• Title/Summary/Keyword: Field burning

Search Result 116, Processing Time 0.022 seconds

Indoor PM2.5 Concentrations in Different Sizes of Pubs with Non-comprehensive Smoke-free Regulation (비 포괄적인 금연정책을 시행한 호프집의 면적에 따른 실내 PM2.5 농도)

  • Kim, Jeonghoon;Lim, Chaeyun;Lee, Daeyeop;Kim, Heyjin;Guak, Sooyoung;Lee, Na Eun;Kim, Sang Hwan;Ha, Kwon Chul;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.2
    • /
    • pp.126-132
    • /
    • 2015
  • Objectives: The Korean government implemented a smoke-free regulation for pubs with a net indoor area of ${\geq}100m^2$ on January 1, 2014. The purpose of this study was to determine the indoor levels of concentrations of particulate matter smaller than $2.5{\mu}m$ ($PM_{2.5}$) in implemented and non-implemented pubs in Seoul and Changwon. Methods: $PM_{2.5}$ concentrations in fifty-two $100-150m^2$ (implemented) and fifty-seven < $100m^2$ (non-implemented) pubs were measured. A real-time aerosol monitor was used to measure $PM_{2.5}$ concentrations. Field technicians recorded characteristics of the pubs including net indoor area, indoor volume and presence of smoking rooms and counted the number of burning cigarettes, patrons and vents. Results: Differences between indoor and outdoor $PM_{2.5}$ concentrations in $100-150m^2$ and < $100m^2$ pubs were not significantly different in each city. Smoking was observed in 33% of $100-150m^2$ pubs and 51% of < $100m^2$ pubs. Average differences between indoor and outdoor $PM_{2.5}$ concentrations in the $100-150m^2$ and < $100m^2$ pubs were $79.2{\mu}g/m^3$ and $155.6{\mu}g/m^3$, respectively. When smokers were not observed, differences between indoor and outdoor $PM_{2.5}$ concentrations ware $12.4{\mu}g/m^3$ in $100-150m^2$ pubs and $24.5{\mu}g/m^3$ in < $100m^2$ pubs. Conclusion: Although the regulation was implemented only in ${\geq}100m^2$ pubs, a higher difference between indoor and outdoor $PM_{2.5}$ concentrations was observed in implemented and non-implemented pubs with smokers. Strict implementation of the regulation in all pubs is needed for better indoor air quality.

Numerical Study of Flow Characteristics in a Solid Particle Incinerator for Various Design Parameters of Injectors (고체 입자 소각로에서 분사기의 설계 인자에 따른 유동 특성에 관한 수치해석적 연구)

  • Son, Jin Woo;Kim, Su Ho;Sohn, Chae Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.12
    • /
    • pp.1079-1089
    • /
    • 2013
  • The flow characteristics in a solid particle incinerator are investigated numerically for high burning rate of wastes. The studied incinerator employs both a swirl flow used in the furnace of powerplants and a design concept applied to a rocket combustor. As the first step, the non-reactive flow field is analyzed in the incinerator with primary and secondary injectors through which solid fuel and air are injected. The deflection angle of a primary injector, inclination angle of a secondary injector, and gap between the two types of injectors are selected as design parameters. The swirl number is adopted for evaluating the degree of swirl flow and estimated over wide ranges of three parameters. The swirl number increases with deflection angle, but it is affected little by inclination angle. Recirculation zones are formed near the injectors, and their size affects the swirl number. The swirl number decreases with the zonal size of recirculation. From the numerical results, the design points can be found with strong swirl flow.

Enhancement of Ozone and Carbon Monoxide Associated with Upper Cut-off Low during Springtime in East Asia

  • Moon, Yun-Seob;Drummond, James R.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.5
    • /
    • pp.475-489
    • /
    • 2010
  • In order to verify the enhancement of ozone and carbon monoxide (CO) during springtime in East Asia, we investigated weather conditions and data from remote sensors, air quality models, and air quality monitors. These include the geopotential height archived from the final (FNL) meteorological field, the potential vorticity and the wind velocity simulated by the Meteorological Mesoscale Model 5 (MM5), the back trajectory estimated by the Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model, the total column amount of ozone and the aerosol index retrieved from the Total Ozone Mapping Spectrometer (TOMS), the total column density of CO retrieved from the Measurement of Pollution in the Troposphere (MOPITT), and the concentration of ozone and CO simulated by the Model for Ozone and Related Chemical Tracers (MOZART). In particular, the total column density of CO, which mightoriginate from the combustion of fossil fuels and the burning of biomass in China, increased in East Asia during spring 2000. In addition, the enhancement of total column amounts of ozone and CO appeared to be associated with both the upper cut-off low near 500 hPa and the frontogenesis of a surface cyclone during a weak Asian dust event. At the same time, high concentrations of ozone and CO on the Earth's surface were shown at the Seoul air quality monitoring site, located at the surface frontogenesis in Korea. It was clear that the ozone was invaded by the downward stretched vortex anomalies, which included the ozone-rich airflow, during movement and development of the cut-off low, and then there was the catalytic photochemical reaction of ozone precursors on the Earth's surface during the day. In addition, air pollutants such as CO and aerosol were tracked along both the cyclone vortex and the strong westerly as shown at the back trajectory in Seoul and Busan, respectively. Consequently, the maxima of ozone and CO between the two areas showed up differently because of the time lag between those gases, including their catalytic photochemical reactions together with the invasion from the upper troposphere, as well as the path of their transport from China during the weak Asian dust event.

Semi-continuous Measurements of PM2.5 OC and EC at Gosan: Seasonal Variations and Characteristics of High-concentration Episodes (준실시간 연속관측을 통한 제주 고산 PM2.5 OC와 EC의 계절별 사례별 특성)

  • Han, Jihyun;Bahng, Byungjo;Lee, Meehye;Yoon, Soon-Chang;Kim, Sang-Woo;Chang, Limseok;Kang, Kyeong-Sik
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.3
    • /
    • pp.237-250
    • /
    • 2013
  • At Gosan ABC superstation in Jeju Island, we measured organic carbon (OC) and elemental carbon (EC) in $PM_{2.5}$ from October 2009 to June 2010 using a Sunset Laboratory Model-4 Semi-Continuous OC/EC Field Analyzer. It employs TOT (Thermal-Optical-Transmittance) method with NIOSH 5040 protocol and enables to continuously monitor OC and EC concentrations with 1-hour time resolution. The mean values of OC and EC for the entire period of measurements were $2.1{\pm}1.4{\mu}g/m^3$ and $0.7{\pm}0.6{\mu}g/m^3$, respectively. The OC/EC ratio was 3 and EC accounted $25{\pm}2.1%$ of total carbon (TC, TC=OC+EC). Although OC and EC showed similar trend in seasonal variation, the ratio of OC to EC was the highest in early summer when temperature was the highest and the air was affected by biomass burning in the southern part of China. In winter, the high OC and EC concentrations were likely influenced by increased coal combustion from residential heating. The high OC and EC concentrations were observed during events such as haze, dust, and the combination of the two. During the haze events, OC and EC were enhanced with increase in $PM_{10}$, $PM_{2.5}$, $SO_2$, and $NO_2$ with broad maxima. When dust occurred, both OC and EC started decreasing after reaching their maxima a couple of hours before $PM_{10}$ maximum. The peak separation of carbonaceous species and aerosol masses with time was more noticeable when haze event was followed by dust plume. These results confirm that OC and EC are key components of haze occurring in the study region.

Efficacy and phytotoxicity of a petroleum spray oil for control of citrus red mite in Jeju island (제주지역에서 귤응애에 대한 Petroleum Spray Oil의 방제효과 및 식물독성)

  • Kim, Dong-Whan;Kim, Kwang-Sik;Hyun, Jae-Uk;Kang, Si-Yong;Song, Jeong-Hueb;Riu, Key-Zung
    • The Korean Journal of Pesticide Science
    • /
    • v.4 no.4
    • /
    • pp.87-92
    • /
    • 2000
  • Recently, a new developed petroleiun spray oil(PSO; D-C Tron $Plus^{(R)}$) has been used to control key pests in integrated pest management (IPM) system of citrus orchards in Australia. The efficacy and phytotoxicity of the PSO against the citrus red mite (Panonychus citri) were compared with conventional pesticides (e.g.Tebufenpyrad, Bifenazate and Sun spray oil) in field condition in Jeju. And under PSO mixing spray with some fungicides, the occurrence of phytotoxic symptoms on citrus leaf was investigated. All concentrations of PSO spraying (0.25%, 0.33%, 0.5% and 1.0%) were significantly suppressed the citrus red mite to similar levels of other conventional pesticides. And the spraying of PSO levels ${\geq}0.5%$ was induced not only occurrence of some oil-sucked symptoms on leaf, but also increase of the dropping leaf and fruit rates. As results from mixing PSO spraying test with other fungicides, little burning on new flush shoot was founded only in PSO 1% plus Fluazinam treatment. From the results of this study, with the consideration of pesticidal efficacy and phytotoxicity, 0.25% and 0.33% PSO spraying level will be recommended for the control of citrus red mite during summer season in Jeju.

  • PDF

Core Technologies Derivation of Fusion DEMO Reactor Applying TRL and AHP (TRL과 AHP를 적용한 핵융합 실증로 핵심기술 도출)

  • CHANG, Hansoo;KIM, Youbean;CHOI, Wonjae;THO, Hyunsoo
    • Journal of Technology Innovation
    • /
    • v.22 no.4
    • /
    • pp.145-164
    • /
    • 2014
  • Nuclear fusion is one of the most promising options for generating large amounts of carbon-free energy in the future. Major countries such as China, EU, and Japan have established a national plan for DEMO construction and they are implementing it. Korea has started a nuclear fusion research and development by the KSTAR project started in 1995. There are matured needs for a full-scale research and development initiatives to ensure competition with the major countries for DEMO as well as achieve the final goal to commercialize fusion energy. In this paper, we apply the TRL and AHP methods in order to identify the key technologies to conduct DEMO R&D. We propose the priorities of future R&D on DEMO by deriving a core technology in the field. At first, we review the scientific theory of fusion and trend of progress of DEMO activities in major countries. For previous studies, we review TRL and AHP methods to examine the technology classification system of DEMO and identify key technologies. We apply TRL method to identify readiness level of DEMO technologies and AHP to compensate shortcoming of TRL. The key technologies of DEMO to be secured from a synthesis result of the TRL and AHP are burning plasma, plasma facing material, structural material, high frequency heating, neutral particle beam, safety, plasma diagnostic, and simulation technologies.

The Study on the Countermeasure Plans about Leakage, Explosion and Fire Accidents of Atmospheric Storage Tank (옥외저장탱크 누출, 폭발 및 화재사고 대응방안에 관한 고찰)

  • Lee, Gab-Kyoo
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.48-56
    • /
    • 2016
  • A crude oil leakage from a large atmospheric storage tank occurred on 4 April 2014 at 14:50 in Ulsan City, while storing the crude oil in the tank. Emergency Rescue Control Group was deployed in the scene. The company, Fire Service Headquarters and associated agencies got together in Command Post (CP) for discussing an effective corresponding strategy. Many solution plans were drafted in the debate such as power down, stopping the facilities, checking the density of inflammable gas, suppressing oil evaporation, moving the leaked crude oil to a nearby tank and a processing plant and avoiding marine pollution. All the solutions were carried out in cooperation with several agencies and partners. The oil leakage accident was successfully settled up within the process of responding, The Fire Service Headquarters and the company thought that the most important thing was the suppression of oil evaporation and the elimination of ignition source. With Fire Service Headquarters and several agencies' every effort, an explosion and a fire didn't occurred in the scene. This study suggest the improvement of the operating system in Emergency Rescue Control Group in case of petroleum leakage, explosion and fire accidents of atmospheric storage tank, different from a ordinary disaster. Assuming that petroleum leakage in atmospheric storage tank develop the explosion and fire accidents, the spreading speed of the flame and the burning time was experimented and compared with each other. Furthermore, this study concentrates on the effective field response plan prepared for the afterward explosion and fire accidents from petroleum leak in a storage tank, with the database experimented and analyzed in accordance with the angle of radiation in the foam nozzle and the pressure of pumping in a fire engine.

Fabrication of Electrospun PAN/FA Nanocomposites and Their Adsorption Effects for Reducing Volatile Organic Compounds (전기방사에 의한 PAN/FA 나노 복합재의 제조 및 휘발성 유기 화합물에 대한 흡착효과)

  • Ge, Jun Cong;Wang, Zi Jian;Yoon, Sam Ki;Choi, Nag Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.702-708
    • /
    • 2018
  • Volatile organic compounds (VOCs), as a significant air pollutant, is generated mainly from the burning of fossil fuels, building materials using painting, etc. The inhalation of a certain amount of VOCs can be deleterious to human health, e.g., headaches, nausea and vomiting. In addition, it can also cause memory loss and even increase the rate of leukemia. Therefore, as one of the methods for reducing VOCs in air, polyacrylonitrile/fly ash (PAN/FA) composite nanofibrous membranes were fabricated by electrospinning. To observe their VOCs adsorption capacity, the morphological structure of PAN/FA nanofibrous mats was investigated by field emission scanning electron microscopy (FE-SEM), and the VOCs (chloroform, benzene, toluene, and xylene) adsorption capacity of PAN/FA membranes were tested by gas chromatography/mass spectrometry (GC/MS). The results indicated that the PAN nanofiber containing 40 wt. % FA powder had the smallest fiber diameter of 283 nm; they also showed the highest VOCs adsorption capacity compared to other composite membranes.

A Study on Characterization of Expansion Agent in Mortar with Light Burned Dolomite By-Product (경소백운석(輕燒白雲石) 부산물(副産物)을 활용(活用)한 바닥 몰탈용 팽창재(膨脹材)의 특성검토(特性檢討))

  • Lee, Keon-Ho;Min, Sung-Eoi;Lee, Hyoung-Woo;Cho, Jin-Sang;Cho, Kye-Hong;Han, Choon
    • Resources Recycling
    • /
    • v.21 no.6
    • /
    • pp.12-22
    • /
    • 2012
  • This study investigated a utilization technology of light burned dolomite. light burned dolomite ($CaMg(CO_3)_2$) generated in furnace (steel manufacturer) is an alternative to quick lime. Using light burned dolomite has an effect on reducing the consumption of fluorite slag MgO concentration in supersaturated solution by prolonging the life of softening effect. Armophous MgO, not containing periclase is formed by firing dolomite under $800^{\circ}C$. It has larger surface area and higher reactivity than periclase, and also shows better expansion effect than quicklime. Due to those effects, therefore, armophous MgO produced from light burned dolomite is used as an alternative expansion agent in mortar. In the experiment, characteristics of light burned dolomite were compared to those of existing expansion agents such as anhydrite and quicklime. Then, each expansion and shrinkage rates were measured over a period of about 3 months in both of 1m Jis mold at labscale and apartment mortar flooring at field scale. In the result, it was observed that light burned dolomite in mortar flooring more compensates for the expansion and shrinkage rates than the existing expansion agents, showing low expansion rate of below 0.05% and also decreases the crack.

Experimental Study on Flow Direction of Fire Smoke in DC Electric Fields (DC 전기장 내에서 발생하는 화재연기 진행 방향에 대한 실험적 연구)

  • Park, Juwon;Kim, Youngmin;Seong, Seung Hun;Park, Sanghwan;Kim, Ji Hwan;Chung, Yongho;Yoon, Sung Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.5
    • /
    • pp.675-682
    • /
    • 2021
  • Fire accidents on land and at sea can cause serious casualties; specifically, owing to the nature of marine plants and ships, the mortality rate at sea from suffocation in confined spaces is significantly higher than that on land. To prevent such cases of asphyxiation, it is essential to install ventilation fans that can outwardly direct these toxic gases from fires; however, considering the scale of marine fires, the installation of large ventilation fans is not easy owing to the nature of marine structures. Therefore, in this study, we developed a new concept for fire safety technology to control toxic gases generated by fires from applied direct current (DC) electric fields. In the event of a fire, most flames contain large numbers of positive and negative charges from chemi-ionization, which generates an "ionic wind" by Lorentz forces through the applied electric fields. Using these ionic winds, an experimental study was performed to artificially control the fire smoke caused by burning paper and styrofoam, which are commonly used as insulation materials in general buildings and ships. The experiments showed that a fire smoke could be artificially controlled by applying a DC voltage in excess of ±5 kV and that relatively effective control was possible by applying a negative voltage rather than a positive voltage.