• Title/Summary/Keyword: Fiber Reinforced Plastic(FRP)

Search Result 177, Processing Time 0.022 seconds

A Study on the Shear Resisting Effect of Filling-up Carbon Fiber Rod Plastic in Reinforced Concrete Beam without Web Reinforcement (전단보강근이 없는 철근콘크리트보의 매립형 CFRP 전단보강효과에 대한 연구)

  • Kim, Young-Sik;Park, Sung-Moo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.5 no.2 s.16
    • /
    • pp.57-63
    • /
    • 2005
  • The reinforced concrete becomes deteriorated. In strengthening of reinforced concrete structure, it is recently useing FRP. The purpose of this study is to investigate the shear resisting effort of filling-up CFRP in reinforced concrete beams without web reinforced. Six specimens were manufactured and tested. In the test result, it was analysis. The main variables in the test were a space and volume of CFRP.

  • PDF

Computational material modeling of masonry walls strengthened with fiber reinforced polymers

  • Koksal, H. Orhun;Jafarov, Oktay;Doran, Bilge;Aktan, Selen;Karakoc, Cengiz
    • Structural Engineering and Mechanics
    • /
    • v.48 no.5
    • /
    • pp.737-755
    • /
    • 2013
  • This paper aims to develop a practical approach to modeling of fiber reinforced polymers (FRP) strengthened masonry panels. The main objective is to provide suitable relations for the material characterization of the masonry constituents so that the finite element applications of elasto-plastic theory achieves a close fit to the experimental load-displacement diagrams of the walls subjected to in-plane shear and compression. Two relations proposed for masonry columns confined with FRP are adjusted for the cohesion and the internal friction angle of both units and mortar. Relating the mechanical parameters to the uniaxial compression strength and the hydrostatic pressure acting over the wall surface, the effects of major and intermediate principal stresses ${\sigma}_1$ and ${\sigma}_2$ on the yielding and the shape of the deviatoric section are then reflected into the analyses. Performing nonlinear finite element analyses (NLFEA) for the three walls tested in two different studies, their stress-strain response and failure modes are eventually evaluated through the comparisons with the experimental behavior.

Experimental Study on the Stress Variation of Concrete Containing F-fiber Extracted from Waste FRP (폐 FRP로부터 분리한 F-섬유를 이용한 콘크리트 강도 특성 변화에 대한 실험적 연구)

  • Yoon, Koo Young;Park, Jong Won;Lee, Seung Hee
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.1
    • /
    • pp.42-45
    • /
    • 2014
  • Even though to discard the waste FRP (Fiber-Reinforced Plastic) is urgent and problematic, the way to do it has not been efficient. In our project team the FRP have been splitted into some layers which have different physical properties; mat and roving layers. Among those, the roving layer woven like a basket by bundles of glass fibers has been cut into reusable fibers called 'F-fiber'. F-fiber is 1 mm or 3 mm in width and 3 cm in length. It is used in fiber-reinforced concrete (FRC) with 0.5%, 0.7%, 1.0%, or 1.5% of volume ratio. Produced FRC was tested in compressive, tensile, and bending stress in contrast to the without-fiber (standard) concrete and 0.1% polypropylene reinforced concrete (PP-FRC). The tensile and bending stresses are more or less those of PP-FRC. The compressive stress, however, is similar (with 3 mm F-fiber) to or lower (with 1 mm F-fiber) than that of standard concrete. Conclusively the usage of the waste FRC in concrete is advised to be limited to the one where the compressive stress is not much critical.

Numerical and experimental investigation for damage detection in FRP composite plates using support vector machine algorithm

  • Shyamala, Prashanth;Mondal, Subhajit;Chakraborty, Sushanta
    • Structural Monitoring and Maintenance
    • /
    • v.5 no.2
    • /
    • pp.243-260
    • /
    • 2018
  • Detection of damages in fibre reinforced plastic (FRP) composite structures is important from the safety and serviceability point of view. Usually, damage is realized as a local reduction of stiffness and if dynamic responses of the structure are sensitive enough to such changes in stiffness, then a well posed inverse problem can provide an efficient solution to the damage detection problem. Usually, such inverse problems are solved within the framework of pattern recognition. Support Vector Machine (SVM) Algorithm is one such methodology, which minimizes the weighted differences between the experimentally observed dynamic responses and those computed using the finite element model- by optimizing appropriately chosen parameters, such as stiffness. A damage detection strategy is hereby proposed using SVM which perform stepwise by first locating and then determining the severity of the damage. The SVM algorithm uses simulations of only a limited number of damage scenarios and trains the algorithm in such a way so as to detect damages at unknown locations by recognizing the pattern of changes in dynamic responses. A rectangular fiber reinforced plastic composite plate has been investigated both numerically and experimentally to observe the efficiency of the SVM algorithm for damage detection. Experimentally determined modal responses, such as natural frequencies and mode shapes are used as observable parameters. The results are encouraging since a high percentage of damage cases have been successfully determined using the proposed algorithm.

Numerical Study for Seismic Strengthening of RC columns Using Fiber Reinforced Plastic Composite (기둥의 내진성능 향상을 위한 섬유보강 복합체의 적용성에 대한 해석적 연구)

  • Chang, Chun Ho;Kwon, Min Ho;Kim, Jin Sup;Joo, Chi Hong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.3
    • /
    • pp.117-127
    • /
    • 2012
  • As increasing number of large-size earthquake around Korean peninsula, many interests have been focused to the earthquake strengthening of existing structures. Fiber reinforced plastic composite material is one of strengthening material widely used to increase seismic performance of structures. It should have high stiffness as well as large ductility to provide best strengthening result. Thus selection of stiffener and fiber in composite is of important. In this study, the optimal combination of fiber and stiffener is selected with variety of tensile tests. In order to investigate performance of chosen composite material, several finite element analyses are performed with proposed FRP composite material for existing RC columns. It is discussed that the seismic performance of strengthened columns through the load-displacement relationship. It is shown that the proposed composite material can increase the strength as well as ductility of exiting RC columns.

Development of Element Technique for the Floating PV Generation Structure Using FRP (FRP를 활용한 수상 부유식 태양광발전 구조물의 요소기술 개발)

  • Seo, Su-Hong;Choi, Jin-Woo;Joo, Hyung-Joong;Nam, Jeong-Hun;Yoon, Soon-Jong
    • Composites Research
    • /
    • v.27 no.3
    • /
    • pp.103-108
    • /
    • 2014
  • Fiber reinforced polymer plastic (FRP) structural members are recently available in construction industries due to various material properties such as high specific strength and stiffness, light-weight, and corrosionresistance. The floating PV generation structure can also be an illustration for applying FRP in construction applications. The floating PV generation structure has been recently issued as a representative item for the low carbon and green growth campaign and many related studies have been conducted for the structural safety and commercial viability. Moreover, the floating PV generation structures for the commercial purpose have been constructed. In this paper, the investigation and development processes of elements for the floating PV generation structure are presented during commercialization.

Strength and strain enhancements of concrete columns confined with FRP sheets

  • Campione, G.;Miraglia, N.;Papia, M.
    • Structural Engineering and Mechanics
    • /
    • v.18 no.6
    • /
    • pp.769-790
    • /
    • 2004
  • The compressive behavior up to failure of short concrete members reinforced with fiber reinforced plastic (FRP) is investigated. Rectangular cross-sections are analysed by means of a simplified elastic model, able also to explain stress-concentration. The model allows one to evaluate the equivalent uniform confining pressure in ultimate conditions referred to the effective confined cross-section and to the effective stresses in FRP along the sides of section; consequently, it makes it possible to determine ultimate strain and the related bearing capacity of the confined member corresponding to FRP failure. The effect of local reinforcements constitute by single strips applied at corners before the continuous wrapping and the effect of round corners are also considered. Analytical results are compared to experimental values available in the literature.

Optimization of Lightened Fiber-Reinforced Composite City & Trekking Bicycle Frame (섬유강화복합재료를 사용한 일반용 경량화 자전거 프레임의 최적설계)

  • Yoon, Won Sok;Kim, Do Hyung;Kim, Hak Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.2
    • /
    • pp.147-156
    • /
    • 2016
  • In this paper, optimal designs of bicycle frame were studied for weight reduction of bicycle using carbon-fiber-reinforced plastic (CFRP), glass-fiber-reinforced plastic (GFRP) and Kevlar-fiber-reinforced plastic (KFRP), respectively. Based on the anisotropic properties of FRP material, stacking angle and thickness optimization were performed under the safety reference of European committee for standardization (CEN) to ensure the stability of bicycle frame. Finally, performances of FRP bicycle frame was evaluated by digital logic method based on the optimized results of weight, strength properties and cost. Then, the optimized bicycle frame composed of each FRPs were evaluated and ranked by total performance values.

A Study on the Impact Fracture Behavior of Side Plate for G/T 35ton Class FRP Vessel (35톤급 FRP선박 외판자재의 충격파괴거동에 관한 연구)

  • Lee, Jin-Jeong
    • Journal of Korea Ship Safrty Technology Authority
    • /
    • no.7 s.25
    • /
    • pp.64-76
    • /
    • 2008
  • This paper describes the failure mechanism and Charpy impact test of Fiber glass Reinforced Plastic composites which it was actually used for side plate of vessel. There are two examinations. The examination I, the specimens which it given temperature range $-25^{\circ}C$-$50^{\circ}C$ and with different initial notch length did impact test and then it compared impact energy(Uc) and impact fracture toughness(GIC). The examination II, the specimens which it putted into fresh water and sea water for scheduled hours did impact test and it compared impact energy(Uc) and impact fracture toughness(GIC). From examination I, it showed that impact energy(Uc) and impact fracture toughness(GIC) were peak at ambient temperature and decrease as temperature reduced. Fracture toughness(GIC) showed increase as initial notch length reduced. From examination II, impact energy(Uc) and impact fracture toughness(GIC) tended to increase which specimens putted in fresh water compared with sea water and maximum tolerance rate tend to decrease as permeation hours will be long.

  • PDF