• 제목/요약/키워드: Fiber-optic Spectroscopy

검색결과 31건 처리시간 0.028초

Determination of the Dissociation Constant of Thymol Blue with Diode-Laser/Fiber-Optic Thermal Lensing Spectroscopy

  • 김성호;노영순
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권8호
    • /
    • pp.822-824
    • /
    • 1998
  • The simple and convenient measurement of the dissociation constant of an indicator, thymol blue, was achieved by using a portable diode-laser/fiber-optic thermal lensing spectroscopy, which consisted of a visible diode laser, a photodiode, and an optical fiber. It gives comparable results to the cited value obtained from a conventional UV/VIS spectroscopy.

Milk Fat Analysis by Fiber-optic Spectroscopy

  • Ohtani, S.;Wang, T.;Nishimura, K.;Irie, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제18권4호
    • /
    • pp.580-583
    • /
    • 2005
  • We have evaluated the application of spectroscopy using an insertion-type fiber-optic probe and a sensor at wavelengths from 400 to 1,100 nm to the measurement of milk fat content on dairy farms. The internal reflectance ratios of 183 milk samples were determined with a fiber-optic spectrophotometer at 5$^{\circ}C$, 20$^{\circ}C$ and 40$^{\circ}C$. Partial least squares (PLS) regression was used to develop calibration models for the milk fat. The best accuracy of determination was found for an equation that was obtained using smoothed internal reflectance data and three PLS factors at 20$^{\circ}C$. The correlation coefficients between predicted and reference milk fat at 5$^{\circ}C$, 20$^{\circ}C$ and 40$^{\circ}C$ were r=0.753, r=0.796 and r=0.783, respectively. The predictive explained variances ($Q^2$) of the final model, moreover, were more than 0.550 at all temperatures, and the regression coefficients of determination ($R^2$) were more than 0.6 (60%). Our results indicate that milk has different internal reflectance measured in the range of visible and near infrared wavelengths (400 to 1,100 nm), depending on its fat content.

LYSO 섬광체를 이용한 감마선 분광용 광섬유 방사선 센서의 개발 (Development of Fiber-optic Radiation Sensor Using LYSO Scintillator for Gamma-ray Spectroscopy)

  • 한기택;유욱재;신상훈;전다영;박장연;박병기;이봉수
    • 센서학회지
    • /
    • 제21권4호
    • /
    • pp.287-292
    • /
    • 2012
  • A fiber-optic radiation sensor was fabricated using a sensing probe, a plastic optical fiber, a photomultiplier tube, and a multichannel analyzer for gamma-ray spectroscopy. As an inorganic scintillator of the sensing probe, a LYSO crystal was used. In this study, we obtained the relationship between the photon counts of the fiber-optic radiation sensor and the activity of the radioactive isotope. In addition, the gamma-ray energy spectra were also measured using a fiber-optic radiation sensor to discriminate species of gamma-ray emitters.

핵의학 적용을 위한 광섬유 기반의 알파/베타 검출기의 제작 및 특성분석 (Fabrication and Characterization of a Fiber-Optic Alpha/Beta Detector for Nuclear Medicine Application)

  • 홍승한;유욱재;신상훈;서정기;한기택;전다영;조승현;이봉수
    • 센서학회지
    • /
    • 제21권5호
    • /
    • pp.367-373
    • /
    • 2012
  • We fabricated a fiber-optic alpha/beta detector, which is composed of a sensing probe, a plastic optical fiber, a photomultiplier tube, and a multichannel analyzer, to obtain the energy spectra of radioactive isotopes. As inorganic scintillators of a sensing probe, a ZnS(Ag) film was coupled with a $CaF_2$(Eu) crystal for alpha and beta spectroscopy. In this study, $^{210}Po$ and $^{90}Sr$ were used as alpha and beta sources, respectively, and we measured the radiation energy spectra using a fiber-optic alpha/beta detector to identify alpha and beta emitting radionuclides for nuclear medicine application. Also, the variations of energy spectrum were obtained according to the length of plastic optical fiber.

파장변조 광흡수 분광법을 이용한 농도 계측 기법 (Species Concentration Measurement Technique Using Wavelength Modulation Absorption Spectroscopy)

  • 안재현;김용모
    • 한국분무공학회지
    • /
    • 제9권4호
    • /
    • pp.67-76
    • /
    • 2004
  • Diode laser absorption sensors are advantageous because they may provide fast, sensitive, absolute, and selective measurements of species concentration. These systems are very attractive for practical applications owing to its compactness, reasonable cost, robustness, and ease of use. In addition, diode lasers we fiber-optic compatible and thus enable simultaneous measurements of multiple species along a line-of-sight. Recent advances of room-temperature, near-IR and visible diode laser sources for telecommunication, optical data storage applications make it possible to be applied for combustion diagnostics based on diode laser absorption spectroscopy. Therefore, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor systems are now appearing for variety of applications. The objectives of this research are to develop new gas sensing system and to verify feasibility of this system. Wavelength modulation spectroscopy has been demonstrated in these experiments and has a bright prospect to this diode laser system.

  • PDF

Skin depth profiling by using fiber optic probes in the near infrared

  • Woo, Young-Ah;jung, Suh-Eun;Kim, Hyo-Jin
    • 대한화장품학회:학술대회논문집
    • /
    • 대한화장품학회 2003년도 IFSCC Conference Proceeding Book II
    • /
    • pp.218-218
    • /
    • 2003
  • Recently we showed the prototype portable device for the determination of human skin moisture by using near infrared spectroscopy. In order to optimize the acquiring condition of NIR spectrum of skin and control the target information of water depending the site such as epidermis and dermis, skin depth profiling was investigated changing the distance between illuminations and receiving of radiation in the terminal of fiber probe. The colleted light information could be controlled by changing the distance of the fiber optic probes. It was confirmed that the longer distance we used, the deeper site from the skin surface we could get information from in this study. Four kinds of probes with distances such as 0.03 mm, 0.1 mm, 0.5 mm, and 1.0 mm were used. In addition, the gap size from 0.3 mm to 3.0 mm was studied to control the intensity of water absorbance effectively and to avoid saturation of water absorption. We also investigated the reference materials depending the reflectance ratio for water absorption not to be saturated because of the strong absorptivity of water. Furthermore, spectroscopic information regarding free water and bound water around 1850 nm was investigated by using the different distance of fiber optic probes. This study would be great help to control the spectroscopic information of water to be measured depending the site where water exists.

  • PDF

CHALLENGING APPLICATIONS FOR FT-NIR SPECTROSCOPY

  • Goode, Jon G.;Londhe, Sameer;Dejesus, Steve;Wang, Qian
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.4112-4112
    • /
    • 2001
  • The feasibility of NIR spectroscopy as a quick and nondestructive method for quality control of uniformity of coating thickness of pharmaceutical tablets was investigated. Near infrared spectra of a set of pharmaceutical tablets with varying coating thickness were measured with a diffuse reflectance fiber optic probe connected to a Broker IFS 28/N FT-NIR spectrometer. The challenging issues encountered in this study included: 1. The similarity of the formulation of the core and coating materials, 2. The lack of sufficient calibration samples and 3. The non-linear relationship between the NIR spectral intensity and coating: thickness. A peak at 7184 $cm^{-1}$ was identified that differed for the coating material and the core material when M spectra were collected at 2 $cm^{-1}$ resolution (0.4 nm at 7184 $cm^{-1}$). The study showed that the coating thickness can be analyzed by polynomial fitting of the peak area of the selected peak, while least squares calibration of the same data failed due to the lack of availability of sufficient calibration samples. Samples of coal powder and solid pieces of coal were analyzed by FT-NIR diffuse reflectance spectroscopy with the goal of predicting their ash content, percentage of volatile components, and energy content. The measurements were performed on a Broker Vector 22N spectrometer with a fiber optic probe. A partial least squares model was constructed for each of the parameters of interest for solid and powdered sample forms separately. Calibration models varied in size from 4 to 10 PLS ranks. Correlation coefficients for these models ranged from 86.6 to 95.0%, with root-mean-square errors of cross validation comparable to the corresponding reference measurement methods. The use of FT-NIR diffuse reflectance measurement techniques was found to be a significant improvement over existing measurement methodologies in terms of speed and ease of use, while maintaining the desired accuracy for all parameters and sample forms.(Figure Omitted).

  • PDF

Non-destructive estimation of soluble solids in the intact melon fruits from cross progeny by non-contact mode with a fiber optic probe

  • Ito, Hidekazu;Fukino, Nobuko
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1524-1524
    • /
    • 2001
  • A previous paper(Ito et al., 2000) has described the improvement of the standard error(SEC and SEP) of the predicted soluble solids(Brix) in a melon cultivar by non-contact mode with a fiber optic probe. Then we examined the immature and mature fruits. The objective of this study was to determine if non-contact mode could improve the standard error of the predicted Brix of matured melon fruits from cross progeny as well as the contact mode(usual method). The optical absorption spectrum was measured using a NIR Systems model 6500 spectrophotometer. A commercial spectral program(NSAS ver. 3.27) was used for multiple linear regression analysis. Absorbances of 902 and in the vicinity of 877 nm were included as the independent variables in both multiple regression equations. These wavelengths are key wavelengths for non-destructive Brix determination. When the results for the contact mode and non-contact mode are compared, the latter mode improved the former standard error(SEP and RMS).

  • PDF

베타/감마 동시 측정용 광섬유 이중 검출기의 개발을 위한 기초연구 (Feasibility Study on Development of a Fiber-Optic Dual Detector to Measure Beta- and Gamma-rays Simultaneously)

  • 홍승한;신상훈;심혁인;김선근;전혜수;장재석;김재석;권구원;장경원;유욱재;이봉수
    • 전기학회논문지
    • /
    • 제63권2호
    • /
    • pp.284-290
    • /
    • 2014
  • A fiber-optic beta/gamma dual detector system with two types of sensing probes was fabricated to detect the beta- and gamma-rays simultaneously. As scintillators of the sensing probe type 1, two different inorganic scintillators, $CaF_2(Eu)$ and LYSO(Ce) crystals, were used to obtain the each scintillating efficiency with respect to beta-and gamma-rays and the inherent energy spectra of radioactive isotopes. In the case of the sensing probe type 2, which is composed of two identical inorganic scintillators and a beta shielding material based on the lead, it could discriminate beta- and gamma-rays using a subtraction method. In conclusion, we demonstrated that the proposed fiber-optic beta/gamma dual detector could measure and discriminate beta- and gamma-rays using both energy spectroscopy and subtraction method.

Noninvasive blood glucose monitoring system based on NIR spectroscopy with a contact pressure control device

  • Kang, Na-Roo;Baek, Ju-Hyun;Woo, Young-Ah;Kim, Hyo-Jin
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2-2
    • /
    • pp.67.3-68
    • /
    • 2003
  • The purpose of this study is to improve repeatability of a non-invasive blood glucose measurement. The portable NIR system that was newly integrated by our lab includes a tungsten halogen lamp, a specialized reflectance fiber optic probe and a photo diode array type InGaAs detector, which was developed by a microchip technology based on the lithography. Reflectance NIR spectra of finger tip were recorded by using a fiber optic probe. The probe was fixed in the system and subjects put their finger on the probe head. (omitted)

  • PDF