• Title/Summary/Keyword: Fiber optic components

Search Result 55, Processing Time 0.02 seconds

A Study on the Three Dimensional Statistical Turbulent Flow Characteristics Around a Small-Sized Axial Fan for Refrigerator (냉장고용 소형 축류홴의 통계학적 3차원 난류유동 특성에 관한 연구)

  • Kim, Jang-Gwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.6
    • /
    • pp.819-828
    • /
    • 2001
  • The operating point of a small-sized axial fan is strongly dependent upon the system resistance. Therefore, the turbulent flow characteristics around a small-sized axial fan may change significantly according to the operating point. This study represents three-dimensional turbulent flow characteristics around a small-sized axial fan measured at the ideal design point $\phi$=0.25, which is equivalent to the maximum total efficiency point, by using three dimensional fiber-optic type LDA system. This LDA system is composed of a 5 W Argon-ion laser, two optics in back-scatter mode, three BSAs, a PC, and a three-dimensional automatic traversing system. A kind of paraffin fluid is used to supply particles by means of fog generator. Mean velocity profiles downstream of a small-sized axial fan along the radial distance show that the streamwise and the tangential components exist in a predominant manner, while the radial component has a small scale distribution and shows the inflection which its flow direction is inward or outward. Moreover, the turbulent intensity profiles show that the radial component exists the most greatly among turbulent energies.

Investigation on the Turbulent Flow-Field of a Small-size Axial Fan with Different Operating Points (운전점이 다른 소형 축류홴의 난류 유동장 고찰)

  • Kim, J.K.
    • Journal of Power System Engineering
    • /
    • v.12 no.5
    • /
    • pp.40-47
    • /
    • 2008
  • The turbulent flow characteristics around a small-size axial fan(SSAF) for a refrigerator are strongly dependent upon the operating points. Four operating points such as $\phi$ =0.1, 0.18, 0.25 and 0.32 were adopted in this study to investigate three-dimensional turbulent flow characteristics around the SSAF by using a fiber-optic type Laser Doppler Anemometer(LDA) system. Downstream mean velocity profiles of the SSAF along the radial distance show that axial and tangential velocity components exist predominantly, except $\phi$ = 0.1, and have a maximum value at $r/R{\fallingdotseq}0.8$, but radial velocity component having a relatively small value only turns flow direction to the outside or the central part of the SSAF. The turbulent intensity shows that the radial component exists most greatly after $r/R{\fallingdotseq}0.5$. Downstream turbulent kinetic energy at $\phi$ = 0.25 and 0.32 together has the largest peak value at $r/R{\fallingdotseq}0.9$.

  • PDF

Optical Current Sensors Based on Polarization Rotated Reflection Interferometry (편광회전 반사간섭계를 이용한 광전류센서)

  • Jang, Ji-Hyang;Chu, Woo-Sung;Kim, Hoon;Seo, Jun-Kyu;Kim, Kyung-Jo;Kim, Jun-Whee;Oh, Min-Cheol
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.4
    • /
    • pp.168-174
    • /
    • 2010
  • Fiber optic current sensors based on polarization-rotated reflection interferometry are demonstrated by incorporating them into polymeric optical waveguide components, including polarization-maintaining 3-dB couplers, TE-pass waveguide polarizers, and thermooptic phase modulators. To remove the bending induced birefringence, optical fiber coil is annealed at $850^{\circ}C$ for 24 hours. The reflection interferometry comprising polymer waveguide devices exhibit a highly stable output signal corresponding to the flowing current.

LED Fiber-Optic Lighting Devices Developed for Medical Assistance for the Local Treatment Retractor (국부치료를 위한 Retractor용 LED 광섬유 의료보조조명 장치 개발)

  • Eo, Ik-soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.666-671
    • /
    • 2016
  • This paper introduces a device providing close local lighting to the affected part, where the operation-purpose astral lamp alone cannot shed light directly, in an operation room of hospitals or clinics, which helps clinical doctors perform safe treatment of the affected part deep inside a human body. This medical assisting lighting is a device necessary to prevent fatal operation failures, which can occur with minute operation processes, such as tumor removal or angiorrhaphy. The components, such as the light source and power supply were designed to be low power consuming and small in size, have a narrow angle lens was used to increase the light spreading effect and focused illumination. The end-caps of the light transmission device using an optical cable and the lighting device were designed in the waterproof type to enable disinfection of these devices after use for the next patients. According to the measurement of the light source properties made after development of the retractor lighting device, the illumination intensity was 490 lux, the brightness was $11,550cd/m^2$, general color rendering index was 78, color temperature was 11,000K, and the intensity distribution was even, which were confirmed to be adequate for medical assisting local lighting.

Structural and Optical Properties of Self-assembled InAs/InAl(Ga)Ae Quantum Dots on InP (InP 기판에 성장한 자발형성 InAs/InAl(Ga)As 양자점의 구조 및 광학적 특성)

  • Kim Jin-Soo;Lee Jin-Hong;Hong Sung-Ui;Kwack Ho-Sang;Choi Byung-Seok;Oh Dae-Kon
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.2
    • /
    • pp.194-200
    • /
    • 2006
  • Self-assembled InAs/InAl(Ga)As quantum dots (QDs) were grown on InP substrates by a molecular-beam epiaxy, and their structural and optical properties were investigated by atomic force microscopy (AFM), transmission electron microscopy (TEM), and room-temperature photoluminescence (PL). AFM images indicated that the InAs quantum structures showed various shapes such as quantum dashes, asymmetric and symmetric QDs mainly caused by the initial surface conditions of InAl(Ga)As with the intrinsic phase separation. For the buried InAs QDs in an InAlGaAs matrix, the average lateral size and height of QDs were 23 and 2 nm, respectively. By changing the growth conditions for the QD samples, the emission wavelength of $1.55{\mu}m$ was obtained, which is one of the wavelength windows for fiber optic communications.

Optical pulse parameter analysis of gain switched InGaAIP FP LD at 650 nm wavelegth and its characteristic in comparison with CW operation (이득스위칭을 이용한 650nm InGaAIP FP LD의 광펄스 파라메터 분석 및 CW 발진과의 특성비교)

  • 오광환;채정혜;이용탁;백운출;김덕영
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.2
    • /
    • pp.135-142
    • /
    • 2001
  • Recently, plastic optical fiber draws a lot of attention as a new transmission medium for local area network (LAN) and home network applications. As PMMA based GI-POF (Graded Index Plastic Optical Fiber) has very low loss at about 500 nm and 650 nm wavelengths, it is very important to have a compact ultra short optical pulse source at these wavelength windows. In this paper, we have investigated detailed characteristics of gain switched laser system by using a commercially available low cost RF devices and an InGaAlP Fabry Perot semiconductor laser operating at 650 nm wavelength. The shortest optical 'pulse obtained was 33 psec with 1 GHz repetition rate. Depending on the DC bias current and the modulation frequency, the FWHM and the pulse energy of the gain switched pulses show 33.3-82.8 psec and 0.97-9.69 pI respectively. Also, the spectral bandwidths for CW and gain switched operations are 0.44 nm and 1.50 nm. We believe that these results are quite useful for high bit rate optical transmission applications with PMMA based plastic optical fibers in addition to estimate properties of ultra fast optical components and electro-optic devices. vices.

  • PDF

STABILIZATION OF REFERENCE SIGNAL TRANSMISSION SYSTEM IN RADIO TELESCOPE FOR VLBI (VLBI 전파망원경 기준 신호 전송시스템 안정화)

  • Je, Do-Heung;Lee, Won-Kyu;Kim, Soo-Yeon;Chung, Moon-Hee;Song, Min-Kyu;Jung, Taehyun;Byun, Do-Young;Kim, Seung-Rae;Sohn, Bong-Won;Wi, Seog-Oh;Han, Seog-Tae;Kang, Yong-Woo
    • Publications of The Korean Astronomical Society
    • /
    • v.28 no.3
    • /
    • pp.95-100
    • /
    • 2013
  • A fiber-optic reference signal transmission system, which transmits the 1.4 GHz reference signal from H-maser to receiver cabin in radio telescopes, was adopted for compensating the phase changes due to temperature variation and antenna movement. At the first experiment, the remote signal's phase changed more than 15 degrees at 1.4 GHz. We found unstable components in sub-system experiments and replaced them. The main cause of unstable phase stability was the unaligned polarization axis between Laser Diode and Mach-Zehnder Modulator (MZM). The improved system stability showed $1{\times}10^{-16}$ allan standard deviation at 1,000 sec integration time with the antenna fixed. When the antenna moves in the azimuth axis, the 1.4 GHz remote signal showed the phase change smaller than 0.2 degrees.

A Disposable Grating-Integrated Multi-channel SPR Sensor Chip for Detection of Biomolecule (회절격자가 집적된 일회용 다중채널 SPR 생체분자 검출 칩)

  • Jin, Young-Hyun;Cho, Young-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.147-154
    • /
    • 2009
  • This paper presents a grating~integrated SPR (Surface Plasmon Resonance) sensor chip for simple and inexpensive biomolecule detection. The grating-integrated SPR sensor chip has two sensing channels having a nano grating for SPR coupling. An external mirror is used for multi channel SPR sensing. The present sensor chip replaces bulky and expensive optical components, such as fiber-optic switches or special shaped prisms, resulting in a simple and inexpensive wavelength modulated multi-channel SPR sensing system. We fabricate a SPR sensor chip integrated with 835 nm-pitch gratings by a micromolding technique to reduce the fabrication cost. In the experimental characterization, the refractive index sensitivity of each sensing channel is measured as $321.8{\pm}8.1nm$/RI and $514.3{\pm}8.lnm$/RI, respectively. 0.5uM of the target biomolecule (streptavidin) was detected by a $1.13{\pm}0.16nm$ shift of the SPR dip in the 10%-biotinylated sample channel, while the SPR dip in the reference channel for environmental perturbation monitoring remained at the same position. From the experimental results, multi-channel biomolecule detection capability of the present grating-integrated SPR sensor chip has been verified. On the basis of the preliminary experiments, we successfully measured the binding reaction rate for the $2\;nM{\sim}200\;nM$ monoclonal-antibiotin, thus verifying biomolecule concentration detectability of the present SPR sensor chip. The binding reaction rates measured from the present SPR sensor chip agredd well with those from a commercialized SPR sensor.

A Low-noise Multichannel Magnetocardiogram System for the Diagnosis of Heart Electric Activity

  • Lee, Yong-Ho;Kim, Ki-Woong;Kim, Jin-Mok;Kwon, Hyuk-Chan;Yu, Kwon-Kyu;Kim, In-Seon;Park, Yong-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.4
    • /
    • pp.154-163
    • /
    • 2006
  • A 64-channel magnetocardiogram (MCG) system using low-noise superconducting quantum interference device (SQUID) planar gradiometers was developed for the measurements of cardiac magnetic fields generated by the heart electric activity. Owing to high flux-to-voltage transfers of double relaxation oscillation SQUID (DROS) sensors, the flux-locked loop electronics for SQUID operation could be made simpler than that of conventional DC SQUIDs, and the SQUID control was done automatically through a fiber-optic cable. The pickup coils are first-order planar gradiometers with a baseline of 4 em. The insert has 64 planar gradiometers as the sensing channels and were arranged to measure MCG field components tangential to the chest surface. When the 64-channel insert was in operation everyday, the average boil-off rate of the dewar was 3.6 Lid. The noise spectrum of the SQUID planar gradiometer system was about 5 fT$_{rms}$/$\checkmark$Hz at 100 Hz, operated inside a moderately shielded room. The MCG measurements were done at a sampling rate of 500 Hz or 1 kHz, and realtime display of MCG traces and heart rate were displayed. After the acquisition, magnetic field mapping and current mapping could be done. From the magnetic and current information, parameters for the diagnosis of myocardial ischemia were evaluated to be compared with other diagnostic methods.

A CLINICAL STUDY ON THE MAINTENANCE OF LIGHT INTENSITY OF VISIBLE-LIGHT CURING MACHINES FOR THE POLYMERIZATION OF COMPOSITE RESINS (복합레진 중합용 가시광선 광중합기의 적정 광강도 유지를 위한 임상적 고찰)

  • Lee, Dong-Soo;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.363-368
    • /
    • 2001
  • It is well known that numerous factors influence the light output of curing units, but many dentists are un aware that the output of their curing lights are inadequate. This study was conducted to evaluate the light in tensity of visible-light curing units in some private dental clinics and hospital dental clinics. In order to determine the maximum light intensity of the curing units, lamps, filters and fiber optic bundles, they were replaced with new ones and light intensity was remeasured. Light intensity was measured by employing a digital radiometer (EFOS model #8000, USA). Light intensity ranged in $29\sim866mW/cm^2$ (below $150mW/cm^2$ ; 17.8%, $150\sim300mW/cm^2$ : 46.6%, above $300mW/cm^2$ ; 35.6%). The replacement of the components increased the light intensity, with maximum increases of 94.8% for lamps, 82.3% for filters, 200.8% for fiber optics and 361.5% for all three parts. According to the manufacturer of radiometer, curing light is considered as unsuitable for use with a reading of above $300mW/cm^2$ by the radiometer. Applying these criteria to the present study, 64.4% of the curing units required repair or replacement. The results of this study indicated that the light intensities of the curing units used in dental practice were lower than optimum level.

  • PDF