• Title/Summary/Keyword: Field Case

Search Result 7,275, Processing Time 0.029 seconds

Case study on the Collapse types get out of the General Theory (일반적 이론을 벗어난 절토사면 붕괴 유형)

  • Koo, Ho-Bon;Kim, Seung-Hyun;Rhee, Jong-Hyun;Lee, Jung-Yup
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.229-240
    • /
    • 2006
  • Most of rock slopes contain a lot of discontinuities which have a specific direction and various characteristics. In general, the collapses of the rock slopes occur when the sliding dip of the discontinuity is higher than the internal friction angle and also smaller than the free-air plane of the slope. If a general slope theory is only considered in the case of field exploration of the slopes, there is a possibility that dangerous slopes might be estimated as stable slopes. We mention problems that can easily fail to notice something in field exploration and propose the alternatives to solve the problems through the case studies.

  • PDF

The Influence of Parallel Magnetic Field on Magnetization Loss in a Bi-2223 Tape (수평자계가 Bi-2223테이프의 자화손실에 미치는 영향)

  • 한형주;류경우;최병주
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.185-188
    • /
    • 2001
  • Magnetization loss of a Bi-2223 tape in magnetic fields parallel to the tape surface was measured by a magnetization method. The results indicate that the magnetization loss is hysteretic because the measured loss agrees well with calculated one from a critical state model. In the full field penetration case the magnetization loss increases with the frequency but in the partial field penetration case the influence of the frequency is opposite.

  • PDF

Calculation and Mitigation of Magnetic Field Produced by Straight Line-Conductor with Finite Length (유한장 직선도체에 의한 자계의 계산 및 감소대책)

  • Kang, Dae-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.57-67
    • /
    • 2011
  • Purpose of this study is to find the mitigation method of magnetic field by finite length multi-conductors such as indoor distribution lines and to be applicable to design of the distribution lines. For this purpose, exact formula about the components $B_x$, $B_y$, $B_z$ of magnetic field need in case of straight line-conductor with finite length forward any direction. In this study simple formula of the components were deduced and by using these formula magnetic fields for various models of line-configurations were calculated. And also a calculation method of induced currents in conductive shield was presented and using this method, programing of calculation is relatively easy and calculation time is short. The magnetic field after cancellation by these induced currents was calculated. All of calculations were performed by Matlab 7.0 programs. Through the calculation results it could be obtained followings for the mitigation of magnetic fields. The separation between conductors ought to be smaller than smaller as possible. In case of 3-phase, delta configuration is more effective than flat configuration. In case of 3-phase, unbalanced currents ought to be reduced as possible.. In case of more than two circuits of 3-phase, adequate locations of each phase-conductor such as rotating configuration of 3-phase conductors are more effective. The magnetic shielding effect of the conductive shielding sheet is very high.

The effect of magnet fields on the corona discharge (코로나 방전에 대한 자계의 영향)

  • 박재윤;정장근;김익균
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.3
    • /
    • pp.51-56
    • /
    • 2001
  • In this paper, the effect of magnetic field on corona discharge phenomena was experimentally investigated in the needle-plate electrode geometry. Needle-plate geometry discharge system with magnetic field at a right angle to the electric field was made. The corona discharge characteristics with magnetic field were investigated and compared with the corona characteristics without magnetic field in atmospheric pressure. As a result, in case of positive DC corona discharge with magnetic field, corona discharge zone was significantly wider, corona current was lower, and breakdown voltage was higher than those without magnetic field. However, in case of negative DC corona discharge with magnetic field, corona current was slightly higher and breakdown voltage was lower than those without magnetic field. It is thought that this result is due to cyclotron motion of charged particles such as electron and ion by magnetic field.

  • PDF

Dynamic analyses and field observations on piles in Kolkata city

  • Chatterjee, Kaustav;Choudhury, Deepankar;Rao, Vansittee Dilli;Mukherjee, S.P.
    • Geomechanics and Engineering
    • /
    • v.8 no.3
    • /
    • pp.415-440
    • /
    • 2015
  • In the present case study, High Strain Dynamic Testing of piles is conducted at 3 different locations of Kolkata city of India. The raw field data acquired is analyzed using Pile Driving Analyzer (PDA) and CAPWAP (Case Pile Wave Analysis Programme) computer software and load settlement curves along with variation of force and velocity with time is obtained. A finite difference based numerical software FLAC3D has been used for simulating the field conditions by simulating similar soil-pile models for each case. The net pile displacement and ultimate pile capacity determined from the field tests and estimated by using numerical analyses are compared. It is seen that the ultimate capacity of the pile computed using FLAC3D differs from the field test results by around 9%, thereby indicating the efficiency of FLAC3D as reliable numerical software for analyzing pile foundations subjected to impact loading. Moreover, various parameters like top layers of cohesive soil varying from soft to stiff consistency, pile length, pile diameter, pile impedance and critical height of fall of the hammer have been found to influence both pile displacement and net pile capacity substantially. It may, therefore, be suggested to include the test in relevant IS code of practice.

Case Study of Right-side Homonymous Hemianopia in a Stroke Patient Treated by Traditional Korean Medical Treatment (우측 반맹을 호소하는 환자 치험 1례)

  • Ey, Yoo-lee;Son, Jeong-hwa;Park, Min-jeong;Cho, Ki-ho;Moon, Sang-kwan;Jung, Woo-sang
    • The Journal of Internal Korean Medicine
    • /
    • v.37 no.2
    • /
    • pp.237-242
    • /
    • 2016
  • Objective: This study presents a case of a 56-year-old Korean male with right-side hemianopia due to stroke. Homonymous hemianopia represents a visual field defect related to loss of vision in all or part of the left or right visual field in both eyes; treatment options for this condition are limited.Method: The patient was treated with acupuncture, moxibustion, herbal medicine (Yangguksanhwa-tang), and electroacupuncture around the eyes. We executed a confrontation visual field exam (the Donders test) to evaluate any visual field defectsResults: The visual field area showed improvement after the management of traditional Korean medical treatments.Conclusion: Based on this case, traditional Korean medical treatments may be effective in treating hemianopia due to stroke.

The Suitability of Toughened Glass Stem Insulator for Korea High Speed Catenary System (고속전차선로 유리애자 현장 적합성 기반 구축 연구)

  • Lee, Gi-Chun;Jeon, Yong-Joo;Lee, Jong-Woo
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.2
    • /
    • pp.243-248
    • /
    • 2009
  • The operation of KTX in Korea has launched since 2004, which brought about a great change in railroad industry. We have acquired lots of great know-hows, especially in railroad construction and operation field. Therefore, we have been building up numerous operation skills until now. However, it was necessary to investigate some of the equipment based on our own environment because the high speed train system were totally imported. In case of Toughened Glass Stem Insulator, it was totally new type in domestic. This paper introduces estimation method and result in three different field aspect, such as an electrical field, a physical field, and environmental circumstances. First, in case of an electrical field, amplitude and a number of time for switching surge voltage data were collected. Second, in case of a physical field, amplitude and trend of vibration in to the insulator were examined. Finally, in case of environmental circumstances, flying possibility of gravel and ice clod were investigated. Also shrink and expend characteristic according to temperature were reviewed. Through this basic data, suitability for Toughened Glass Stem Insulator using in domestic high speed railway have been accumulated and estimated.

A study for Decision Method of Human Body Safety according to Power Load Fluctuation of the Chechon Area (제천지역 전력부하변동에 따른 인체 전 판단 방법에 대한 연구)

  • 김상철;김두현
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.4
    • /
    • pp.69-77
    • /
    • 2000
  • This paper presents a study for decision method of human body safety according to power load fluctuation of the Chechon area. To cope with substantial electromagnetics analysis, the safety assessments were analyzed the double 154 [kV] T/L, 345 [kV] T/L, Chechon-Ichon, Chechon-Youngju, respectively. As the results of case study, in case of 345 [kV] T/L, the electric field value was 11.4927 [kV/m], magnetic field value was 0.4622 [G] at the point about 7 [m] away from the line in severest case. The results showed that the membership of a proposition fuzzy '11.4937 [kV/m] is hazardous' is 0.7063 for the severest case in case of 345 [kV] T/L. As the analytic results using the fuzzy qualifier term, the membership in case of very false is 0.0862 and fairly false is 0.5419, respectively.

  • PDF

Case study on hydroelastic vibration of plate for various bounded fluid field (유체장 변화에 따른 사각형 탱크의 진동에 관한 연구)

  • Kim, K.S.;Choi, S.H.;Jo, H.D.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.855-860
    • /
    • 2006
  • In this paper, a numerical case study is carried out on the hydroelastic vibration of rectangular plate with various fluid field. It is assumed that the tank wall is clamped along the plate edges. The VMM(Virtual Mass Method) of Nastran is used for the simulation of fluid domain and calculating natural frequency of fluid-coupled structure. In this paper, natural frequencies are calculated and compared for rectangular plates with various fluid field such as infinite fluid and finite fluid, length change of finite fluid field and various fluid contacting conditions.

  • PDF

The Derivation of Generalized Quasi-Three Dimensional Displacement Field Equations for the Analysis of Composite Laminates (복합재료 적층판의 해석을 위한 일반화 준 3차원 변위식의 도출)

  • 김택현
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.4
    • /
    • pp.21-27
    • /
    • 1998
  • In the case of existing in free-edge delaminations of composite laminates which are symmetry with respect to mid-plane in laminates also, in the case of asymmetry and anti-symmetry, the generalized quasi-three dimensional displacement field equations developed from quasi-three dimensional displacement field equations can be applied to solve above cases. We introduce three paramenters in this paper, which have not been used in quasi-three dimensional displacement field equations until now. To the laminate subjected to the axial extension strain $\varepsilon$0(C1) in $\chi$-direction, the bending deformation $\chi$$\chi$(C$_2$) around у-direction, the bending deformation w$\chi$(C$_4$) around z-direction and the twisting deformation $\chi$$\chi$y(C$_3$) around $\chi$-direction .The generalized quasi-three dimensional displacement field equations are able to be analyzed efectively.