• Title/Summary/Keyword: Ffowcs-Williams and Hawkings Model

Search Result 21, Processing Time 0.024 seconds

Acoustic Analysis of Unevenly Pitched Fan of Automobile Cooling Pack System (자동차 Cooling Fan용 비등각 축류홴 소음해석)

  • Song, W.-S.;Lee, J.-S.;Kim, J.-Y.;Lee, S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.567-571
    • /
    • 2004
  • The 2-dimensional unsteady flows on and around the cambered airfoils were computed by applying LES with the deductive dynamic SGS model. The unsteady flow field were used as inputs to compute the far-field sounds and directivity patterns from rotating blades by a hybrid approach that exploits Farassat's formula. The BEM (Boundary Element Method) was applied to predict the frequency characteristics from the rotating blades for the cases of even- and uneven-pitched fans. The BEM results suggested that the unevenly pitched fan have less pronounced discrete peaks at BEF frequencies, which was confirmed by the experiment.

  • PDF

Numerical investigation on cavitation and non-cavitation flow noise on pumpjet propulsion (펌프젯 추진기의 공동 비공동 유동소음에 대한 수치적 연구)

  • Garam Ku;Cheolung Cheong;Hanshin Seol;Hongseok Jeong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.3
    • /
    • pp.250-261
    • /
    • 2023
  • In this study, the noise contributions by the duct, stator and rotor, which are the propulsor components, are evaluated to identify the flow noise source in cavitation and non-cavitation conditions on pumpjet propulsion and the noise levels in both conditions are compared. The unsteady incompressible Reynolds averaged Navier-Stokes (RANS) equation based on the homogeneous mixture assumption is applied on the suboff submarine hull and pumpjet propeller in the cavitation tunnel, and the Volume of Fluid (VOF) method and Schnerr-Sauer cavitation model are used to describe the two-phase flow. Based on the flow simulation results, the acoustic analogy formulated by Ffowcs Williams and Hawkings (FW-H) equation is applied to predict the underwater radiated noise. The noise contributions are evaluated by using the three types of impermeable integral surface on the duct, stator and rotor, and the two types of permeable integral surface surrounding the propulsor. As a result of noise prediction, the contribution by the stator is insignificant, but it affects the generation of flow noise source due to flow separation in the duct and rotor, and the noise is predominantly radiated into the upward and right where the flow separations are. Also, the noise is radiated into the thrust direction due to pressure fluctuation between suction and pressure sides on the rotor blades, and the it can be seen that the cavitation effect into the noise can be considered through the permeable integral surface.

Development of high performance and low noise axial-flow fan for cooling machine room of refrigerator using airfoil-cascade analysis and surface ridge shape (익렬 분석 및 표면 돌기 형상을 이용한 냉장고 기계실 냉각용 고성능/저소음 축류팬 개발)

  • Choi, Jinho;Ryu, Seo-Yoon;Cheong, Cheolung;Kim, Tae-hoon;Koo, Junhyo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.6
    • /
    • pp.515-523
    • /
    • 2020
  • This study aims to improve the flow and noise performances of an axial-flow fan for cooling the machine room in a refrigerator by using airfoil-cascade analysis and surface ridge shape. First, the experimental evaluations using a fan performance tester and an anechoic chamber are performed to analyze the flow and noise performances of the existing fan system. Then, the corresponding flow and noise performances are numerically assessed using the Computational Fluid Dynamics (CFD) techniques and the Ffowcs-Williams and Hawkings (FW-H) equation, and the validity of numerical results are confirmed through their comparisons with the experimental results. The analysis for the flow of a cascade of airfoils constructed from the existing fan blades is performed, and the pitch angles for the maximum lift-to-drag ratio are determined. The improved flow performance of the new fan applied with the optimum pitch angles is confirmed. Then, the fan blades with surface ridges on their pressure sides are devised, and the reduction of aerodynamic noise of the ridged fan is numerically confirmed. Finally, the prototype of the final fan model is manufactured, and improvements in the flow and noise performances of the prototype are experimentally confirmed.

Investigation on relative contribution of flow noise sources of ship propulsion system (선박 추진시스템 유동 소음원 상대적 기여도 분석)

  • Ha, Junbeom;Ku, Garam;Cheong, Cheolung;Seol, Hanshin;Jeong, Hongseok;Jung, Minseok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.3
    • /
    • pp.268-277
    • /
    • 2022
  • In this study, each component of flow noise source of underwater propeller installed to the scale model of the KVLCC2 is investigated and the effect of each noise source on underwater-radiated noise is quantitatively analyzed. The computation domain is set to be the same as the test section of the large cavitation tunnel in the Korea Research Institute of Ship and Ocean Engineering. First, for the high-resolution computation of flow field which is noise source region, the incompressible multiphase Delayed Detached Eddy Simulation is performed. Based on flow simulation results, the Ffowcs Williams and Hawkings integral equation is used to predict underwater-radiated noise and its validity is confirmed through the comparison with the tunnel experiment result. For the quantitative comparison on the contribution of each noise source, the spectral levels of sound pressure and power levels predicted using propeller tip-vortex cavitation, blade surface and rudder surface as the integral region of noise sources are investigated. It is confirmed that the cavitation which is monopole noise source significantly contributed to the underwater-radiated noise than propeller blades and rudder which is dipole noise source, and the rudder have more contribution than propeller blades due to the influence of the propeller wake.

Numerical Investigation of Cavitation Flow Around Hydrofoil and Its Flow Noise (수중익형 주변 유동장에서의 공동현상과 유동소음에 대한 수치적 연구)

  • Kim, Sanghyeon;Cheong, Cheolung;Park, Warn-Gyu;Seol, Hanshin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.2
    • /
    • pp.141-147
    • /
    • 2016
  • Underwater cavitation is one of the most important issues because it causes not only vibration and erosion of submerged bodies but also significant flow noise problems. In this paper, flow noise due to cavitation flows around the NACA66 MOD hydrofoil is numerically investigated. The cavitation flow simulation is conducted using the Reynolds-Averaged Navier-Stokes equations based on finite difference methods. To capture the cavitation phenomena accurately and effectively, the homogeneous mixture model with the Merkle's cavitation model is applied. The predicted results are compared with available experimental data in terms of pressure coefficients and volume fraction, which confirms the validity of numerical results. Based on flow field analysis results, hydro-acoustic noise field due to the cavitation flow is predicted using the Ffowcs-Williams and Hawkings equation derived from the Lighthill's acoustic analogy. The typical lift dipole propagation patterns are identified.

A study on the numerical method to predict the accurate aeroacoustic noise on axial fan (축류팬의 유동소음 정확도 향상을 위한 수치해석에 관한 연구)

  • Jean, Wan-Ho;Lim, Tae-Gyun;Minorikawa, Gaku
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.311-318
    • /
    • 2013
  • The paper describes the prediction method for the unsteady flow field and the aeroacoustic noise of an small axial fan. The prediction method is comprised of various CFD conditions and acoustic analogy by using Ffowcs Williams-Hawkings equation. The diameter of tested axial fan is 170 mm and number of blade is 5. Virtual anechoic room which has same size with real one was used for CFD. URANS and LES models were used. For mesh dependence study, a different mesh type was tested and optimized mesh was selected. Calculation conditions were also studied such as time step and turbulence model for accurate noise analysis. In this paper, we got optimum analysis conditions and computational results. The unsteady pressure fluctuation at given 4 points were compared between the measured data and computational results. Also, the predicted acoustic spectrum at 3 given microphone points were compared with measured ones.

  • PDF

THE AERO-ACOUSTIC ANALYSIS FOR EACH PART OF DOUBLE ARM PANTOGRAPH OF HIGH SPEED TRAIN (전산해석을 통한 고속철도 더블암 팬터그래프의 부재별 공력소음특성 연구)

  • Lee, S.A.;Kang, H.M.;Lee, Y.B.;Kim, C.W.;Kim, K.H.
    • Journal of computational fluids engineering
    • /
    • v.20 no.2
    • /
    • pp.61-66
    • /
    • 2015
  • In this study, an aero-acoustic analysis around pantograph of a high speed train is performed. Computational technique and grid system is validated with wind tunnel test result and unsteady acoustic pressure data are used for analyzing noise level of each part of pantograph. FLUENT is used for flow analysis and LES(Large Eddy Simulation) is applied for analyzing turbulent flow. For acoustic analysis, Ffowcs Williams-Hawkings(FW-H) acoustics model is used and it bring the aero-acoustic characteristic of pantograph. As the result, contact strip, knee, substructure of pantograph is confirmed as a main source of aero-acoustic noise and it is dealt in various frequencies. The result is expected to help building improved grid system.

Optimization of impeller blade shape for high-performance and low-noise centrifugal pump (고성능 저소음 원심펌프 개발을 위한 임펠러 익형 최적설계)

  • Younguk Song;Seo-Yoon Ryu;Cheolung Cheong;Tae-hoon Kim;Junhyo Koo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.519-528
    • /
    • 2023
  • The aim of this study was to enhance the flow rate and noise performance of a centrifugal pump in dishwashers by designing an optimized impeller shape through numerical and experimental investigations. To evaluate the performance of the target centrifugal pump, experiment was conducted using a pump performance tester and noise experiment was carried out in a semi-anechoic chamber with microphones and a reflecting wall behind the dishwasher. Through the use of advanced computational fluid dynamics techniques, numerical simulations were performed to analyze the flow and aeroacoustics performance of our target centrifugal pump impeller. To achieve this, numerical simulations were carried out using the Reynolds-Average Navier-Stokes equations and Ffowcs-Willliams and Hawkings equations as governing equations. In order to ensure the validity of numerical methods, a thorough comparison of numerical results with experimental results. After having confirmed the reliability of the current numerical method of this study, the optimization of the target centrifugal pump impeller was conducted. An improvement in flow rate was confirmed numerically, and a manufactured proto-type of the optimized model was used for experimental investigation. Furthermore, it was observed that by applying the fan law, we could effectively reduce noise levels without reducing the flow rate.

PERFORMANCE ASSESSMENT OF THE RANS TURBULENCE MODELS IN PREDICTION OF AERODYNAMIC NOISE FOR AIR-CONDITIONER INDOOR UNIT (에어컨 실내기의 공력소음 예측을 위한 RANS 난류모델의 성능 평가)

  • Min, Y.H.;Kang, S.;Hur, N.;Lee, C.;Park, J.
    • Journal of computational fluids engineering
    • /
    • v.17 no.4
    • /
    • pp.81-86
    • /
    • 2012
  • The objective of the present study is to investigate the effects of various turbulence models on the aerodynamic noise of an air-conditioner (AC) indoor unit. The results from URANS (unsteady Reynolds-averaged Navier-Stokes) simulations with the standard k-$\varepsilon$, k-$\omega$ shear stress transport (SST) and Spalart-Allmaras (S-A) turbulence models were analyzed and compared with the noise data from the experiments. The frequency spectra of the far-field acoustic pressure were computed using the Farrasat equation derived from the Ffowcs Williams-Hawkings (FW-H) equation based on the acoustic analogy model. Two fixed fan casings and the rotating cross-flow fan were used as the source surfaces of the dipole noise in the Farrasat equation. The result with the standard k-$\epsilon$ model showed a much better agreement with the experimental data compared to the k-w SST and S-A models. The differences in the pressure spectra from the different turbulence models were discussed based on the instantaneous vorticity fields. It was found that the over-estimated power spectra with the k-w SST and S-A models are related to the emphasized small-scale vortices produced with these models.

Development of formulation Q1As method for quadrupole noise prediction around a submerged cylinder

  • Choi, Yo-Seb;Choi, Woen-Sug;Hong, Suk-Yoon;Song, Jee-Hun;Kwon, Hyun-Wung;Seol, Han-Shin;Jung, Chul-Min
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.9 no.5
    • /
    • pp.484-491
    • /
    • 2017
  • Recent research has shown that quadrupole noise has a significant influence on the overall characteristics of flow-induced noise and on the performance of underwater appendages such as sonar domes. However, advanced research generally uses the Ffowcs Williams-Hawkings analogy without considering the quadrupole source to reduce computational cost. In this study, flow-induced noise is predicted by using an LES turbulence model and a developed formulation, called the formulation Q1As method to properly take into account the quadrupole source. The noise around a circular cylinder in an underwater environment is examined for two cases with different velocities. The results from the method are compared to those obtained from the experiments and the permeable FW-H method. The results are in good agreement with the experimental data, with a difference of less than 1 dB, which indicates that the formulation Q1As method is suitable for use in predicting quadrupole noise around underwater appendages.