• 제목/요약/키워드: Fiber posts

검색결과 62건 처리시간 0.031초

Glass Fiber Post와 Composite Resin Core의 전단결합강도 (A STUDY FOR THE BONDING STRENGTH OF COMPOSITE RESIN CORE TO GLASS FIBER POST)

  • 김태형;심준성;이근우
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.415-425
    • /
    • 2005
  • Statement of problem : Fracture of composite resin core will be occulted by progress of crack. Bonding interface of different materials has large possibility of starting point of crack line. Therefore, the bond strength of glass fiber post to composite resin core is important for prevention of fracture. Purpose: This in vitro study tried to find out how to get the higher strength of glass fiber post to composite resin core through surveying the maximum load that fractures the post and cote complex. Materials and methods: 40 specimens made with glass fiber Posts(Style $post^{(R)}$, Metalor, Swiss) and composite resin core ($Z-100^{(R)}$, 3M, USA) were prepared and loaded to failure with push-out type shear-bond strength test in a universal test machine. The maximum fracture load and fracture mode were investigated in the specimens that were restored with four different surface treatments. With the data. ANOVA test was used to validate the significance between the test groups, and Bonferroni method was used to check if there is any significant statistical difference between each test group. Evely analysis was approved with 95% reliance. Results: On measuring the maximum fracture load of specimens, both the treatments of sandblasted and acid-etched one statistically showed the strength increase rather than the control group (p<0.005). The scanning electric microscope revealed that sand blasting made more micro-retention form not only on the resin matrix but on the glass fiber, and acid-etching contributed to increase in surface retention form, eliminated the inorganic particles in resin matrix. Specimen fracture modes investigation represented that sand blasted groups showed lower bonding failure than no-sand blasted groups. Conclusion: Referring to the values of maximum fracture load of specimens, the bonding strength was increased by sand blasting and acid-etching.

Fracture resistance of endodontically treated canines restored with different sizes of fiber post and all-ceramic crowns

  • Turker, Sebnem Begum;Alkumru, Hasan Necdet;Akalin, Buket
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권2호
    • /
    • pp.158-166
    • /
    • 2016
  • PURPOSE. The aim of this study was to determine the fracture resistance and the mode of fracture of endodontically treated teeth restored with different fiber posts and all-ceramic crowns. MATERIALS AND METHODS. Two glass fiber reinforced post systems in two different sizes and polyethylene fiber ribbon in two different thicknesses (n=10) were used. The specimens, restored with all-ceramic crowns, were subjected to a compressive load (in N) delivered at a 130-degree angle to the long axis until a fracture could be noted. The results were analyzed statistically with a One-Way ANOVA test (P<.05). RESULTS. Statistically significant differences were observed between the mean fracture resistance values of Postec, Snowlight, and Kerr Connect thin specimens (P<.0095). The Postec results (395.70 N) were found to be significantly higher than the others. No statistical difference was observed among the thick specimens (P<.2657). The mean fracture resistance values of the Snowlight thick samples were found to be higher than those of the Snowlight thin samples. The specimens were always fractured around the cemento-enamel junction at the palatinal side. No post fracture was observed for the thin Snowlight and Kerr Connect specimens or for the thick Postec and Kerr Connect specimens. Among the common failure types of the specimens, the worst was observed to be the root fracture failure. The highest post dislodgement failure result (80%) was obtained from the thin Kerr Connect specimen. CONCLUSION. In terms of optimizing fracture resistance, the fiber post size selection should be done according to the forces applied to the restored teeth.

Effect of silane activation on shear bond strength of fiber-reinforced composite post to resin cement

  • Kim, Hyun-Dong;Lee, Joo-Hee;Ahn, Kang-Min;Kim, Hee-Sun;Cha, Hyun-Suk
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.104-109
    • /
    • 2013
  • PURPOSE. Among the surface treatment methods suggested to enhance the adhesion of resin cement to fiberreinforced composite posts, conflicting results have been obtained with silanization. In this study, the effects of silanization, heat activation after silanization, on the bond strength between fiber-reinforced composite post and resin cement were determined. MATERIALS AND METHODS. Six groups (n=7) were established to evaluate two types of fiber post (FRC Postec Plus, D.T. Light Post) and three surface treatments (no treatment; air drying; drying at $38^{\circ}C$). Every specimen were bonded with dual-curing resin cement (Variolink N) and stored in distilled water for 24 hours at $37^{\circ}C$. Shear-bond strength (MPa) between the fiber post and the resin cement were measured using universal testing device. The data were analyzed with 1-way ANOVA and by multiple comparisons according to Tukey's HSD (${\alpha}$=0.05). The effect of surface treatment, fiber post type, and the interactions between these two factors were analyzed using 2-way ANOVA and independent sample T-tests. RESULTS. Silanization of the FRC Postec Plus significantly increased bond strength compared with the respective non-treated control, whereas no effect was determined for the D.T. Light Post. Heat drying the silane coupling agent on to the fiberreinforced post did not significantly improve bond strength compared to air-syringe drying. CONCLUSION. The bond strength between the fiber-reinforced post and the resin cement was significantly increased with silanization in regards to the FRC Postec Plus post. Bond strength was not significantly improved by heat activation of the silane coupling agent.

수종의 섬유 강화 레진 포스트의 방사선 불투과도와 식별도 평가 (EVALUATION OF RADIOPACITY AND DISCRIMINABILITY OF VARIOUS FIBER REINFORCED COMPOSITE POSTS)

  • 이은혜;최항문;박세희;김진우;조경모
    • Restorative Dentistry and Endodontics
    • /
    • 제35권3호
    • /
    • pp.188-197
    • /
    • 2010
  • 본 연구의 목적은 수종의 섬유 강화 레진 포스트의 방사선 불투과도와 식별도를 비교하고자 하는 것이다. 이번 실험을 위해 1) FRC Postec Plus (Ivoclar Vivadent AG, Schaan, Liechtenstein) 2) Snowlight (Carbotech, Lewis center, OH, USA) 3) Dentin Post (Komet Brasseler, Lamgo, Germany) 4) Rely-X Fiber Post (3M ESPE, St.paul, MN, USA) 5) D.T.-Light Post (BISCO, Schaumburg, IL,USA ) 6) Luxapost (DMG, Hamburg, Germany) 등 6종의 섬유 강화 레진 포스트를 사용하였다. 각 포스트를 참고 기준으로 사용한 1 mm, 2 mm 간격의 알루미늄 step-wedge와 함께 디지털센서를 사용하여 방사선 촬영하였다. 방사선 불투과도는 각 포스트의 다섯 지점에서 $10{\times}10$ 화소의 평균 회색조 값으로 계산하였고 동일 두께의 알루미늄 당량으로 비교하였다. 치아 시편으로 비슷한 방사선 불투과도를 보이는 상악 전치 6개에 포스트를 식립 후 건조 하악골의 설측에 위치시켜 방사선 사진을 촬영하였다. 포스트만을 촬영한 사진과 치아 시편의 방사선 사진들을 구강악안면방사선과 전공자 3명, 치과보존과 전공자 3명, 일반 치과 의사 3명에게 보여주고 설문지를 작성하도록 요청하였다. 설문지는 포스트와 포스트가 식립된 치아 시편 사진에서 방사선 불투과도가 가장 높은 포스트와 낮은 포스트를 고르는 문항, 치근단과 치관부 끝에서 인접 상아질과 가장 식별이 잘되는 포스트를 고르는 문항을 포함하였다. 실험의 결과는 다음과 같았다. 1. 각 FRC-Post는 다양한 방사선 불투과도를 보였다. 2. 가장 높은 방사선 불투과도와 가장 낮은 방사선 불투과도를 가지는 포스트를 고르는 질문에서 포스트만 나열한 경우 실험군 모두 100%의 정답률을 보였으나 포스트를 치아에 넣고 치조골을 중첩시킨 경우 정답률의 변화를 보였다. 3. 포스트 주변 상아질과 구분되는 정도를 묻는 질문에 대해 시편의 조합 순서를 바꾸자 일관된 식별 결과를 보이지 않았다. 이에 본 연구에 사용한 포스트는 다양한 방사선 불투과도를 보이나 식별 능력에 영향을 미칠 정도의 방사선 불투과도 차이를 보이지 않는 것으로 사료된다.

3D micro-CT analysis of void formations and push-out bonding strength of resin cements used for fiber post cementation

  • Uzun, Ismail Hakki;Malkoc, Meral Arslan;Keles, Ali;Ogreten, Ayse Tuba
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권2호
    • /
    • pp.101-109
    • /
    • 2016
  • PURPOSE. To investigate the void parameters within the resin cements used for fiber post cementation by micro-CT (${\mu}CT$) and regional push-out bonding strength. MATERIALS AND METHODS. Twenty-one, single and round shaped roots were enlarged with a low-speed drill following by endodontic treatment. The roots were divided into three groups (n=7) and fiber posts were cemented with Maxcem Elite, Multilink N and Superbond C&B resin cements. Specimens were scanned using ${\mu}CT$ scanner at resolution of $13.7{\mu}m$. The number, area, and volume of voids between dentin and post were evaluated. A method of analysis based on the post segmentation was used, and coronal, middle and apical thirds considered separately. After the ${\mu}CT$ analysis, roots were embedded in epoxy resin and sectioned into 2 mm thick slices (63 sections in total). Push-out testing was performed with universal testing device at 0.5 mm/min cross-head speed. Data were analyzed with Kruskal-Wallis and Mann-Whitney U tests (${\alpha}=.05$). RESULTS. Overall, significant differences between the resin cements and the post level were observed in the void number, area, and volume (P<.05). Super-Bond C&B showed the most void formation ($44.86{\pm}22.71$). Multilink N showed the least void surface ($3.51{\pm}2.24mm^2$) and volume ($0.01{\pm}0.01mm^3$). Regional push-out bond strength of the cements was not different (P>.05). CONCLUSION. ${\mu}CT$ proved to be a powerful non-destructive 3D analysis tool for visualizing the void parameters. Multilink N had the lowest void parameters. When efficiency of all cements was evaluated, direct relationship between the post region and push-out bonding strength was not observed.

THE FRACTURE CHARACTERISTICS OF GLASS FIBER POST AND CORE ON USING DIFFERENT TYPES OF CORE RESIN MATERIALS

  • Shim Dong-Wook;Shim June-Sung;Lee Seok-Hyung;Lee Keun-Woo
    • 대한치과보철학회지
    • /
    • 제42권3호
    • /
    • pp.280-293
    • /
    • 2004
  • Statement of problem. Glass fiber post is one of recent developments to accommodate esthetic restoration for endodontically treated teeth. This has many advantages over conventional post system in physical properties, esthetic factor, risk of root and restoration fracture, adhesion to core, radiopacity, removal and retrievabilty, biocompatibility and chemical stability. Purpose. This in vitro study was to evaluate the most suitable type of resin core for the glass fiber post through surveying the fracture modes and the maximum load that fractures the tooth. Material and methods. 50 sound maxillary premolars restored with glass fiber posts($ParaPost^{(R)}$ Fiber White) and different types of resin cores(ParaCore, $Z100^{TM}$, $Rebilda^{(R)}$ and $Admira^{(R)}$) were prepared and loaded to faiure in a universal test machine. The maximum fracture load and fracture mode were investigated in the specimens that were restored with resin and those of metal cast and core. With the data, Wilcoxon rank sum test was used to validate the significance between the test groups, and Tukey' s studentized range test was used to check if there is any significant statistical difference between each test group. Every analysis was approved with 95% reliance. Results. On measuring the maximum fracture load of teeth specimens, there was a significant difference between the maximum fracture loads of the tooth specimens. ParaCore showed the highest mean maximum fracture load followed by $Z100^{TM}$. And, the distribution of fracture mode of tooth specimens showed generally Type D, the three parted fracture of the core around the post was mostly seen(62.5%), and specifically, ParaCore showed 90% and $Z100^{TM}$ showed 100% Type D fracture. Conclusion. Referring to the values of maximum fracture load and mean compressive fracture load, ParaCore and $Z100^{TM}$ had high values and are recommended as tooth colored resin core material for glass fiber post. CLINICAL IMPLICATIONS. This study was carried out intending to be of aid in selecting the appropriate resin core for the glass fiber post. The dual cure type composite resin ParaCore and light cure type composite resin $Z100^{TM}$ have good properties and are recommended as tooth colored resin core material for glass fiber post.

색상차이에 따른 FRC-포스트와 코어 사이의 구별 (Discrimination between FRC-post and core according to the color difference)

  • 김주회;김진우;조경모;박세희
    • 구강회복응용과학지
    • /
    • 제31권2호
    • /
    • pp.75-85
    • /
    • 2015
  • 목적: 이번 연구의 목적은 FRC-포스트와 코어가 색상차이에 따라 구별되는 정도를 비교하는 것이다. 연구 재료 및 방법: 실험을 위해 유사한 크기(${\pm}0.5 mm$)와 길이(${\pm}0.5 mm$)의 발치 한 하악 소구치 9개를 근관 형성하고 충전하였다. 3개의 치근을 체온을 재현하기 위해 $37^{\circ}C$ 물이 흐르는 가는 실리콘 튜브로 감은 후 cold mounting resin에 매몰하여 각 3개의 치근이 매몰된 총 3개의 시편을 제작하였다. 개개의 시편 치근에는 3종류의 $Snowpost^{(R)}$, MACRO-$LOCK^{TM}$ POST $ILLUSION^{TM}$ $XRO^{(R)}$, FRC $Postec^{(R)}$ Plus post를 이용하여 각각의 포스트에 맞게 공간을 형성하고 포스트를 접착하였다. 3개의 시편 별로 $Luxacore^{(R)}$ Dual Blue, $Luxacore^{(R)}$ Dual A3 및 $Filtek^{TM}$ Z350 XT A1E로 코어를 축조, 시편 별로 다른 코어를 사용하였다. 각 시편에 대해 온도를 낮추기 위한 압축공기를 불 때와 안 불 때로 나누어 디지털 이미지를 촬영하였다. 치과의사 50명과 치과대학 대학생 50명 총 100명에게 어떤 포스트가 코어와 가장 구별이 잘되는 지를 설문조사 하였다. 결과: $Luxacore^{(R)}$ Dual Blue에서는 $Snowpost^{(R)}$가, $Luxacore^{(R)}$ Dual A3에서는 $Snowpost^{(R)}$가, $Filtek^{TM}$ Z350 A1E에서는 MACRO-$LOCK^{TM}$ POST $ILLUSION^{TM}$ $XRO^{(R)}$가 구별이 가장 잘되었다. 압축공기를 불어 온도를 내리면 나타나는 MACRO-$LOCK^{TM}$ $ILLUSION^{TM}$ $XRO^{(R)}$의 색은 포스트와 코어의 구별을 더 용이하게 하였다. 결론: FRC-포스트와 복합레진 코어가 구별되는 정도는 색상차이에 따라 다름을 알 수 있었다.

Retrospective clinical and radiographic evaluation of restored endodontically treated teeth

  • Paula Pontes Garcia ;Aline Cappoani ;Ricardo Susin Schelbauer ;Gisele Maria Correr ;Carla Castiglia Gonzaga
    • Restorative Dentistry and Endodontics
    • /
    • 제45권4호
    • /
    • pp.49.1-49.11
    • /
    • 2020
  • Objectives: The aim of this study was to perform a clinical and radiographic analysis of endodontically treated teeth (ETT) restored with cast metal posts (CMPs) or prefabricated glass fiber posts (GFPs) and crowns. Materials and Methods: Fifty ETT were restored with 25 CMPs and 25 GFPs at a private dental clinic between 2001 and 2016. The restorations consisted of 12 all-ceramic crowns, 31 metal-ceramic crowns, and 7 composite resin crowns. Demographic data, type of teeth, type of post-and-core system, time of placement, crown restorations, the number of proximal contacts, the type of antagonist, and reports of any complications after post-and-core placement were recorded for each patient. Assessments were performed at baseline (radiographic) and follow-up (radiographic and clinical). Data were analyzed by the McNemar test, the Pearson χ2 test, and Kaplan-Meier survival curves (α = 0.05). The mean follow-up was 67.6 months. Results: No significant difference was observed for any of the radiographic parameters when the baseline and final radiographs were compared. In the clinical evaluation, anatomical form (p = 0.009) and occlusion (p = 0.001) showed significant differences according to the type of crown restoration; specifically, metal-ceramic and all-ceramic crowns outperformed composite resin crowns. Conclusions: CMPs and GFPs showed favorable results for restoring ETT after 6 years of follow-up. All-ceramic and metal-ceramic crowns showed higher survival rates and better clinical outcomes.

A comparative evaluation of fracture resistance of endodontically treated teeth restored with different post core systems - an in-vitro study

  • Makade, Chetana S.;Meshram, Ganesh K.;Warhadpande, Manjusha;Patil, Pravinkumar G.
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권2호
    • /
    • pp.90-95
    • /
    • 2011
  • PURPOSE. To compare the fracture resistance and the mode of failure of endodontically treated teeth restored with different post-core systems. MATERIALS AND METHODS. Root canal treatment was performed on 40 maxillary incisors and the samples were divided into four groups of 10 each. For three experimental groups post space preparation was done and teeth were restored with cast post-core (Group B), stainless steel post with composite core (Group C) and glass fiber post with composite core using adhesive resin cement (Group D). Control group (A) samples were selected with intact coronal structure. All the samples were prepared for ideal abutment preparation. All the samples were subjected to a load of 0.5 mm/min at $130^{circ}$.until fracture occurred using the universal testing machine. The fracture resistance was measured and the data were analyzed statistically. The fracture above the embedded resin was considered to be favorable and the fracture below the level was considered as unfavorable. The statistical analysis of fracture resistance between different groups was carried out with t-test. For the mode of failure the statistical analysis was carried out by Kruskal-Wallis test and Chi-Square test. RESULTS. For experimental group Vs control group the fracture resistance values showed significant differences (P<.05). For the mode of failure the chi-square value is 16.1610, which means highly significant (P=.0009) statistically. CONCLUSION. Endodontically treated teeth without post core system showed the least fracture resistance demonstrating the need to reinforce the tooth. Stainless steel post with composite core showed the highest fracture resistance among all the experimental groups. Teeth restored with the Glass fiber post showed the most favorable fractures making them more amenable to the re-treatment.

다양한 접착 시스템 및 포스트의 표면 처리가 섬유 강화 포스트의 접착 강도에 미치는 영향 (Effect of different adhesive systems and post surface treatments on the push-out bond strengths of fiber-reinforced post)

  • 김민우;안진희;김이경;심혜원
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.218-225
    • /
    • 2016
  • 목적: 본 연구에서는 자가-접착 레진 시멘트의 접착 강도에 포스트의 표면 처리와 접착 시스템이 미치는 영향을 조사하고자 하였다. 재료 및 방법: 비슷한 치근 길이를 가진 48개의 사람 상악 단근치를 사용하여 160개의 시편을 제작하고 접착 시스템에 따라 4개의 군으로 분류하였다(no adhesive, Adper Single Bond 2, Clearfil SE Bond, Clearfil S3). 각 군은 포스트 표면 처리 방식에 따라 다시 4개의 군으로 세분하였다(no treatment, sandblast, silane, sandblast and silane). 포스트를(Parapost Fiber White) Rely X Unicem을 사용하여 접착하였다. 치아를 장축에 수직으로 1 mm 두께로 절단 하였다. Push-out test를 0.5 mm/분의 crosshead speed로 시행하였다. 2-way ANOVA, 1-way ANOVA 검정을 시행하였고 Tukey test를 통한 사후 검정을 시행하였다(${\alpha}=0.05$). 결과: Tukey test를 통한 사후 검정에서 접착 시스템에 따른 차이가 나타났다. Clearfil SE Bond가 가장 높은 접착 강도를 나타내었다. 결론: 상아질에 Clearfil SE bond를 사용하고 포스트를 실란 처리시 가장 높은 접착 강도를 나타내었다.