• Title/Summary/Keyword: Field Exposure

Search Result 1,035, Processing Time 0.021 seconds

An Experimental Study on the Effect of Electric Field the Ornithine Decarboxylase Activity Change of Myeloid Cells According to Ionizing Radiation Exposure (이온화방사선 피폭에 의한 골수세포의 Ornithine Decarboxylase 활성도의 변화에 대한 전계장의 영향에 관한 실험적 연구)

  • 정문호
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.1
    • /
    • pp.78-85
    • /
    • 1995
  • Ornithine decarboxylase(ODC) is an indicate enzyme in carcinogenesis. We divided Sprague Dawley rats into six groups: control, electric field exposure, X-ray only irradiation, X-ray irradiation with electric field exposure group, Sr-90 injected group and Sr-90 and electric field complex exposure group. The ODC activity was measured in rat's bone marrow cell every week. The results were summarized as follows: The ODC activitied was increased in X-ray irradiated, Sr-90 injected and Sr-90 and electric field complex exposed group as compared with that of control(p<0.05). The ODC activity was increased comparing that of control neither in X-ray and electric field complex exposed group nor electric field only exposed group. This result suggests that the electric field doesn't have myeloid carcinogenicity and myeloid cancer incidence caused by ionized radiation is suppressed by electric field exposure.

  • PDF

Development of the Estimating Equation for Children's High-Exposure to Habitat's Magnetic Field using Particle Swarm Optimization (Particle Swarm Optimization을 이용한 소아고노출 생활자계 추정식 개발)

  • Hwang, Gi-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.5
    • /
    • pp.1085-1092
    • /
    • 2010
  • This paper describes the development of estimating equation for under 16 aged children's exposure to habitat's magnetic field for 24 hours by using particle swarm optimization(PSO) algorithm, which was carried out by using the measured database collected from the exposure survey to Korean habitat's magnetic field as to under 16 aged Korean students such as preschooler, children in elementary school, and children in middle school. Sex, age, residence type, size of habitation site, distance from power line, and power transmission voltage are used as the input data of estimating 24 hour's personal exposure to magnetic field. And distribution of 24 hour's personal exposure to magnetic field, exposure characteristic to magnetic field, and exposure characteristic to magnetic field according to special conditions, are analyzed for under 16 aged children.

Survey on the Personal Magnetic Field Exposure of Sample Koreans from Living Environment (생활환경에서의 표본 한국인의 개인자계 노출량 조사)

  • 주문노;양광호;명성호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.2
    • /
    • pp.97-102
    • /
    • 2004
  • The objective of this survey is to characterize personal magnetic field exposure of the general population in Korea. Participants for the survey on magnetic field exposure were selected randomly in some occupations. Those wore the magnetic field meter for about 25∼28 hours and the measured data were stored in the meter. In this first step survey, the number of participant is 244 and for the second step, about 400 participants will be surveyed in the near future. The statistics of the 24-hour exposure data are the major concern of this survey. However the survey provided the opportunity to analyze exposures corresponding to different types of activities. It was analyzed by separating periods of time corresponding to the following activities: entire 24-hour period, in bed, at work and by occupation. Therefore the database will be able to be established to analyze the status of personal magnetic field exposure and safety.

A Study on Effect of Electric Field for Carcinogenesis of Strontium 90 (Strontium 90의 골수 발암성에 대한 전계장의 영향에 관한 실험적 연구)

  • 정문호;두옥주
    • Journal of Environmental Health Sciences
    • /
    • v.20 no.3
    • /
    • pp.61-77
    • /
    • 1994
  • Sprague Dawley rats were exposed to electric fields (6,000 V, 10 kV/m, 30 min/day, 6 days per week) and injected strontium 90 (681 kbq/rat, one time) through abdominal cavity (strontium 90 and electric field complexed exposure group). In parallel, series with the electric field exposure only, strontium 90 injection only and control groups were run. Every group was consisted of 110 rats (55 male and 55 female). This animal experiment was performed from May to December in 1993. This results were conducted to investigate the effect of electric field for 11 weeks. The results are summarized as follows: 1. Ornithine decarboxylase (ODC) activity in rat's bone marrow cells: The ODC values was significantly increased in Sr$^{90}$ injection group and Sr$^{90}$ and electric field complexed exposure group as compared with that of control group (p<0.05). The ODC value was significantly decreased in electric field and Sr$^{90}$ complexed exposure group in comparison with Sr$^{90}$ injection group (p<0.05). The ODC values of electric field only exposure group was not different to that of control group (p>0.05). 2. The amount of Sr$^{90}$ accumulation in the femur, kidney and spleen:The accumulation amount of Sr$^{90}$ in the femur of Sr$^{90}$ injection group represented higher value than that of electric field and Sr$^{90}$ complexed exposure group (p<0.05). In the kidney and spleen, the difference between electric field and Sr$^{90}$ complexed exposure group and Sr$^{90}$ injection group wasn't observed. 3. The counts of white cells in blood of Sr9?injection group was decreased as compared with the value from control group and electric field and Sr$^{90}$ complexed exposure group (p<0.05). The rat's body weight, red blood cell counts and the weight data of liver, kidney and spleen did not show differences among four groups.

  • PDF

Dual effect of Low- frequency Electromagnetic Field on Muscle Histopathology of Caspian Sea Cyprinus carpio

  • Samiee, Farzaneh;Samiee, Keivandokht
    • Journal of fish pathology
    • /
    • v.30 no.1
    • /
    • pp.51-61
    • /
    • 2017
  • The effect of electromagnetic field on aquatic organisms has received little attention. In the current study, the effect of 50Hz electromagnetic field on muscle histopathology of Caspian Sea Cyprinus carpio, a species of economic importance, was investigated. A total of 120 healthy fish were used in this study. They were classified randomly in one of two groups as follows: Control or unexposed EMF group and experimental group with 5 different magnetic field intensities (0.1, 1, 3, 5 and 7mT) at 2 different exposure times including 30 and 60 minutes. Fish in the experimental group were exposed only once. Two weeks after exposure, dorsal muscles sectioned transversely, stained and were examined using a light microscope. Histopathologic assessments showed significant difference between control and EMF exposed groups at both 30 min. (p<0.01) and 60 min. (p<0.001) exposure times. We report for the first time that electromagnetic field in interaction with muscular tissue of Cyprinus carpio exhibits a dual effect which depends on the field intensity, and exposure time. At short exposure time (30 min.), EMF stimulates muscle growth process. At longer exposure time (60 min.), EMF can damage muscle tissue and result in muscle necrosis. More research is required to elucidate precise mechanisms involved in muscle hypertrophy and pathologic changes.

A Preliminary Survey on Personal Magnetic Field Exposure of Sample Koreans

  • Yang, Kwang-Ho;Ju, Mun-No;Myung, Sung-Ho
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.12C no.4
    • /
    • pp.195-200
    • /
    • 2002
  • The objective of this survey is to characterize personal magnetic field exposure of the general population in Korea. The participants of the survey on magnetic field exposure were selected randomly in some occupations. The participant wore the magnetic field meter for about 25∼28 hours and the data were stored in the meter. Because this is a preliminary for the main survey, it was done with 36 participants only. For the main survey, about 400 subjects by occupation will be done. The statistics of the 24-hour exposure data are the major concern of this survey However the survey provided the opportunity to analyze exposures corresponding to different types of activities. It was analyzed by separating periods of time corresponding to the following activities: entire 24-hour period, in bed, at work and by occupation.

Effect of electromagnetic field exposure on the reproductive system

  • Gye, Myung-Chan;Park, Chan-Jin
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.39 no.1
    • /
    • pp.1-9
    • /
    • 2012
  • The safety of human exposure to an ever-increasing number and diversity of electromagnetic field (EMF) sources both at work and at home has become a public health issue. To date, many in vivo and in vitro studies have revealed that EMF exposure can alter cellular homeostasis, endocrine function, reproductive function, and fetal development in animal systems. Reproductive parameters reported to be altered by EMF exposure include male germ cell death, the estrous cycle, reproductive endocrine hormones, reproductive organ weights, sperm motility, early embryonic development, and pregnancy success. At the cellular level, an increase in free radicals and $[Ca^{2+}]i$ may mediate the effect of EMFs and lead to cell growth inhibition, protein misfolding, and DNA breaks. The effect of EMF exposure on reproductive function differs according to frequency and wave, strength (energy), and duration of exposure. In the present review, the effects of EMFs on reproductive function are summarized according to the types of EMF, wave type, strength, and duration of exposure at cellular and organism levels.

Sptimum Design of a Uniform Magnetic Field Exposure System for a Small-Sized Animal Study (자계 균일 공간 확보를 위한 소동물 실험용 5G급 자계 발생장치의 최적 설계)

  • 김상범;추장희;이동일;명성호
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.7
    • /
    • pp.1194-1203
    • /
    • 2000
  • A magnetic field exposure system that generates 60 Hz magnetic fields from 1 mG to 5 G was designed and constructed for small-sized animal study. In order to investigate as many animals as possible at one series of test, uniform magnetic fields are required at wide living area of the animals. In this article, a cubic shaped field exposure system with three animal living floors was designed, which offers about 50 seating capacity. For calculation of magnetic fields inside the cage, a three-dimensional calculation program was developed. Using this, optimum electric current ratio of inner coil to outer coil and position of each coil were determined. Meanwhile, inductance of the exposure system was calculated for the design of power supply. The field measurement results of the manufactured exposure system showed that the difference between maximum and minimum magnetic field at the testing floors was less than 3%, which strongly demonstrated the field exposure system was good for small sized animal study.

  • PDF

Development of a New Personal Magnetic Field Exposure Estimation Method for Use in Epidemiological EMF Surveys among Children under 17 Years of Age

  • Yang, Kwang-Ho;Ju, Mun-No;Myung, Sung-Ho;Shin, Koo-Yong;Hwang, Gi-Hyun;Park, June-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.3
    • /
    • pp.376-383
    • /
    • 2012
  • A number of scientific researches are currently being conducted on the potential health hazards of power frequency electric and magnetic field (EMF). There exists a non-objective and psychological belief that they are harmful, although no scientific and objective proof of such exists. This possible health risk from ELF magnetic field (MF) exposure, especially for children under 17 years of age, is currently one of Korea's most highly contested social issues. Therefore, to assess the magnetic field exposure levels of those children in their general living environments, the personal MF exposure levels of 436 subjects were measured for about 6 years using government funding. Using the measured database, estimation formulas were developed to predict personal MF exposure levels. These formulas can serve as valuable tools in estimating 24-hour personal MF exposure levels without directly measuring the exposure. Three types of estimation formulas were developed by applying evolutionary computation methods such as genetic algorithm (GA) and genetic programming (GP). After tuning the database, the final three formulas with the smallest estimation error were selected, where the target estimation error was approximately 0.03 ${\mu}T$. The seven parameters of each of these three formulas are gender (G), age (A), house type (H), house size (HS), distance between the subject's residence and a power line (RD), power line voltage class (KV), and the usage conditions of electric appliances (RULE).

Effect of Field Size on the Clinical Exposure Index for Lumbar Spine X-ray Examination (노출지수를 이용한 요추 X선 촬영의 조사야 유효성 평가)

  • Park, Hyemin;Yoon, Yongsu;Kim, Jungsu;Jeong, Hoiwoun
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.183-187
    • /
    • 2021
  • The field size of the lumbar spine X-ray examination, which belongs to the most frequent examination in general radiography, is 5 times wider than the width of the lumbar spine. Exposure index (EI) as per International Electrotechnical Commission has a proportional relationship with the dose incident on the image receptor for clinical protocols in addition to RQA5, which is a calibration beam quality. In this study, the effectiveness of the set field size was evaluated through the change of EI according to the size of field during lumbar spine X-ray examinations. Lumbar anterior-posterior and lateral examinations was performed using a whole-body phantom, and the national average exposure conditions of Korea investigated in 2017 were introduced for the X-ray exposure. As a result of comparing the EI displayed on the console of digital radiography system for the three field size in ① 18 × 36 cm2 ② 25 × 36 cm2 ③ 36 × 36 cm2, the EI values showed a tendency to increase as the field size increased. Since the patient dose, such as organ dose around the lumbar spine, increases as the field size becomes larger, thus, if the EI obtained from the field size at a level that does not interfere with diagnosis is set as a reference, the effectiveness of the field size can be evaluated through the EI displayed on the console when the lumbar spine X-ray examination is conducted.