonTek SL-3000). Then, a SNR-SSC relation was built based upon a real-scale field experiment, where both H-ADCP and LISST-100X were concurrently operated to observe SNR and SSC, respectively. The coefficient of determination for the developed regression equation of SNR-SSC relation was around 0.85~0.88, thereby the relation could be evaluated to be highly correlated. The result of this study might be potentially applied for real-time and simultaneous observation of SSC when H-ADCP could be applied.

The Evaluation of Application to MODIS LAI (Leaf Area Index) Product (MODIS LAI (엽면적지수) Product의 활용성 평가)

  • Ha, Rim;Shin, Hyung-Jin;Park, Geun-Ae;Hong, Woo-Yong;Kim, Seong-Jun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.11 no.2
    • /
    • pp.61-72
    • /
    • 2008
  • Leaf area index (LAI) is a key biophysical variable influencing land surface processes such as photosynthesis, transpiration and energy balance, and is a required input to estimate evapotranspiration in various ecological and hydrological models. The development of more correct and useful LAIs estimation techniques is required by these importance, but LAIs had been assumed in most LAI research through simple relations with the normalized difference vegetation index (NDVI) because the field measurement is difficult on wide area. This paper is to evaluate the MODIS LAI Product's practical use by comparing with LAIs that is derived from NOAA AVHRR NDVIs and the 2 years (2003-2004) measured LAIs of Korea Forest Research Institute in Gyeongancheon watershed (561.12 $Km^2$). As a result, the MODIS LAIs of deciduous forests showed higher values about 14 % and 15~30 % than the measured LAIs and NOAA LAIs. In the year of 2003, the MODIS LAIs in coniferous forests were 5 % higher than the measured LAIs, and showed about 7 % differences comparing with the NOAA LAIs except April. These differences come from the insufficient field data measured in partial points of the target area, and the extracted reference data from MODIS LAIs include the limits of spatial resolution and the error of incorrect land cover classification. Thus, using the MODIS data by the proper correction with the measured data can be useful as an input data for ecological and hydrological models which offers the vegetation information and simulates the water balance of a given watershed.

  • PDF

Advanced LWIR Thermal Imaging Sight Design (원적외선 2세대 열상조준경의 설계)

  • Hong, Seok-Min;Kim, Hyun-Sook;Park, Yong-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.3
    • /
    • pp.209-216
    • /
    • 2005
  • A new second generation advanced thermal imager, which can be used for battle tank sight has been developed by ADD. This system uses a $480\times6$ TDI HgCdTe detector, operating in the $7.7-10.3{\mu}m$ wavelength made by Sofradir. The IR optics has dual field of views such as $2.67\times2^{\circ}$ in NFOV and $10\times7.5^{\circ}$ in WFOV. And also, this optics is used for athermalization of the system. It is certain that our sensor can be used in wide temperature range without any degradation of the system performance. The scanning system to be able to display 470,000 pixels is developed so that the pixel number is greatly increased comparing with the first generation thermal imaging system. In order to correct non-uniformity of detector arrays, the two point correction method has been developed by using the thermo electric cooler. Additionally, to enhance the image of low contrast and improve the detection capability, we have proposed the new technique of histogram processing being suitable for the characteristics of contrast distribution of thermal imagery. Through these image processing techniques, we obtained the highest quality thermal image. The MRTD of the LWIR thermal sight shows good results below 0.05K at spatial frequency 2 cycles/mrad at the narrow field of view.

Program Development and Field Application for the use of the Integration Map of Underground Spatial Information (지하공간통합지도 활용을 위한 프로그램 개발 및 현장 적용)

  • Kim, Sung Gil;Song, Seok Jin;Cho, Hae Yong;Heo, Hyun Min
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.6
    • /
    • pp.483-490
    • /
    • 2021
  • Due to the recent increase in various problems from underground development in urbanized areas, accurate underground facility information management is highly needed. Therefore, in this study, in order to utilize the Integration Map of Underground Goespatial Information in real time on-site, the function of comparing the mutual location of the GPR (Ground Penetration Radar) sensing data and the Integration Map of Underground Goespatial Information, and function of analyze underground facilities, and function of converting surveying data into a shape file through position correction & attribute editing in a 3D space, and the function of submitting the shape file to the Integration Map of Underground Goespatial Information mobile center was defined and developed as a program. In addition, for the on-site application test of the development program, scenarios used at the underground facility real-time survey site and GPR exploration site were derived, and four sites in Seoul were tested to confirm that the use scenario worked properly. Through this, the on-site utilization of the program developed in this study could be confirmed, and it would contribute to the confirmation of the quality of Shape-file and the "update automation" of "Integration Map of Underground Goespatial Information". In addition, it is expected that the development program will be further applied to the Underground Facility Map's Accuracy Improvement Diffusion Project' promoted by the MOLIT (Ministry of Land, Infrastructure, and Transport).

A Study on the Usage and Improvement of the Color Image Scale (색채감성척도의 사용현황 분석 및 개선에 대한 연구)

  • Kim, Miry;Park, Yun-Sun
    • Science of Emotion and Sensibility
    • /
    • v.25 no.3
    • /
    • pp.117-126
    • /
    • 2022
  • This study seeks to identify usage behaviors and improvement factors to increase the academic and practical application of value the of color image scales. For this purpose, the authors discuss the positive and negative perspectives on the evaluation of previous studies on color image scales. Furthermore, a survey was conducted with 25 color experts who have been working in the field for over five years, and in-depth interviews were conducted with five of them. The contents of the survey are usage behaviors, evaluation, and the improvement of Kobayashi and IRI color image scales. In this process, emotional adjectives that need improvement were derived, and the opinions of experts related to improvements were collected. The analysis results are as follows. 1) As a result of the usage behaviors, 92% were aware of both color image scales. Moreover, 44% used both, and 56% used only one. 2) Regarding familiarity and trust, IRI was higher than Kobayashi. 3) A total of 88% of respondents stated that color image scales were necessary. A total of 43.6% of respondents, the largest group of respondents, indicated that color image scales are necessary in the field of practice. 4) Regarding the need for improvement, 88% responded that IRI color image scales need improvement. 5) The highest response to the factors requiring improvement was the reflection of the times, which was 31.9% for Kobayashi and 30.9% for IRI. 6) When improving color image scales, the adjectives that need to be treated as the most important were shown to be modern (15.8%) → natural, romantic, wild (8.8%) → dynamic (7.0%) → classic, casual, chic (5.3%). In conclusion, limitations were identified in the use of color image scales in practice and in the research areas, and there was a demand for correction and supplementation. The results of this study will serve as a foundational study related to color image scales, and it is expected that subsequent research related to color image scales will follow.

Quality of Radiomics Research on Brain Metastasis: A Roadmap to Promote Clinical Translation

  • Chae Jung Park;Yae Won Park;Sung Soo Ahn;Dain Kim;Eui Hyun Kim;Seok-Gu Kang;Jong Hee Chang;Se Hoon Kim;Seung-Koo Lee
    • Korean Journal of Radiology
    • /
    • v.23 no.1
    • /
    • pp.77-88
    • /
    • 2022
  • Objective: Our study aimed to evaluate the quality of radiomics studies on brain metastases based on the radiomics quality score (RQS), Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis (TRIPOD) checklist, and the Image Biomarker Standardization Initiative (IBSI) guidelines. Materials and Methods: PubMed MEDLINE, and EMBASE were searched for articles on radiomics for evaluating brain metastases, published until February 2021. Of the 572 articles, 29 relevant original research articles were included and evaluated according to the RQS, TRIPOD checklist, and IBSI guidelines. Results: External validation was performed in only three studies (10.3%). The median RQS was 3.0 (range, -6 to 12), with a low basic adherence rate of 50.0%. The adherence rate was low in comparison to the "gold standard" (10.3%), stating the potential clinical utility (10.3%), performing the cut-off analysis (3.4%), reporting calibration statistics (6.9%), and providing open science and data (3.4%). None of the studies involved test-retest or phantom studies, prospective studies, or cost-effectiveness analyses. The overall rate of adherence to the TRIPOD checklist was 60.3% and low for reporting title (3.4%), blind assessment of outcome (0%), description of the handling of missing data (0%), and presentation of the full prediction model (0%). The majority of studies lacked pre-processing steps, with bias-field correction, isovoxel resampling, skull stripping, and gray-level discretization performed in only six (20.7%), nine (31.0%), four (3.8%), and four (13.8%) studies, respectively. Conclusion: The overall scientific and reporting quality of radiomics studies on brain metastases published during the study period was insufficient. Radiomics studies should adhere to the RQS, TRIPOD, and IBSI guidelines to facilitate the translation of radiomics into the clinical field.