• Title/Summary/Keyword: Fibrous materials

Search Result 318, Processing Time 0.023 seconds

Characterization of Silk Fibroin/S-carboxymethyl Kerateine Surfaces: Evaluation of Biocompatibility by Contact Angle Measurements

  • Lee, Kuen-Yong
    • Fibers and Polymers
    • /
    • v.2 no.2
    • /
    • pp.71-74
    • /
    • 2001
  • Surface characterization of materials has been considered critical in the development of biomaterials, as many unfavorable responses from the body occur at the interface between a material and the body component. The contact angle measurement is one means to characterize the surface properties and to correlate them to the biocompatibility of materials. In this paper, surface characteristics of silk fibroin/S-carboxymethyl kerateine, representative fibrous proteins, were investigated by contact angle measurements of ESCA. The biocompatibility of the blends was evaluated based on minimal interfacial free energy concept, and compared with other potential biomaterials. It was also hypothesized that the enhanced surface polarity of the blends was generated from the conformational transition of proteins. This approach to evaluate the biocompatibility of materials based on surface characteristics may find wide utility in many biomedical applications.

  • PDF

The Solidification Characteristics of Styronaphthalene Pattern Materials (스티로나프타린 모형재료의 응고특성)

  • Park, Heung-Il
    • Journal of Korea Foundry Society
    • /
    • v.23 no.1
    • /
    • pp.47-51
    • /
    • 2003
  • This experimental study was carried out to investigate the solidification characteristics of polystyrene added styronaphthalene pattern materials using various castability test methods. The styronaphthalene showed an excellent filling capacity and shaping behavior having about 0.2 mm meniscus radius. The shell thickness of styronaphthalene showing smooth wall at the solid/liquid interface increased with the increasing of polystyrene addition. The solidification microstructure of styronaphthalene showed a typical thin ribbon reinforced composite structure, which has fibrous amorphous skeleton of polystyrene and crystalline naphthalene. From the results of this study, it was found that the polystyrene added styronaphthalene showed a precision shaping behavior as disposable pattern material under the atmospheric condition.

FABRICATION OF POROUS SILICA FIBERS BY ELECTROSPINNING FOR SOUND ABSORBING MATERIALS

  • Y.-S. CHO;H. JIN. LEE
    • Archives of Metallurgy and Materials
    • /
    • v.63 no.3
    • /
    • pp.1497-1502
    • /
    • 2018
  • Macroporous silica fibers having spherical cavities were fabricated by electrospinning using the spinning solution prepared from the mixed dispersion of tetraethylorthosilicate (TEOS) and polystyrene nanospheres as precursor and sacrificial templates, respectively, by injection through metallic nozzle. By applying electric field, the electro-spun fibers obtained by evaporation-driven self-assembly were collected on flat substrate or rotating drum, followed by the removal of the templates by calcination. The sound absorption coefficient of the porous fibers was measured by impedance tube, and the measured value was larger than 0.9 at high frequency region of incident waves. The surface of the resulting fibers was modified using fluorine-containing silane coupling agent to produce superhydrophobic fibrous materials to prevent the infiltration of humidity.

Reconstruction of the Shoulder using Rotational Latissimus Dorsi Flap in the Malignant Fibrous Histiocytoma (악성 섬유성 조직구종에서 광배근피판을 이용한 견관절 재건술)

  • Han, Chung-Soo;Chung, Duke-Whan;Lee, Young-Ho;Im, Yang-Jin
    • Archives of Reconstructive Microsurgery
    • /
    • v.10 no.2
    • /
    • pp.111-117
    • /
    • 2001
  • Introduction : The Functional muscle transfer is used to reconstruct the injuried muscle and paralysis of the shoulder. Especially transfer of the trapezius has been the treatment of choice but it has disadvantages of inadequate function and deformed contour, and instability of humeral head in case of acromion resection. We report an operation for shoulder reconstruction after wide resection of malignant fibrous histiocytoma, using rotational latissimus dorsi flap and review the operation method and clinical outcome. Materials and Methods : A patient, 53 year old, with malignant fibrous histiocytoma in the acromioclavicular joint area had been underwent wide excision, including the deltoid, clavicular head of pectoralis major, part of trapezius, lateral 1/3 of clavicle and acromion including scapular spine. The rotational latissimus dorsi flap with its neurovascular pedicle was dissected and then placed over the resected area and transfer of muscle attached at coracoid process was done to achieve stability of the humeral head. The range of motion of the shoulder and test of muscle power were evaluated for functional outcome. Total follow-up period is 2 years 11 months. Results : At last follow-up, the range of motion of the shoulder is abduction $90^{\circ}$, flexion $90^{\circ}$, internal rotation $40^{\circ}$, external rotation $50^{\circ}$ and the muscle power is 4 grade in all direction and then we obtained good functional results. There are no complications such as instability or subluxation of the humeral head and deformed contour and he is a disease-free survival state. Conclusions : The transfered latissimus dorsi flap provides adequate lever arm and stabilization and covering of the humeral head by sufficient muscle volume and width. This procedure can be useful not only for the paralysed deltoid reconstruction but also for use in reconstructive surgery after wide resection of the shoulder for malignant tumor.

  • PDF

Use of 3D Printing Model for the Management of Fibrous Dysplasia: Preliminary Case Study

  • Choi, Jong-Woo;Jeong, Woo Shik
    • Journal of International Society for Simulation Surgery
    • /
    • v.3 no.1
    • /
    • pp.36-38
    • /
    • 2016
  • Fibrous dysplasia is a relatively rare disease but the management would be quite challenging. Because this is not a malignant tumor, the preservation of the facial contour and the various functions seems to be important in treatment planning. Until now the facial bone reconstruction with autogenous bone would be the standard. Although the autogenous bone would be the ideal one for facial bone reconstruction, donor site morbidity would be the inevitable problem in many cases. Meanwhile, various types of allogenic and alloplastic materials have been also used. However, facial bone reconstruction with many alloplastic material have produced no less complications including infection, exposure, and delayed wound healing. Because the 3D printing technique evolved so fast that 3D printed titanium implant were possible recently. The aim of this trial is to try to restore the original maxillary anatomy as possible using the 3D printing model, based on the mirrored three dimensional CT images based on the computer simulation. Preoperative computed tomography (CT) data were processed for the patient and a rapid prototyping (RP) model was produced. At the same time, the uninjured side was mirrored and superimposed onto the traumatized side, to create a mirror-image of the RP model. And we molded Titanium mesh to reconstruct three-dimensional maxillary structure during the operation. This prefabricated Titanium-mesh implant was then inserted onto the defected maxilla and fixed. Three dimensional printing technique of titanium material based on the computer simulation turned out to be successful in this patient. Individualized approach for each patient could be an ideal way to restore the facial bone.

Sorption property of fibrous assembly with its fabrication characteristics and various materials (섬유집합체의 구조적 특성 및 소재가 흡수성에 미치는 영향)

  • 이재형;임대영;김성훈
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2002.04a
    • /
    • pp.219-222
    • /
    • 2002
  • 의류, 타월, 와이퍼 등 대부분의 섬유제품은 수분을 흡수하는 능력이 요구되는데, 여기에서 흡수란 고체 표면에 부착되어 있던 비교적 점성이 낮은 액상 물질, 즉 물 및 용제류 등이 섬유 집합체의 표면에 젖으면서 모세관현상에 의해 표면으로부터 내부로 이동한 다음 방출되지 않고 그 상태를 유지하는 현상을 말한다. 이러한 섬유집합체의 흡수 특성을 정확히 규정하기 위해서는 실제와 같은 상황에서 정확하게 흡수 속도와 흡수량을 측정할 수 있는 방법이 요구되는데 기존의 실험 방법들은 미흡한 점이 다소 있었다. (중략)

  • PDF

Behavior of Eutectic Si and Mechanical Properties of Sr Modified Al-7Si-0.35Mg alloy with Solid Solution Treatment for Sand Casting (Sr 개량처리된 사형주조 Al-7Si-0.35Mg 합금의 열처리에 따른 공정 Si상 변화거동 및 특성평가)

  • Kim, Myoung-Gyun;Hwang, Seok-Min
    • Journal of Korea Foundry Society
    • /
    • v.38 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • In this study, we focused on the correlation between the solidification structure, heat treatment and mechanical properties of the A356 alloy according to the conditions of Sr modification. The microstructural evolution of the eutectic Si and ${\alpha}-Al$ phase in the A356 alloy castings depending on the amount of Sr were investigated during solid solution heat treatment using an optical microscope, a scanning electron microscope and an image analyzer. In addition, tensile tests on the heat treated materials examined the relationship between the microstructure and the fracture surface. The as-cast A356 alloys under 40 ppm Sr showed an undermodified microstructure, but that of the added 60-80 ppm Sr had well modified structure of fine fibrous silicon. After solid solution treatment, the microstructure of the undermodified A356 alloy exhibited a partially spheroidized morphology, but the remainder showed the fragmentation of fibrous shaped silicon. The spheroidization of the eutectic silicon in the modified A356 alloys was completed during heat treatment, which was very effective in increasing the elongation. This is supported by the fracture surface in the tensile test.

Shear strength of steel fiber reinforced concrete beams with stirrups

  • Campione, G.;La Mendola, L.;Papia, M.
    • Structural Engineering and Mechanics
    • /
    • v.24 no.1
    • /
    • pp.107-136
    • /
    • 2006
  • The present paper proposes a semi-empirical analytical expression that is capable of determining the shear strength of reinforced concrete beams with longitudinal bars, in the presence of reinforcing fibers and transverse stirrups. The expression is based on an evaluation of the strength contribution of beam and arch actions and it makes it possible to take their interaction with the fibers into account. For the strength contribution of stirrups, the effective stress reached at beam failure was considered by introducing an effectiveness function. This function shows the share of beam action strength contribution on the global strength of the beam calculated including the effect of fibers. The expression is calibrated on the basis of experimental data available in literature referring to fibrous reinforced concrete beams with steel fibers and recently obtained by the authors. It can also include the following variables in the strength previsions: - geometrical ratio of longitudinal bars in tension; - shear span to depth ratio; - strength of materials and fiber characteristics; - size effects. Finally, some of the more recent analytical expressions that are capable of predicting the shear strength of fibrous concrete beams, also in the presence of stirrups, are mentioned and a comparison is made with experimental data and with the results obtained by the authors.

Formation of $Al_2O_3$-Ceramics by Reactive Infiltration of Al-alloy into Insulation Fiber Board (Al-합금의 단열섬유판 반응침투에 의한 $Al_2O_3$-세라믹스의 형성)

  • 김일수
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.5
    • /
    • pp.483-490
    • /
    • 1997
  • Al2O3/metal composites were fabricated by oxidation and reaction of molten Al-alloy into two types of commercial Al2O3-SiO2 fibrous insulation board. The growth rate, composition and microstructure of these materials were described. An AlZnMg(7075) alloy was selected as a parent alloy. Mixed polycrystalline fiber and glass phase fiber were used as a filler. The growth surface of an alloy was covered with and without SiO2. SiO2 powder was employed as a surface dopant to aid initial oxidation of Al-alloy. Al-alloy, SiO2, fiber block and growth inhibitor CaSiO3 were packed sequentially in a alumina crucible and oxidized in air at temperature range 90$0^{\circ}C$ to 120$0^{\circ}C$. The growth rate of composite layer was calculated by measuring the mass increasement(g) per unit surface($\textrm{cm}^2$). XRD and optical microscope were used to investigate the composition and phase of composites. The composite grown at 120$0^{\circ}C$ and with SiO2 dopant showed rapid growth rate. The growth behavior differed a little depending on the types of fiber used. The composites consist of $\alpha$-Al2O3, Al, Si and pore. The composite grown at 100$0^{\circ}C$ exhibited better microstructure compared to that grown at 120$0^{\circ}C$.

  • PDF

A STUDY ON TISSUE RESPONSES OF VARIOUS ALLOPLASTIC MATERIALS FOR RIDGE AUGMENTATION (수종 치조제 이물성형재의 조직반응에 관한 연구)

  • Lee, Jae-Ho;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.1
    • /
    • pp.181-192
    • /
    • 1989
  • Loss of teeth causes the inevitable reduction of residual ridge. Among the various methods solving this problem, hydroxyapatite proved to be useful for correction of ridge defect and irregularity. The purpose of this study is to evaluate the tissue responses of two types Of hydroxyapatites and resin polymer. Calcitite 2040 (Calcitek Inc.), Interpore 200 (Interpore Int.), and HTR polymer (HTR Sciences) were implanted into the jaw of an adult dog. The procedure was designed to obtain the results of 1 week, 2 week, 4 week, and 12 week-intervals. And after 12 weeks from the first operation day, the dog was sacrificed and evaluated histologically by light microscope. The results were as follows : 1. The mucosa was healed after two weeks. 2. After 1 week, there were acute inflammatory cells, but diminished after 2 weeks and were not seen after 12 weeks. 3. The hydroxyapatites implanted in soft tissues were surrounded by fibrous connective tissue. And some foreign body giant cells were found. 4. Calcitite and Interpore particles implanted subperiosteally were surrounded by newly formed bone after 12 months. And direct contact between bone and particles was noted. 5. The HTR particles implanted in soft tissues were encapsulated by fibrous connective tissues. The sample where the particles contacted directly to bone could not obtained by some probable insufficiencies of surgical technique or care of the animal. And the residue of HTR particles was digested by macrophage.

  • PDF