• Title/Summary/Keyword: Field coil

Search Result 806, Processing Time 0.026 seconds

Pulsed field magnetization of multi-turn short-circuited stabilized double pancake HTS coil

  • Korotkov, V.S.;Krasnoperov, E.P.;Brazhnik, P.A.;Kartamyshev, A.A.;Bishaev, A.M.;Kozinsteva, M.V.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.1
    • /
    • pp.1-5
    • /
    • 2019
  • The pulsed field magnetization of the short-circuited soldered double pancake coil made of stabilized commercial high-Tc superconductor (HTS) tape is experimentally studied. The evolution of the shielding current induced by the pulsed field and the trapped field after the pulsed magnetization was measured at 77 K. It is shown that the trapped field in the coil is close to the value reached in the field cooling process and reduces weakly at 5-fold increasing of pulsed field amplitude. The current relaxation at t~2 ms after the pulse is defined by the current sharing between the tape's copper coating and the $YBa_2Cu_3O_{7-d}$ layer. In the intermediate time scale (1 s < t < 100 s) the flux creep in HTS layer dominates. At t > 100 s the current's relaxation is defined by the resistance of soldered joint between tapes.

High-Order Surface Gradient Coil Design Using Target Field Approach

  • Lee, J.K.;Yang, Y.J.;Jeong, S.T.;Choi, H.J.;Cho, Z.H.;Oh, C.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.19-24
    • /
    • 1996
  • The purpose of this paper is to design high-order (or radial) surface gradient coil (SGC), which can provide multi-dimensional spatial selection. Although the spatial Selection with High-Order gradienT (SHOT) can provide a 2-D selection with only one selective RF pulse, the high-order gradient pro- duced by conventional cylindrical-shape coils has not been clinically useful due to the large selection size caused by the limited radial gradient intensity. However, by using the proposed high-order SGCs located near the imaging region, the size of volume selection can be reduced to a clinically useflll size of 1-2 cm in diameter by applying stronger radial gradient field with much less gradient driving power. So far radial SGCs have been designed by using the field component method and may cause distortion in the selection shapes. In this paper, by using the target field approach for the coil design, selected volumes became almost circular. A 40 cm-by-40 cm $z^2$_surface gradient coil has been designed and implemented by using the target field approach. Phantom and volunteer studies have been performed Experimental results using spatially localized MRI show good agreement to the theoretically predicted behavior.

  • PDF

Effects of RF pulsing and axial magnetic field onionized magnetron sputtering

  • Joo. Junghoon
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.2 no.2
    • /
    • pp.133-138
    • /
    • 1998
  • To enhance the ionization level of I-PVD and reduce the coil voltage two approaches were tried and as a diagnostic, optical emission spectroscopy and impedance analysis of the plasma was done with a range of Ar pressures and RF power along with XRD analysis of deposited Ag films. RF sputtering power was pulsed with various on/off time scales to recover the ICP quenched by sputtered metals. This in average enhances the ionization of the sputtered atoms with 10 ms/10 ms and 100 ms/100ms pulse on/off time duration and gives higher (200) preferred orientation over (111) in deposited Ag films. Secondly, Small axial B field about 8G remarkably reduced RF coil sputtering and showed scaled relationship between RF power and magnetic field strength for optimal process condition. From OES of Ar0 and Ar+, wave-like dispersion structure appeared and reduced the coil voltage about 20% at very weak field strength of 8G. This should be studied further to have nay relation with low mode helicon wave launching.

  • PDF

Development and Construction of low Magnetic Field Control System for Analysis of Magnetic Field Effect in the Deflection Yoke (브라운관의 자기장 영향 분석용 저자기장 제어 장치의 설계 및 제작)

  • Park, Po-Gyu;Kim, Young-Gyun;Shin, Suk-Woo;Choi, Hyung-Ho;Kim, Tae-Ik;Jung, Dong-Keun
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.6
    • /
    • pp.251-256
    • /
    • 2003
  • We have developed the quality analysis system for magnetic field effect of cathode-ray tube that is used a monitor, TV and medical appliance. We designed and constructed the large 3-axis square coil (2 m length) system for the generation of 3-component magnetic field using power supply, magnetometer and computer below 0.2 mT range. The coil constant is 30.31 ${\mu}$T, 29.73 ${\mu}$T and 30.51 ${\mu}$T for the X, Y and Z axis square coil respectively. The magnetic field resolution was 0.01 T. The uniformity of magnetic field was measured within 1 % in the range of 12 cm.

Measurement and Numerical Analysis of AC Loss in the HTS Pancake Coil and the HTS Solenid Coil (고온초전도 팬케이크 코일과 솔레노이드 코일의 교류손실 측정 및 수치해석)

  • Park Myung-Jin;Lee Sang-Soo;Lee Seung-Wook;Cha Guee-Soo;Lee Ji-Kwang
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.12
    • /
    • pp.732-738
    • /
    • 2004
  • In this paper, we constructed 13 turns pancake coil and solenoid coil with HTS tape and measured AC losses of the pancake coil. The critical current of the pancake coil and the solenoid coil were 80A and 109A, respectively. To compare measured AC losses of the two coils, we carried out numerical analysis using 2-D FEM program for manufactured coils. This paper presents current density distribution, flux density distribution and AC losses of the pancake coil and the solenoid. As a result, we obtained that current density distribution was closely related to the orientation of magnetic field and distribution of AC losses were also closely related to the perpendicular component of flux density distribution in coil. The calculated AC losses of the two coils showed good agreement with measured AC losses and AC losses of the pancake coil was about 9 times bigger than that of the solenoid coil under the same turns and length.

Development of Solenoid RF Coil for Animal Imaging in 3T High Magnetic Field MRI (고자장 3T MRI 장비에서 동물영상을 위한 솔레노이드 RF코일 개발)

  • Lee, Hong-Seok;Woo, Dong-Cheol;Min, Kwang-Hong;Kim, Yong-Kwon;Lee, Heung-Kyu;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.20-26
    • /
    • 2007
  • Purpose : The purpose of the present study was to develop and optimize solenoid coil for animal- model in 3 T MRI system and investigate and compare with the birdcage coil concerning the image quality with the various parameters such as SNR and Q-factor. Materials and Methods : Solenoid coil for animal-model was made on the acryl structure (diameter 4 cm, length 10 cm) 3 times-winding cooper tape of width 2 cm, thickness 0.05 cm and length 10 cm with 2 cm interval between winded tapes. Capacitors from 2 pF to 100 pF were used, and the solenoid coil was designed for receiver only coil. Results : SNR of the developed solenoid was 985 in CuSO4 0.7 g/L and 995 in rat experiment. Q-factor was 84-89 in unloaded condition and 203-206 in loaded condition. Conclusion : The resolution of the image obtained from solenoid was relatively higher than that of the conventional birdcage coil. In addition, the homogeneity of RF field by coil simulation was significantly excellent. The present study demonstrated that the solenoid coil could be useful to obtain small animal images with better contrast, resolution, visibility than images from birdcage.

  • PDF

KT-1 토카막의 전자석 코일에 의한 유도가열탈리

  • 정승호;박선기
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.34-34
    • /
    • 1999
  • 토카막(Tokamak)에서는 플라즈마(plasma)로 불순불(impurity)의 유입을 방지하기 위해 고진공을 유지해야 하며 이를 위해 가열탈리(backing), 방전세정(discharge codanning) 등 wall conditioning이 기본적으로 요구된다. KT-1 토카막은 실험실 이전에 따른 해체로 인해 진공용기(vacuum vessel) 가 대기압 하에 수개월 동안 노출되어 있었기 때문에 재조립 후 가열 탈 리가 필수적이나 진공용기의 외부에 saddle loop coil을 비롯해 Rogowski, diamagnetic coil, poloidal field coil 등 많은 magnetic pick up coil 들이 설치되어 있어 열선 등 일반적인 방법으로 가열 탈 리가 어려운 상황이다. 따라서 KT-1 토카막에서는 전자석 코일에 상전원을 부가하였을 때 진공용기에 발생하는 유도가열 (inductive heatin)을 이용해 가열 탈리를 시도하였다. 유도 가열 탈리(inductive backing)는 토로이달 자장 코일(toroidal field coil)과 가열 저장 모일(ohmic heating coil)을 각각 이용하여 코일의 온도가 6$0^{\circ}C$ 이하가 유지되는 코일 전류 범위내에서 수행하였으며 먼저 이 둥 경우에 있어서 진공용기의 온도분포를 비교하엿다. 그리고 가열 탈리 기간 및 그 전, 후의 진공압력과 잔류기체 분압을 측정, 분석하였다. 유도가열에 의한 방법으로 KT-1 토카막에서 얻은 탈리온도는 12$0^{\circ}C$정도로 비교적 낮았으나 탈리 시간을 연장하여 탈리효과를 어느 정도 보상할 수 있으며 일반적인 가열 탈리가 여려운 경우 유도 가열 탈 리가 채택될 수 있는 또 하나의 방법이라 볼 수 있다.

  • PDF

Test of the KSTAR Prototype Toroidal Field Coil (KSTAR 프로토 타입 TF 코일 테스트)

  • Chu, Y.;Lee, S.;Park, K.;Baek, S.;Chung, W.;Lim, B.;Park, H.;Oh, O.K.;Kim, K.
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.307-310
    • /
    • 2003
  • The KSTAR (Korea Superconducting Tokamak Advanced Research) prototype TF (Toroidal Field) coil was tested in the superconducting coil test facility in KBSI (Korea basic Science Institute). The test was divided into several campaigns according to the objectives. The objectives of the first campaign were to cool the coil into operating temperature and to find any defect in the coil such as cold leaks. From the results of the first campaign, which was carried out during Jan. 2003, any defect in the TF prototype coil was not found. At the second campaign, the large-current charging experiment was one of the major issues, and was carried out during Aug. 2003 In this paper, the test preparation, and the test results of the second campaign were presented.

  • PDF

Design and Characteristic Analysis of a Cylindrical Voice Coil Motor (원통형 보이스 코일 모터 설계 및 특성 해석)

  • Lee Hong Kyo;You Yong Min;Kwon Byung Il
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1034-1036
    • /
    • 2004
  • The most basic form of a direct-drive linear motor is the voice coil motor(VCM). The voice coil motor employs a stationary permanent magnet field assembly in conjunction with a moving coil winding assembly to produce a force proportional to the current applied to the coil. Voice coil motor provide motion capable of extremely fine position sensitivity, limited only by the feedback sensor used to close the control loop. This paper presents dual-servo voice coil motor for improvement of driving range and position resolution. The voice coil motor is a cylindrical shape to improve reliability of a nanoindenter.

  • PDF

Improvement of a 4-Channel Spiral-Loop RF Coil Array for TMJ MR Imaging at 7T (7T 악관절 MRI를 위한 4 채널 스파이럴 RF 코일의 성능개선)

  • Kim, Kyoung-Nam;Kim, Young-Bo;Cho, Zang-Hee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.2
    • /
    • pp.103-114
    • /
    • 2012
  • Purpose : In an attempt to further improve the radiofrequency (RF) magnetic ($B_1$) field strength in temporomandibular joint (TMJ) imaging, a 4-channel spiral-loop coil array with RF circuitry was designed and compared with a 4-channel single-loop coil array in terms of $B_1$ field, RF transmit (${B_1}^+$), signal-to-noise ratio (SNR), and applicability to TMJ imaging in 7T MRI. Materials and Methods: The single- and 4-channel spiral-loop coil arrays were constructed based on the electromagnetic (EM) simulation for the investigation of $B_1$ field. To evaluate the computer simulation results, the $B_1$ field and ${B_1}^+$ maps were measured in 7T. Results: In the EM simulation result and MRI study at 7T, the 4-channel spiral-loop coil array found a superior $B_1$ performance and a higher ${B_1}^+$ profile inside the human head as well as a slightly better SNR than the 4-channel single-loop coil array. Conclusion: Although $B_1$ fields are produced under the influence of the dielectric properties of the subject rather than the coil configuration alone at 7T, each RF coil exhibited not only special but also specific characteristics that could make it suited for specific application such as TMJ imaging.