• 제목/요약/키워드: Fiber Tip

검색결과 150건 처리시간 0.032초

SLD 광원을 이용한 광섬유 패브리페로 센서 (Fiber Fabry-Perot Sensor using SLD Light Source)

  • 김광수;이병윤;이홍식;임근희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2186-2188
    • /
    • 2000
  • A fiberoptic sensor using an SLD as a light source has been studied. The sensor system employs an intrinsic fiber Fabry-Perot interferometer as a sensing tip and a fiber Mach-Zehnder interferometer as a processing one. A free loading test for temperature application shows that the fiberoptic sensor has a wide-dynamic range as well as high resolution. Due to the inherent property of the optical fiber itself and the intrinsic Fabry-Perot interferometer. the fiberoptic sensor gives obvious benefits when it is applied to harsh environments to monitor some physical parameters such as temperature, strain, pressure and vibration.

  • PDF

복합재료의 계면 전단강도를 평가하기 위한 새로운 반구형 미소접합 시험편 (A novel hemispherical microbond specimen for evaluating the interfacial shear strength of single fiber composite)

  • 박주언;최낙삼
    • Composites Research
    • /
    • 제21권2호
    • /
    • pp.25-30
    • /
    • 2008
  • A hemispherical microbond specimen adhered onto single carbon fiber has been proposed for evaluating the interfacial shear strength between epoxy and carbon fiber. Hemispherical microbond specimens showed low interfacial shear strength data and its small standard deviation as compared with the droplet one, which seemed to be caused by the reduction of the meniscus effects and of the stress concentration in the region contacting with the tip of pin hole. In comparison with the droplet specimen the hemispherical specimen showed the shear stress distribution similar to the cylindrical one in that low stress concentration arose around the contacting region. Average interfacial shear strength obtained by the hemispherical ones represented a good correlation with the hardness of the epoxy matrix.

열변성 물질을 이용한 지하수 온도 측정용 광섬유 온도센서의 특성분석 (Characteristic analysis of a thermochromic material based fiber-optic temperature sensor for measuring temperature of subsurface water)

  • 서정기;유욱재;조동현;장경원;허지연;이봉수;고용권
    • 센서학회지
    • /
    • 제18권6호
    • /
    • pp.467-474
    • /
    • 2009
  • In this study, we describe the feasibility of developing a fiber-optic temperature sensor using a thermochromic material such as 2,4,5-triphenylimidazole or also called Lophine. A sensor-tip is fabricated by mixing of a Lophine powder, which has a non-toxic and hydrophobic characteristics, and an epoxy resin. The temperature change in the sensor-tip gives rise to a change in the optical absorbance of the Lophine, and the transmittance of a light through the Lophine is also changed. We have measured the intensities of modulated lights due to the change of optical absorbance of the Lophine by using of a photo-multiplier tube(PMT). The relationships between the temperatures and the output voltages of PMT are determined to measure the temperature of water. The measurable temperature range of the fiber-optic sensor is from 5 to $30^{\circ}C$.

광섬유 대량생산용 인출퍼니스 내 유리섬유 인출공정의 전산해석 (COMPUTATIONAL STUDY OF GLASS FIBER DRAWING PROCESS IN A DRAW FURNACE OF OPTICAL FIBER MASS MANUFACTURING SYSTEM)

  • 김경진;곽호상;김동주
    • 한국전산유체공학회지
    • /
    • 제18권4호
    • /
    • pp.69-73
    • /
    • 2013
  • Mass manufacturing of optical fiber includes the process of very thin glass fiber drawing by heating and softening the high purity silica preform and applying the draw tension on the softened tip of preform neck-down profile in a draw furnace. In this computational study, this process is numerically modeled with simplified geometry of the draw furnace which is comprised of essential parts such as concentric graphite heater, muffle tube, and insulation surrounding the heater. The iterative computational scheme is employed between one-dimensional model of neck-down profile prediction and two-dimensional axisymmetric thermo-fluid CFD computation of radiative heating and working gas convection. The computational results show the experimentally observed neck-down profile in heated section of preform, while yielding the reasonable values of draw tension and heater wattage. Also, this study analyzes and discusses the effects of heating conditions such as heater length and temperature on several important aspects of glass fiber drawing process.

MFC 센서를 이용한 응력 확대 계수 측정에 관한 연구 (A Study of Stress Intensity Factors using Micro Fiber Composite Sensors)

  • 오동진;김명현
    • Journal of Welding and Joining
    • /
    • 제29권3호
    • /
    • pp.76-81
    • /
    • 2011
  • Recently, the structural failures due to fatigue occur frequently with the increase of size of ships and offshore structures. In this respect, the assessment of fatigue life and the residual strength are very important. Currently, the smart materials technology has demonstrated a variety of possibilities for a diagnosis of structural strength and structural health condition for large structures. The benefits and feature of the MFC sensor are more flexible, durable and reliable than conventional smart material. In this study, Micro Fiber Composite (MFC) sensor for the measurement of stress intensity factor (SIF) of two dimensional cracks induced in a structure is developed. Two MFC sensors are placed in the vicinity of the crack tip close to each other with the crack tip in between them. The SIFs of Mode I($K_I$) as well as of Mode II($K_{II}$) based on the piezoelectric constitutive law and fracture mechanics are calculated. In this study, the SIF values measured by MFC sensors are compared with the theoretical results and measured value.

Evaluation of Crack Propagation and Post-cracking Hinge-type Behavior in the Flexural Response of Steel Fiber Reinforced Concrete

  • Gali, Sahith;Subramaniam, Kolluru V.L.
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권2호
    • /
    • pp.365-375
    • /
    • 2017
  • An experimental evaluation of crack propagation and post-cracking behavior in steel fiber reinforced concrete (SFRC) beams, using full-field displacements obtained from the digital image correlation technique is presented. Surface displacements and strains during the fracture test of notched SFRC beams with volume fractions ($V_f$) of steel fibers equal to 0.5 and 0.75% are analyzed. An analysis procedure for determining the crack opening width over the depth of the beam during crack propagation in the flexure test is presented. The crack opening width is established as a function of the crack tip opening displacement and the residual flexural strength of SFRC beams. The softening in the post-peak load response is associated with the rapid surface crack propagation for small increases in crack tip opening displacement. The load recovery in the flexural response of SFRC is associated with a hinge-type behavior in the beam. For the stress gradient produced by flexure, the hinge is established before load recovery is initiated. The resistance provided by the fibers to the opening of the hinge produces the load recovery in the flexural response.

Toluene-o-monooxygenase와 Fluoresceinamine을 이용한 Trichloroethene와 Tetrachloroethene 감지용 광섬유 바이오센서의 특성 (Characteristics of Trichloroethene and Tetrachloroethene Sensing Optical Fiber Biosensor Using Toluene-o-monooxygenase and Fluoresceinamine)

  • 류두현
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제23권4호
    • /
    • pp.42-47
    • /
    • 2018
  • E. coli TG1 pBS TOM Green was cultured to produce toluene-o-monooxygenase (TOM). A biosensor system was successfully constructed using purified TOM to effectively detect trichloroethene (TCE) and tetrachloroethene (PCE), which represent some of the major contaminants in groundwater and soil. In order to utilize TOM as a sensor, NADH, a biological oxidizer, was replaced with hydrogen peroxide which is a chemical oxidizing agent. A three-layered sandwich-type sensing tip was fabricated on the outside of the hydrophilic polyvinylidene fluoride membrane. TCE and PCE were applied to the sensor and the hydrogen ions were measured by a fiber optic fluorometer using fluoresceinamine. Calibration curves were obtained for TCE and PCE in the concentration range of 0.2-100 mg/l, and the detection limit of the system was $10{\mu}g/l$ for TCE and PCE.

Design of a High-efficiency Fiber-to-chip Coupler with Reflectors

  • Yoo, Keon;Lee, Jong-Ho
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제5권2호
    • /
    • pp.123-128
    • /
    • 2016
  • In this paper, an inversely tapered coupler with Bragg reflectors is reported for the first time. With appropriately positioned reflecting structures, our fiber-to-chip coupler can more efficiently transmit the light from fiber to a waveguide in a photonic integrated circuit (PIC). A numerical simulation evaluated the coupler's efficiency with the reflector. Optimized parameters that maximize the efficiency of the coupler are also investigated. Simulation results show that the reflector with appropriate parameters enhances efficiency by up to 7 dB. Likewise, Bragg metal reflectors implemented by the conventional metallization process can also improve efficiency. It is also shown that the proposed reflector enhances the coupling efficiency in a double-tip taper coupler.

Response of fiber reinforced plastic chimneys to wind loads

  • Awad, A.S.;El Damatty, A.A.;Vickery, B.J.
    • Wind and Structures
    • /
    • 제3권2호
    • /
    • pp.83-96
    • /
    • 2000
  • Due to their high corrosion and chemical resistance, fiber reinforced plastics (FRP) are becoming widely used as the main structural material for industrial chimneys. However, no national code currently exists for the design of such type of chimneys. The purpose of this study is to investigate analytically the response of FRP chimneys to wind loads. The classical lamination theory is used to substitute the angle-ply laminate of a FRP chimney with an equivalent orthotropic material that provides the same stiffness. Dynamic wind loads are applied to the equivalent chimney to evaluate its response to both along and across wind loads. A parametric study is then conducted to identify the material and geometric parameters affecting the response of FRP chimneys to wind loads. Unlike the across-wind response, the along-wind tip deflection is found to be highly dependent on the angle of orientation of the fibers. In general, the analysis shows that FRP chimneys are very vulnerable to across-wind oscillations resulting from the vortex shedding phenomenon.