• 제목/요약/키워드: Field coil

검색결과 806건 처리시간 0.024초

와전류 동력계에서 계자전류를 이용한 부하토크의 측정에 관한 연구 (A Study on the Measurement of Load Torque by the Field Coil Current in an Eddy Current Dynamometer)

  • 문병수;이응석;이형석
    • 한국정밀공학회지
    • /
    • 제18권10호
    • /
    • pp.84-92
    • /
    • 2001
  • Commercial eddy current dynamometers control the torque of rotating body, power supply machine, with the field coil current being operated as a braking force. In this paper, we studied the relation between field coil current and torque load of eddy current dynamometer. By the torque measuring analysis of eddy current dynamometer it is linear relation between the brake force measured from a torque meter which is installed at the case of dynamometer and the multiplied shaft rpm by the squares of field coil current (N$\times$I$^2$). To prove the relation, it was experimented and showed that the torque operated by the rotating body can be measured with the shaft rpm and the field coil current of the eddy current dynamometer. This result shows a possibility that eddy current dynamometer can measure the torque of rotating body without a torque measuring device. such as load cell.

  • PDF

A Study on Prototype Hybrid (LTS/HTS) Magnet for NMR Application

  • Choi, Suk-Jin;Hwang, Young-Jin;Ko, Tae-Kuk
    • Journal of Magnetics
    • /
    • 제16권3호
    • /
    • pp.312-317
    • /
    • 2011
  • NMR over 1 GHz (23.5 T) level has difficulties in design and fabrication with only low temperature superconducting (LTS) wire because of its material characteristics such as the decay of critical current under the magnetic field. Because High temperature superconducting (HTS) tape has a good performance under the extremely high magnetic field, it has been developed for high-field magnet over 23.5 T. In this paper, the LTS magnet was made for applying magnetic fields externally and the HTS coil was designed and fabricated. The electromagnetic field analysis has been done with respect to the structure and the operating current of the LTS and HTS coil. Considering to the field homogeneity and the center field, the design parameters which is suitable for the HTS coil were found. The HTS insert coil was impregnated with epoxy resin in order to prevent the movement of winding during energizing the magnet. The hybrid magnet (LTS/HTS) magnet was fabricated and tested based on the design parameters. The experimental result shows that the LTS background magnet and the HTS insert coil can be operated stable beyond 220 A and 210 A. The final value 4.32 T at the center was acquired.

Design of Crisscrossed Double-Layer Birdcage Coil for Improving B1+ Field Homogeneity for Small-Animal Magnetic Resonance Imaging at 300 MHz

  • Seo, Jeung-Hoon;Han, Sang-Doc;Kim, Kyoung-Nam
    • Journal of Magnetics
    • /
    • 제20권3호
    • /
    • pp.308-311
    • /
    • 2015
  • We design a crisscrossed double-layer birdcage (DLBC) coil by modifying the coil geometry of a standard single-layer BC (SLBC) coil to enhance the homogeneity of transmitting magnetic flux density ($B_1{^+}$) along the main magnetic field ($B_0$)-direction for small-animal magnetic resonance imaging (MRI) at 300 MHz. The performance assessment of the crisscrossed DLBC coil is conducted by computational analysis with the finite-difference time domain method (FDTD) and compared with SLBC coil in terms of the $B_1$ and the $B_1{^+}$ distribution. As per the computational calculation studies, the mean value in the two-dimensional $B_1{^+}$ map obtained at the mid-axial slice with the proposed DLBC coil is slightly lower than that obtained with the SLBC coil, but the $B_1{^+}$ value of the DLBC coil in the outermost plane (40 mm away from the central plane) shows improvements of 19.3% and 24.8% over the SLBC coil $B_1{^+}$ value when simulating a spherical phantom and realistic mouse body modeling. These simulation results indicate that, the $B_1{^+}$ homogeneity along the z-direction was improved by using DLBC configuration. Our approach enables $B_1{^+}$ homogeneity improvement along the zdirection, and it can also be applied to ultra-high field (UHF) MRI systems.

A Design of New Surface Gradient Coil and Its Application to MR Computerized Tomography

  • Yi, Jeong-Han;Cho, Zang-Hee
    • 대한의용생체공학회:의공학회지
    • /
    • 제13권3호
    • /
    • pp.217-224
    • /
    • 1992
  • A new three-channel surface gradient coil obtained by using numerical optimization and its application to MR computerized nomography are presented. The new surface gradient coil pro aided linear field gradient region more than twice wider compared with the t'irst surface gradi encl coil, removed torque and field offset, and reduced coupling between the surface gradient coil and combined surface rf coil. We realized the new surface gradient coil set with $30{\times}60{cm^2}$2 size, which generated more tharl 4G/cm with 100 amperes over a $4{\times}4{\times}4{cm^3}$ region with good linearity. The optimal geometries of the three-channel surface gradient coil and volun teer's high-resolution in wiuo spinal cord Images obtained by using the optimized surface gradi ent coil set are presented.

  • PDF

Design of Body RF Coil with Multiple Strips for Open MRI System by Pseudo Electric Dipole Radiation

  • 김경락;류승학;류연철;양형진;오창현
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.76-76
    • /
    • 2002
  • Purpose: The purpose of this study is to optimize the configuration of body RF coil composed of 4 planar subcoils for low field open MRI. Method: Our low field RE coil is composed of 4 subcoils assumed to be located at both the bottom and top sides of permanent magnet. Each subcoils has 3 main strips. The coil system has mirror inversion symmetry. First, the currents on the strips are obtained by inductance calculation and circuit analysis, Second, all the strips are divided into line strip elements across the strips, the self Inductances of line strip elements and the mutual inductances among the line strip elements are calculated, and current distributions of strip are obtained by circuit analysis, where each strip is considered as parallel combination of line strip elements. Finally all the line strip elements are segmented, magnetic field has been calculated by pseudo electric dipole radiation method, where the current elements are regarded as pseudo electric dipole radiation sources. We have performed above procedures for various configurations of RE coil. The field homogeneity is calculated in the 25 cm DSV.

  • PDF

내부 코일형 박막 인덕터의 특성에 미치는 열처리 효과 (Annealing Effect on the Characteristics of Thin Film Inductors with Inner Coil Type)

  • 민복기;김현식;송재성
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권5호
    • /
    • pp.333-338
    • /
    • 1999
  • Thin film inductors of $10 mm \times 10 mm$ with inner coil type of 14 turns were fabricated by sputtering, photo-masking, and etching processes. Their characteristics of impedances and annealing after were investigated. The properties of impedances of the thin film magnetic core inductors with inner coil type were improved by magnetic field annealing due to the removal of residual stress and the improvement magnetic properties of magnetic films. But the characteristics of frequency of the thin film magnetic core inductors were not improved by magnetic field annealing due to properties of the spiral pattern and inner coil type. The thin film magnetic core inductor annealed by uniaxal field annealing method showed an inductance of 1000 nH and resistance of$ 6 \Omega$ of 1 at 2 MHz.

  • PDF

Operational Characteristics of Flux-lock Type SFCL using Series Resonance

  • Lim, Sung-Hun;Han, Byoung-Sung;Choi, Hyo-Sang
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권4호
    • /
    • pp.159-163
    • /
    • 2005
  • We analyzed the fault current limiting characteristics of a flux-lock type $high-T_c$ super­conducting fault current limiter (HTSC-FCL) using series resonance between capacitor for series resonance and magnetic field coil which was installed in coil 3. The capacitor for the series resonance in the flux-lock type HTSC-FCL was inserted in series with the magnetic field coil to apply enough magnetic field into HTSC element, which resulted in higher resistance of HTSC element. However, the impedance of the flux lock type HTSC-FCL has started to decrease since the current of coil 3 exceeded one of coil 2 after a fault accident. The decrease in the impedance of the FCL causes the line current to increase and, if continues, the capacitor for the series resonance to be destructed. To avoid this operation, the flux-lock type HTSC-FCL requires an additional device such as fault current interrupter or control circuit for magnetic field. From the experimental results, we investigated the parameter range where the operation as mentioned above for the designed flux-lock type HTSC-FCL using series resonance occurred.

새로운 자기공명영상촬영용 Quadrature Breast RF 코일 (A New Quadrature Breast RF Coil for MRI)

  • 김선경;양윤정;이덕래;이윤;안창범;오창현
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.291-293
    • /
    • 1997
  • A new quadrature RF coil is designed for Breast MR Imaging. Quadrature RF coils for MRI have been useful to improve the signal-to-noise ratio (SNR) by "$\sqrt{2}$" using two orthogonal RF coils in combination. A modified Breast Quadrature coil is designed. It is a modified type of the high-pass birdcage coil. To reduce the field distortion, by using current feeding, the field pattern is optimized to achieve a quadrature circularly-polarized field pattern. The coil has been implemented for receive-only mode, and tested by phantom imaging. The experimental results show the utility of the proposed RF coil.

  • PDF

FDTD 방법을 이용한 MRI Birdcage RF Coil의 Endcap 효과 분석 (Analysis of Endcap Effect for MRI Birdcage RF Coil by FDTD Method)

  • 정성택;박부식;신윤미;곽준식;조종운;김경남
    • Investigative Magnetic Resonance Imaging
    • /
    • 제7권2호
    • /
    • pp.137-143
    • /
    • 2003
  • 목적 : 자기공명영상(MRI)에서 두부영상촬영을 위하여 가장 많이 사용되는 birdcage RF (Radiofrequency) 코일의 RF B1 필드가 코일 중앙부에서 endring영역으로 갈수록 줄어드는 것을 볼 수 있다. Birdcage RF 코일에서 endcap 쉴드가 코일 중앙부에서 endring영역으로 갈수록 RF B1 필드 균질성에 얼마나 영향을 주는지에 대하여 분석하였다. 대상 및 방법 : Lowpass, highpass, hybrid birdcage RF 코일들에 대해 각각 FDTD (Finite Difference Time Domain) 모의실험으로 RF B1 자속밀도 분포를 비교하였다. 모의 실험결과 RF Bl 필드가 가장 높은 조건인 highpass birdcage RF코일을 선택하여 RF코일 endring 근처에 endcap 쉴드를 적용함으로써 RF B1 균질성에 얼마나 영향이 있는 지 조사하였다. 결과 : FDTD모의실험결과 highpass birdcage RF코일은 코일 내부에서 RF B1 필드가 lowpass나 hybrid 형태의 birdcage RF 코일들 보다 우수하나 코일 중앙부에서 endring 영역까지의 균질성은 떨어졌다. 그러나 highpass birdcage RF 코일에 endcap 쉴드를 적용하면 hybrid birdcage RF 코일의 RF B1 필드와 비슷한 수준이면서 sagittal 방향의 전체적인 RF B1 균질성은 우수하였다. 결론 : 본 논문에서 제안한 방법은 임상에서 MRI자장의 세기가 커질수록 RF코일 내부의 RF B1 균질성이 현저히 떨어지는 문제점이 있는데 이를 개선하는데 적용 할 수 있다고 사료된다.

  • PDF

초음파진동자를 이용한 자계측정방법 연구 (Study on the Magnetic Field Measurement Using the Ultrasonic Transducer)

  • 손은영;류주현;윤광희;정영호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.350-355
    • /
    • 1997
  • A new magnetic field measuring system with induced coil is reported. This system consists of air-cared coil that is forced by the ultrasonic transducer. Induction voltage of coil is proportional to the DC magnetic field and the driving frequency of ultrasonic transducer by the principle of Faraday's law. The experimental measuring system is setup, and the possibility of a new magnetic field sensors is confirmed.

  • PDF